Elinchrom Style BX 100, Style BX 400 Operating Manual

Page 1
English
Multivoltage
90/260V
elinca sa switzerland www.elinchrom.com
Operating Manual
Elinca S.A Style BX 01.09.2008 ENG (73286) Printed in Switzerland
Style BX 100/400
Page 2
1
P.S: Technical data subject to change.
The listed values are guide values which may vary due to tolerances in components used.
Introduction 2
Declaration of conformity, disposal and recycling, CE marking 3
Safety notice and precaution 4
Operating instructions 5
Control Panel 6
Switch and Fuse 7
Modelling Light 8
Digital power display, Photo-cell 9
Synchronisation, Wireless Remote control and ash triggering 10
Acoustic signal 10
Troubleshooting 7, 10
Flashtube replacement 11
DVD, «The beginner’s guide to light» 11
Technical Data 12
Elinchrom Accessories 13
Guarantee 14
Table of contents
Page 3
2
The quality of light and exceptional performance is the result of long research, application of demanding principles, the long experience of ELINCHROM in lighting products for the studio and the utilization of the latest technology in this area.
Totally integrated to the range of the ELINCHROM ashes, the Style 100BX - 400BX units
maintain the traditional look and function that is ELINCHROM.
The control provides continuously variable adjustment of the modelling lamp and the ash
power with precision over 5 f-stop, from full power 1/1 to 1/16 th.
Style 100BX - 400BX
The Elinchrom Style BX is manufactured by Elinca S.A. CH -1020 Renens/Switzerland
Dear Photographer,
Thank you for buying your Style BX compact ash unit. All Elinchrom products are manufactured using the most advanced technology. Carefully selected components are used to ensure the highest quality and the equipment is submitted to many controls both during and after manufacture. We trust that it will give you many years of reliable service.
All Style BX ash units are manufactured for the studio and location use of professional photogra- phers. Only by observance of the information given, can you secure your warranty, prevent possible damage and increase the life of this equipment.
Note:
This equipement has been tested and found to comply with the limits for a class B digital device, pursuant to Part
15 of the FCC Rules and meets all requirements of the Canadian Interference-Causing Equipement Regulations.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipement generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipement
does not cause harmful interferences to radio or television reception, which can be determined by turning the
equipement off and on, the user is encouraged to correct the interferences by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipement and receiver.
- Connect the equipement into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ELINCA S.A. is not responsible for any radio or television interference caused by unauthorised modications of
this equipement or the substitution or attachment of connecting cables and equipement other than those specied
by ELINCA S.A. The correction of interference caused by such unauthorised modication, substitution or
attachment will be the responsibility of the user.
FCC Class B Compliance Statement
Introduction
Page 4
3
CE marking
The shipped version of this device complies with the requirements of ECC directives 89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage directive».
Notational Conventions
The meaning of the symbols and fonts used in this manual are as follows:
Pay particular attention to text marked with this symbol. Failure to observe this warning endangers your life, destroys the device, or may damage other equipement
Supplementary information, remarks, and tips follow this symbol. Text which follows this symbol describes activities that must be performed in the order shown.
«Quotation marks» indicate names of chapters or terms
!
i
Disposal and recycling
This device has been manufactured to the highest possible degree from materials which can be recycled or disposed of in a manner that is not enviromentally damaging. The device may be taken back after use to be recycled, provided that is returned in a condition that is the result of normal use. Any components not reclaimed will be disposed of in a environmentally acceptable manner.
If you have any question on disposal, please contact your local ofce or your local ELINCHROM
agent (check our website for a list of all ELINCHROM agents world wide).
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Product name: Professional Studio Flash unit
Trade name: ELINCHROM
Model number(s): Style BX 100/400
Name of responsible party: Elinca S.A
Av. De Longemalle 11 1020 Renens / Switzerland
Phone : +41 21 637 26 77
Fax: +41 21 637 26 81
We, ELINCA S.A., hereby declare that the equipement bearing the trade name and model number
specied above was tested conforming to the applicable FCC rules, and that all the necessary steps
have been taken and are in force to assure that the production units of the same equipement will continue to comply with the Comissions requirements.
