Elite 799, 800, 801, 802, 803 User Manual

Page 1
ELITE
AIR PUMPS
799 / 800 / 801 / 802 / 803
LISTED
85E3
E114229
Page 2
On your purchase of an ELITE air pump. So that you may enjoy your new air pump to the fullest, please take a few moments to read this instruction booklet to become familiar with the installation and operation procedures. Be certain to read the SAFETY INSTRUCTIONS before using your air pump.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To guard against injury, basic safety precautions
should be observed, including the following.
1. For the complete enjoyment, use and understanding of this product
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
and all important notices on the appliance before using. Failure to do so may result in damage to the unit.
2. Danger – To avoid possible electrical shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs yourself; return the appliance to the manufacturer for service or discard the appliance.
A. DO NOT immerse in water. If the appliance falls into the
water, DON’T reach for it! First unplug it and then retrieve it.
If electrical components of the appliance get wet, unplug the appliance immediately. (Non-immersible equipment only)
B. Carefully examine the appliance after installation. It should not
be plugged in if there is water on parts not intended to be wet.
C. Do not operate any appliance if it has a damaged cord or plug,
or if it is malfunctioning or if it is dropped or damaged in any manner. The power cord of this appliance cannot be replaced: if the cord is damaged, the appliance should be discarded. Never cut the cord.
D. To avoid the possibility of the appliance plug or receptacle
getting wet, position aquarium stand and tank to one side of a
Page 3
wall mounted receptacle to prevent water from dripping onto the receptacle or plug. The “drip-loop” (see illustration) should be arranged by the user for each cord connecting an aquarium appliance to a receptacle. A “drip-loop” is that part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water travelling along the cord and coming in contact with the receptacle. If the plug or receptacle does get wet, DON’T unplug the cord. Disconnect the fuse or circuit
breaker that supplies power to the appliance, then unplug and examine for presence of water in the receptacle.
3. Close supervision is necessary when an appliance is used by or near children.
4. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and the like.
5. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
6. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition.
7. Do not install or store the appliance where it will be exposed to weather or to temperatures below freezing.
8. Make sure an appliance mounted on a tank is securely installed before operating it.
9. Read and observe all the important notices on the appliance.
10. If an extension cord is necessary, a cord with a proper
rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
SAVE THESE INSTRUCTIONS
Drip-Loop
Check
Valve
Page 4
INSTALLATION:
The air pump should be installed by following either of the two recommended methods:
1. Place the air pump on a surface lower than the water level
of the aquarium. To avoid damage from accidentally spilled water, do not place the air pump directly below the aquarium.
Important: It is recommended to always use a Check Valve (sold separately) in the air line between the air pump and the aquarium. The Check Valve will help prevent water from siphoning out of the aquarium through the air hose and into the pump in the event of a power failure, or when removing filters and other air-driven accessories from the aquarium.
2. Place the air pump on a surface higher than the water level,
such as a shelf. The surface should be at least 12 inches (30 cm) higher than the water level of the aquarium, but not be positioned directly above the aquarium. The surface should have a raised edge to prevent the air pump from sliding off. Use a Check Valve (sold separately) in the air line between the air pump and the aquarium to prevent back-siphoning.
Once the air pump has been installed, do the following:
1. Attach one end of the air line tubing (sold separately) to the air outlet(s) on air pump.
2. Attach the other end of the air line tubing to filter(s), airstone(s), ornament(s) or any other air-driven aquarium accessory. Ensure that the airline tubing has no restrictions or kinks.
3. Plug air pump into outlet. Be sure to allow for a “drip loop” (see illustration).
Check Valve
Check
Valve
Drip-Loop
Drip-Loop
Page 5
INSTALLATION TIPS:
• The pump should be placed in a location which is dry and
relatively free from dust . Do not place the air pump on carpet, as fibers might collect on the pump and clog free­flowing air from entering pump. This will reduce the air output and the service life of the pump.
• Air control valves with multiple outlets may also be used to
power additional apparatus in the aquarium. When using multiple air valves, it is recommended to have one more outlet than required by the accessories; this will be used to bleed overproduction of air due to back pressure build up. For more information about back pressure see (BACK PRESSURE).
