Elkay EFRCM8CDK Specifications

SPECIFICATIONS
GENERAL
Fully recessed cup dispenser-disposer with push back type cup filler and integral drain.
Cup dispenser holds 100 4 oz. cups. Access door has cylinder lock and sight opening. Water dispenser is push back self closing type. Built-in louver covered drain. Cup dispenser contains removable receptor for discarded cups behind self closing door and locked access door.
Wall type, fully recessed, electric refrigerated water cooler
in undersection. Cooling unit removable without disturbing
electrical or drain connections. Condenser, air cooled by fan. Plumbing and electri cal connections are concealed. Entire unit does not extend more than 1/2" from wall surface.
Flexi-Guard front panel below stream projector has in-line flow regulator from 20 to 105 psi water pressure.
®
safety bubbler. Control push button located on
No Lead Wall Mount Fully-Recessed
Water Cooler with Cup Filler,
Dispenser and Waste Receptacle
Models EFRCM8CDC and EFRCM12CDC
Model EFRCM8CDC
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF
1996.
Elkay Water Coolers are manufactured with a waterway sys­tem utilizing copper components and completely lead-free materials. These waterways have no lead because all lead mater
ials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is pro­vided to allow trapping and convenient removal of waterborne particulate of 140 microns or larger prior to their entry into the water cooler.
CAPACITIES CHART
*GPH of 50°F Drinking Water
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Cooler Lbs.
EFRCM8CDC 8.0 9.2 8.6 8.0 325 3.3 Yes 159 EFRCM12CDC 8.0 15.7 13.8 12.0 325 3.3 Yes 160
*Based on 80°F inlet water temperature. Pre-cooler capacities based on
60% spill through pre-cooler.
Rated watts shown are based on operational (run) time, in accordance with A.R.I. Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water
Room Temperature °F
Full Ship.
Rated Load Pre- Wt.
temperature.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type, 115V, 60 Hertz s
ingle phase. Lubricated for life.
Condenser:Fan cooled. Fan motor is permanently lubricated. Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS foam.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble-free performance.
Temperature Control: Enclosed adjustable thermostat i
ily acces sible by removing front grill panel.
eas
CONSTRUCTION
Cup Dispenser–Disposer: 18 gauge, type 304 stainless steel designed to fit against side of fully recessed water cooler. Access doors are flush with front surface of frame which con­tains recessed area containing self closing push back cup filler, louvered cover drain and LK144 lock and key.
Fountain Top:#16 gauge, type 304 one piece stainless steel. Anti-splash design has exclusive C
ascade basin, tested most splash-resis tant. Foun tain has 1-3/4" coved corners. Exposed surfaces polished to a uniform Elkay luster finish.
Exclusive Flexi-Guard
®
Safety Bubbler: Innovative design
utilizes a pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original posi­tion. Strong. Abrasion-resistant. Anti-sweat. Meets UL requirements and all sanitary codes. Keyed in location to prevent rotation.
Front Panel Grill: Made of type 304 stainless steel, polished to a uniform Elkay finish. Removable louvered ventilating grill encloses refrigeration unit and plumbing.
Wall Mounting Box: MB23A mounting box furnished with each unit. Box allows flush mounting to finished wall, plumbing and electrical ser vice holes are prepunched on both right and left side to faci
litate installation.
Protected by Elkay’s 5 Year Limited Warranty on the refrig­eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caus ed by reason of connecting this product to supply line pressures lower t
20 psi or higher
han
than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61 and 372.
s
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice.
Elkay
elkayusa.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these featu overlooked.
Printed in U.S.A. ©2012 Elkay
(Rev. 10/12) 10-2I
res are not
(NOT FURNISHED)
SEE SECT.
A-A
11-3/4" (298mm)
OPERATION OF QUICK CONNECT FITTINGS
USHING TUBE IN BEFORE ULLING IT OUT HELPS TO
No Lead Wall Mount Fully-Recessed Water Cooler with Cup Filler, Dispenser and Waste Receptacle Models EFRCM8CDC and EFRCM12CDC
ROUGH-IN DIM ENSIONS
IMPORTANT!
INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical
back i
feed taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below.
nto a water cooler creating an electrolysis which creates a metallic
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
(191mm)
1
(483mm)
1
(406mm)
1
(13mm)
(298mm)
(559mm)
(37mm)
(1378mm)
PUSH
FILTER
(837mm)
(603mm)
1/4" O.D. TUBE WATER INLET TO COOLER
NOTE: WATERFLOW
DIRECTION
RELEASE TUBE PULLING IT OUT HELPS TO PUSHING TUBE IN BEFORE AB C
TUBE TO ATTACH
IN POSITION
TO RELEASE TUBE SIMPLY PUSH IN
TUBE IS SECURED
PUSH IN COLLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
A B
24-3/4" (629mm) WALL OPENING
3/8" O.D. TUBE CONNECT COLD WATER SUPPLY
TUBE IS SECURED
IN POSITION
SECTION A-A
12 GAL.
STRAINER
BUILDING WATER
SERVICE STOP
PUSH IN COLLET
TO RELEASE TUBE
C
P P
RELEASE TUBE
INLET
(114mm)
MADE FROM LEFT SIDE
(210mm)
(140mm)
INLET
(95mm)
INLET
(171mm)
OF UNIT
(1340mm)
(130mm)
OUTLET
TO FLOOR
DETAIL
(133mm)
CUP FILLER
CLIPS
BOX
CLIPS
NOT SHOWN
SCREWS
LEFT
LEFT SIDE
SCREWS
OTHERS)
CONTROL
3/8" F.P.T.
8 GAL.
Elkay
10-2I (Rev. 10/12)
2222 Camden Court Oak Brook, IL 60523
Printed in U.S.A. ©2012 Elkay