Elenos ET30000-5, ET15000-5, ET10000-5, ET5000, ET3500 User Manual

...
Page 1
ET30000-5 ET25000-5 ET20000-5 ET15000-5 ET10000-5
ET5000 ET3500 ET2500
(list of variations available in the manual)
SOLID STATE FM TRANSMITTER
Rev. 00- 17/11/2013
Cod. MAN1029UUK
USER MANUAL
Page 2
Via G. Amendola 9, 44028 Poggio Renatico Ferrara (Italy)
C.C.I.A.A. 101 216, Tax code and VAT reg. no. IT00415540384
Please remember to register the product purchased on http://www.elenos.com/product-registration/
Please contact technical support service for information and assistance:
Elenos
Ph : +39 0532 829965 Fax : +39 0532 829177 E-mail : [email protected] Internet web site : www.elenos.com
Elenos USA
1315 nw 98th Ct. Suite 9, 33172 Miami (Florida), Ph 1-855-ELENOS-0 (1-855-353-6670)
UNI EN ISO 9001:2008 certified company
Certificate No.102222A
Elenos APAC
53/64 Saracha Villa, Sansuk Muang Chonburi (Thailand), Ph +66 83 618-9333
Please complete the RMA form (ITA http://www.elenos.com/it/elenos-rma/ or ENG http://www.elenos. com/elenos-rma/) and provide the equipment serial number (indicated on the nameplate).
0051
For details please refer to the “EC Marking” section.
All rights reserved. No part of this manual can be reproduced in any form without prior written authorization from Elenos S.r.l.
Page 3
EC Declaration of Conformity
According to Directive 1999/5/EC (R&TTE)
We : ELENOS s.r.l. - via G.Amendola, 9 – 44028 Poggio Renatico (FE) - Italy Declare under our sole responsibility that the product: ET30000-5, ET27000/30-5, ET25000/30-5, ET20000/30-5, ET18000/30-5, ET15000/30-5, ET12000/30-5, ET10000/30-5, ET8000/30-5, ET7000/30-5, ET5000/30-5, ET4000/30-5, ET3500/30-5, ET3000/30-5 ET25000-5, ET20000/25-5, ET18000/25-5, ET15000/25-5, ET12000/25-5, ET10000/25-5, ET8000/25-5, ET7000/25-5, ET5000/25-5, ET4000/25-5, ET3500/25-5, ET3000/25-5, ET2500/25-5 ET20000-5, ET18000/20-5, ET15000/20-5, ET12000/20-5, ET10000/20-5, ET8000/20-5, ET7000/20-5, ET5000/20-5, ET4000/20-5, ET3500/20-5, ET3000/20-5, ET2500/20-5, ET2000/20-5 ET15000-5, ET12000/15-5, ET10000/15-5, ET8000/15-5, ET7000/15-5, ET5000/15-5, ET4000/15-5, ET3500/15-5, ET3000/15-5, ET2500/15-5, ET2000/15-5
ET10000-5, ET8000/10-5, ET7000/10-5, ET5000/10-5, ET4000/10-5, ET3500/10-5, ET3000/10-5, ET2500/10-5, ET2000/10-5 ET5000, ET4000/5, ET3500/5, ET3000/5, ET2500/5, ET2000/5, ET1800/5, ET1500/5, ET1200/5, ET1000/5, ET800/5, ET500/5 ET3500, ET3000/3.5, ET2500/3.5, ET2000/3.5, ET1800/3.5, ET1500/3.5, ET1200/3.5, ET1000/3.5, ET800/3.5, ET500/3.5 ET2500, ET2000/2.5, ET1800/2.5, ET1500/2.5, ET1200/2.5, ET1000/2.5, ET800/2.5, ET500/2.5 E30000-5, E27000/30-5, E25000/30-5, E20000/30-5, E18000/30-5, E15000/30-5, E12000/30-5, E10000/30-5, E8000/30-5, E7000/30-5, E5000/30-5, E4000/30-5, E3500/30-5, E3000/30-5 E25000-5, E20000/25-5, E18000/25-5, E15000/25-5, E12000/25-5, E10000/25-5, E8000/25-5, E7000/25-5, E5000/25-5, E4000/25-5, E3500/25-5, E3000/25-5, E2500/25-5 E20000-5, E18000/20-5, E15000/20-5, E12000/20-5, E10000/20-5, E8000/20-5, E7000/20-5, E5000/20-5, E4000/20-5, E3500/20-5, E3000/20-5, E2500/20-5, E2000/20-5 E15000-5, E12000/15-5, E10000/15-5, E8000/15-5, E7000/15-5, E5000/15-5, E4000/15-5, E3500/15-5, E3000/15-5, E2500/15-5,
E2000/15-5 E10000-5, E8000/10-5, E7000/10-5, E5000/10-5, E4000/10-5, E3500/10-5, E3000/10-5, E2500/10-5, E2000/10-5
With intended purpose: VHF FM broadcast transmitters and amplifiers And manufactured by: ELENOS s.r.l. To which this declaration relates is in conformity with the essential requirements and other relevant requirements of the R&TTE Directive (1999/5/CE). The product is in conformity with the following standards and/or other normative documents: Health and safety requirements pursuant to Article 3.1.a Standards applied: EN60215:1989+A1:1992+A2:1994 Protection requirements concerning electromagnetic compatibility pursuant to Article 3.1.b Standards applied: EN 301 489-1 V1.6.1 ; EN 301 489-11 V1.3.1 Measures for the efficient use of the radio frequency spectrum pursuant to Article 3.2 Standards applied: EN 302 018-2 V1.2.1
Supplementary information : Notified body involved: IMQ S.p.a. Technical file held by : Elenos s.r.l
Place and Date: Ferrara September 05, 2013 Responsible person : Leonardo Busi (Amministratore unico) Tel. +39 0532 829965 e-mail: [email protected]
Signature:
Page 4
Page 5
No. Date Description
00 17/12/2013 Original version
Revisions
Revisions
5
Page 6
Series models
Transmitter Amplifier Middle amplifier
stage
ET30000-5 E30000-5 E5000 6 30KW ETG20
ET27000/30-5 ET25000/30-5 ET20000/30-5 ET18000/30-5 ET15000/30-5 ET12000/30-5 ET10000/30-5 ET8000/30-5 ET7000/30-5 ET5000/30-5 ET4000/30-5 ET3500/30-5 ET3000/30-5
ET25000-5 E25000-5 E5000 5 25KW ETG20
ET20000/25-5 ET18000/25-5 ET15000/25-5 ET12000/25-5 ET10000/25-5 ET8000/25-5 ET7000/25-5 ET5000/25-5 ET4000/25-5 ET3500/25-5 ET3000/25-5 ET2500/25-5
E27000/30-5 E25000/30-5 E20000/30-5 E18000/30-5 E15000/30-5 E12000/30-5 E10000/30-5 E8000/30-5 E7000/30-5 E5000/30-5 E4000/30-5 E3500/30-5 E3000/30-5
E20000/25-5 E18000/25-5 E15000/25-5 E12000/25-5 E10000/25-5 E8000/25-5 E7000/25-5 E5000/25-5 E4000/25-5 E3500/25-5 E3000/25-5 E2500/25-5
E5000 E5000 E3500/5 E3000/5 E2500/5 E2000/5 E1800/5 E1500/5 E1200/5 E1000/5 E800/5 E800/5 E500/5
E4000/5 E4000/5 E3000/5 E2500/5 E2000/5 E1800/5 E1500/5 E1000/5 E800/5 E800/5 E800/5 E500/5
Combiner way
number
6
5
Maximum
output power
Equal to the
rated value
Equal to the
rated value
Driver
ETG20
ETG20
ET20000-5 E20000-5 E5000 4 20KW ETG20
ET18000/20-5 ET15000/20-5 ET12000/20-5 ET10000/20-5 ET8000/20-5 ET7000/20-5 ET5000/20-5 ET4000/20-5 ET3500/20-5 ET3000/20-5 ET2500/20-5 ET2000/20-5
6
E18000/20-5 E15000/20-5 E12000/20-5 E10000/20-5 E8000/20-5 E7000/20-5 E5000/20-5 E4000/20-5 E3500/20-5 E3000/20-5 E2500/20-5 E2000/20-5
Series models
E5000 E4000/5 E3000/5 E2500/5 E2000/5 E1800/5 E1500/5 E1000/5 E1000/5 E800/5 E800/5 E500/5
4
Equal to the
rated value
ETG20
Page 7
