Elinchrom SCANLITE 20998 User Manual

0 (0)
Elinchrom SCANLITE 20998 User Manual

is a registered trademark of ELINCHROM LTD, RENENS, SWITZERLAND

USER MANUAL

 

EN

 

DE

GEBRAUCHSANLEITUNG

 

IT

MANUEL D’UTILISATION

 

FR

 

ES

 

 

 

MANUALE D’USO

 

 

 

 

 

 

MANUAL DE INSTRUCCIONES

 

 

 

 

 

 

 

 

SCANLITE Halogen - 20998

 

 

 

 

 

 

Elinchrom SA Scanlite Halogen - Made in Switzerland - 22.09.2011 (73013)

User Manual Table of contents

EN

Introduction

3

 

 

 

Declaration of conformity

4

 

CE marking

4

 

Disposal and recycling

4

 

Characteristics

5

 

User Safety Information

5

 

Before You Start

6

 

Operating your SCANLITE

7

 

Fitting Accessories

7

 

SCANLITE Accessories

8

 

Technical Data

9

 

Maintenance

11

 

Caution

12

 

Warranty

51

2

User Manual

INTRODUCTION

Dear photographer

 

EN

Thank you for buying the ELINCHROM SCANLITE. All Elinchrom products are manufactured

 

using the most advanced technology. Carefully selected components are used to ensure

 

the highest quality and the equipment is submitted to many tests both during and after

 

manufacture. We trust that it will give you many years of reliable service.

 

 

 

Please read the instructions carefully, before use, for your safety and to obtain maximum benefit from many features.

Your Elinchrom-Team

Please read carefully the notes about this manual…

This manual may show images of products with accessories, which are not part of sets or single units. Elinchrom set and single unit configurations may change without advice and may differ in other countries.

Please find actual configurations at www.elinchrom.com

For further details, upgrades, news and the latest information about the Elinchrom System, please regularly visit the Elinchrom website. The latest user guides and technical specifications can be downloaded in the “Support” area.

Technical data, features and functions of Elinchrom flash units, accessories and the ELSkyport system may change without advice. The listed values can differ due to tolerances in components, or measuring instruments. Technical data, subject to change. No guarantee for misprints.

3

User Manual

DECLARATION OF CONFORMITY

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following

EN

two conditions:

 

1.

This device may not cause harmful interference, and

 

2.

This device must accept any interference received, including interference that may

cause undesired operation.

Product name:

SCANLITE Halogen

 

 

Trade name:

ELINCHROM

 

 

Model number(s):

20998

 

 

Name of responsible party:

Elinchrom S.A.

 

Av. De Longemalle 11

 

CH - 1020 Renens / Switzerland

 

 

Phone:

+41 21 637 26 77

 

 

Fax:

+41 21 637 26 81

 

 

E-Mail:

elinchrom@elinchrom.ch

ELINCHROM S.A. hereby declares that the equipment bearing the trade name and model number specified above was tested conforming to the applicable FCC rules, and that all the necessary steps have been taken and are in force to assure that the production units of the same equipment will continue to comply with the Commissions requirements.

CE MARKING

The shipped version of this device complies with the requirements of EMC directives

(EMC 2004/108/EC) «Electromagnetic compatibility» and (Low voltage 2006/95/EC) «Low voltage directive».

DISPOSAL AND RECYCLING

This device has been manufactured to the highest standards from materials, which can be recycled or disposed of in a manner that is not environmentally damaging. The device may be taken back after use to be recycled, provided that it is returned in a condition that is the result of normal use. Any components not reclaimable will be disposed of in an environmentally acceptable manner.

If you have any question on disposal, please contact your local office or your local ELINCHROM agent. Please visit our website and find your local ELINCHROM agents.

4

User Manual

CHARACTERISTICS

NEW: ZOOM function for the halogen lamp.

 

The ZOOM function is available from the left and right housing side.

EN

 

ZOOM angle 20° to 50°, with 21 cm Reflector // 26141.

For 300 - 650 W halogen lamps.

NEW: Protection glass dome included.

Halogen lamp on/off switch.

NEW: Centred umbrella fitting (7 mm).

Extra umbrella fitting for other umbrella shaft sizes.

NEW: Intelligent low noise fan cooling system. Electronically controlled fan spins slower or faster depending on the internal temperature of the head.

