Elkay ERS1-1D User Manual

Installation / Care / Use Manual
MODELS: ERS1-1D/2D TRS1-1D/2D EWC100
LEGEND A = 1/4" O.D. TUBE WATER OUTLET B = 1/4" O.D. TUBE WATER INLET C = TEMPERATURE ADJUSTMENT D = ELECTRICAL E = TANK DRAIN
ERS1-1D/2D TRS1-1D/2D EWC100
Refrigeration Packages
1/4" O.D. TUBE WATER INLET TO COOLER
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY
NOTE: WATER FLOW DIRECTION
BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)
115V WIRING DIAGRAM220/240V WIRING DIAGRAM
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
96703C (Rev. G) - 5/99)
ITEM
NO.
1 2 3 4 5 6 7 8 9
10
11*
12 13 14 15 16 17 18 19 20 21 22 23
ITEMIZED PARTS LIST
PART NO.
22000C 23084C 23085C 23086C 23087C 30750C 30751C 30824C 30831C 31513C 35815C 31341C
111543043890
100806740570
66199C 61521C 66308C 62031C 66363C
101516143550
19037000
55996C 70683C
DESCRIPTION
BRACKET - FAN MOTOR PANEL - FRONT ELECTRICAL COVER PANEL - RIGHT SIDE & BACK LEFT SIDE & TOP ASSY COVER - TERMINAL BALE STRAP BLADE - FAN RELAY COLD CONTROL COMPRESSOR SERVICE PAK MOTOR - FAN 115V NUT #6 HEX (FAN MOTOR MTG) GROMMET DRIER CONDENSER HEAT EXCHANGER DRAIN PLUG EVAPORATOR TANK ASSY STUD - COMPRESSOR MOUNTING CLIP STRAINER UNION 1/4 X 1/4
ERS1-1D/2D TRS1-1D/2D EWC100
INSTALLATION
1. This unit is intended to be installed underneath a conventional kitchen sink, in a cabinet not less than 36" (914mm) wide (inside dimension). Two air openings with a minimum of 40" square (1016mm/square) each, minimum of 75% open area, must be provided in the cabinet. One opening must be in the overhang of the toe space. The other opening near the top of the cabinet. The remote unit must be installed with a minimum of 3" clearance between the unit and the rear wall of the cabinet. It can be installed flush against either side wall of the cabinet. The side louvers which are not against the cabinet must not be blocked by objects located within 4" (102mm) of the louvers. In addition, a minimum of 1 to 2" (25 to 51mm) clearance must be provided between the toe space air opening and front of the unit.
2. Water inlet and outlet are 1/4" (6 mm) O.D. tubes with connectors supplied.
3. Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being connected to cooler.
4. Connect cooler to building supply line with a shut-off valve and install a 3/8" O.D. (10mm) unplated copper tube between the valve and cooler. Remove burr from outside of water line. Insert water line into fitting until it reaches a positive stop, approximately 3/4" (19mm).
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor directly to the power supply.
220/240V, 50 HZ
ITEM
PART NO.
NO.
6
30583C
7
30584C
9
30622C
11*
31904C
12
31395C
-
31407C
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.
DESCRIPTION
COVER - TERMINAL BALE STRAP RELAY COMPRESSOR SERVICE PAK MOTOR - FAN OVERLOAD/RELAY
START-UP
1. Open supply line valve.
2. Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected. Steady stream assures all air is removed.
3. Rotate fan to insure proper clearance and free fan action.
4. Connect to electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set at 45°F (± 2°) under normal conditions. For colder water, adjust screw on item no. 10 in clockwise direction. Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload protector.
Lubrication: Motors are lifetime lubricated. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free
connectors which utilize an o-ring seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4.
5 1, 8, 12, 13 10 3
16
4
17
ELKAY MANUFACTURING COMPANY - 2222 CAMDEN COURT - OAK BROOK, IL 60523 - 630.574.8484
96703C (Rev. G - 5/99)
15
6, 7, 9, 11
14, 20, 21
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
19
2
18