ET15000-5 E15000-5 E5000 3 15KW ETG20
ET12000/15-5 ET10000/15-5 ET8000/15-5 ET7000/15-5 ET5000/15-5 ET4000/15-5 ET3500/15-5 ET3000/15-5 ET2500/15-5 ET2000/15-5
E12000/15-5 E10000/15-5 E8000/15-5 E7000/15-5 E5000/15-5 E4000/15-5 E3500/15-5 E3000/15-5 E2500/15-5 E2000/15-5
E4000/5 E3500/5 E3000/5 E2500/5 E1800/5 E1500/5 E1200/5 E1000/5 E1000/5 E800/5
3
Equal to the
rated value
ETG20
ET10000-5 E10000-5 E5000 2 10KW ETG20
ET8000/10-5 ET7000/10-5 ET5000/10-5 ET4000/10-5 ET3500/10-5 ET3000/10-5 ET2500/10-5 ET2000/10-5
E8000/10-5 E7000/10-5 E5000/10-5 E4000/10-5 E3500/10-5 E3000/10-5 E2500/10-5 E2000/10-5
E4000/5 E3500/5 E2500/5 E2000/5 E1800/5 E1500/5 E1500/5 E1000/5
2
Equal to the
rated value
ETG20
Series models
7
Page 8
ET5000 E5000 E5000 - 5KW ETG20
ET4000/5 ET3500/5 ET3000/5 ET2500/5 ET2000/5 ET1800/5 ET1500/5 ET1200/5 ET1000/5 ET800/5 ET500/5
E4000/5 E3500/5 E3000/5 E2500/5 E2000/5 E1800/5 E1500/5 E1200/5 E1000/5 E800/5 E500/5
E4000/5 E3500/5 E3000/5 E2500/5 E2000/5 E1800/5 E1500/5 E1200/5 E1000/5 E800/5 E500/5
-
Equal to the
rated value
ETG20
ET3500 E3500 E3500 - 3.5KW ETG20
ET3000/3.5 ET2500/3.5 ET2000/3.5 ET1800/3.5 ET1500/3.5 ET1200/3.5 ET1000/3.5 ET800/3.5 ET500/3.5
E3000/3.5 E2500/3.5 E2000/3.5 E1800/3.5 E1500/3.5 E1200/3.5 E1000/3.5 E800/3.5 E500/3.5
E3000/3.5 E2500/3.5 E2000/3.5 E1800/3.5 E1500/3.5 E1200/3.5 E1000/3.5 E800/3.5 E500/3.5
-
Equal to the
rated value
ETG20
ET2500 E2500 E2500 - 2.5KW ETG20
ET2000/2.5 ET1800/2.5 ET1500/2.5 ET1200/2.5 ET1000/2.5 ET800/2.5 ET500/2.5
E2000/2.5 E1800/2.5 E1500/2.5 E1200/2.5 E1000/2.5 E800/2.5 E500/2.5
E2000/2.5 E1800/2.5 E1500/2.5 E1200/2.5 E1000/2.5 E800/2.5 E500/2.5
-
Equal to the
rated value
ETG20
8
Series models
Page 9
Contents
1 General information ................................................................................................................ 13
1.1 Intended use .................................................................................................................... 13
1.2 Transport .......................................................................................................................... 13
1.3 Unpacking ........................................................................................................................ 13
1.4 Storage ............................................................................................................................. 13
1.5 Decommissioning and disposal ....................................................................................... 14
1.6 Checking the product purchased ..................................................................................... 14
2 Product description ................................................................................................................. 15
2.1 Combiner/Splitter unit .................................................................................................... 15
2.2 Control unit (ET30000-5, ET25000-5, ET20000-5) ........................................................... 17
2.2.1 External connectors pin-out ..................................................................................... 19
2.2.1.1 Interface connector .......................................................................................... 19
2.2.1.2 Profiles connector ............................................................................................. 19
2.2.1.3 TC/TS connector................................................................................................. 20
2.2.1.4 Full scale values ................................................................................................ 21
2.2.1.5 Master connector .............................................................................................. 22
2.2.1.6 EIA485 connector .............................................................................................. 22
2.2.1.7 Aux1 connector ................................................................................................. 23
2.2.1.8 Dummy Load connector .................................................................................... 23
2.3 Control unit (ET15000-5, ET10000-5) .............................................................................. 24
2.4 Dummy load .................................................................................................................... 27
2.4.1 External connectors pin-out ..................................................................................... 28
2.4.1.1 Dummy Load connector .................................................................................... 28
2.5 Amplifiers ......................................................................................................................... 29
2.5.1 External connectors pin-out ..................................................................................... 31
2.5.1.1 EIA485/TELEMETRY connector ........................................................................... 31
2.5.1.2 TC/TS connector................................................................................................. 32
2.5.1.3 PROFILES connector ........................................................................................... 33
2.5.1.4 TCP/IP, RESERVED connector .............................................................................. 34
2.5.1.5 EIA485 connector .............................................................................................. 34
2.6 Exciters ............................................................................................................................. 35
2.7 System connections ......................................................................................................... 35
2.8 Technical datasheet ......................................................................................................... 36