Declaration of conformity
Page 5
4
• Transport the ash unit with care and only in its original packaging or another corresponding packaging t to protect it against knocks and jolts.
• Transport only in complete discharged conditions. Wait a minimum 30 minutes after removing
from mains supply before packaging and transportation.
• Never drop the ash unit (danger of glass breakage)
Power cable
To guarantee safe operation, use the cable supplied.
• The cable has to be HAR-certied or VDE-certied. the mark HAR or VDE will appear on the outer
sheat.
• The cable set must be selected according to the rated current for your ash unit.
• Do not use a spider box to connect one or more ash units.
!
• Flash systems store electrical energy in capacitors by applying high voltage.
• For your safety, never open or disassemble your ashes.
• Only an authorised service engineer should open or attempt to repair the units.
• Internal defect charge capacitors may explode whilst the unit is in use, neve switch on a not proper working ash unit.
According to safety regulations, we draw your attention to the fact that these
electronic ash units are not designed for use outdoors, in damp or dusty conditions and should
not be used after being exposed to sudden temperature changes causing condensation. They must always be connected to an earthed (grounded) mains supply. On no account should any object be inserted into the ventilation holes. The units may retain an internal charge for a considerable time even though disconnected from the power supply.
• Do not use in restricted areas (like hospitals, etc.).
• Do not use in explosive environnements.
• Flash tubes and modelling lamps in use are very hot!
• Never touch a ash tube or lamp before the unit cooled down and is disconnected from
the mains (min 30mn).
• Do not re ashes from short distance (less than 1m) directed to a person and avoid looking directly into the ashlight!
• Keep (min 1m) distance to ammable materials.
• Keep generally distance to operating units.
Safety notice
Transport
Flash Tubes and Modelling lamps
Page 6
5
3
1
6
11
12
The units Style BX (Multivoltage) are adapted for operation on 90 - 260V/50 - 60Hz.
Before connecting for the rst time, check to make sure that your Modelling lamp coincides
with the voltage line. They must always be connected to an earthed ( grounded) mains supply.
All Style BX units have a bayonet mount and locking ring reector tting, for xing all Elinchrom and
Prolinca accessories.
Mount the unit securely to a suitable stand or support.
Remove the black protective cover (note: rst turn the locking ring A as shown, then rotate the black cap cover B in the same direction). Fitting a reector or accessory is the reverse of this action. DO NOT operate the unit without rst removing the black protective cover.
1.Check that the modelling lamp voltage is correct.
2.Check that the mains switch (3) is in the OFF ("O" position).
3.Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET
4.Using the mains SWITCH (3) and switch the unit ON ("I" position).
5.Connect the synchro cord on the socket (6).
6.Select the power with the touch pad (11 - 12)
Operating instructions
C
A
B
Locking ring
Handle
Tilthead with locking umbrella holder
Protective cover (26124)
Before you start !
Page 7
6
Overview of controls
1. Mains inlet socket
2. Mains fuse (slow blow)
3. Mains light up on/off switch
4. Modelling fuse (fast blow)
5. Open-ash
6. Synchro-sockets + jack 3.5 mm
7. Digital power display and charge/discharge indicator
8. Acoustic recharging signal (Beep)
9. Slave cell switch on/off
10. Photocell receptor
11. Power adjustment in 1/10 f-stops, with ADF
12. + Power adjustment in 1/10 f-stops
13. Modelling lamp switch (on/off free or prop)
14.+ Modelling power control
15. - Modelling power control
16. Tilt head clamp
17. Knurled clamp screw
18. Handle
19. Stand 5/8-inch socket
20. Umbrella tube (only for EL umbrellas, diameter 7 mm)
21. Supplementary locking for others umbrellas
Control Panel
9
5
8
6
10
7
13
1
2
17
4
3
16
18
1921
20
12
11
14 15
Page 8
7
2
3
1
Mains fuse
Modelling fuse
Mains switch
(Only tempered)
Mains socket
4
Mains Supply
With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug
of the original ELINCHROM mains cord into the mains socket (1).
Mains Switch
The switch should light up when the compact is switched on ("I" position). (Switch off before removing the mains cord).
