Elinca S.A Style RX 01.01.2007 ENG (73253) Printed in Switzerland
English
Table of contents
Introduction2
Declaration of conformity, disposal and recycling, CE marking3
Safety notice and precaution4
Operating instructions5
Control Panel6
Switch and Fuse7
Modelling Light8
Digital power display, Photo-cell9
Synchronisation, Wireless Remote control and ash triggering10
Acoustic signal10
Troubleshooting7, 10
Flash tube replacement 11
Technical Data12
Elinchrom Accessories13
Guarantee14
P.S: Technical data subject to change.
The listed values are guide values which may vary due to tolerances in components used.
1
Introduction
The Elinchrom Style RX is manufactured by Elinca S.A. CH -1020 Renens/Switzerland
Dear Photographer,
Thank you for buying your Style RX compact ash unit.
All Elinchrom products are manufactured using the most advanced technology. Carefully selected
components are used to ensure the highest quality and the equipment is submitted to many controls
both during and after manufacture. We trust that it will give you many years of reliable service.
All Style RX ash units are manufactured for the studio and location use of professional
photographers. Only by observance of the information given, can you secure your warranty, prevent
possible damage and increase the life of this equipment.
Style 300RX - 600RX - 1200RX
The quality of light and exceptional performance is the result of long research, application of
demanding principles, the long experience of ELINCHROM in lighting products for the studio
and the utilization of the latest technology in this area.
Totally integrated to the range of the ELINCHROM ashes, the Style 300RX - 600RX -
1200RX units maintain the traditional look and function that is ELINCHROM.
The control provides continuously variable adjustment of the modelling lamp and the ash
power with precision over 6 f-stop, from full power 1/1 to 1/32 th.
FCC Class B Compliance Statement
Note:
This equipement has been tested and found to comply with the limits for a class B digital device, pursuant to Part
15 of the FCC Rules and meets all requirements of the Canadian Interference-Causing Equipement Regulations.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipement generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipement
does not cause harmful interferences to radio or television reception, which can be determined by turning the
equipement off and on, the user is encouraged to correct the interferences by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipement and receiver.
- Connect the equipement into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ELINCA S.A. is not responsible for any radio or television interference caused by unauthorised modications of
this equipement or the substitution or attachment of connecting cables and equipement other than those specied
by ELINCA S.A. The correction of interference caused by such unauthorised modication, substitution or
attachment will be the responsibility of the user.
2
Declaration of conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
Product name:Professional Studio Flash unit
Trade name:ELINCHROM
Model number(s):Style RX 300/600/1200
Name of responsible party:Elinca S.A
Av. De Longemalle 11
1020 Renens / Switzerland
Phone :+41 21 637 2677
Fax:+41 21 637 2681
We, ELINCA S.A., hereby declare that the equipement bearing the trade name and model number
specied above was tested conforming to the applicable FCC rules, and that all the necessary steps
have been taken and are in force to assure that the production units of the same equipement will
continue to comply with the Comissions requirements.
Disposal and recycling
This device has been manufactured to the highest possible degree from materials which can be recycled or disposed of in a manner that is not enviromentally
damaging. The device may be taken back after use to be recycled, provided that is
returned in a condition that is the result of normal use. Any components not reclaimed
will be disposed of in a environmentally acceptable manner.
If you have any question on disposal, please contact your local ofce or your local ELINCHROM
agent (check our website for a list of all ELINCHROM agents world wide).
CE marking
The shipped version of this device complies with the requirements of ECC directives
89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage directive».
Notational Conventions
The meaning of the symbols and fonts used in this manual are as follows:
Pay particular attention to text marked with this symbol.
Failure to observe this warning endangers your life, destroys the device, or may
damage other equipement
!
Supplementary information, remarks, and tips follow this symbol.
Text which follows this symbol describes activities that must be performed in the
order shown.
i
«Quotation marks» indicate names of chapters or terms
3
Safety notice
According to safety regulations, we draw your attention to the fact that these electronic ash units
are not designed for use outdoors, in damp or dusty conditions and should not be used after being
exposed to sudden temperature changes causing condensation. They must always be connected to
an earthed (grounded) mains supply.
On no account should any object be inserted into the ventilation.
The units may retain an internal charge for a considerable time even though disconnected from the
power supply.
Do not use in restricted area (like hospitals) and in explosive environnements.