Large handle with rubber grip.

Small, robust and lightweight housing.

USER SAFETY INFORMATION

OUTDOORS, STUDIO & GENERAL USE

The halogen SCANLITE is a powerful light source. Please be aware of the danger, or inconvenience, that they may present to others such as example children.

Keep units out of reach of unauthorised persons whenever possible.

Do not use in restricted area (like hospitals, always ask permission before).

Do not use near flammable / explosive material. Keep minimum 1m distance to objects, or more if needed.

The unit and accessories may become very hot during and after use! To avoid injuries, handle with isolating cloth or wait until parts have cooled down.

Never direct light into the eyes of a subject without warning. Close use may affect eyesight.

Protect the SCANLITE when used in humid conditions, but ensure ventilation for cooling!

Acclimatizing: If the unit has been exposed to very cold conditions, sudden exposure to warm or humid air may cause condensation and malfunction.

Prevent direct sunlight, which might heat up the head.

Do not open the unit. In the event of damage, apparent failure, please contact the Elinchrom Service Centre.

5

User Manual

Halogen lamps may generate high pressure during operation. Explosions may occur with aged halogen lamps and incorrect fuse. For this reason the lamp is covered with a glass dome.

Damaged cables, glass domes and cases must be immediately replaced by customer EN service.

SAFETY NOTE FOR ACCESSORIES

Rotalux softboxes and umbrellas are limited to 300 W halogen lamps.

Metal reflectors can be used with 650 W halogen lamps, except small or narrow reflectors such as snoots and grids for Reflectors, which can be damaged or even burned by the excessive heat of the halogen lamp.

Not used SCANLITE’s should be switched off.

Ensure that the ventilation system of the SCANLITE works correctly.

No guarantee when materials are misused or damaged by excessive heat.

BEFORE YOU START

Ensure that the SCANLITE is switched OFF and the mains plug is removed, before mounting the halogen lamp.

Ensure that the halogen lamp voltage and the fuse correspond to the mains voltage 110 V or 230 V

Ensure that the SCANLITE is in a workable condition. Do not use the SCANLITE if the cable, fan or the housing show any kind of damage.

ATTENTION

Always switch the SCANLITE off and wait until the unit cooled down, before replacing halogen lamps or accessories! Note; for faster cooling of the halogen lamp and the SCANLITE, switch the light off, with the ON / OFF switch on the top of the head. The fan cooling is active, wait 5 minutes at least, before removing the mains plug.

The ambient temperature whilst the unit is in use: min. -20°C (-4°F) up to max. 35°C (95°F)

THIRD PARTY MANUFACTURERS

Use only original Elinchrom accessories and reflectors. The warranty does not cover damages forced by third party accessories and reflectors.

6

User Manual

OPERATING YOUR SCANLITE

SCANLITE ON/OFF SWITCH AND MAINS PLUG

EN

Before connecting the mains plug to the mains socket, ensure that the On/Off switch is in position Off: “0” must be visible on the switch (to prevent arcing mains plug contacts).

Then connect the mains cable to the mains socket => the fan spins and the cooling system is active.

Switch the halogen light on, press the On / Off switch to the On position.

After using the SCANLITE, switch the halogen light off, but do not remove the mains plug before the fan cooled down the temperature of the SCANLITE.

SCANLITE INTELLIGENT FAN COOLING AND OVERHEAT

PROTECTION

The fan speed is electronically controlled. Close to the on/off switch is a small LED, which lights up in case of over heating. The overheat protection shuts the Halogen lamp down at high internal temperature. After cooling down, the Halogen lamp switches on automatically and the red LED turns off.

FITTING ACCESSORIES

1.Always switch the unit off before attaching accessories.

2.Disconnect the mains cable.

3.Mount the SCANLITE Head to a tripod and lock the security screw.

4.Turn the locking ring of the reflector bayonet anticlockwise in OPEN position.

5.Insert an accessory and turn it clockwise until you hear it click into place.

6.Turn the locking ring clockwise to close the bayonet, indicated by the white mark on the bayonet ring.

7.Check if the Reflector is correctly fitted.

8.Reconnect the mains cable and switch the unit on.

