Elinchrom Ranger Quadra, Ranger Quadra HYBRID Service Manual

Ranger Quadra
Service manual
English Elinchrom SA (74010) r8
Ranger Quadra
Elinchrom SA 2/11
TABLE OF CONTENT
TABLE OF CONTENT 2
1. SAFETY NOTICE 3
2. OPERATION INSTRUCTION 5
3. SPARE PARTS 6
3.1. Ranger Quadra 6
4. SERVICE MENU 10
4.1. Software configurations 10
4.2. Overview 10
4.3. How to operate in the Service menu 10
5. TROUBLE SHOOTING 11
6. KNOWN PROBLEMS AND FAQ 11
Ranger Quadra
Elinchrom SA 3/11
1. SAFETY NOTICE
The interior of the Elinchrom devices contain components carrying dangerous levels of electric charge, even though the unit has been disconnected from the mains or without
supply battery. Before all servicing operations or repairs, you must execute the
following discharge process:
DISCHARGE PROCESS OF THE UNIT BEFORE SERVICING
Note: The discharge process is best achieved with a suitable Elinchrom Service Kit (discharging box)
Elinchrom Service Kit for 230V : code number 11931 Elinchrom Service Kit for 120V : code number 11930
1. Set the device at minimum power
Note: One head must be connected to the device to activate the auto-discharge.
2. Switch off the unit, remove the head cables and
the battery.
3. Discharge the UBAT voltage on the X100 and
X101 connectors of the unit.
Ranger Quadra
Elinchrom SA 4/11
4. Discharge HHT A and HTT B of the outlet A and B
by using the RQ discharge cable
Note: Always use the RQ discharge cable alone on the discharging box.
5. Remove the rubber and the housing of the unit.
Note: do not touch the circuit boards until the end of this process
6. Remove the keyboard.
7. Discharge the HTD and HTD A on the following
points: Across C404 and C405
8. Now you can disassembling, repairing and
servicing safely.
Loading...