Control Panel 6
Switch and Fuse 7
Modelling Light 8
Digital power display, Photo-cell 9
Synchronisation, Wireless Remote control and ash triggering 10
Acoustic signal 10
Troubleshooting 7, 10
Flash tube replacement 11
Technical Data 12
Elinchrom Accessories 13
Guarantee 14
P.S: Technical data subject to change.
The listed values are guide values which may vary due to tolerances in components used.
Introduction
The Elinchrom Style RX is manufactured by Elinca S.A. CH -1020 Renens/Switzerland
Dear Photographer,
Thank you for buying your Style RX compact ash unit. All Elinchrom products are manufactured using the most advanced technology. Carefully selected components are used to ensure the highest quality and the equipment is submitted to many controls both during and after manufacture. We trust that it will give you many years of reliable service.
All Style RX ash units are manufactured for the studio and location use of professional photographers. Only by observance of the information given, can you secure your warranty, prevent possible damage and increase the life of this equipment.
Style 300RX - 600RX - 1200RX
The quality of light and exceptional performance is the result of long research, application of demanding principles, the long experience of ELINCHROM in lighting products for the studio and the utilization of the latest technology in this area.
Totally integrated to the range of the ELINCHROM ashes, the Style 300RX - 600RX -
1200RX units maintain the traditional look and function that is ELINCHROM.
The control provides continuously variable adjustment of the modelling lamp and the ash
power with precision over 6 f-stop, from full power 1/1 to 1/32 th.
FCC Class B Compliance Statement
Note:
This equipement has been tested and found to comply with the limits for a class B digital device, pursuant to Part
15 of the FCC Rules and meets all requirements of the Canadian Interference-Causing Equipement Regulations.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipement generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipement
does not cause harmful interferences to radio or television reception, which can be determined by turning the
equipement off and on, the user is encouraged to correct the interferences by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipement and receiver.
- Connect the equipement into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ELINCA S.A. is not responsible for any radio or television interference caused by unauthorised modications of
this equipement or the substitution or attachment of connecting cables and equipement other than those specied
by ELINCA S.A. The correction of interference caused by such unauthorised modication, substitution or
attachment will be the responsibility of the user.
2
Declaration of conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Product name: Professional Studio Flash unit
Trade name: ELINCHROM
Model number(s): Style RX 300/600/1200
Name of responsible party: Elinca S.A
Av. De Longemalle 11 1020 Renens / Switzerland
Phone : +41 21 637 2677
Fax: +41 21 637 2681
We, ELINCA S.A., hereby declare that the equipement bearing the trade name and model number
specied above was tested conforming to the applicable FCC rules, and that all the necessary steps
have been taken and are in force to assure that the production units of the same equipement will continue to comply with the Comissions requirements.
Disposal and recycling
This device has been manufactured to the highest possible degree from materials which can be recycled or disposed of in a manner that is not enviromentally damaging. The device may be taken back after use to be recycled, provided that is returned in a condition that is the result of normal use. Any components not reclaimed will be disposed of in a environmentally acceptable manner.
If you have any question on disposal, please contact your local ofce or your local ELINCHROM
agent (check our website for a list of all ELINCHROM agents world wide).
CE marking
The shipped version of this device complies with the requirements of ECC directives 89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage directive».
Notational Conventions
The meaning of the symbols and fonts used in this manual are as follows:
Pay particular attention to text marked with this symbol. Failure to observe this warning endangers your life, destroys the device, or may damage other equipement
!
Supplementary information, remarks, and tips follow this symbol. Text which follows this symbol describes activities that must be performed in the order shown.
i
«Quotation marks» indicate names of chapters or terms
Safety notice
According to safety regulations, we draw your attention to the fact that these electronic ash units
are not designed for use outdoors, in damp or dusty conditions and should not be used after being exposed to sudden temperature changes causing condensation. They must always be connected to an earthed (grounded) mains supply. On no account should any object be inserted into the ventilation. The units may retain an internal charge for a considerable time even though disconnected from the power supply. Do not use in restricted area (like hospitals) and in explosive environnements.
Flash Tubes and Modelling lamps
• Flashtubes and modelling lamps in use are very hot!
• Never touch a ash tube or lamp before the unit cooled down and is disconnected from the mains.
• Do not re ashes from short distance (less than 1m) directed to a person and avoid looking directly into the ashlight!
