WARNINGS AND PRECAUTIONS
ELITE ACTUATOR-1 REQUIRES POSITIVE STOPS TO BE INSTALLED ATOPENING AND CLOSING POSITIONS OF THE GATE IN ORDER FOR THE GATE OPERATOR TO FUNCTION.
NOTFOR INSTALLATION ON SMALLAND LIGHTGATES OR ANY GATE UNDER 4.5’ OR 1.5’ FRAME. INSTALLATION ON SUCH GATES WILLCAUSE DAMAGE TO THE GATE AND POSTS.
NOT FOR INSTALLATION ON ANY PEDESTRIAN GATES.
NOTFOR INSTALLATION ON ANY
PASSAGES OR DOORWAYS.
CAUTION: DO NOTINSTALLOPERATOR WITH ARM FULLYEXTENDED OR OPERATOR WILLLOCK UP. USE THE “C” MEASUREMENT.
CAUTION: DO NOTBEND THE WIRE CONNECTION
FROM THE OPERATOR. TO DO SO WILLCAUSE
THE WIRES TO EVENTUALLY BREAK.
WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS THE ELITE ACTUATOR-1 IS FOR VEHICULAR GATE USE ONLY
BE SURE TO READ AND FOLLOW ALL THESE IMPORTANT INSTRUCTIONS BEFORE INSTAL- LATION OF THE ELITE ACTUATOR-1. ELITE ACCESS SYSTEMS, INC. IS NOT RESPONSIBLE FOR IMPROPER INSTALLATIONS OR FAILURE TO COMPLY WITH LOCAL BUILDING CODES.
DO NOT I N S TA L L UPSIDE DOWN, A S WATER WILL GET IN VENT HOLES ON BOTTOM OF OPERATOR AND DAMAGE IT
DO NOT INSTALL NEXT TO SPRINKLERS OR ANY AREA THAT MAY EXPOSE BOTTOM VENTHOLES TO WATER.
WARNING:DO NOT LUBRICATE SHAFT. OIL CAN GETINTO THE MOTOR AND DAMAGE IT.
Page 3
OPEN TO THE OUTSIDE
GATE INSTALLATION & PREPARATION
CAUTION: DO NOTINSTALLOPERATOR WITH ARM FULLYEXTENDED OR OPERATOR WILLLOCK UP. USE THE “C” MEASUREMENT. NOTE ELITE ACCESS SYSTEMS, INC. IS NOT RESPONSIBLE FOR IMPROPER INSTALLATIONS OR FAILURE TO COMPLY WITH LOCAL BUILDING CODES. DRAWINGS ARE NOT TO SCALE.
Page 4
OPEN TO THE INSIDE
GATE INSTALLATION & PREPARATION
CAUTION: DO NOT INSTALL OPERATOR WITH ARM FULLY EXTENDED OR OPERATOR WILL LOCK UP. USE THE “C” MEASUREMENT. NOTE ELITE ACCESS SYSTEMS, INC. IS NOT RESPONSIBLE FOR IMPROPER INSTALLATIONS OR FAILURE TO COMPLY WITH LOCAL BUILDING CODES. DRAWINGS ARE NOT TO SCALE.
Page 5
STEP BY STEP INSTALLATION
STEP 1: POSITION AND LEVEL THE OPERATOR, BRACKETS AND PLATE (SEE GATE INSTALLA- TION AND PREPARATION). TACK WELD PLATE AND BRACKETS IN POSITION.
STEP 2: REMOVE OPERATOR AND FULLY WELD THE PLATE AND BRACKETS TOP, BOTTOM AND SIDES. CAUTION: WELDING WITH OPERATOR IN
PLACE MAY DAMAGE THE OPERATOR.
S T E P 6: POSITION THE OPERATOR SO T H E
PLATE ON THE POSTFITS BETWEEN THE OPEN- ING AT THE REAR OF THE OPERATOR. ALIGN THE HOLES AND TAP IN ONE PIN.
STEP 4: INSTALL THE POSITIVE STOPS FOR OPEN- ING AND CLOSING(THIS IS AN OPTIONAL ITEM - MODEL: “A PSA”). IF STOP IS CUSTOM MADE, USE SOME TYPE OF RUBBER GROMMETS OR PADS TO REDUCE NOISE.
STEP 5: DETERMINE THE LOCATION, MARK AND DRILL THE HOLES. USE 1/2” RED-HEAD BOLTS.
CAUTION: MOUNT THE POSITIVE STOP ON CON - CRETE ONLY.
STEP 3: MAKE SURE THE OPERATOR IS LEVEL OR THE OPERATOR WILLNOT FUNCTION PROP- ERLY.AN OFF-LEVEL INSTALLATION MAY CAUSE THE GATE OR OPERATOR TO FAIL PREMATURE- LY.
Page 6
STEP BY STEP INSTALLATION (cont.)