7

User Manual

SCANLITE ACCESSORIES

HALOGEN LAMPS:

EN

300 W / 230 V Halogen GX 6.35 // 23022

 

 

300 W / 110 V Halogen GX 6.35 // 23030

 

650 W / 230 V Halogen GX 6.35 // 23005

 

650 W / 110 V Halogen GX 6.35 // 23027

GLASS DOMES

Glass Dome, transparent (standard configuration) // 24918

Glass Dome, frosted // 24919

8

User Manual

 

TECHNICAL DATA: SCANLITE

 

 

 

 

 

 

EN

SCANLITE

650 W

 

 

300 W

 

 

HALOGEN

 

 

 

 

 

 

 

 

 

Voltage

230 V

 

120 V

 

230 V

 

120 V

 

 

 

 

 

 

 

 

 

 

 

 

Aperture 2 m /

 

 

 

 

 

 

 

 

 

100 ISO / 1/30 s

11

 

8.0 710

 

8.0

 

5.6 710

 

 

 

 

 

 

 

Refl. HP (26137),

 

 

 

 

 

 

 

 

 

 

 

 

 

Zoom Pos. 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lux

12500

 

9500

 

8500

 

5500

 

 

 

 

 

 

 

 

 

 

 

 

Lumen

20000

 

20000

 

9600

 

8100

 

 

 

 

 

 

 

 

Multi-voltage

The SCANLITE Heads can be used with 110 V or 230 V. Only the

 

 

 

Halogen lamp and the fuse must apply to the correct voltages and

 

 

 

 

 

values!

 

 

 

 

 

 

 

 

 

 

 

 

 

Colour

 

 

 

3200 K

 

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Glass Dome

 

 

 

24918

 

 

 

 

TRANSPARENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Glass Dome

 

 

 

24919

 

 

 

 

FORSTED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modelling light

Standard configuration: 300 W / 230 V Halogen GX 6.35 // 23022.

 

 

230 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modelling light

Standard configuration: 300 W / 110 V Halogen GX 6.35 // 23030.

 

 

110 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls

Modelling lamp on/off and Zoom function.

 

 

 

 

 

 

Intelligent Fan

Fan speed is electronically temperature controlled. The overheat

 

 

Cooling

protection shuts down the Halogen lamp at high internal temperature,

 

 

after cooling down the Halogen lamp switches on automatically.

 

 

 

 

Included extras

Mains cable, Glass Dome transparent, Halogen Lamp 300 W / 650

 

 

 

W, Fuses, ZOOM-Function, Umbrella Support, Reflector Locking

 

 

 

 

 

Bayonet.

 

 

 

 

 

 

 

 

 

 

Tripod adaption

 

 

Standard 5/8”.

 

 

 

 

 

 

 

 

Dimensions, L x

245 x 155 x 205 (with protective cover).

 

 

 

W x H / mm

 

240 x 155 x 205 (with glass dome).

 

 

 

 

 

 

Weight, kg

1.2 kg (with protective cover, glass dome and Halogen lamp).

 

 

 

 

 

 

 

 

 

 

 

Order Code

 

 

 

20998

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

User Manual

REFLECTOR ZOOM TABLE

 

 

REFLECTOR Ø

EL-NO.

HOT SPOT

WIDE

EN

 

Reflector Maxi Spot 29° 40 cm

26149

 

 

 

 

 

 

Reflector HP 48° 26 cm

26137

22°

40°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot spot

 

Wide

 

 

 

 

 

 

SCANLITE HALOGEN LAMPS / FUSES

 

 

HALOGEN LAMP

 

 

 

FUSES

 

POWER

VOLTAGE

 

EL-NR

CURRENT

 

REACTION

EL-NR

 

 

(10 PCS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150W

230VAC

 

23032

2 A

 

FAST «F»

19032

 

 

 

 

 

 

 

 

200W

230VAC

 

23034

2 A

 

FAST «F»

19032

 

 

 

 

 

 

 

 

300W

230VAC

 

23022

2.5 A

 

FAST «F»

19033

 

 

 

 

 

 

 

 

500 W

230VAC

 

(*)

5 A

 

FAST «F»

19036

 

 

 

 

 

 

 

 

650 W

230VAC

 

23005

5 A

 

FAST «F»

19036

 

 

 

 

 

 

 

 

150W

120VAC

 

23031

2 A

 

FAST «F»

19032

 

 

 

 

 

 

 

 