Flash Tubes and Modelling lamps
• Flashtubes and modelling lamps in use are very hot!
• Never touch a ash tube or lamp before the unit cooled down and is disconnected from the mains.
• Do not re ashes from short distance (less than 1m) directed to a person and avoid looking
directly into the ashlight!
• Keep distance to ammable materials.
• Keep generally distance to operating units.
Transport
• Transport the ash unit with care and only in its original packaging or another corresponding
packaging t to protect it against knocks and jolts.
• Transport only in complete discharged conditions. Wait a minimum 30 minutes after removing
from mains supply before packaging and transportation.
• Never drop the ash unit (danger of breaking ash tubes).
Power cable
To guarantee safe operation, use the cable supplied.
• The cable has to be HAR-certied or VDE-certied. the mark HAR or VDE will appear on the outer
sheat.
• The cable set must be selected according to the rated current for your ash unit.
• Do not use a spider box to connect one or more ash units.
!
FLASH SYSTEMS STORE ELECTRICAL ENERGY IN CAPACITORS BY
APPLYING HIGH VOLTAGE.
FOR YOUR SAFETY, NEVER OPEN OR DISASSEMBLE YOUR FLASHES.
ONLY AN AUTHORISED SERVICE ENGINEER SHOULD OPEN OR ATTEMPT
TO REPAIR THE UNITS.
INTERNAL DEFECT CHARGE CAPACITORS MAY EXPLODE WHILST THE UNIT IS IN
USE, NEVER SWITCH ON A PROPER WORKING FLASH UNIT.
4
Before you start !
The Style RX unit voltage must correspond with your mains voltage. Style RX are delivered in 120V
or 230V versions.
Before connecting for the rst time, check to make sure that
your Modelling lamp coincides with the voltage line.
They must always be connected to an earthed ( grounded) mains supply.
All Style RX units have a bayonet mount and locking ring reector tting, for xing all Elinchrom and
Prolinca accessories.
Mount the unit securely to a suitable stand or support.
Remove the black protective cover (note: rst turn the locking ring A as shown, then rotate the
black cap cover B in the same direction).
Fitting a reector or accessory is the reverse of this action.
handle
A
locking
B
protective
cover
Operating instructions
1.Check that the modelling lamp voltage is correct.
2.Check that the mains switch (3) is in the OFF ("O" position).
3.Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET
4.Using the mains SWITCH (3) and switch the unit ON ("I" position).
5.Connect the synchro cord on the socket (6).
6.Select the power with the touch pad (11 - 12)
12
11
1
C
tilthead with locking
6
3
5
Control Panel
7
12
11
4
16
13
14 15
2
1
18
9
10
8
6
5
22
3
20
1921
17
Overview of controls
1.Mains inlet socket
2.Mains fuse (slow blow)
3.Mains Illuminated on/off switch
4.Modelling fuse (fast blow)
5.Open-ash
6.Synchro-sockets, Amphenol + jack 3.5 mm
7.Digital power display and
charge/discharge indicator
8. Acoustic recharging signal (Beep)
9. Slave cell switch on/off
10. Photocell receptor
11. Power adjustment in 1/10 f-stops, with
ADF
12. + Power adjustment in 1/10 f-stops
1 3. Modelling lamp switch
(on/off free or prop)
14.+ Modelling power control
15. - Modelling power control
16. Tilt head clamp
17. Knurled clamp screw
18. Handle
19. Stand 5/8-inch socket
20. Umbrella tube (only for EL
umbrellas, diameter 7 mm)
21.Supplementary locking for others
umbrellas
22. Socket for remote or PC - Multi Link
6
Mains Supply
With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug
of the original ELINCHROM mains cord into the mains socket (1).
Mains Switch
The switch should light up when the compact is switched on ("I" position).
(Switch off before removing the mains cord).
Troubleshooting
If the on/off switch (3) is ON ("I" position) but not illuminated,
switch off the unit and check the mains fuse (2).
If failed replace with the correct fuse and switch ON the unit.
This unit is protected by a thermal circuit breaker to avoid overheating.
Should this occur, the unit turns off automatically and cannot be red.
After a break for cooling, the ash will be ready again for operation.
See page 10 / Troubleshooting.
This equipment is not user serviceable and contains high voltages which are dangerous.
In the event of failure, please return the unit to an authorized Elinchrom service station.