Troubleshooting
If the on/off switch (3) is ON ("I" position) but not illuminated, switch off the unit and check the mains fuse (2). If failed replace with the correct fuse and switch ON the unit. This unit is protected by a thermal circuit breaker to avoid overheating.
Should this occur, the unit turns off automatically and cannot be red. After a break for cooling, the ash will be ready again for operation.
See page 11: Troubleshooting This equipment is not user serviceable and contains high voltages which are dangerous. In the event of failure, please return the unit to an authorized Elinchrom service station.
Mains Fuse
Standard type 5 x 20 mm, (use only tempered fuse) 8 AT (code 19022) for Style 100BX and Style 400BX
Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and turn the fuse holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately upon reconnection, return the unit to an ELINCHROM service centre for a check-up. (N.B. Please don't forget to check the correct rating of the fuse !).
Fuse for modelling light
Fast type 5 x 20mm, 4 AF Switch off the unit and replace the blown fuse with a new one of the correct rating. The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore
the ash tube.
Switch and Fuse
Page 9
8
Modelling lamps and fuse for 90/140V
Unit Modelling lamp Code Socket Fuse Code
Style 100BX 150W Halostar 23019 E27 4AF 19035
Style 400BX 150W Halostar 23019 E27 4AF 19035
Option: 150W Halogen 23031 GX 6,35 4AF 19035
Option: 200W Halogen 23033 GX 6,35 4AF 19035
The touch pad (14) controls the modelling lamp on/off and the proportional light. Select the power with the touch pad (15). The modelling light output (100%) is achieved when the power value is set to maximum. Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the
light output is proportional to the selected ash power. For all types of Style BX compact ash units use only 250 W MAX. lamps
Modelling light for mains voltage 190/260V
Use 150W/240V halostar, code 23035 or 200W/240V halogen GX 6.35, code 23034
If the modelling lamp does not illuminate, this may be due to the following:
1. The lament is broken after long use *(replace lamp and fuse)
2. The lament is broken after shock *(replace lamp and fuse)
3. An internal component failure, *(return the unit to customer service)
* Action required:
Modelling Light
This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp
300W, GX 6.35 (code 23022) for Style 100 and 400 BX units.
GX 6.35 E27
Page 10
9
10
Photocell receptor
5
Test and ready
9 Cell
Modellling light controls
Power display
The actual ash power is displayed in a f-stop compatible format. The power range is 5 f-stops. The digital display, provides continuous power indication of the ash
and modelling lamp. The controls cover a continuous output range from full power 1/1 to 1/16th in 1/10th, f-stop intervals.
During charging or discharging, the display "ashes". In case of overheating or malfunction, the
display shows «ER» for error.
Note:
The "Style 100BX - 400BX" units have an integrated discharge system, protected by a thermic switch.
To avoid overheating, lower power settings of more than 2f-stop, can be discharged manually by releasing
the ash with the «Test» touch button.
The photocell is actived when the green LED (on the touch pad 9) is illuminated.
When switched ON, the unit can be remotely triggered by another ash unit !
The Style BX photocell is specially designed to work under ambiant light conditions in your studio. Direct light or other strong light sources may reduce the sensitivity of the cell.
In difcult situations e.g. blinding, sunlight or obstacles, the additional cell with 5 m cord
(extensions available) solves most problems.
Digital power display
Photocell
Page 11
10
EL-Skyport triggers ashes without sync cords over a distance of approximately 100 m. Further detailed information please nd under :
www.elinchrom.com / Products / RX Multi Remote
Open ash "test"
Having pressed the touch pad to release a ash, the green «READY» light will
appear again once the unit is recharged. If the green light does not appear the charge system could be defective. Please contact and send to an authorized Elinchrom service.
Audible recharge signal
Select the function with the touch pad (8), the green indicator appears. Once recycled an acoustic signal indicates that the compact unit is ready.
5
6
Sync
Test and Ready
8
Beep
EL-Skyport Universal Set
(19360)
Transmitter
Universal receiver
The standard socket 3.5 mm mini-jack (6). N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets. ELINCHROM uses the low voltage (5 V) for security reasons.
