S P E CI F IC ATI O NS
ENERAL
G
Model EFOA8 has the Flexi-Guard electronic sensor-operated valve and automatic flow regula­tor to provide constant stream from 20 to 105 psi. Bubbler ori­fice is fully protected to meet all sanitary codes.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF
1988.
Elkay Water Coolers are manufactured with a waterway sys­tem utilizing copper components and completely lead-free materials. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is pro­vided to allow trapping and convenient removal of water born particulate of 140 microns and larger prior to their entry into the water cooler.
CAPACITIES CHART
GPH of 50°F Drinking Water
*
Model Base
Number Rate 70°F 80°F 90°F 100°F Watts Amps Option Lbs.
EF OA8 5.3 9.2 8.6 8.0 7.4 420 5.5 No 81
*Based on 80°F inlet water temperature. Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
Room Temperature °F
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type, 115V, 60 Hertz. All are single phase. Sealed in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Tank is stainless steel. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. requirements for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble free performance.
Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
CONSTRUCTION
Fountain Top: Type 304 one piece stainless steel top, polished to a uniform Elkay bright luster finish. Exclusive Cascade basin, tested most splash resis tant, features multi­level deck design with a built-in vandal-resistant strainer.
Electronic Sensor Operation: On-Off solenoid valve is actuated by an infra-red lightbeam sensor. When lightbeam is interrupted by subject in front of cooler desiring a drink, the sensor actuates the solenoid valve which then opens to allow
®
Safety Bubbler with an
Full Glass Ship.
Rated Load Filler Wt.
No Lead Floor Model Water Cooler
Sensor-Operated Air Cooled
Model EFOA8
odel EFOA8
M
water flow. No physical contact with cooler is required. A built in time delay is provided to prevent actuation by persons moving past cooler. There is a maximum running time of 30 seconds to prevent malicious damage to the cooler or water damage if sensor vision is blocked. Unit automatically resets when blockage is removed.
Exclusive Flexi-Guard
utilizes a pliable elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat.
Removable Panel: Removable front panel offers easy accessibility to interior.
Color Selection: Models available in Light Gray Granite, Almond, Sandalwood and Stainless Steel panels.
Cabinet: Cabinet design allows for flush to wall mounting, or free standing.
Protected by Elkay’s 5 Year Limited Warranty on the refrig­eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
®
Safety Bubbler: Innovative design
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Printed in U.S.A. ©2011 Elkay
(Rev. 4/11) 9-8D
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY 1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1/4" O.D. TUBE WATER INLET TO COOLER
BUILDING WATER
INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
TANK DRAIN
4-5/8"
(117 mm)
1-1/4" (32 mm)  O.D. TAILPIECE
(TRAP NOT 
FURNISHED)
14-1/2"
(368 mm)
18"
(457 mm)
5"
(127 mm)
2-1/2"
(64 mm)
14-1/2"
(368 mm)
PLUMBING ROUGH-IN CAN BE LOCATED ANYWHERE W IT HIN TH IS ARE A.
C
L
FLOOR  LINE
WATER OUTLET 1-1/4" I.P.S.
41-7/16"
(1051 mm)
40"
(1016 mm)
23"
(584mm)
OPTIONAL 
ELECTRICAL
OUTLET LOCATION
1-1/4" (32 mm)  O.D. TAILPIECE
4 FOOT (1.2 M) 
LONG POWER 
CORD
ELECTRICAL OUTLET
(BY OTHERS)
3/8" IPS COLD WATER SUPPLY (STUB OUT FROM WALL 1" (25 mm) WATER INLET SHUTOFF VALVE BY OTHERS  (3/8" O.D. TUBE OUTLET)
No Lead Floor Model Water Cooler
®
Sensor-Operated Air Cooled Model EFOA8
ROUGH-IN DIMENSIONS
IMPORTANT!
NSTALLER PLEASE NOTE:
his water cooler has been designed and built to provide water to the user which has
T
ot been altered by materials in the cooler waterways.
n
he grounding of electrical equipment such as telephone, computers, etc., to water
T
ines is a common procedure. This grounding may be in the building but may also
l
ccur away from the building. This grounding can cause electrical feedback into a
o
ater cooler creating an electrolysis which creates a metallic taste or causes an
w
ncrease in the metal content of the water. This condition is avoidable by installing the
i
ooler using the proper materials as shown below.
c
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
I
OTICE
N
Elkay
9-8D (Rev. 4/11)
2222 Camden Court Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A. ©2011 Elkay