To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION
FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER
LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY
FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN,
CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL
CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS
INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO
ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT
STUB 1-1/2” (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (BOTH SIDES).
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN (BOTH SIDES).
C = ELECTRICAL SUPPLY LOCATION (BOTH SIDES).
NOTES:
1. THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT
ARE INTENDED TO BE USED TO MOUNT THE BOX. USE SIX SCREWS OR BOLTS (NOT PROVIDED).
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT
STUB 1-1/2” (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (LEFT SIDE ONLY).
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN (LEFT SIDE ONLY).
C = ELECTRICAL SUPPLY LOCATION (BOTH SIDES).
*WATER AND DRAIN CONNECTIONS MUST BE MADE FROM LEFT SIDE ONLY.
NOTES:
1. THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT
ARE INTENDED TO BE USED TO MOUNT THE BOX. USE SIX SCREWS OR BOLTS (NOT PROVIDED).
Note: Danger! Electric shock hazard. Disconnect power before servicing unit.
INSTALLATION INSTRUCTIONS
1. Remove shipping brace from mounting box and discard.
2. Fasten mounting box into wall cutout using screws or bolts (provided by others) through the holes or knock
outs provided on each side of the mounting box. (See Fig. 1 or 2)
3. Install fountain body to mounting box using #10 x .63” (16mm) PHSM screws and large clips provided.
4. Place refrigeration package into mounting box and connect water lines. (See Page 5 for details)
5. Water inlet is 3/8” O.D. and waste tube is 1-1/4” O.D. Contractor is to supply waste trap and service stop
valve in accordance with local codes.
6. Connecting lines to be unplated copper and thoroughly ushed to remove all foreign matter before
connecting
to refrigeration package. The furnished strainer (Item 18) should be added to the supply line.
7. Connect the refrigeration package to the supply line service stop valve. Connect supplied fountain (internal
plumbing) tubes as shown in gures 3, 4, 5, or 6. Remove any burrs from water tubes before inserting into
ttings. (See Figs. 13 and 14) DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE
TO THE O-RINGS MAY RESULT.
8. Electrical: Insure power supply is identical in voltage, hertz, and phase to that specied on the refrigeration
package serial plate. Never wire compressor directly to the power supply.
9. Turn water supply on and check thoroughly for leaks.
10. Release air from tank by depressing push button; a steady stream of water assures all air is removed.
11. Re-check for leaks.
12. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, turn adjustment screw on
regulator (Fig. 8). Clockwise adjustment will raise the stream height and counter-clockwise adjustment
will lower stream height. For best adjustment, stream should hit basin approximately 6-1/2” from the
bubbler.
13. Rotate fan blade on refrigeration package to insure proper clearance and free fan action.
14. Connect power supply.
15. Install grill using #8 x 1.00” (25mm) PH screws and small clips provided.
TROUBLE SHOOTING AND MAINTENANCE
1. Orice Assy: Mineral deposits on orice can cause water ow to spurt or not regulate. Mineral deposits
may be removed from orice with a small round le not over 1/8 diameter or a small diameter wire.
CAUTION: Do not le or cut orice materials.
2. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize
an o-ring water seal. To remove tubing from the tting, relieve water pressure, push in on the gray collar
while pulling on the tubing (See Fig. 13). To insert tubing, push tube straight into the tting until it reaches