Elkay EFHA14 User Manual

®
S P E C IF I C AT I O N S
ENERAL
G
Self-contained, electric refrigerated, floor model water cooler. Capacity of 50°F drinking water, based upon 80°F inlet water and 90°F ambient.
Non-pressurized tank system is standard. Non-pressurized water tank is located after bubbler valve, so that tank is sub­ject to line pressure only when valve button is pressed.
NO LEAD DESIGN
1988.
Elkay Water Coolers are manufactured with a waterway sys­tem utilizing copper components and completely lead-free materials. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is pro­vided to allow trapping and convenient removal of water born particulate of 140 microns and larger prior to their entry into the water cooler.
CAPACITIES CHART
*GPH of 50°F Drinking Water
odel Base
M
umber Rate 70°F 80°F 90°F Watts Amps Option Lbs.
N
EF HA 8 8.0 9.2 8.6 8.0 920 9.5 Yes 90
EF HA 1 4 13.5 15.5 14.5 13.5 1100 12 Yes 93
*Based on 80°F inlet water temperature.
Glass filler available at extra cost. Requires factory preparation to receive glass
filler. Foot pedal available. Factory installed only. Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
Room Temperature °F
ull Glass
F
ated Load Filler Wt.
R
COOLING SYSTEM
Motor Compressor: Hermetically sealed, 115V, 60 Hertz. single phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. requirements for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble free performance.
Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
Insulated Hot Tank: Stainless steel storage tank heats and serves up to 40 (6 oz.) cups per hour of piping hot water for soups and beverages.
CONSTRUCTION
Fountain Top: One piece stainless steel top, polished to a uniform Elkay bright luster finish. Exclusive Cascade basin, tested most splash resis tant, features multi-level deck design with a built-in vandal-resistant strainer.
hip.
S
No Lead Floor Model Water Cooler
with Hot Water Service, Air Cooled
Models EFHA8 and EFHA14
odel EFHA8
M
Stream Projector: Separate push button control. Stream projector with protective hood meets all sanitary codes and has in-line flow regulator from 20 to 150 psi water pressure.
Exclusive Flexi-Guard
utilizes a pliable elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat.
Removable Panel: Removable front panel offers easy accessibility to interior.
Color Selection: Models available in Light Gray Granite, Almond, Sandalwood and Stainless Steel panels.
Cabinet: Cabinet design allows for flush to wall mounting, or free standing.
Protected by Elkay’s 5 Year Limited Warranty on the refrig­eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
®
Safety Bubbler: Innovative design
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Printed in U.S.A. ©2011 Elkay
(Rev. 5/11) 9-3H
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY 1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1/4" O.D. TUBE WATER INLET TO COOLER
BUILDING WATER
INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
TANK DRAIN
4-5/8"
(117mm)
O.D. TAILPIECE (TRAP NOT FURNISHED)
14-1/2"
(368mm)
18"
(457mm)
5"
(127mm)
2-1/2"
(64mm)
14-1/2"
(368mm)
HOT WATER OUTLET
PLUMBING ROUGH-IN CAN BE LOCATED ANYWHERE W I TH IN TH IS A RE A.
C
L
FLOOR LINE
WATER OUTLET 1-1/4" I.P.S.
41-3/8"
(1051mm)
40"
(1016mm)
17"
(432mm)
ELECTRICAL OUTLET
(BY OTHERS)
1-1/4" (32mm) O.D. TAILPIECE
4 FOOT (1.2M) LONG
POWER CORD
OPTIONAL
ELECTRICAL OUTLET
(BY OTHERS)
3/8" IPS COLD WATER SUPPLY (STUB OUT FROM WALL 1" [25mm]) WATER INLET SHUTOFF VALVE BY OTHERS (3/8" O.D. TUBE OUTLET)
No Lead Floor Model Water Cooler
®
with Hot Water Service, Air Cooled Models EFHA8 and EFHA14
ROUGH-IN DIMENSIONS
IMPORTANT!
NSTALLER PLEASE NOTE:
his water cooler has been designed and built to provide water to the user which has
T
ot been altered by materials in the cooler waterways.
n
he grounding of electrical equipment such as telephone, computers, etc., to water
T
ines is a common procedure. This grounding may be in the building but may also
l
ccur away from the building. This grounding can cause electrical feedback into a
o
ater cooler creating an electrolysis which creates a metallic taste or causes an
w
ncrease in the metal content of the water. This condition is avoidable by installing the
i
ooler using the proper materials as shown below.
c
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
I
OTICE
N
Elkay
9-3H (Rev. 5/11)
2222 Camden Court Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A. ©2011 Elkay