• Air Pumps can be used to operate a variety of aquarium
accessories such as air stones, corner filters, under gravel filters, and ornaments. Follow installation instructions for your particular aquarium accessory product.
CAUTION:
Care must be taken during installation to ensure that water cannot siphon out of the aquarium through the air hose and damage the air pump. To prevent back-siphoning when removing filter(s), air stone(s), ornament(s) or any other air­driven aquarium accessory from the aquarium, do the following:
1. Install a Check Valve
2. Leave the pump running while you disconnect the tubing
from the pump. Disconnect tubing and tape this end of the tubing to the very top frame of your aquarium.
3. Filter(s), air stone(s) and other air-driven ornaments can now
be safely removed from your aquarium.
AIR FLOW ADJUSTMENT
In order to achieve correct airflow, a balance between the valve setting and the pump output is necessary. The ideal setting is obtained by minimum back pressure or nonrestriction of flow of air. Never physically restrict the output of the pump. Restriction causes damage to the diaphragm. (SEE BACK PRESSURE). Adjust air valve output as required.
Page 6
To regulate air volume using an air control valve with multiple outlets, it is recommended to have the last valve available to release excess air pressure build up (see BACK PRESSURE). In regulating the air pressure, it is best to work from the valve farthest from the input of the air valve. Remember to have the last valve completely closed so as not to lose any air pressure. Proceed to make adjustments on the remaining valves. Once the adjustments are complete slowly open the last valve to the point where no loss of air output is noticed from the items controlled by the other valves. To achieve and maintain an equal balance of air pressure to the accessories in the aquarium, further adjustments of the air valve may be required depending on the items powered by the air pump.
Note: If the first valve on the air control assembly is fully opened, air volume to the remaining outlets will be reduced.
To alleviate excess air pressure or overproduction of air, it is recommended to open the last valve every 2 weeks, or when required. In doing this, you will increase the life of the pump and diaphragms by preventing premature wear.
BACK PRESSURE
Back pressure is the buildup of pressure on the diaphragm due
Page 7
to restricted air flow. This occurs when excess air is produced by the air pump, or when the air channels are inadvertantly blocked. Back pressure over time resulting from clogged air stones or other air system blockages and restrictions will cause the diaphragm to expand or rupture. An expanded diaphragm leads to a loss of air volume while a rupture results in the total loss of air.
MAINTENANCE
(EXTERNAL APPEARANCE) Remove dust and grime with a soft, damp cloth. Do not immerse pump in water.
AIR STONE, AIR LINE, AND ORNAMENT MAINTENANCE
This pump requires no regular internal maintenance during its life. The rest of the air system should be periodically checked and cleaned.
• Air lines should be carefully inspected whenever standard
aquarium maintenance is performed. Adjust, or if required, replace all sections which are pinched, kinked, or otherwise damaged.
• All attached air-driven aquarium ornaments should be regularly
maintained. Algae growths should be removed from moving parts and kept as clean as possible. Internal air tubes should be cleaned.
• Air stones should be kept clean and free of debris or algae
build-up. The ideal situation is to replace them every month, alternating with an extra set which has been dried over that period and cleaned before being placed in the aquarium. Two complete sets of air stones alternately changed each month will extend the life of the air stones and help keep back pressure to a minimum.
Clogged airstones and air-driven aquarium ornaments will lead to low air pressure output and also reduce the life of the diaphragms.
Page 8
TROUBLESHOOTING TIPS
If the air pump fails to produce air, check the following:
1. Ensure that the air pump is plugged in.
2. Ensure that there are no blockages in the air hose assembly
and that all valves allow air passage. If no air is produced by the accessories in the aquarium, remove the airline from the pump and ensure that air is being produced.
3. If the air pump produces no output, the most common
problem encountered with any air pump is a ripped or weakened diaphragm. Inspect the diaphragm for tears or rips. Any opening in the diaphragm will make it impossible for the pump to produce air for aeration purposes. Always inspect the diaphragm first before replacing other parts in the pump.