• Keep distance to ammable materials.
• Keep generally distance to operating units.
Transport
• Transport the ash unit with care and only in its original packaging or another corresponding packaging t to protect it against knocks and jolts.
• Transport only in complete discharged conditions. Wait a minimum 30 minutes after removing
from mains supply before packaging and transportation.
• Never drop the ash unit (danger of breaking ash tubes).
Power cable
To guarantee safe operation, use the cable supplied.
• The cable has to be HAR-certied or VDE-certied. the mark HAR or VDE will appear on the outer
sheat.
• The cable set must be selected according to the rated current for your ash unit.
• Do not use a spider box to connect one or more ash units.
!
FLASH SYSTEMS STORE ELECTRICAL ENERGY IN CAPACITORS BY
APPLYING HIGH VOLTAGE.
FOR YOUR SAFETY, NEVER OPEN OR DISASSEMBLE YOUR FLASHES.
ONLY AN AUTHORISED SERVICE ENGINEER SHOULD OPEN OR ATTEMPT
TO REPAIR THE UNITS.
INTERNAL DEFECT CHARGE CAPACITORS MAY EXPLODE WHILST THE UNIT IS IN
USE, NEVER SWITCH ON A PROPER WORKING FLASH UNIT.
Before you start !
The Style RX unit voltage must correspond with your mains voltage. Style RX are delivered in 120V or 230V versions. Before connecting for the rst time, check to make sure that
your Modelling lamp coincides with the voltage line. They must always be connected to an earthed ( grounded) mains supply.
All Style RX units have a bayonet mount and locking ring reector tting, for xing all Elinchrom and
Prolinca accessories.
Mount the unit securely to a suitable stand or support.
Remove the black protective cover (note: rst turn the locking ring A as shown, then rotate the
black cap cover B in the same direction).
Fitting a reector or accessory is the reverse of this action.
handle
A
locking
B
protective cover
Operating instructions
1.Check that the modelling lamp voltage is correct.
2.Check that the mains switch (3) is in the OFF ("O" position).
3.Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET
4.Using the mains SWITCH (3) and switch the unit ON ("I" position).
5.Connect the synchro cord on the socket (6).
6.Select the power with the touch pad (11 - 12)
12
11
1
C
tilthead with locking
6
3
5
Control Panel
7
12
11
4
16
13
14 15
2
1
18
9 10
8 6
5
22
3
20
1921
17
Overview of controls
1.Mains inlet socket
2.Mains fuse (slow blow)
3.Mains Illuminated on/off switch
4.Modelling fuse (fast blow)
5.Open-ash
6.Synchro-sockets, Amphenol + jack 3.5 mm
7.Digital power display and charge/discharge indicator
8. Acoustic recharging signal (Beep)
9. Slave cell switch on/off
10. Photocell receptor
11. Power adjustment in 1/10 f-stops, with ADF
12. + Power adjustment in 1/10 f-stops 1 3. Modelling lamp switch (on/off free or prop)
14.+ Modelling power control
15. - Modelling power control
16. Tilt head clamp
17. Knurled clamp screw
18. Handle
19. Stand 5/8-inch socket
20. Umbrella tube (only for EL umbrellas, diameter 7 mm)
21.Supplementary locking for others umbrellas
22. Socket for remote or PC - Multi Link
Mains Supply
With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug
of the original ELINCHROM mains cord into the mains socket (1).
Mains Switch
The switch should light up when the compact is switched on ("I" position). (Switch off before removing the mains cord).
Troubleshooting
If the on/off switch (3) is ON ("I" position) but not illuminated, switch off the unit and check the mains fuse (2). If failed replace with the correct fuse and switch ON the unit. This unit is protected by a thermal circuit breaker to avoid overheating.
Should this occur, the unit turns off automatically and cannot be red. After a break for cooling, the ash will be ready again for operation.
See page 10 / Troubleshooting. This equipment is not user serviceable and contains high voltages which are dangerous. In the event of failure, please return the unit to an authorized Elinchrom service station.
Mains Fuse
Standard type 5 x 20 mm, (use only tempered fuse)
• Style 300RX : 5 AT
• Style 600RX : 6,3 AT
• Style 1200RX : 8 AT
Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and turn the fuse
holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately upon reconnection, return
the unit to an ELINCHROM service centre for a check-up.
