Elkay ECP8-2GQ Installation Manual

ECP8*2GQ
Refrigeration Package
INSTALLATION, CARE & USE MANUAL
INSTALLATION
1. Insure proper ventilation. In fully recessed drinking fountains be sure condenser faces louver panel and is
within 1/2” (13 mm) of louver panel when panel is in place.
2. Water inlet is 3/8” (10 mm) O.D. unplated tube . Contractor to supply connections as required.
3. Connecting lines to be made of unplated copper. Thoroughly ush all lines to remove all foreign matter
before connecting to cooler.
4. Connect cooler to building supply with a shut-off valve and install a 3/8” (10 mm) unplated water line between the valve and cooler. Remove burrs from outside of water line. Insert water line into bulkhead union until it reaches a positive stop, approximately 3/4” (19 mm).
NOTE: DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specied on cooler serial
plate. Never wire the compressor directly to the power supply.
IMPORTANT! INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building, or may occur away from the building. This grounding can cause electrical feedback into a water chiller, creating an electrolysis which causes a metallic taste or an increase in the metal con-
tent of the water. This condition is avoidable by using the proper materials indicated below. Drain ttings which are
provided by the installer should be plastic to electrically isolate the chiller from the building plumbing system.
START-UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which cooler is connected.
A steady stream ow assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory-set for 50°F water (± 5°) under normal conditions. For colder water, adjust screw
on item no. 5.
Ventilation: Cabinet louvers and condenser ns should be periodically cleaned with a brush, air hose, or vacuum
cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the overload protector.
Lubrication: Motors are lifetime lubricated. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring
seal. To remove tubing from the ttings, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into tting until it reaches a positive stop, approximately 3/4”.
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
RELEASE TUBE
1000002231 (Rev. A - 11/14)
ITEM
NO.
1 2 3 4 5
*6
7 8
9 10 11 12 13
PART
NO.
98724C
0000000244
98778C 55996C
98773C 1000002194 1000002195
31506C 0000000255
98776C
66703C
20282C
56237C
220V-240V/50Hz PARTS LIST
DESCRIPTION
kIT - EVAPORATOR REPLACE ASSY KIT - FAN MOTOR/BLADE//NUT/SHROUD KIT - HEATX/DRIER STRAINER KIT - COLD CONTROL/SCREWS COMPRESSOR SERV. PAK KIT - ELECT/RELAY/COVER/OVERLOAD POWERCORD
KIT - COMPR MTG/GROMMETS/CLIPS/STUDS
KIT - CONDENSER/DRIER DRIER BRACKET - FAN MTG SHROUD-FAN
ECP8*2GQ
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF THE
ABOVE WATER COOLERS OR ORDERS FOR REPAIR PARTS MUST INCLUDE MODEL NO. AND SERIAL NO. OF COOLER, NAME AND PART NO. OF REPLACEMENT PART.
13
3
12
1
2
11
9
6
8
4
7
5
10
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
1000002231 (Rev. A - 11/14)
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816