REMOVING THE PUMP
Whenever the air pump must be shut off and removed from the aeration system, always take off the air line before the pump is unplugged. This will prevent water from siphoning back into the pump. If the air line cannot be removed before unplugging the power cord, raise the pump above the water level.
Page 9
REPLACEMENT PARTS
Repair kits for all wearable parts are available for all ELITE, MAXIMA, MAXIMA-R, and OPTIMA Air Pumps. These can be easily obtained at your local aquarium and pet supply store. Failure of the electric coil, or any other electrical part requires proper service, and should be returned to the manufacturer for repairs or replacement (see warranty for full details).
Art. #A-18030: Elite 799 Repair Kit Art. #A-18080: Elite 800/801/802 Repair Kit Art. #A-18190: Elite 803 Repair Kit Art. #A-18285: Maxima/Maxima-R Repair Module Art. #A-18330: Maxima/Maxima-R/Optima Repair Kit Art. #A-18335: Optima Repair Module
Page 10
ACCESSORIES
Elite Check Valve
Art. #A-1165 Prevents damage to air pump from back­siphoning in the event of electrical power failure or when removing air-driven ornaments and accessories from aquarium.
Elite Air Control Valves
Customize your aquarium set-up with Elite Air Control Valves. Art. #A-1178:
Elite 2-way Air Control Valve
Art. #A-1179:
Elite 3-way Air Control Valve
Art. #A-1180:
Elite 4-way Air Control Valve
Art. #A-1181:
Elite 5-way Air Control Valve
Elite Flex-Air Tubing
Soft, pliable tubing that will not harden. Remains kink-resistant for long periods. For filters, pumps, valves, air-driven aquarium ornaments and accessories. Art. #A-1123: Elite Flex-Air Tubing
3 M (10 ft)
Art. #A-1124: Elite Flex-Air Tubing
6 M (20 ft)
Page 11
QUESTIONS?
If you have a problem, or have questions about the operation of this product, please let us try to help you before you return the product to your dealer.
Most problems can be handled promptly with a toll-free phone call. Or if you prefer, you can contact us on our web site at
www.hagen.com
When you call (or write), please have all relevant information, such as model number and/or part numbers available, as well as the nature of the problem.
CALL US ON OUR TOLL FREE NUMBER: 1-800-724-2436
Between 8:30 a.m. and 4:00 p.m. Eastern Time. Ask for Consumer Service.
FOR AUTHORIZED GUARANTEE CONSUMER SERVICE: Return unit with dated receipt plus $5.00 for shipping and handling to: Rolf C. Hagen (U.S.A.) Corp., Consumer Repair, 50 Hampden Road, Mansfield, MA. 02048
WARRANTY
ELITE Air Pumps are guaranteed against defects in material or workmanship under normal aquarium usage and service for as long as you own your pump. We offer a Lifetime Limited Warranty on all non-rubber parts which means that the pump will be repaired or replaced at the manufacturer’s discretion, free of charge, when the complete pump is returned with proof of purchase and postage paid. Please include $5.00 to cover shipping and handling. This warranty does not apply to any pump which has been subjected to misuse, negligence, or tampering. No liability is assumed with respect to loss or damage to livestock or personal property irrespective of the cause thereof.
Distributed by: U.S.A.: Rolf C. Hagen (U.S.A.) Corp., Mansfield, MA. 02048
Printed in China USA-UL
Page 12
WARRANTY REGISTRATION CARD
Return to validate your guarantee.
Or, if you prefer, you may register on our web site at www.hagen.com
Name:
Address:
City: State:
Zip Code: Telephone:
Date Purchased:
Store:
City: State:
Was this a gift? YES NO
Is this your first aquarium? YES NO
Size of Aquarium:
Type(s) of Fish:
ELITE 799 (A-799)
ELITE 800 (A-800)
ELITE 801 (A-801)
ELITE 802 (A-802)
ELITE 803 (A-803)
MAXIMA (A-805)
MAXIMA-R (A-806)
OPTIMA (A-807)
Loading...