ERFP2-8C*C ERFPVR2-8C*A ERFP2-8RAC*A ERFPVR2-8RAC*A LNTE8C*C LNTEA8RC*A
Installation/Care/Use Manual
Soft Sides® Refrigerated Fountains with FLEXI-GUARD
®
ERFP28C, LNTE8C
ERFP28RAC, LNTE8RAC
Installer
To assure you install this model easily and correctly, PLEASE READ
THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After
installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. T O WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR AW A Y FROM THE
BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELECTROLYSIS WHICH CAUSES A MET ALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER.
THIS CONDITION IS A VOIDABLE BY USING THE PROPER MATERIALS AS INDICA TED. ANY DRAIN FITTINGS
PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALL Y ISOLA TE THE FOUNT AIN
FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER
INLET
NOTE: WATER FLOW
DIRECTION
34
SERVICE STOP
(NOT FURNISHED)
17
1811
10
2
5
FIG. 3
FIG. 2FIG. 1
7
6
NOTE: WHEN INSTALLING
REPLACEMENT BUBBLER
AND PEDESTAL, TIGHTEN
NUT (ITEM 9 OR 32) ONLY
TO HOLD PARTS SNUG IN
8
POSITION. DO NOT OVER
TIGHTEN.
9
FIG. 4 FIG. 5
97870C (Rev. L - 1/12)
21
20
32

ERFP2-8C*C ERFPVR2-8C*A ERFP2-8RAC*A ERFPVR2-8RAC*A LNTE8C*C LNTEA8RC*A
FIG. 6
LNTE8C LNTE8RAC
97870C (Rev. L - 1/12)
PAGE 2
LEGEND
A = 1/4" O.D. TUBE CONNECT (CHILLER W A TER OUTLET)
B = 3/8" O.D. TUBE CONNECT (CHILLER WA TER INLET) SHUT OFF V AL VE BY OTHERS
C = 1-1/4" TRAP FURNISHED
D = ELECTRICAL INLET

ERFP2-8C*C ERFPVR2-8C*A ERFP2-8RAC*A ERFPVR2-8RAC*A LNTE8C*C LNTEA8RC*A
INST ALLA TION INSTRUCTIONS
1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and
side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf.
NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. See chiller instructions for
additional instructions.
2. Make water supply connections. Install a shut-off valve and union connection to building water supply (valve and union not
provided). Turn on the water supply and flush the line thoroughly.
3. ERFP MODELS: Make connection between remote chiller and building supply line. Inlet port is marked on the chiller (1/4" O.D.
copper tube). Bend the copper tube (provided) at an appropriate length from chiller to opening in frame. Install the in-line strainer
(provided with chiller) by pushing it in until it reachs a positive stop, approximately 3/4" (19mm) on the marked chiller inlet port.
Connect building supply line to strainer. DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE
O-RINGS MAY RESULT. (See Figures 7 or 13).
LNTE MODEL: Mount filter head assembly to side of chiller (See Figure 9). Make connection between filter and building supply
line (3/8" O.D. tube not provided). Inlet port is marked on the chiller (1/4" O.D. copper tube). Install a 1/4" x 1/4" union (provided)
on the inlet port. Insert the 1/4" poly tubing (provided) into fitting on filter and connect to the union on the chiller. DO NOT SOLDER
TUBES INSERTED INTO THE UNIONS AS DAMAGE TO THE O-RINGS MAY RESULT. (See Figures 8 or 12).
4. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame. Be sure that
panel is engaged with hanger at top of frame before releasing it.
5. Install the fountains. Remove access cover plates on underside of fountains and save the screws. Mount the fountains to the
upper panel and the wall frame with (4) 5/16" x 3/4" (19mm) long bolts and nuts (provided). Tighten securely.
NOTE: The short fountain should be mounted to the upper left hand side of the panel.
6. Remove elbow from end of p-trap and attach it to drain tube. Re-attach elbow to p-trap and cut waste tube to required length
using plumbing hardware and trap as a guide.
7. ERFP MODELS: Make connections between remote chiller outlet tube and fountains. Outlet port is marked on the chiller
(1/4" O.D. copper tube). Install a 1/4" tee (provided) on the marked chiller outlet port. Insert the 1/4" poly tubing coming from the
fountains into the tee. Turn on water supply and check for leaks. DO NOT SOLDER TUBES INSERTED INTO THE TEE AS
DAMAGE TO THE O-RINGS MAY RESULT. (See Figures 7 or 13).
LNTE MODEL: Make connections between remote chiller and fountains. Outlet port is marked on the chiller (1/4" O.D. copper
tube). Install a 1/4' tee (provided) on the marked chiller outlet port. Insert the 1/4" poly tubing coming from the fountains into the
tee. Turn on water supply and check for leaks. DO NOT SOLDER TUBES INSERTED INTO THE TEE AS DAMAGE TO THE O-
RINGS MAY RESULT. (See Figures 8 or 12).
8. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure
regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line
pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.
9. Make electrical connections to the chiller. See chiller instructions.
10.Check stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the
screw on regulator item 10 by using a small screwdriver through the small hole in the push button item 3 (See Fig.3). Clockwise
adjustment will raise stream height and counter-clockwise will lower stream height. For best adjustment stream should hit basin
approximately 6 1/2" from the bubbler.
11. Mount lower panel. Loosen the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue of lower panel under
lower edge of already installed upper panel. Tighten previously loosened screws securely.
12. Replace bottom access panel to fountain basin using screws provided. Tighten securely.
TROUBLE SHOOTING AND MAINTENANCE
1. Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from
orifice with a small round file not over 1/8" diameter or a small diameter wire. CAUTION: Do not file or cut orifice materials.
2. Stream Regulator: If orifice is free of material deposits, regulate flow according to instruction 10 stated above.
3. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal.
To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Figure 2). To
insert tubing, push tube straight into the fitting until it reaches a positive stop, approximately 3/4".
ERFP28C/ERFP28RAC TUBE ROUTING
22 - TO
BUBBLER
22
31
CHILLER
OUTLET
22
22
13
CHILLER
INLET
FIG. 7
22 - TO
BUBBLER
CHILLER
OUTLET
FIG. 8
LNTE8C/LNTE8RAC TUBE ROUTING
22
22
31
26
PAGE 3
22
22
27
24
29
WATER
INLET
97870C (Rev. L - 1/12)
23
30
25
28