Troubleshooting
1. The mains switch (3) is ON ("I" position), but not light up:
• Switch OFF the unit and change the mains fuse (2)
• Use only time-lag fuse (16 AT), corresponding to the Style RX model
2. The switch (3) is lit, the open ash ready is lighting up but does not function.
• The ashtube in the ashhead may be faulty (see page 11)
• If replacing the ashtube does not solve the problem, the cause could be a
component failure => please return the unit to an authorised Elinchrom service.
3. The ON/OFF switch (3) is lit but the open ash signal (6) is not lit
• Temporary break for overheating, caused by fast ash sequences or ventilation
slots obturated
• Fan cooling defective => the unit turns off automatically and cannot be red any more. After a break for cooling, the ash is ready again for operation.
• If after several minutes of break for cooling the ready signal (6) is not lit, the cause
could be a component failure. However, high voltage may remain on the capacitor circuits. => DO NOT ATTEMPT TO REPAIR THE UNIT. In this case please send the unit to an authorised Elincrom station.
Cordless ash control
Sychronisation socket
Page 12
11
If the unit does not ash but the ON/OFF switch indicates that there is power, it could be that the ash tube needs replacing.
Note:Flash tubes (Swiss quality) have a long life with average use, but multiashing in long sequences can
cause overheating of the electrodes leading to premature ageing, or perhaps the astube is broken or cracked.
remove the tube
Stand
correctly aligned
contact with
security spring
Plug- in ashtube
(made in Switzerland) (code 24029)
The Beginner’s Guide To Light / 72404
Only in English available. Your DVD Guide to better pictures, show how easy studio photography can be.
Learn about ash units and why studio ash is just the better light source for
portrait and universal photography. Set-
ting up and controlling ash lights and
how to use umbrellas, softboxes, snoots and grids. Have a look and enjoy the passion of photography. Presented by Chris Burfoot.
To replace the ash tube:
1. Switch off the mains switch
2. Remove the mains cable
3. Take the unit from its stand or lay it horizontally on a rigid surface. It will need to
be held rmly whilst removing and replacing the tube.
4. Allow the ash tube and modelling lamp to cool
for several minutes. They may be very hot.
5. Carefully remove and store the modelling lamp.
6. Put on the protective glove delivered with
your ash tube and remove: A - rst the security spring trigger B - the ash tube, by rmly pulling it away from the unit.
If the tube is broken, avoid cutting yourself and the glove. If the only part to grip is the electrode (e.g. a totally smashed tube), withdraw using insulated pliers or pincers.
There is a full discharge security circuit tted, but
if the unit has had a heavy fall, internal damage disconnecting a circuit could possibly happen.
7. Take the new ash tube, code 24029 for Style 100 BX - 400 BX. A glove or "plastic protection" MUST BE USED - contact with your ngers on the glas,
will cause dark markings on the tube when it is used.
8. Check that the tube is correctly aligned (central) and that the trigger contact is gripping
the tube, rex the security spring.
9. Re-connect and test the unit as usual.
Flashtube replacement
Training with Elinchrom lighting
Page 13
12
Flash power J(Ws) 100 400
Power supply V 90/260 90/260
F-stop, 1m, 100 ISO, with reector 48° 32,5 64,5
Control range J(Ws) 5-100 25-400
Recycling time (230 V) s 0,2-0,5 0,3-1,1
Flash duration (t 0,5) 1/1 s 1/1700 1/850
(t 0,5) 1/16 s 1/1150 1/450
Modelling output W 150 150
Voltage across sync cable V 5 5
Connected load A/VA (W) 8/2080 8/2080
Radio interference suppressiv CE-IEC 491 EN 60 555 - EN 61 000 - 4 - 2/3/4/5
Dimension length x diam. cm 21x14 21x14
Weight kg 1,55 1,9
• Mains switch
• Controls for: modelling on/off, cell on/off, acoustic signal on/off.
• Flash and modelling power control.
• «X» synchro jack socket 3,5 mm.
• Mains inlet socket and two fuses (Mains and modelling).
• Locking bayonet ring for accessory and reector tting
• Tilthead whit 5/8" - inch stand socket
• Thermal safety
• User replaceable ashtube UV coated (5650°K)
• Halogen modelling lamp 150W, with E27 tting, or optional alternative
*200W/GX6.35 with adaptator code 23101.
