Elkay EDFPW210C Installation Manual

Page 1
Installation/Care/Use Manual
Model: EDFPW210C
Composite Non-Refrigerated Fountains
Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE WATER INLET TO COOLER
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)
PAGE 1
FIG. 2FIG. 1
97014C (Rev. E - 2/04)
Page 2
DETAIL 2
FINISHED FLOOR
FIG. 4
LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN C = MOUNTING HOLES FOR SECURING FOUNTAIN TO WALL
WARNING: WALL MOUNTING SURFACE MUST BE SMOOTH AND EVEN. DISTOR-
TION TO BACK PANEL DUE TO ATTACHMENT TO AN UNEVEN SUREFACE WILL
RESULT IN DAMAGE AND/OR BREAKAGE OF THE BACK PANEL.
CARE AND MAINTENANCE OF ELKAY COMPOSITE FOUNTAINS
Elkay Composite fountain provides an exremely durable, nonporous surface which resists staining. Care is very simple. Routine cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is normally needed to give many years of trouble free service. Cleaners left standing on the fountain surface can dull the surface finish. Be certain to rinse all cleaning agents completely and polish with a soft cloth.
Harsh abrasive cleaners are not required and should not be used.
Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple scratches and stains. Cigarette burns can normally be removed without noticeable effect. Deeper scratches or gouges can be corrected with fine grit sandpaper (240 grit then 400 grit) or a green Scotchbrite pad.
To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or like products will keep the finish looking like new.
97014C (Rev. E - 2/04)
PAGE 2
Page 3
This page left blank intentionally.
PAGE 3
97014C (Rev. E - 2/04)
Page 4
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
PART NO.ITEM NO.
LK464
112627543890
15005C 27201C 45362C 40045C 45358C 45366C 45751C 50986C 45382C 56087C 55973C 61313C 66399C 70022C 55996C 75554C 45387C A55139
100322740560
70012C 55978C 45736C
PARTS LIST
DESCRIPTION
Drain Screw - 10-24 x 1/2" PHTC Retaining Nut Bottom - Cover (EDFPW210JC) Strainer - Beehive (Gold) Hex Nut Ferrule - Drain Push Button - (Gold) Push Buttton Sleeve (Gold) Regulator Holder Orifice Assy (Gold) Push Button Extension Fountain - Green Marble (EDFPW210JC) Regulator Tube Assy - Bubbler Set Screw - #6-32 x 5/16" Strainer Threaded Insert Bubbler Assy Bubbler (Gold) Gasket - Black Locknut - 3/8 -18 Back Panel (EDFPW210JC) Nut - Regulator Mounting
11
20
TROUBLE SHOOTING & MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8" diameter or small diameter wire.
CAUTION: Do not file or cut orifice material.
Stream Regulator: If orifice is free of material deposits, regulate flow as
in instructions on page 2 (Step 7). If replacement is necessary, see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(See Figure 2, Page 1). To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4".
13
5, 7
19
21
22
NOTE: When installing replacement bubbler, tighten nut (item 22) Only to hold parts snug in position. DO NOT OVER TIGHTEN.
FIG. 4
912
3
14
10
SEE FIG. 5
SEE FIG.
4
15
23
1
8
16
FIG. 5
PRINTED IN U.S.A.
BASIN
6
24
2, 4, 18
17
FIG. 6
ELKAY MANUFACTURING COMPANY  2222 CAMDEN COURT  OAK BROOK, IL 60523  630.574.8484
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PAGE 4
97014C (Rev. E - 2/04)
Loading...