(N.B. Please don't forget to check the correct rating of the fuse !).
Fuse for modelling light
Fast type 5 x 20mm, 2.5 AF Switch off the unit and replace the blown fuse with a new one of the correct rating. The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore
the ash tube.
Modelling fuse 4 AF
4
3
Mains switch
Mains fuse 8 AT
(Only tempered)
Mains socket
1
2
Modelling Light
The touch pad (14) controls the modelling lamp on/off and the proportional light. Select the power with the touch pad (15). The modelling light output (100%) is achieved when the power value is set to maximum. Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the
light output is proportional to the selected ash power. For all types of Style RX compact ash units, use maximum 250 - 300W modelling lamps.
230V Modelling lamps and fuses
Unit Modelling lamp Code Socket Fuse Code
Style 300RX 250W halostar 23018 E27 2,5AF 19033
Style 600RX 250W halostar 23018 E27 2,5AF 19033
Style 1200RX 300W halogen 23022 GX 6,35 2,5AF 19033
120V Modelling lamps and fuses
Unit Modelling lamp Code Socket Fuse Code
Style 300RX 150W halogen 23037 BA15D 4 AF 19035
Style 600RX 150W halogen 23037 BA15D 4 AF 19035
Style 1200RX 250W halogen 23038 BA15D 4 AF 19035
120V «Canada Version» Modelling lamps and fuses
Unit Modelling lamp Code Socket Fuse Code
Style 300RX 150W halogen 23012 E27 4 AF 19035
Style 600RX 150W halogen 23012 E27 4 AF 19035
Style 1200RX 150W halogen 23012 E27 4 AF 19035
230V Modelling lamp options:
23022
23101
23018
120V Modelling lamp:
23037
This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp
300W, GX 6.35 (code 23022) for Style 300 and 600 RX units.
If the modelling lamp does not light up.
1. The lament is broken after long use (replace lamp and fuse)
2. The lament is broken after shock (replace lamp and fuse)
3. An internal component failure (return the unit to customer service)
8
Digital Power Display
The actual ash power is displayed in a f-stop compatible format.
The power range is 6 f-stops. The digital display, provides continuous power indication of the
ash and modelling lamp. The controls cover a continuous output range from full power 1/1 to
1/32th in 1/10th, f-stop intervals.
During charging or discharging, the display "ashes". In case of overheating or malfunction,
the display shows "ER" for error.
Note:
This "Style 300RX, 600RX and 1200RX" units have an integrated discharge system, protected by a
thermic switch.
To avoid overheating, lower power settings, more than 2f-stop, can be discharged manually by releasing
the ash with the «Test» touch button.
Photocell
The photocell is actived when the green LED (on the touch pad 9) is illuminated.
When switched ON, the unit can be remotely triggered by another ash unit !
The Style BX photocell is specially designed to work under ambiant light conditions in your studio. Direct light or other strong light sources may reduce the sensitivity of the cell.
In difcult situations e.g. blinding, sunlight or obstacles, the additional cell with 5 m cord
(extensions available) solves most problems.
Additional cell : code 11081 Extension cord 10 m : code 11080
Power display
Modellling light controls
Cell (9)
Photocell receptor (10)
Test and ready (5)
Wireless Remote Control and Flash Triggering
All RX units, Style RX, Digital RX, Ranger RX are equipped with the Remote Plug, to connect the EL-Skyport Trigger and Remote System. With the EL- Skyport RX Trigger Set 19362, the RX units can be triggered wireless, up to approximately 100 m distance. Apart from triggering,
the Transmitter offers modelling lamp on /off settings and ash power control in 1/10th steps.
By using the EL- Skyport Computer Remote / Trigger Set 19361, all RX functions can be controlled and operated with a MAC° or Windows° computer.
19361
19362
For details of the most advanced wireless system please visit www.elinchrom.com > Products > RX Multi Remote > EL-Skyport.
Sychronisation socket
The standard socket 3.5 mm mini-jack (6). N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets.
ELINCHROM uses the low voltage (5 V) for security reasons.
Open ash "test"
Having pressed the touch pad to release a ash, the green «READY» light will
appear again once the unit is recharged. If the green light does not appear the charge system could be defective. Please contact and send to an authorized Elinchrom service.
