INSTALLATION, CARE & USE MANUAL
INSTALLATION
1. Insure proper ventilation. In fully recessed drinking fountains be sure condenser faces louver panel and is
within 1/2" (13 mm) of louver panel when panel is in place.
2. Water inlet is 3/8" (10 mm) O.D. unplated tube . Contractor to supply connections as required.
3. Connecting lines to be made of unplated copper. Thoroughly flush all lines to remove all foreign matter before
connecting to cooler.
4. Connect cooler to building supply with a shut-off valve and install a 3/8" (10 mm) unplated water line between the valve and cooler. Remove burrs from outside of water line. Insert water line into bulkhead union until it reaches a positive stop, approximately 3/4" (19 mm).
NOTE: DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE T O THE O-RINGS MA Y RESUL T .
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial
plate. Never wire the compressor directly to the power supply .
IMPORTANT! INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building, or may occur away from the building. This grounding can cause electrical feedback into a water chiller, creating an electrolysis which causes a metallic t aste or an increase in the metal content of the water. This condition is avoidable by using the proper materials indicated below. Drain fittings which are provided by the installer should be plastic to electrically isolate the chiller from the building plumbing system.
START-UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which cooler is connected. A steady
stream flow assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
TROUBLE SHOOTING & MAINTENANCE
T emperature Control: Factory-set for 50°F water (± 5°) under normal conditions. For colder water , adjust screw
on item no. 5. Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose, or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the overload protector .
Lubrication: Motors are lifetime lubricated. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring
seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4”.
WIRING DIAGRAM
OPERA TION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PULLING IT OUT HELPS TO
RELEASE TUBE
98058C (9/04)
ITEM NO.
1 2 3 4 5
6*
7 8
9 10 11 12 13 14 15 16 17 18 19
115V PARTS LIST
PAR T NO.
66534C 56237C 66576C 55996C 31513C 36094C 36158C 35768C 35959C
19037000 101516143550 100806740570
20282C 31490C 70018C 30664C 66703C 66743C 36208C
DESCRIPTION
EVAPORA TOR ASSY SHROUD - FAN HEAT EXCHANGER STRAINER COLD CONTROL COMPRESSOR SERV . P AK OVERLOAD COVER RELAY RELAY CLIP - COMP MTG STUD - COMP MTG GROMMET - COMP MTG BRACKET - F AN MTG FAN MOTOR NUT FAN BLADE DRIER CONDENSER POWER CORD
ECP8*1D, *2D, *3D
ITEM NO.
6*
7 9
14 19
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY . NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF
THE ABOVE WATER COOLERS OR ORDERS FOR REPAIR PARTS MUST INCLUDE MODEL NO. AND SERIAL NO. OF COOLER, NAME AND PART NO. OF REPLACEMENT PART.
220V 50/60HZ PARTS LIST
PAR T NO.
36092C 36085C 36174C 36195C 36050C 31431C 31430C 31506C
COMP SERV . P AK (60 HZ) COMP . SERV. P AK (50 HZ) OVERLOAD (60 HZ) OVERLOAD (50 HZ) RELAY (50/60 HZ) FAN MOTOR (60 HZ) FAN MOTOR (50 HZ) POWER CORD (50/60 HZ)
DESCRIPTION
3
13
17
1
10, 1 1, 12
6
16
2
14, 15
7, 8, 9
4
5
98058C (9/04)
18
19
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
ELKA Y MANUFACTURING COMP ANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484