2.9 Protections ....................................................................................................................... 52
2.9.1 Software protections ................................................................................................ 52
2.9.1.1 IPF (Intelligent Proportional Foldback) ............................................................. 52
2.9.1.2 IPC (Intelligent Power Control) ......................................................................... 52
2.9.1.3 Safety Management (“Lifextender” option) ® ................................................... 52
2.9.2 Hardware protections ............................................................................................... 54
2.10 Options ........................................................................................................................... 55
3 Use instructions ....................................................................................................................... 57
3.1 User interface ................................................................................................................... 57
3.1.1 Control unit user interface ........................................................................................ 57
3.1.1.1 Power setting .................................................................................................... 59
3.1.1.2 Frequency setting.............................................................................................. 59
Contents
9
Page 10
3.1.1.3 Input password.................................................................................................. 59
3.1.1.4 Profile ................................................................................................................ 59
3.1.1.5 Main alarm ........................................................................................................ 59
3.1.1.6 Temperatures .................................................................................................... 60
3.1.1.7 Main view.......................................................................................................... 60
3.1.1.8 Events list .......................................................................................................... 60
3.1.1.9 Events history .................................................................................................... 60
3.1.1.10 Dual drive ........................................................................................................ 61
3.1.1.11 Dual drive drive ............................................................................................... 61
3.1.1.12 Dual drive handler .......................................................................................... 61
3.1.1.13 Temperatures DL ............................................................................................. 61
3.1.1.14 485 speed set.................................................................................................. 62
3.1.1.15 Voltages........................................................................................................... 62
3.1.1.16 System info ..................................................................................................... 62
3.1.1.17 System time .................................................................................................... 62
3.1.1.18 Clock pwr target .............................................................................................. 63
3.1.1.19 Com. ID LC/RT disp. mode ............................................................................... 63
3.1.1.20 Temperature unit ............................................................................................ 63
3.1.1.21 Max reflected power ....................................................................................... 64
3.1.1.22 SWR foldback setting ...................................................................................... 64
3.1.1.23 No mains alarm setting .................................................................................. 64
3.1.1.24 Password setting ............................................................................................. 65
3.1.1.25 Password recovery .......................................................................................... 65
3.1.1.26 UPS settings .................................................................................................... 65
3.1.1.27 Uart 0,1,2 info ................................................................................................. 66
3.1.1.28 GSM field strength .......................................................................................... 67
3.1.1.29 -3dB alarm setting .......................................................................................... 67
3.1.1.30 String ID/Pager ID ........................................................................................... 67
3.1.1.31 Phone N.1 .. 5 ................................................................................................. 67
3.1.2 Amplifier user interface............................................................................................ 68
3.1.2.1 TX control panel ................................................................................................ 69
3.1.2.2 View TX parameters 1 ....................................................................................... 69
3.1.2.3 View TX parameters 2 ....................................................................................... 69
3.1.2.4 Alarms list ......................................................................................................... 70
3.1.2.5 Events history .................................................................................................... 70
3.1.2.6 Password ........................................................................................................... 70
