VANDAL RESISTANT BUBBLER KIT 97446C
1. Remove panel to gain access to the bubbler from under the basin.
2. Remove bubbler by either unscrewing nut under basin and removing tube from the quick
connect fitting (see Figure A below) or holding existing bubbler nipple and unscrewing
bubbler.
3. Remove any fittings on water tube to allow the new bubbler nipple to fit. The free end of
the copper tube must be 1/4 size with at least 3/4 of straight, round, and burr-free tube
required to insert into the bubbler nipple. If tube is not available, the adapter tube may
be soldered onto the existing tube to provided the proper connection.
4. Push bubbler nipple onto the 1/4 tube until properly seated, approx. 3/4.
5. Put rubber washer on the bubbler nipple then push nipple up through the hole in the
basin.
6. Apply thread sealer (not provided) to the bubbler nipple threads.
7. Assemble the bubbler to the bubbler fitting. Hold bubbler in desired position and tighten
nipple from under basin.
8. Operate the unit and check for leaks.
9. Re-assemble panel.
Figure A
PARTS LIST
PART NO.ITEM NO.
1
2
3
4
100322740560
15009C
45392C
62195C
DESCRIPTION
GASKET-BLACK .68 X 1.03
BUBBLER NIPPLE ASSY
BUBBLER
ADAPTER TUBE-CU 1/4 X 5.00
(IF REQUIRED)
3
BASIN
1
(IF REQUIRED)
4
2
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620