Elkay ERFP8C-B Installation Manual

ERFP8C*B ERFPVR8C LNFE8C*B
Installation/Care/Use Manual
Soft Sides® Refrigerated Fountains with FLEXI-GUARD
ERFP8C
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLA­TION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
®
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC­TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE WATER INLET TO COOLER
FIG. 1
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
4
3
17
BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)
2
10
FIG. 2
5
6
NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN
7
NUT (ITEM 9 OR 32) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT
8
OVER TIGHTEN.
34
33
FIG. 3
11
19
PAGE 1
FIG. 4
9
32
FIG. 5
97157C (Rev. L - 1/02)
ERFP8C*B ERFPVR8C LNFE8C*B
MODEL LNFE8C
LEGEND A = 3/8" O.D. TUBE CONNECT (CHILLER WATER OUTLET) B = 3/8" O.D. TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS C = 1-1/4" TRAP FURNISHED D = ELECTRICAL INLET
97157C (Rev. L - 1/02)
FIG. 6
PAGE 2