ERHP2-8C*A ERHP2-8DSC*A ERHP2-8FC*A ERHP2-8RAC*A LKTE8C*A LKTE8FC*A
Installation/Care/Use Manual
Refrigerated Fountains with FLEXI-GUARD
26
28
SEE FIG. 8
®
SEE FIG. 5
27
30
ERHP2-8C, ERHP2-8DSC, ERHP2-8FC, AND LKTE8C
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE
CODES. After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
97159C (Rev. B - 10/00)
ERHP2-8C*A ERHP2-8DSC*A ERHP2-8FC*A ERHP2-8RAC*A LKTE8C*A LKTE8FC*A
PURGADOR DE 1¼ PROPORCIONADO
C = 1-1/4 TRAP FURNISHED
SIPHON 1-1/4 FOURNI
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT
D = ELECTRICAL OUTLET LOCATION
IS ON RIGHT AND UPPER FOUNTAIN IS ON LEFT
ERHP2-8C SHOWN. FOR ERHP2-8RAC, LOWER FOUNTAIN
FIG. 1
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
97159C (Rev. B - 10/00)
PAGE 2
FROM WALL SHUT OFF BY OTHERS
(38mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼ DE DIÁMETRO.
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2"
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38mm) OUT
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU.
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN