ERP A2-8C*A ERP A2-8RAC*A ERP A VR2-8C*A ERP A VR2-8RAC*A LPTEA8C*A LPTEA8RAC*A
Installation/Care/Use Manual
SwirlFlo® Refrigerated Fountains with FLEXI-GUARD
®
SEE FIG. 4 OR 5
42
SEE FIG. 11
38, 40, 41
35
44
37, 39, 41
36
44
ERP A2-8C, LPTEA8C
ERPA2-8RAC, LPTEA8RAC
Installer
To assure you install this model easily and correctly, PLEASE READ
THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After
installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. T O WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR AW A Y FROM THE
BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELECTROLYSIS WHICH CAUSES A MET ALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER.
THIS CONDITION IS A VOIDABLE BY USING THE PROPER MATERIALS AS INDICA TED. ANY DRAIN FITTINGS
PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALL Y ISOLA TE THE FOUNT AIN
FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE
WATER INLET
TO COOLER
FIG. 1
FIG. 3
NOTE: WATER FLOW
DIRECTION
48
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
45
BASIN
46
47
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
1
FIG. 4
2
FIG. 2
NOTE: WHEN INSTALLING
REPLACEMENT BUBBLER
3
AND PEDESTAL, TIGHTEN
NUT (ITEM 5 OR 33) ONLY
TO HOLD PARTS SNUG
IN POSITION. DO NOT
4
OVER TIGHTEN.
5
51
49
33
FIG. 5
97876C (REV. D - 12/04)
ERP A2-8C*A ERP A2-8RAC*A ERP A VR2-8C*A ERP A VR2-8RAC*A LPTEA8C*A LPTEA8RAC*A
LPTEA8C LPTEA8RAC
97876C (REV. D - 12/04)
FIG. 6
PAGE 2
LEGEND
A = 1/4" O.D. TUBE CONNECT (CHILLER WATER OUTLET)
B = 3/8" O.D. TUBE CONNECT (CHILLER WA TER INLET) SHUT OFF V AL VE BY OTHERS
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL INLET