STEP 7: TO SECURE THE PIN, SNAP ON ONE RETAINING CLIP IN THE GROOVE AT THE BOT- TOM OF THE PIN.
STEP 8: POSITION THE OPERATOR ARM SO THE PLATE ON THE GATE FITS BETWEEN THE OPEN- ING AT THE FRONT OF THE OPERATOR. ALIGN THE HOLES AND TAP IN ONE PIN.
STEP 9: TO SECURE THE PIN, SNAP ON ONE RETAINING CLIP IN THE GROOVE AT THE BOT- TOM OF THE PIN.
STEP 10: GENTLY TAP IN PLACE THE PLASTIC KEY RELEASE COVER. NOT MANDATORY.
PLACEMENT OF ELITE ACTUATOR-1 ON GATE
FOR STRENGTH PURPOSES, THE FRONT BRACKET MUST BE WELDED IN AN AREA THAT CAN WITHSTAND HEAV Y FORCES. DO NOT WELD A CROSS BAR ON JUST A FEW PICKETS OR THE PICKETS WILL BEND. WELD A CROSS BAR ACROSS ALL OF THE PICKETS OR WELD THE FRONT BRACKET AT THE TOP OF THE GATE DIRECTLYTO THE FRAME.
Page 7
CONNECTING POWER
SINGLE GATE OPERATOR
CAUTION: DO NOT BEND THE WIRE CONNEC- TION FROM THE OPERATOR. TO DO SO WILL CAUSE THE WIRES TO EVENTUALLY BREAK.
PROPER GROUNDING IS IMPORTANT
Page 8
CONNECTING POWER
MASTER / SLAVE
OPERATOR #1
OPERATOR #2
CAUTION: DO NOT BEND
THE WIRE CONNECTION FROM THE OPERATO R . TO DO SO WILL CAUSE THE WIRES TO EVENTU- ALLY BREAK.
CAUTION: DO NOT BEND THE WIRE CONNECTION FROM THE OPERATO R . TO DO SO WILL CAUSE THE WIRES TO EVENTU- ALLY BREAK.
PROPER GROUNDING IS IMPORTANT
Page 9
CHOOSING MOVEMENT DIRECTION
CURRENT SENSOR ADJUSTMENT
ADJUST THE SENSOR POT. FOR MASTER (OR SLAV E ) SO WHEN THE GATE HITS THE POSITIVE STOPOR ANY O B J E C T THE GATE WILL STOP. NOTE: IF YOU ACTIVA TE THE OPERATOR AND THE GATE STOPS IN THE MIDDLE OF THE DRIVEWAY, THE SEN- SOR IS SET TOO SENSITIVE.
THE SENSORS MUST BE ADJUSTED WHILE THE GATE IS IN THE OPENING CYCLE.
Page 10
CHOOSING OPEN/CLOSE SHUT-OFF SYSTEM
Page 11
CONTROL BOARD OPERATION
1. Master Close Relay LED
2. Slave Close Relay LED
3. Slave Open Relay LED
4. Master Open Relay LED
5. Auxiliary torque
6. Radio Power Fuse
7. Board Power Fuse
8. Master Sensor Pot
9. Power LED
10. Master Sensor On LED
11. Motor Error LED
12. Slave Sensor Pot
13. Slave Sensor On LED
14. Timer LED
15. Timer Pot / 0 to 45 sec.
16. Timer On/Off Switch
17. J2 Plug
18. W2 Jump Wire
19. Radio Receiver LED
20. Safety Loop LED
21. Strike Open LED
22. Gate Armed LED / Alarm
23. Plug / Open Outside
24. Plug / Open Inside
25. Shut-off mode Jumper
Page 12
DRY CONTACT & RECEIVER WIRING
M O U N T RECEIVER INSIDE THE CONTROL BOARD BOX AS SHOWN USING VELCRO. NOTE THAT THE RECEIVER IS UPSIDE DOWN SO THE ANTENNA CAN FIT THROUGH THE HOLE AT THE BOTTOM OF THE CONTROL BOARD BOX.
Page 13
SAFETY LOOP INSTALLATION
Page 14
INTERFACING WITH HOUSE ALARM
A PRS
THE ELITE ACTUATOR-1 CAN BE INTERFACED WITH AN EXISTING HOUSE ALARM PANELAS AN ADDITIONAL ZONE.
USE LOW VOLTAGE WIRE 20 AWG
Page 15
OPTIONAL ALARM & STROBE LIGHT
Page 16
PHOTOCELL INSTALLATION
MASTER (or single gate operator)
TO REDUCE THE RISK OF INJURY, ELITE HIGHLY RECOMMENDS INSTALLING A PHOTOCELL SENSOR WHEN THE GATE OPENS TO LESS THAN 18” FROM A WALL OR ANY OTHER OBJECT. FOLLOW THE INSTALLATION INSTRUCTIONS PROVIDED WITH THE PHOTOCELL SENSOR FOR ACCURATE PLACEMENT OF THE PHOTOCELLAND THE REFLECTOR.