Mains Fuse
Standard type 5 x 20 mm, (use only tempered fuse)
• Style 300RX : 5 AT
• Style 600RX : 6,3 AT
• Style 1200RX : 8 AT
Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and turn the fuse
holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately upon reconnection, return
the unit to an ELINCHROM service centre for a check-up.
(N.B. Please don't forget to check the correct rating of the fuse !).
Fuse for modelling light
Fast type 5 x 20mm, 2.5 AF
Switch off the unit and replace the blown fuse with a new one of the correct rating.
The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore
the ash tube.
Modelling fuse 4 AF
4
3
Mains switch
Mains fuse 8 AT
(Only tempered)
Mains socket
1
2
7
Modelling Light
The touch pad (14) controls the modelling lamp on/off and the proportional light.
Select the power with the touch pad (15). The modelling light output (100%) is achieved when
the power value is set to maximum.
Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the
light output is proportional to the selected ash power.
For all types of Style RX compact ash units, use maximum 250 - 300W modelling lamps.
230V Modelling lamps and fuses
UnitModelling lampCodeSocketFuseCode
Style 300RX250W halostar23018E272,5AF 19033
Style 600RX250W halostar23018E272,5AF 19033
Style 1200RX300W halogen23022GX 6,352,5AF 19033
120V Modelling lamps and fuses
UnitModelling lampCodeSocketFuseCode
Style 300RX150W halogen23037BA15D4 AF19035
Style 600RX150W halogen23037BA15D4 AF19035
Style 1200RX250W halogen23038BA15D4 AF19035
120V «Canada Version» Modelling lamps and fuses
UnitModelling lampCodeSocketFuseCode
Style 300RX150W halogen23012E274 AF19035
Style 600RX150W halogen23012E274 AF19035
Style 1200RX150W halogen23012E274 AF19035
230V Modelling lamp options:
23022
23101
23018
120V Modelling lamp:
23037
This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp
300W, GX 6.35 (code 23022) for Style 300 and 600 RX units.
If the modelling lamp does not light up.
1. The lament is broken after long use (replace lamp and fuse)
2. The lament is broken after shock (replace lamp and fuse)
3. An internal component failure (return the unit to customer service)
8
Digital Power Display
The actual ash power is displayed in a f-stop compatible format.
The power range is 6 f-stops. The digital display, provides continuous power indication of the
ash and modelling lamp. The controls cover a continuous output range from full power 1/1 to
1/32th in 1/10th, f-stop intervals.
During charging or discharging, the display "ashes". In case of overheating or malfunction,
the display shows "ER" for error.
Note:
This "Style 300RX, 600RX and 1200RX" units have an integrated discharge system, protected by a
thermic switch.
To avoid overheating, lower power settings, more than 2f-stop, can be discharged manually by releasing
the ash with the «Test» touch button.
Photocell
The photocell is actived when the green LED (on the touch pad 9) is illuminated.
When switched ON, the unit can be remotely triggered by another ash unit !
The Style BX photocell is specially designed to work under ambiant light conditions in your
studio. Direct light or other strong light sources may reduce the sensitivity of the cell.
In difcult situations e.g. blinding, sunlight or obstacles, the additional cell with 5 m cord
All RX units, Style RX, Digital RX, Ranger RX are equipped with the Remote Plug, to connect the
EL-Skyport Trigger and Remote System. With the EL- Skyport RX Trigger Set 19362,
the RX units can be triggered wireless, up to approximately 100 m distance. Apart from triggering,
the Transmitter offers modelling lamp on /off settings and ash power control in 1/10th steps.
By using the EL- Skyport Computer Remote / Trigger Set 19361, all RX functions can be
controlled and operated with a MAC° or Windows° computer.
19361
19362
For details of the most advanced wireless system please visit www.elinchrom.com > Products >
RX Multi Remote > EL-Skyport.
Sychronisation socket
The standard socket 3.5 mm mini-jack (6).
N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets.
ELINCHROM uses the low voltage (5 V) for security reasons.
Open ash "test"
Having pressed the touch pad to release a ash, the green «READY» light will
appear again once the unit is recharged. If the green light does not appear the
charge system could be defective.
Please contact and send to an authorized Elinchrom service.
Audible recharge signal
Select the function with the touch pad (8), the green indicator appears.
Once recycled an acoustic signal indicates that the compact unit is ready.
