Elkay ERW32-1A Installation Manual

ERW32-1A/2A/3A, TR32W-1A
Installation Instructions
ERW32-1A/2A/3A, TR32W-1A
Refrigeration Packages
INSTALLATION
1. This unit is intended for remote installation only. It is important to insure proper ventilation. A minimum of 6 inches
(152mm) to the front must be maintained, and 6 inches (152mm) to the rear of the unit.
2. This chiller has been designed for use with potable water and includes an o-ring seal on the drain plug. This
fitting should be replaced if the unit is to be used with more aggressive fluids.
3. Installer to provide air gap at condenser water outlet to comply with local plumbing specifications.
4. Connecting lines to be made of copper. Thoroughly flush all lines to remove all foreign matter before connecting to
5. Connect cooler to building supply with a shut-off valve and install a union connection between the valve and the
cooler.
6. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate.
Never wire the compressor directly to the power supply.
LEGEND
A = 3/8" O.D. TUBE WATER INLET
B = 3/8" O.D. TUBE WATER OUT
C = TEMPERATURE ADJUSTMENT
D = ELECTRICAL
E = 3/8" O.D. TUBE TANK DRAIN
F = 3/8" O.D. TUBE CONDENSER WATER OUTLET
G = 3/8" O.D. TUBE CONDENSER WATER INLET
96485C (Rev. D - 4/99)
PARTS LIST
ITEM NO.
1 2 3 4 5 6 7 8
9 10 11 12 13 14
*15
16 17 18 19 20 21 22 23 24 25 26
NS
PART NO.
23152C 26700C 23154C 26702C 23158C 23159C
26701C
34783005
35882C 66218C
31723000
30440C
30768C 43242004 48000036
30248C 48000070 48000067 48000069 48000068 19037000
100806740570
66216C
70772C 31738002
70020C
26703C
BOX - INSULATION BASE ASSY PANEL PANEL - FRONT COVER - INSULATION BOX BRACKET - CONDUIT CABINET WASHER - LOCK CONTROL - COLD CONDENSER ASSY STRAINER CAPACITOR SOLENOID VALVE CAPILLARY TUBE COMPRESSOR OVERLOAD GASKET - TERM COVER OVERLOAD SPRING BALE STRAP COVER - TERMINAL CLIP - COMPRESSOR MTG GROMMET - COMPRESSOR MTG EVAPORATOR ASSY EVAPORATOR DRAIN PLUG DRIER NUT PANEL - REAR
DESCRIPTION
220/240 50/60HZ PARTS LIST
ITEM NO.
15*
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF THE ABOVE WATER COOLERS OR ORDERS FOR REPAIR PARTS MUST INCLUDE MODEL NO. AND SERIAL NO. OF COOLER, NAME AND PART NO. OF REPLACEMENT PART.
NOTE: FOR USE WITH PHOTO PROCESSING APPLICATIONS, ADJUST THERMOSTAT TO WARMER SETTINGS.
PART NO.
12 13
16
30441C
30781C 37895000 37167000 40405028 40405030
CAPACITOR SOLENOID VALVE COMPRESSOR 220V/50HZ COMPRESSOR 220V/60HZ OVERLOAD 220V/50HZ OVERLOAD 220V/60HZ
DESCRIPTION
ERW32-1A/2A/3A, TR32W-1A
START-UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which
cooler is connected. A steady stream flow assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
IMPORTANT! INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building, or may occur away from the building. This grounding can cause electrical feedback into a water chiller, creating an electrolysis which causes a metallic taste or an increase in the metal content of the water. This condition is avoidable by using the proper materials indicated below. Drain fittings which are provided by the installer should be plastic to electrically isolate the chiller from the building plumbing system.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set for 50°F water (± 5°) under normal conditions. For colder water, adjust screw on item no. 9 clockwise. Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose, or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the overload protector.
Lubrication: Motors are lifetime lubricated. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free plug
which utilizes an o-ring seal. To remove plug from cooler, relieve water pressure, pull the collar towards the fitting and pull the fitting off the tube. To install plug, push fitting straight onto tubing until it reaches a positive stop, approximately 3/4.
13
7
14
23
5
12 3
9
4
WIRING DIAGRAM
ELKAY MANUFACTURING COMPANY2222 CAMDEN COURTOAK BROOK, IL 60521630.574.8484TELEX: RCA 289234
96485C (Rev. D - 4/99)
25
1
24
2 8, 26
6
15,16,17
21, 22 14
18,19,20
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
TUBE IS SECURED
IN POSITION
11
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
10
PUSH IN COLLET
RELEASE TUBE