Audible recharge signal
Select the function with the touch pad (8), the green indicator appears. Once recycled an acoustic signal indicates that the compact unit is ready.
Troubleshooting
1. The mains switch (3) is ON ("I" position), but not light up:
• Switch OFF the unit and change the mains fuse (2)
• Use only time-lag fuse (16 AT), corresponding to the Style RX model
2. The switch (3) is lit, the open ash ready is lighting up but does not function.
• The ashtube in the ashhead may be faulty (see page 11)
• If replacing the ashtube does not solve the problem, the cause could be a
component failure => please return the unit to an authorised Elinchrom service.
3. The ON/OFF switch (3) is lit but the open ash signal (6) is not lit
• Temporary break for overheating, caused by fast ash sequences or ventilation
slots obturated
• Fan cooling defective => the unit turns off automatically and cannot be red any more. After a break for cooling, the ash is ready again for operation.
• If after several minutes of break for cooling the ready signal (6) is not lit, the cause
could be a component failure. However, high voltage may remain on the capacitor circuits. => DO NOT ATTEMPT TO REPAIR THE UNIT. In this case please send the unit to an authorised Elincrom station.
Sync
Test and Ready
6
Beep
5
8
10
Flash tube replacement
If the unit does not ash but the ON/OFF switch indicates that there is power, it could be that the ashtube needs replacing.
Note:
Flash tubes (Swiss quality) have a long life with average use, but multiashing in long sequences can cause
overheating of the electrodes leading to premature ageing, or perhaps the ash tube is broken or cracked.
To replace the Flash tube:
remove the tube
1. Switch off the mains switch
2. Remove the mains cable
3. Take the unit from its stand or lay it horizontally on a rigid surface. It will need to
be held rmly whilst removing and replacing the tube.
4. Allow the ash tube and modelling lamp to cool
for several minutes. They may be very hot.
5. Carefully remove and store the modelling lamp.
Stand
Plug- in ashtube
(made in Switzerland) (code 24029)
6. Put on the protective glove delivered with
your ash tube and remove: A - rst the security spring trigger B - the ash tube, by rmly pulling it away from the unit.
If the tube is broken, avoid cutting yourself and the
contact with
security spring
glove. If the only part to grip is the electrode (e.g. a totally smashed tube), withdraw using insulated pliers or pincers.
There is a full discharge security circuit tted, but
if the unit has had a heavy fall, internal damage disconnecting a circuit could possibly happen.
correctly aligned
7. Take the new ash tube, code 24029 for Style 300BX-600RX, and
code 24068 for Style 1200RX.
A glove or "plastic protection" MUST BE USED - contact with your ngers on the glass,
will cause dark markings on the tube when it is used.
8. Check that the tube is correctly aligned (central) and that the trigger contact is gripping
the tube, rex the security spring.
9. Re-connect and test the unit as usual.
11
Features
• Locking bayonet ring for accessory and reector tting
• Tilthead whit 5/8" - inch stand socket
• Thermal safety
• User replaceable ash tube UV coated (5650°K)
• Halogen modelling lamp 250W, with E27 tting, and 300W/GX6.35for Style 1200RX (230V Version)
• Silent fan cooling
• Controls for: modelling on/off, cell on/off, acoustic signal on/off.
• Flash and modelling power control.
• «X» synchro jack socket 3,5 mm.
• Socket for Plug-In remote control.
• Auto dumping function. Automatic discharge of ash power
• Central umbrella tube plus external tting
• Acoustic recharging signal
• Mains cable
• Synchro cord of 5m (jack 3.5mm plug)
• Protective cover
• Total compatibility with all Elinchrom accessories
• Very fast recycling time
• Very short ash duration
Technical data 300RX 600RX 1200RX
Flash power J(Ws) 300 600 1200
Power supply 230V Version V all units 215-240
120V Version V all units 110-120
F-stop, 1m, 100 ISO, with reector 48° GN 64,1 90,1 128,1
Control range J(Ws) 9-300 18-600 36-1200
Recycling time 230V Version s 0,2-0,6 0,25-0,8 0,35-1,5
120V Version s 0,25-1 0,3-1,6 0,35-2,8
Flash duration (t 0,5) 1/1 s 1/2850 1/2050 1/1450
(t 0,5) 1/32 s 1/1350 1/850 1/480
Modelling lamp 230V Version W 250*/E27 250*/E27 300 GX 6,35
120V Version W 150/BA15D 150/BA15D 250/BA15D
120V «Canada Version» W 150/E27 150/E27 150/E27
Voltage across sync cable V 5 5 5
Connected load A/VA (W) 5/1150 6,3/1500 8/1840
Radio interference suppressiv CE-IEC 491 EN 60 555 - EN 61 000 - 4 - 2/3/4/5
Dimension length x diam. cm 21x14 21x14 30x14
Weight kg 2,15 2,45 3,45
* Optional alternative 300W/GX6.35
Tolerances and specications conforming to IEC and CE standards.
