Elkay EWTLA14K User Manual

SPECIFICATIONS
ENERAL
G
Models EWTLA8K, EWTLA14K and EWTLA16K
Self-contained, electric refrigerated, wall hung water cooler. Capacity of 50°F drinking water based upon 80°F inlet water and 90°F ambient.
NOTE: Minimum 40 psi supply line pressure required in special circumstances where both sides of bi-level are in use simulta­neously to ensure adequate stream height. Does not apply to non-refrigerated units.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINI TION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free material. These water ways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is provided to allow trapping and con venient removal of water born particulate of 140 microns and larger prior to their entry into the water cooler.
CAPACITIES CHART
*GPH of 50°F Drinking Water
odel Base
M
umber Rate 70°F 80°F 90°F 100°F Watts Amps Option Cooler Lbs.
N
EWTLA8K 7.6 9.2 8.7 8.0 7.4 370 4.0 Yes No 108 EWTLA14K 13.5 15.5 14.6 13.5 12.4 665 7.2 Yes No 112 EWTLA16K 15.5 17.8 16.8 15.5 14.3 510 5.5 Yes Yes 112
*Based on 80°F inlet water temperature. •Pre-cooler capacities based on 60% spill through pre-cooler.
†Glass filler available at extra cost. Requires factory preparation to receive glass filler. Upper unit only.
Rated watts shown are based on operational (run) time, in compliance with A.R.I. Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
Room Temperature °F
ull Glass† Ship.
F
ated Load Filler •Pre- Wt.
R
COOLING SYSTEM
Motor Compressor: Hermetically sealed, 115 Volt, 60 Hertz single phase. Sealed-in lifetime oil supply. Equipped with elec­tric cord and three prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. requirements for self-extinguishing plastic material.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble-free performance.
Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
CONSTRUCTION
Fountain Top: One piece stainless steel top, polished to a uni­form Elkay bright luster finish. Exclusive Cascade basin, tested most splash-resis tant, features multi-level deck design with a built-in vandal-resistant strainer.
No Lead Two-Level
Wall Mount Water Cooler
Model EWTLA8K
Exclusive Flexi-Guard
lizes a pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat. Meets UL requirements and all sanitary codes.
Removable Panel: Removable front panel offers easy accessi­bility to interior. Cabinet design allows for flush to wall mounting.
Color Selection: Light Gray Granite is furnished as standard unless alternate wrapper color is selected. Alternate wrapper colors in vinyl are: Sandalwood and Natural Almond. All fur­nished at no extra cost. Stainless Steel units available at extra cost.
Protected by Elkay’s 5 Year Limited Warranty on the refrig­eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caus ed by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
®
Safety Bubbler: Innovative design uti-
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Printed in U.S.A. ©2011 Elkay
(Rev. 4/11) 11-2G
14-1/2" (
368mm)
14-1/2" (368mm)
1-1/4" (32mm) O.D. TAILPIECE (TRAP NOT FURNISHED)
SHUT OFF VALVE NOT FURNISHED
4-5/8" (117mm)
WALL LINE
18" (457mm)
18" (457mm)
1" (32mm)
1" (32mm)
3/4" (19mm)
3/4" (19mm)
5-7/16" (138mm)
5-7/16" (138mm)
23" (584mm) 20-1/2" (521mm)
7-1/2" (191mm)
2-1/2" (64mm)
5" (127mm)
RECOMMENDED LOCATION WASTE OUTLET 1-1/2 I.P.S. (STUB OUT FROM WALL 1" [25mm])
RECOMMENDED LOCATION 3/8" I.P.S. COLD WATER SUPPLY (STUB OUT FROM WALL 1" [32mm])
REMOTE CONNECTION
OPTIONAL ELECTRICAL OUTLET LOCATION 1-1/2 FOOT LONG (457mm) LONG POWER CORD
RECOMMENDED LOCATION ELECTRICAL OUTLET (BY OTHERS)
4-1/8" (105mm)
5/16" (8mm) DIA. HOLES IN WALL BRACKET
4-1/8" (105mm)
1-3/8" (35mm)
40" (1016mm)
TOP VIEW
FRONT VIEW
SIDE VIEW
14-1/2"
(
368mm)
14-1/2"
(368mm)
1-1/4" (32mm) O.D. TAI LP IE CE
(TRAP NOT FURNISHED)
SHUT OFF VALVE NOT FURNISHED
4-5/8"
(117mm)
WALL LINE
18"
(457mm)
18"
(457mm)
1"
(32mm)
1"
(32mm)
3/4"
(19mm)
3/4"
(19mm)
5-7/16"
(138mm)
5-7/16"
(138mm)
23"
(584mm)
20-1/2"
(521mm)
7-1/2" (191mm)
2-1/2"
(64mm)
5"
(127mm)
RECOMMENDED LOCATION
WASTE OUTLET
1-1/2 I.P.S. (STUB OUT
FROM WALL 1" [25mm])
RECOMMENDED LOCATION 3/8" I.P.S. COLD WATER SUPPLY (STUB OUT FROM WALL 1" [32mm])
REMOTE CONNECTION
OPTIONAL ELECTRICAL OUTLET LOCATI ON
1-1/2 FOOT LONG (457mm) LONG POWER CORD
RECOMMENDED LOCATION ELECTRICAL OUTLET (BY OTHERS)
4-1/8"
(105mm)
5/16" (8mm) DIA. HOLES IN WALL BRACKET
4-1/8" (105mm)
1-3/8" (35mm)
40"
(1016mm)
TOP VIEW
FRONT VIEW
SIDE VIEW
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
T
UBE TO ATTACH T
UBE IS SECURED
I
N POSITION
P
USH IN COLLET
T
O RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
NOTE: WATERFLOW
DIRECTION
S
ERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1
/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
I
NLET
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
T
UBE TO ATTACH
T
UBE IS SECURED
I
N POSITION
P
USH IN COLLET
T
O RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
NOTE: WATERFLOW
DIRECTION
S
ERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT COLD WATER SUPPLY
1
/4" O.D. TUBE WATER INLET TO COOLER
BUILDING WATER
I
NLET
No Lead Two-Level Wall Mount Water Cooler Models EWTLA8K, EWTLA14K and EWTLA16K
THIS WATER COOLER HAS BEEN DESIGNED AND BUILT TO PRO VIDE WATER TO THE USER WHICH HAS NOT BEEN ALTERED BY MATERIALS IN THE COOLER WATER WAYS.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELE PHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING BUT MAY ALSO OCCUR AWAY FROM THE BUILDING. THIS GROUND ING CAN CAUSE ELECTRICAL FEEDBACK INTO A WATER COOLER CREATING AN ELECTROLYSIS WHICH CREATES A METALLIC TASTE OR CAUSES AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY INSTALLING THE COOLER USING THE PROPER MATERIALS AS SHOWN BELOW.
THIS WATER COOLER MUST BE CONNECTED TO THE WATER SUPPLY USING A DIELECTRIC COUPLING. THE COOLER IS FUR NISHED WITH A NON-METALLIC STRAINER WHICH MEETS THIS REQUIREMENT.
THE DRAIN TRAP WHICH IS PROVIDED BY THE INSTALLER SHOULD ALSO BE PLASTIC TO COMPLETELY ISOLATE THE COOLER FROM THE BUILDING PLUMBING SYSTEM.
ROUGH-IN DIMENSIONS
IMPORTANT!
INSTALLER PLEASE NOTE:
NOTICE
Elkay
11-2G (Rev. 4/11)
2222 Camden Court Oak Brook, IL 60523
Printed in U.S.A. ©2011 Elkay
Loading...