Troubleshooting
1. The mains switch (3) is ON ("I" position), but not light up:
• Switch OFF the unit and change the mains fuse (2)
• Use only time-lag fuse (16 AT), corresponding to the Style RX model
2. The switch (3) is lit, the open ash ready is lighting up but does not function.
• The ashtube in the ashhead may be faulty (see page 11)
• If replacing the ashtube does not solve the problem, the cause could be a
component failure => please return the unit to an authorised Elinchrom service.
3. The ON/OFF switch (3) is lit but the open ash signal (6) is not lit
• Temporary break for overheating, caused by fast ash sequences or ventilation
slots obturated
• Fan cooling defective => the unit turns off automatically and cannot be red any
more. After a break for cooling, the ash is ready again for operation.
• If after several minutes of break for cooling the ready signal (6) is not lit, the cause
could be a component failure. However, high voltage may remain on the capacitor
circuits. => DO NOT ATTEMPT TO REPAIR THE UNIT. In this case please send the unit
to an authorised Elincrom station.
Sync
Test and Ready
6
Beep
5
8
10
Flash tube replacement
If the unit does not ash but the ON/OFF switch indicates that there is power, it could be that the
ashtube needs replacing.
Note:
Flash tubes (Swiss quality) have a long life with average use, but multiashing in long sequences can cause
overheating of the electrodes leading to premature ageing, or perhaps the ash tube is broken or cracked.
To replace the Flash tube:
remove the tube
1. Switch off the mains switch
2. Remove the mains cable
3. Take the unit from its stand or lay it
horizontally on a rigid surface. It will need to
be held rmly whilst removing and replacing the tube.
4. Allow the ash tube and modelling lamp to cool
for several minutes. They may be very hot.
5. Carefully remove and store the modelling lamp.
Stand
Plug- in ashtube
(made in Switzerland)
(code 24029)
6. Put on the protective glove delivered with
your ash tube and remove:
A - rst the security spring trigger
B - the ash tube, by rmly pulling it away from the unit.
If the tube is broken, avoid cutting yourself and the
contact with
security spring
glove.
If the only part to grip is the electrode (e.g. a totally
smashed tube), withdraw using insulated pliers or pincers.
There is a full discharge security circuit tted, but
if the unit has had a heavy fall, internal damage
disconnecting a circuit could possibly happen.
correctly aligned
7. Take the new ash tube, code 24029 for Style 300BX-600RX, and
code 24068 for Style 1200RX.
A glove or "plastic protection" MUST BE USED - contact with your ngers on the glass,
will cause dark markings on the tube when it is used.
8. Check that the tube is correctly aligned (central) and that the trigger contact is gripping
the tube, rex the security spring.
9. Re-connect and test the unit as usual.
11
Features
• Locking bayonet ring for accessory and reector tting
• Tilthead whit 5/8" - inch stand socket
• Thermal safety
• User replaceable ash tube UV coated (5650°K)
• Halogen modelling lamp 250W, with E27 tting, and
300W/GX6.35for Style 1200RX (230V Version)
• Silent fan cooling
• Controls for: modelling on/off, cell on/off, acoustic signal on/off.
• Flash and modelling power control.
• «X» synchro jack socket 3,5 mm.
• Socket for Plug-In remote control.
• Auto dumping function. Automatic discharge of ash power
• Central umbrella tube plus external tting
• Acoustic recharging signal
• Mains cable
• Synchro cord of 5m (jack 3.5mm plug)
• Protective cover
• Total compatibility with all Elinchrom accessories
• Very fast recycling time
• Very short ash duration
Technical data 300RX600RX1200RX
Flash powerJ(Ws)3006001200
Power supply 230V VersionV all units 215-240
120V VersionV all units 110-120
F-stop, 1m, 100 ISO, with reector 48°GN64,190,1128,1
Control rangeJ(Ws)9-30018-60036-1200
Recycling time 230V Versions0,2-0,60,25-0,80,35-1,5
This ELINCHROM product will be repaired free of charge by the vending agent if during a period of
24 months from date of purchase its working order is impaired through a manufacturing or material
defect. The faulty product should be immediately sent to the authorized dealer or ELINCA agent.
This guarantee is not valid for equipment which has been misused, dismantled, modied or repaired
by persons not belonging to the ELINCA distribution network. It does not cover ash tubes, lamps
and the normal ageing of capacitors. No responsibilities can be accepted for damage resulting from
unsatisfactoıy operation of the equipment, such as wasted lm or other expenses.
i
Please „register“ your Elinchrom product online, under