3.1.2.7 Password setting ............................................................................................... 70
3.1.2.8 Password recovery ............................................................................................ 71
3.1.2.9 System config .................................................................................................... 71
3.1.2.10 System config 1 ............................................................................................... 72
3.1.2.11 Communication port set ................................................................................. 72
3.1.2.12 System info ..................................................................................................... 72
3.1.2.13 System time .................................................................................................... 73
3.1.2.14 Clock power target .......................................................................................... 73
3.1.2.15 Enable alarms SMS .......................................................................................... 74
3.1.2.16 Display alarms bit ........................................................................................... 74
3.1.2.17 User alarms data ............................................................................................. 75
3.1.2.18 User alarms timers .......................................................................................... 75
3.1.2.19 Lifextender ...................................................................................................... 76
3.1.2.20 GSM and modem service ................................................................................ 76
3.1.2.21 Phone N.1 to 4 / N.5 to 8 ............................................................................... 77
3.1.2.22 Uart 0,1 info .................................................................................................... 77
3.1.2.23 SMS Diagnostic ................................................................................................ 77
10
Contents
Page 11
3.1.3 Exciter user interface ................................................................................................ 78
3.2 Alarms/events list ........................................................................................................... 79
3.2.1 Control unit alarms/events list ................................................................................ 79
3.2.2 Amplifier alarms/events list .................................................................................... 80
3.2.3 Exciter alarms/events list ........................................................................................ 83
3.3 SMS list ............................................................................................................................. 84
3.3.1 SMS commands (submit) ......................................................................................... 84
3.3.2 Status/alarm SMS (reception) ................................................................................. 84
3.4 Externally connectable optional equipment ................................................................... 86
3.4.1 Connection to PC ...................................................................................................... 86
3.4.1.1 Control unit hyperterminal interface ............................................................... 87
3.4.1.2 Amplifier hyperterminal interface .................................................................... 95
3.4.1.3 Exciter hyperterminal interface ...................................................................... 102
3.4.2 Connection to telemetry ....................................................................................... 103
3.4.3 Connection to exchange unit and/or audio matrix ............................................... 104
3.4.4 Connection to Elenos E.BOX module ...................................................................... 107
4 Maintenance ......................................................................................................................... 109
4.1 Device overview ............................................................................................................ 109
4.1.1 ET30000-5 ............................................................................................................... 110
4.1.2 6-way combiner ..................................................................................................... 111
4.1.3 Control unit ............................................................................................................. 113
4.1.4 ETG20 exciter .......................................................................................................... 116
4.1.5 E5000 amplifier ...................................................................................................... 118
4.1.6 6-way dummy load ................................................................................................ 121
4.2 Settings .......................................................................................................................... 123
4.2.1 System addresses ................................................................................................... 123
4.2.2 Power supply Dip-switch in E5000 amplifier ......................................................... 124
4.3 Spare parts and mounting ............................................................................................. 126
4.4 Routine maintenance (cleaning, replacements, checks) .............................................. 126
4.5 Operating faults (symptoms, causes and remedies) .................................................... 127
Contents
11
Page 12
12 Contents
Page 13