(IMPORTANT)
Page 17
PHOTOCELL INSTALLATION
SLAVE (or second gate operator)
(IMPORTANT)
Page 18
MAGNETIC LOCK INSTALLATION
REQUIRED FOR MAGNETIC LOCK INTERFACE INSTAL- LATION ARE: MAGNETIC LOCK, LOW VOL T AGE WIRES, AND 12V EXTERNAL RELAY (SOLD SEPARATELY).
12v - 5 Amp Contact Relay
* Normally Closed
*
12VDC
MAGNETIC LOCK
P/N:A MAGLOCK 12
24VDC
MAGNETIC LOCK
P/N:A MAGLOCK
12v - 5 Amp Contact Relay
* Normally Closed
*
Page 19
EMERGENCY KEY RELEASE
KEY RELEASE
(PROVIDED)
TO MOVE THE GATE DURING AN EMERGENCY OR POWER FAILURE, INSERTTHE KEY RELEASE
(STEP 1) INTO THE KEY RELEASE HOLE ON THE TO P OF THE OPERATOR. TURN THE KEY COUNTER CLOCKWISE TO RELEASE THE GATE.
MOVE THE GATE WITH YOUR HAND (STEP 2) TO THE FULL90° OPENING AND RE-LOCK THE OPERATO R ( S T E P 3) BY TURNING THE K E Y RELEASE CLOCKWISE. THE OPER- ATOR CAN NOW RESUME NORMAL OPERATION AS SOON AS POWER IS RESTORED (STEP 4).
STEP 1
STEP 2
STEP 3
STEP 4
90°
UNLOCK
RE-LOCK
Page 20
TROUBLESHOOTING
EXAMPLE: THE RADIO RECEIVER LIGHT IS ON, AND THE GATE IS STAYING OPEN. THIS MEANS THE RADIO RECEIVER IS BROKEN IN THE “ON” POSITION.
EXAMPLE: THE RADIO RECEIVER LIGHT IS NOT ON AND THE GATE WILL NOT OPEN WITH THE TRANS- MITTER. THIS MEANS THE RADIO IS BROKEN IN THE “OFF” POSITION.
HOW TO REMOVE CONTROL BOARD
DETACH THE OPEN INSIDE (OR OPEN OUTSIDE) PLUG AND THE J2 PLUG. REMOVE THE THREE, LONG HEX-SHAPED NUTS AND REMOVE CONTROLBOARD. REVERSE THIS PROCESS TO INSTALL THE CONTROL BOARD.
THE THREE
TROUBLESHOOTING LED
INDICATORS FUNCTION
LIKE THE EXAMPLE BELOW.
Page 21
ELITE ACTUATOR-1™ PARTS LIST
MAINTENANCE
THE ELITE ACTUATOR-1™ IS DESIGNED TO BE VERY LOW IN MAINTENANCE. YOU MAY HAVE TO PERIODICALLY GREASE HINGES ON YOUR GATE. ANY SERVICE MUST BE PERFORMED BY AN AUTHORIZED SERVICE TECHNICIAN.
Q006 - Control Board Nuts (set) Q186 - Master Slave Control Board Q187 - Single Control Board Q188 - Operator Q189 - Control Board Box Q190 - Cover Q191 - Key Release
Q192 - Front Mounting Plate, Retaining
Rings, Pins, Back Mounting
Plate, and Key Release Cover Q193 - Act-1 Motor Harness Q194 - Act- M/S Motor Harness Q195 - Act- Radio & Accessory Harness
Q186
Q187
Q189
Q191
Q190
Q192
Q188
Q192
Q006
Q195
Q193 Q194
Page 22
FEATURES AND SPECIFICATIONS
MOTOR - 120V, 60Hz, 3 amp - automatic reset system. WORM GEAR REDUCTION - 27:1, Steel and alloy bronze gears. CYCLES - Complete 90° cycle - 30 per hour with ambient temp. of 90°. CAPABILITIES - Maximum gate size 14' wide, 500 lbs. TRAVEL SPEED - 18 to 21 seconds 90° opening. DIMENSIONS - L (open) 44
1 / 2
", L (closed) 29 14", H 7 1 2", W 4 1 2".
SENSOR - Causes the gate to stop when it makes contact with an object while opening or closing.
TORQUE - 450 lbs. of torque. MODULAR BOARD - Uses LEDs to indicate all input and output functions
of the gate operator including motor error. OUTPUT SHAFT - 1
1
4" stainless steel.
FINISHING - Aluminum die-cast body with epoxy paint and stainless steel shaft for excellent corrosion resistance.
EMERGENCY RELEASE - Convenient key release to operate the gate manually in case of power failure.
Loading...