200W

120VAC

 

(*)

2 A

 

FAST «F»

19032

 

 

 

 

 

 

 

 

300W

120VAC

 

23030

5 A

 

FAST «F»

19036

 

 

 

 

 

 

 

 

500 W

120VAC

 

(*)

10 A

 

FAST «F»

19038

 

 

 

 

 

 

 

 

650 W

120VAC

 

23027

10 A

 

FAST «F»

19038

 

 

 

 

 

 

 

 

(*) not available from Elinchrom

10

User Manual

MAINTENANCE

The SCANLITE Head requires only very little maintenance. To ensure secure operation

please check the following points regularly before connecting the Head to the mains:

EN

• Ensure that the Halogen lamp and the glass dome are correctly fitted.

• Do not use water to clean the Zoom Head from dust and dirt.

• Ventilation grids must be clean and free of any tape etc.

• When the SCANLITE Head is connected to the mains, check that the fan cooling is active.

CAUTION:

Under no circumstances open any part of the equipment. The SCANLITE Head is not user serviceable and there is dangerous high voltage. In the event of difficulties contact your Elinchrom Service partner.

REGULAR CHECK

National safety regulations may require frequent safety checks of the electrical equipment. The SCANLITE Head should be checked once a year. This check not only guarantees safety, it also protects the value of the unit.

RETURN TO CUSTOMER SERVICE

To achieve maximum protection of the unit when sending it in for service, the original packaging should be kept.

SALES / SERVICE / RENTAL

For service and sales, please contact your local Elinchrom Distributor. For more information, contact and support, please visit www.elinchrom.com / Distributors

11

Gebrauchsanleitung

INHALT

 

Einleitung

13

DE

Konformitätserklärung

14

 

CE / Recycling

14

 

Charakteristik

15

 

Sicherheitshinweise

15

 

Vor dem Start

16

 

Fremdhersteller

16

 

Reflektoren Adaptieren

17

 

SCANLITE Zubehör

17

 

Technische Daten

18

 

Wartung

20

 

Bitte Beachten

20

 

Garantie

51

12

Gebrauchsanleitung

EINLEITUNG

 

Lieber Photograph und Fotoenthusiast

 

 

Herzlichen Dank, dass Sie sich für das Elinchrom SCANLITE entschieden haben.

DE

 

Die hervorragende Lichtqualität und die technische Leistung der SCANLITE

 

Halogenlampenköpfe beruhen auf langjährigen Erfahrungen auf dem Gebiet der Herstellung

 

von Beleuchtungsanlagen. Elinchrom Lichtprodukte entsprechen den gültigen elektrischen

 

Normen unter Verwendung hochwertiger ausgesuchter Materialien, die Ihnen langfristige

 

Produktivität und Zuverlässigkeit gewähren sollen.

 

Bitte lesen Sie die Anleitung, die Informationen über die sichere Verwendung und die

 

Funktionen des Gerätes beinhaltet.

 

Bitte sorgfältig lesen...

 

Diese Anleitung enthält Fotos von Produkten die ständig weiterentwickelt werden. Von

 

daher sind Änderungen in Ausstattung, Funktionen und Design jederzeit möglich. Zudem

 

werden Lampenköpfe und Blitzgeräte mit Reflektoren oder Stativen gezeigt, die nicht,

 

oder nur in Einzelfällen zur Grundausstattung eines Gerätes oder eines Sets dazugehören.

 

Aktualisierte Informationen über Geräte, Zubehör und EL-Skyport sind von der Elinchrom

 

Webseite zu entnehmen www.elinchrom.com.

 

Toleranzen der technischen Daten für Bauelemente und Messwerte entsprechen den IEC -

 

und EC Normen. Technische Änderungen vorbehalten. Die Werte können durch Messgeräte

 

und Toleranzen in den Bauelementen schwanken und sind als Richtwerte zu verstehen und

 

nicht im rechtlichen Sinne als zugesicherte Eigenschaften. Keine Haftung für Druckfehler.