Technical data subject to change without notice.
12
Elinchrom Accessories
code
Reectors Wide angle ø 16 cm /90° 26143
Compact ø 18 cm /60° 26144
Standard ø 21 cm /50° 26141
Mini Soft ø 44 cm silver 26166
Mini Soft ø 44 cm white 26168
Snoot & Grid 26061
Grid set for snoot 26427
Grids Grid set for reector 18 cm 26135
Grid set for 21 cm 26051
Filters Set of 10 color/mixed lters for 21 cm x 21 cm 26243
Polarizing lter 21 cm 26244
Lightbanks ROTALUX Square 70 x70 cm 26178
Square 100 x100 cm 26179
Strip 95 x 35 cm 26180
Rectangular 130 x 50 cm 26181
Octagonal 100 cm 26183
Octagonal 135 cm 26184
Umbrellas White diam. 85 cm 26372
Silver diam. 85 cm 26350
Translucent diam. 85 cm 26371
Spots Zoom Spot 18° - 36° 26481
Mini Spot 26420
Stands Stand 85-235cm 30101
Stand Master 109-385 cm 30149B
Bags Carrying bag for 2 Style RX 600 33197
Carrying bag for 2 stands + 2 umbrellas 33220
Case Carrying case for 3 mono compatcs 33209
Trigger accessories IR ash remote 40203
EL-Skyport computer remote Set 19361
EL-Skyport RX Trigger Set 19362
Synchro cords Synchro cable 5 m length
Modelling lamps (90/140V) Quartz Halogen, Socket E27 - 150W 23019
Modelling lamps (190/260V) Kypton/photo, Socket E27 - 100W 23002
camera to ash units (jack 3.5 mm)
Quartz Halogen, GX 6,35 - 150W 23031
Quartz Halogen, GX 6.35 - 200W 23033
Quartz Halogen, Socket E27 - 150W 23035
Quartz Halogen, GX 6.35 - 200W 23034
Halostar 250W - E27 23018
Halogen 300W - GX 6.35 23022
11084
13
Guarantee
This ELINCHROM product will be repaired free of charge by the vending agent if during a period of 24 months from date of purchase its working order is impaired through a manufacturing or material defect. The faulty product should be immediately sent to the authorized dealer or ELINCA agent.
This guarantee is not valid for equipment which has been misused, dismantled, modied or repaired by persons not belonging to the ELINCA distribution network. It does not cover ash tubes, lamps
and the normal ageing of capacitors. No responsibilities can be accepted for damage resulting from
unsatisfactoıy operation of the equipment, such as wasted lm or other expenses.
i
Please „register“ your Elinchrom product online, under
www.elinchrom.com > Downloads > Product Registration
In case you cannot register your Elinchrom unit via internet, please ll in the
Guarantee card and post it to Elinca.
Please return this registratioin card directly to Diese Registrierkarte bitte direkt zurücksenden an
Veuillez retourner cette carte d’enregistrement directement à Vi preghiamo di far pervenire questa cartolina di iscrizione direttamente a
Por favor envie esta carta de registro directamente
Elinchrom model Elinchrom modèle Elinchrom modell Modello di Elinchrom Modelo de Elinchrom
Date of purchase
Datum des Kaufs La date d’achat
La data di acquisto La fecha de la compra
: : : : :
: : : : :
Dealer Händler Négociant Il distributore El comerciante
:
elinca sa
:
P.O. Box 458
:
Avenue de Longemalle 11
:
CH-1020 Renens
:
Switzerland
: : : : :
Your full name and address Ihr voller Name und redet an
Votre nom complet et adresse
Il suo nome pieno ed indirizza Su nombre y apellidos y dirige
: : : : :
14
www.elinchrom.com
Loading...