• Silent fan cooling
• Auto dumping function. Automatic discharge of ash power
• Central umbrella tube plus external tting
• Acoustic recharging signal
• Mains cable
• Synchro cord of 5m (jack 3.5mm plug)
• Protective cover
• Total compatibility with all Elinchrom accessories
• Very fast recycling time
• Very short ash duration
Tolerances and specications conforming to IEC and CE standards. Technical data subject to change
without notice.
Features
Technical data 100BX 400BX
Page 14
13
Sin gl e u nit s d o not in clu de Re fle cto rs - P ro duc t r ang e a nd sp eci fic at ion s s ubj ect t o c han ge. No g uar ant ee fo r m isp rin ts.
EL-Skypo rt RX Trigger Set 19362
Digital RX 2400
230V: 10258
110V: 10257
Digital RX 1200
230 V: 10256
110 V: 10255
EL-Skypo rt RX Trigger Set 19362
Digital 1500 AS
230 V
10248
110 V 10247
Digital 3000 AS
230 V
10254
110 V 10253
EL-Skypo rt Univers al trigge r Set 19360
EL-Skypo rt Univers al trigge r Set 19360
Classic 3000
230 V
10226
110 V 10225
Style RX 300
230 V: 20625
110 V: 20725
Style RX 600
230 V: 20626
110 V: 20726
Style RX 1200
230 V: 20627
110 V: 20727
Entr y level Com pact s P ro Comp acts
Pro Flas h Head
Entr y Level Fla sh H eads
H.D. Pro Flas h H eads
Power Fl ash Head s
Effe ct L ights
RX P ro C ompacts Batt ery Pow er Packs
Power Pa cks
Ranger S nappy
19288
Ranger R X Speed
10265
Ranger R X
10263
Ranger R X Speed AS
10267
Ringflas h 1500
20493
Ranger A Head
20101
Ranger S Head
20100
EL-Skypo rt Transceive r
Adapter
19374
Adapter cable
11095
Mini S
230V : 20106
110V : 20105
Mini A Speed
230V : 20104
110V : 20103
Digital SEE
230V : 20172
110V : 20173
Digital SE
230V : 20174
110V : 20175
Digital S
230V : 20150
110V : 20149
A 3000 N Speed
230V : 20168
110V : 20167
Twin X4
230V : 20180
110V : 20181
X 6000 N
230V : 20182
110V : 20183
Digital RE
230V : 20170
110V : 20169
Ringash 3000
230V & 110V : 20494
Fresnel Spot SPP 6000
Rotalux Square
70 x 70 cm
26178
Rotalux Square
100 x 10 0 cm
26179
Rotalux Recta
70 x 90 cm
26175
Rotalux Recta
90 x 110 cm
26176
Rotalux Strip
35 x 90 cm
26180
Rotalux Strip
50 x 130 cm
26181
Rotalux Octa
100 cm
26183
Rotalux Octa
135 cm
26184
Rotalux Deep Octa
100 cm
26185
Budget U mbrella Si lver
83 cm
26350
Pro Umbrel la White
85 cm
26372
Pro Umbrel la Transluce nt
85 cm
26371
Pro Umbrel la Transluce nt
105 cm
26374
Pro Umbrel la Gold
105 cm
26377
Pro Umbrel la Silver /Gold
105 cm
26378
Pro Umbrel la Silver
105 cm
26361
Pro Umbrel la Bronze
105 cm
26379
Pro Umbrel la Blue
105 cm
26380
Pro Umbrel la White
105 cm
26375
Budget U mbrella Trans lucent
83 cm
26351
Compact Reflector
21 cm 65 °
26140
Grid Ref lector
18 cm 60 °
26144
Standard Reflector
21cm 50°
26141
Colour G els 21 cm
26243
Grid 18 cm
30°
26100
20° 26101
12° 26102
Colour G els 21 cm
26243
Barndoor set 21
cm
26037
Grid 21 cm
30°
26052
20° 26053
12° 26054
26055
Barndoor set 26
cm
26040
Polarizi ng Filter 26
cm
26248
Polarizi ng Filter 21
cm
26244
High Per fomance
Reflecto r 26 cm 48 °
26137
Varistar R eflector
24 cm 90 °
26164
Reflecto r 16 cm 90 °
26143
Backgroun d Reflect or
26165
Maxi Spo t Reflecto r
40 cm 29 °
26149
Maxi Lit e Reflecto r
40 cm 43 °
26147
Snoot Gr id set 3
