Elkay EFRP8C Installation Manual

EFRP8C & EFRPC8C
Installation/Care/Use Manual
EFRP8C & EFRPC8C
Refrigerated Fountains with FLEXI-GUARD
21
13
SEE SPREADER
DETAIL
®
20
19
SEE BUBBLER
ASSY DETAIL
22
36, 37
Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA­TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
97018C (Rev. C - 9/02)
97018C (Rev. C - 9/02)
PAGE 2
EFRP8C & EFRPC8C ROUGH-IN
EFRP8C & EFRPC8C
LEGEND: A = WATER INLET LOCATION (BOTH SIDES). 3/8" O.D. UNPLATED COPPER TUBE CONNECT. B = WASTE OUTLET LOCATIONS (BOTH SIDES). 1-1/4" O.D. DRAIN (TRAP NOT FURNISHED) C = ELECTRICAL SUPPLY LOCATION (BOTH SIDES) D = MOUNTING HOLES FOR 1/4" DIA. (6mm) SCREWS E = WASTE OUTLET LOCATION. 1-1/4" O.D. DRAIN (TRAP NOT FURNISHED)
FIG. 1