 

Ihr Elinchrom Team

 

13

Gebrauchsanleitung

KONFORMITÄTSERKLÄRUNG

Dieses Gerät entspricht Paragraph 15 der FCC Normen, die folgende Punkte beinhalten:

DE

1. Dieses Gerät verursacht keine Interferenzen die nicht den Normen entsprechen.

2. Dieses Gerät akzeptiert jegliche Interferenzen, auch die, die eventuell Störungen verursachen können.

Produktname:

SCANLITE Halogen

 

 

Marktname:

ELINCHROM

 

 

Modellversion(n):

20998

 

 

Verantwortliche Firma:

Elinchrom S.A.

 

Av. De Longemalle 11

 

CH - 1020 Renens / Switzerland

 

 

Telefon :

+41 21 637 26 77

 

 

Fax:

+41 21 637 26 81

 

 

E-Mail:

elinchrom@elinchrom.ch

 

 

ELINCHROM S.A. erklärt hiermit, das die Geräte mit den genannten Modellen nach den einschlägigen EWG, DIN, IEC und FCC Normen geprüft und getestet wurden, sowie allen Vorschriften entsprechen. Alle notwendigen Prüfungen werden durchgeführt um die Einhaltung und Sicherheit auch während der Serienproduktion zu garantieren.

CE

Dieses Studiogerät entspricht den Anforderungen der EMV Richtlinie (EMV 2004/108/EC) Elektromagnetische Verträglichkeit” und (2006/95/EC) “Niederspannungsrichtlinie”.

ENTSORGUNG UND RECYCLING

Dieses Gerät wurde weitestgehend aus Materialien hergestellt, die umweltschonend entsorgt und einem fachgerechten Recycling zugeführt werden können. Nach seinem Gebrauch wird das Gerät zurückgenommen, um es einer Wiederverwendung bzw. wertstofflichen Verwertung zuzuführen, soweit es in einem Zustand zurückgegeben wird, der dem bestimmungsgemäßen Gebrauch entspricht. Nicht verwertbare Geräteteile werden sachgemäß entsorgt.

14

Gebrauchsanleitung

CHARAKTERISTIK

• NEU: ZOOM Funktion für das Halogen Einstelllicht.

 

 

• Für die ZOOM Einstellung befinden sich an beiden Gehäuseseiten Einstellknöpfe.

DE

 

• ZOOM Winkel von 20° bis 50°, mit Standard Reflektor 21 cm // 26141

 

• Maximal 300 W – 650 W Halogen Einstelllicht.

 

• NEU: Schutzglasglocken in transparent (Standard) und matt verfügbar.

 

 

• Beleuchteter Einstelllichtschalter ein/aus.

 

• Zentrierte Schirmhalterung für EL-Schirmstöcke bis 7 mm Durchmesser.

 

• Extra Schirmhalterung am Neigekopf, für größere Schirmstock Durchmesser.

 

• NEU: Intelligentes geräuscharmes Kühlgebläse. Die Elektronik kontrolliert die

 

Kühlgebläse Geschwindigkeit je nach der internen Temperatur.

 

• Großer ergonomischer Handgriff mit Sicherungshalterung.

 

• Leichtes hochwertiges und strapazierbares Gehäuse.

 

SICHERHEITSHINWEISE

Lassen Sie niemals Kinder unbeaufsichtigt mit Beleuchtungsanlagen alleine!! Dieses Gerät nicht in verbotenen oder explosiven Bereichen verwenden.

Beleuchtungsanlagen nur mit Genehmigung der Zuständigen, in Krankenhäusern, Museen, Fabriken, etc. verwenden.

Halten Sie brennbare / explosive Materialien fern von Beleuchtungsanlagen.

Die Lampenköpfe sind nicht gegen Spritzwasser, Regen oder Schmutz geschützt. Unter solchen Bedingungen müssen die Lampenköpfe entsprechend geschützt werden. Die Ventilation darf nicht beeinträchtigt werden, um Überhitzung oder gar Brände zu vermeiden.

Schauen Sie niemals direkt in die Halogen Lichtquelle!

Berühren Sie niemals das Einstelllicht und das Zubehör, diese werden bei Betrieb sehr heiß.

Transport nur in Elinchrom Originaltaschen, Koffer, Kartons um den Lampenköpfe und das Zubehör bestmöglich vor Schäden zu schützen.

Verwenden Sie immer den Schutzreflektor um die Halogenlampe zu schützen.

Vermeiden Sie direkte Sonneneinstrahlung, damit sich das Gerät nicht unnötig aufheizt.

Vermeiden Sie Kondensationsprobleme durch starke Temperaturschwankungen.