26427
Softlite White*
70 cm 82 °
26169
Softlite Silver*
70 cm 64 °
26167
Softlite Silver*
44 cm 55 °
26166
Diffuser Tissu
For 70 c m Softlite :
26235
For 44 c m Softlite : 26232
Softlite White*
44 cm 80 °
26168
Each Softlite reectors incudes a deector set
Snoot wi th Snoot
grid 15 °
26061
Mini Spo t Lite wit h filter holder,
lens & G obos set
26420
Zoom Spo t 18°-36° 26481
Fibre Opt ic Kit
Kit with two glass cables
26430
Kit with one glass cables 26431
Zoom Spo t Accessor y Set 26484
EL Octa 190 cm
26158
EL Quadr a 145 x 14 5
cm
26156
EL Recta 72 x 175
cm
26154
EL Strip 33 x 175 cm
26160
Deflecto rs
Set Gold -Silver 11 .2 cm
26303
Set Gold -Silver 16 .5 cm 26304
Translucent 14 cm 26305
Bayonet Reflector Support S et
22061
BX 250 R i 20460.1
BX 500 R i 20461.1
Multivoltage
D-Lite 2 20481
D-Lite 4 20482
Multivoltage
Polystan d 31045
EL Multi -Table Comple te 19228
Addition al tray 19226
Elinchrom Case
For 3 co mpacts
33209
For Digi tal RX & R anger RX 33215
Stand Se t A 30161
3 stands , 85-235 c m
& Carryi ng bag
Stand Se t A
30160
2 stands , 85-235 c m
& Carryi ng bag
Stand / Umbrella S et To Go
20564
2 stands , 85-235 c m
2 Umbrell as (silve r + trans lucent)
& Carryi ng bag
Elinchrom Softbag
For 2 co mpacts,
excepted Style RX 1200
33197
Varistar S et 105 26385
Varistar S et 85 26386
EL-Skypo rt Compute r Remote / Trigger Se t 19361
EL-Skypo rt Compute r Remote / Trigger Se t 19361
Page 15
14
This ELINCHROM product will be repaired free of charge by the vending agent if during a period of 24 months from date of purchase its working order is impaired through a manufacturing or material defect. The faulty product should be immediately sent to the authorized dealer or ELINCA agent.
This guarantee is not valid for equipment which has been misused, dismantled, modied or repaired by persons not belonging to the ELINCA distribution network. It does not cover ash tubes, lamps
and the normal ageing of capacitors. No responsibilities can be accepted for damage resulting from
unsatisfactoıy operation of the equipment, such as wasted lm or other expenses.
Please „register“ your Elinchrom product online, under
www.elinchrom.com > Downloads > Product Registration
i
Please return this registratioin card directly to Diese Registrierkarte bitte direkt zurücksenden an Veuillez retourner cette carte d’enregistrement directement à Vi preghiamo di far pervenire questa cartolina di iscrizione direttamente a Por favor envie esta carta de registro directamente
: : : : :
elinca sa
P.O. Box 458 Avenue de Longemalle 11 CH-1020 Renens Switzerland
Elinchrom model Elinchrom modèle Elinchrom modell Modello di Elinchrom Modelo de Elinchrom
: : : : :
Date of purchase
Datum des Kaufs
La date d’achat La data di acquisto La fecha de la compra
: : : : :
Dealer Händler Négociant Il distributore El comerciante
: : : : :
Your full name and address Ihr voller Name und redet an Votre nom complet et adresse Il suo nome pieno ed indirizza Su nombre y apellidos y dirige
: : : : :
In case you cannot register your Elinchrom unit via internet, please ll in the
Guarantee card and post it to Elinca.
GUARANTEE
Page 16
www.elinchrom.com
Loading...