Elkay ER30-1C Installation Manual

ER30-1C
Installation Instructions
ER30
Refrigeration Package
NOTICE: This water cooler must be connected to the water supply using a dielectric coupling.
IMPORTANT! INSTALLER PLEASE NOTE.
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building, or may occur away from the building. This grounding can cause electrical feedback into a water chiller, creating an electrolysis which causes a metallic taste or an increase in the metal content of the water. This condition is avoidable by using the proper materials indicated below.
1. This unit is intended for remote installation only. It is important to insure proper ventilation. A minimum of 6 inches (152mm) to the front must be maintained, and 6 inches (152mm) to the rear of the unit.
2. This chiller has been designed for use with potable water and includes an o-ring seal on the drain plug. This fitting should be replaced if the unit is to be used with more aggressive fluids.
3. Connecting lines to be made of copper. Thoroughly flush all lines to remove all foreign matter before connecting to cooler. If flushing does not remove all particles, a water strainer should be installed in the supply line.
4. Connect cooler to building supply with a shut-off valve and install a union connection between the valve and the cooler.
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire the compressor directly to the power supply.
6. For use with photo processing applications, adjust thermostat to warmer settings.
START UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which cooler is connected. A steady stream assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
LEGEND
A = 3/8" O.D. TUBE W A TER INLET C = TEMPERATURE ADJUSTMENT E = 3/8" O.D. TUBE T ANK DRAIN
B = 3/8" O.D. TUBE WA TER OUTLET D = ELECTRICAL
98468C (Rev. B 6/11)
ITEMIZED P ARTS LIST
ITEM
NO.
*INCLUDES COMPRESSOR, OVERLOAD & CSIR BOX ASSEMBLY. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
*29
30
1 2 3 4 5 6 7 8 9
PART NO.
28165C 28218C 28166C 28167C 23158C 27702C 35882C 35792C 31180C 31181C 66620C 66621C 36045C 35984C 35989C 35988C 35990C 30040C 50196C 66624C 70772C 66623C 70020C
34783005
28408C 30039C 70274C 36252C 36310C 35895C
DESCRIPTION
Box - Insulation Base Assy Panel Panel - Front Cover - Insulation Box Cabinet Control - Cold Fan Motor Fan Blade Fan Bracket Condenser Drier Overload Cover Overload Gasket (Terminal Cover) Overload Spring Bale Strap Electrical Box Cover Grommet Evaporator Assy Drain Plug Heat Exchanger Nut Washer - Lock Panel - Rear Electrical Box Compressor Sleeve CSIR Box Assy Compr. Service Pak Freeze Control
ER30-1C
TROUBLE SHOOTING AND MAINTENANCE
Temperature Control: Factory set for 50°F water under normal conditions.
To adjust water temperature, turn screw on Item No. 7 clockwise for colder, counter clockwise for warmer. Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose, or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the overload protector.
Lubrication: Motors are lifetime lubricated. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-
free plug which utilizes an o-ring seal. To remove plug from cooler, relieve water pressure, pull the collar towards the fitting and pull the fitting off the tube. To install plug, push fitting straight onto tubing until it reaches a positive stop, approximately 3/4”.
20, 23, 24
19, 27
3
13, 14, 15,
16, 17
28
25
8
10
115V Wiring
98468C (Rev. B 6/11)
22
30
29
4
5
7
18, 26
Diagram
1
21
2
12
ELKAY MANUF ACTURING COMP ANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
FOR PAR TS, CONT ACT YOUR LOCAL DISTRIBUT OR OR CALL 1.800.323.0620