Verwenden Sie nur das original Elinchrom Zubehör.

15

 

Gebrauchsanleitung

 

 

 

 

 

 

• Halogenlampen generieren Überdruck. Alte, schadhafte und falsch abgesicherte

 

Halogenlampen können explodieren.

 

• Rotalux und Reflexschirme bitte nur bis maximal 300 W belasten.

 

DE

• Metallreflektoren können bis 650 W belastet werden. Unter Ausnahme der

 

Tubusreflektoren und Reflektoren die mit Waben benutzt werden. Diese sollten

 

maximal bis 300 W belastet werden und auch nur für begrenzte Zeit, um einen

 

Hitzestau bzw. Verbrennungen des Zubehörs zu vermeiden.

 

• Immer darauf achten das die Ventilation / Kühlgebläse funktioniert!

 

 

ACHTUNG STROMSCHLAGGEFAHR!!

 

Öffnen Sie niemals das Gehäuse um Reparaturen oder Modifikationen durchzuführen. Nur

 

der Elinchrom Service ist autorisiert, Arbeiten im und am Lampenkopf durchzuführen.

VOR DEM START

Das SCANLITE ausschalten und Netzkabel ziehen bevor Halogenlampen oder Zubehör gewechselt wird.

Vergewissern Sie sich das, dass SCANLITE in einwandfreiem Zustand ist.

Beachten Sie die Netzspannung 110V oder 230V und verwenden Sie die dementsprechenden Halogenlampen.

Auf korrekte Absicherung der Halogenlampe achten.

Alle Verbindungen prüfen, erst dann das SCANLITE einschalten.

VORSICHT

Immer erst das SCANLITE abschalten und abkühlen lassen bevor Zubehör und Halogenlampen gewechselt werden.

Bitte die Umgebungstemperaturen beachten: min. -20°C (-4°F) bis zu max. 35°C (95°F)

FREMDHERSTELLER

Nur das original Elinchrom Zubehörprogramm verwenden. Die Garantie entfällt bei

Beschädigungen die durch Fremdfabrikate verursacht wurden.

SCANLITE EIN/AUS SCHALTER

Das Halogen Einstelllicht kann direkt am Lampenkopf einund ausgeschaltet werden falls erforderlich.

16

Gebrauchsanleitung

INTELLIGENTES KÜHLSYSTEM MIT ÜBERHITZUNGSANZEIGE

Die Ventilator Drehgeschwindigkeit wird elektronisch je nach der internen Temperatur geregelt. Falls die interne Temperatur zu hoch ist, schaltet sich das Einstelllicht ab und ein

rotes Warnlicht leuchtet neben dem ein/aus Schalter während der Abkühlphase auf. Erreicht DE das SCANLITE wieder die Betriebstemperatur schaltet sich das Einstelllicht ein und das

Warnlicht ab.

REFLEKTOREN ADAPTIEREN

1.SCANLITE abschalten, bevor Zubehör gewechselt oder angebracht wird.

2.Das Netzkabel zur Sicherheit von der Steckdose trennen.

3.Das SCANLITE auf einem geeigneten Stativ befestigen.

4.Den Verschlussring des Bajonetts gegen den Uhrzeigersinn in Richtung „Öffnen“ drehen.

5.Einen Reflektor einsetzen und im Uhrzeigersinn drehen bis das Einrastgeräusch hörbar ist.

6.Den Verschlussring im Uhrzeigersinn drehen um das Bajonett zu verschließen. Bitte die weiße Markierung auf dem Bajonettring beachten.

7.Bitte prüfen das der Reflektor die Softbox korrekt befestigt wurde.

8.Das Netzkabel verbinden und das SCANLITE einschalten.

SCANLITE ZUBEHÖR

HALOGENLAMPEN:

Maximal 300 W / 230 V Halogen GX 6.35 // 23022

Maximal 300 W / 110 V Halogen GX 6.35 // 23030

Maximal 650 W / 230 V Halogen GX 6.35 // 23005

Maximal 650 W / 110 V Halogen GX 6.35 // 23027

SCHUTZGLASGLOCKEN

Schutzglasglocke, transparent (Standard Konfiguration) // 24918

Schutzglasglocke, matt - satiniert // 24919

17

Loading...
+ 39 hidden pages