ERFP2-8C*C ERFPVR2-8C*A ERFP2-8RAC*A ERFPVR2-8RAC*A LNTE8C*C LNTEA8RC*A
PAR TS LIST
ITEM NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
NS
NS
PART NO.
LK464
15005C
45662C
45663C
50986C
A54874
56011C
55997C
75580C
61313C
75672C
112627543890
55996C
28782C
28783C
27959C
55000661
55000665
26839C
27028C
40045C
28823C
27026C
100322740560
45392C
56092C
22490C
51294C
51299C
70683C
70792C
70818C
70822C
70823C
70862C
15009C
56369C
11 1577243890
11 1577343890
Drain
Retaining Nut
Push Button
Push Button Sleeve
Regulator Holder
Orifice Assy
Housing Assy
Pedestal
Bubbler Locknut
Regulator
Cap Screw
Screw - #10-24 X .50 PHTC
Strainer
Fountain Arm - Short
Fountain Arm - Long
Fountain Arm - Long (Glassfiller)
Bottom Cover Plate - Short
Bottom Cover Plate - Long
Back Panel - ERFP28C
Back Panel - ERFP28RAC
Hex Nut
Regulator Mounting Bracket
Lower Panel
Gasket - VR Model
Bubbler - VR Model
Poly Tubing (Cut To Length)
Filter Mounting Bracket
Filter Head Assy
Filter Assy
Union - 1/4
Screw - #8-18 x .75" PH
Elbow - 3/8" (10mm)
Fitting - Superseal 1/4" (6mm)
Fitting - Superseal 3/8" (10mm)
Tee - 1/4
Nipple Assy
Edge Trim - 2FT.
Screw - Mach 5/16-18 x 3/4
Nut - Hex 5/16-18
DESCRIPTION
FIG. 9
FIG. 11
14
22
SEE
FIG . 3
33
SEE FIG. 4 OR 5
22
12, 15
RH ADA
LH ADA
FIG. 10
16
19
1
22 - TO
BUBBLER
22
31
22
31
CHILLER
OUTLET
97870C (Rev. L - 1/12)
LNTE8C W/GLASSFILLER
ERFP28C/ERFP28RAC W/GLASSFILLER
32
22 - TO GLASSFILLER
22 - TO
BUBBLER
22
22
22
31
22
31
26
22
CHILLER
OUTLET
WATER
INLET
FIG. 13FIG. 12
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
ELKAY MANUFACTURING COMP AN Y • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
FOR PARTS, CONT ACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PAGE 4
32
22 - TO
GLASSFILLER
22
22
13
CHILLER
INLET