1 General information

1.1 Intended use

The equipment referred to in this manual is solid state transmitters with adjustable output power from 0W to a maximum rated value (see Section “Series models”), to be used in the whole FM band between 87.5 and 108 MHz, in 10 kHz steps. The design of such equipment is based on SCALABILITY: it envisages the reuse on different scale levels of resources used on a basic model (the E5000 amplifier), so as to obtain higher transmission powers. The same technology, same user interfaces and same components within each module mean more economical spare part and repair management, more economical ope- rator training and experience which can be easily shared with others. The available options are as follows: STEREO, AES/EBU (both with integrated MPX), ac­cording to the relative modulator version. The distinctive characteristics of Elenos products remain constant: ECOSAVING, ICEFET, VSWR PEAK HOLD, monitoring possibility, protection against corrosion, etc.. The LIFEXTENDER functionality can be added.

1.2 Transport

The equipment must only be transported in its original packaging. However, although it has been designed to prevent the machine being damaged, even in the event of incorrect manoeuvres, it is recommended to respect the “HIGH/ LOW” direction and not to subject it to impact. Ensure that the transport and lifting equipment are suitable for supporting the load.

1.3 Unpacking

The personnel in charge of handling the load must use protective gloves and accident­prevention footwear. Before lifting or moving the equipment or any of its parts, check that the operating area has been cleared, also considering a safe area in order to prevent damage to people and/or properties that could be within the manoeuvring radius.

1.4 Storage

Should it be necessary to store the equipment for any reason, it is necessary that:
• in the storage area, the temperature is between -20° and +55°C, with humidity of no more than 90% at 55°C;
• the equipment is disconnected from energy sources;
• the equipment is clean and there are no dust deposits;
• the equipment is covered with a waterproof sheet.
General information
13
Page 14

1.5 Decommissioning and disposal

For all the aspects regarding the disposal of the product, please refer to the specific European Directives.
Please note that the equipment DOES NOT CONTAIN POLLUTANT OILS.

1.6 Checking the product purchased

Before installing the equipment, it is important to check that it was not damaged du­ring transport or storage. Check that all standard components and accessories ordered have been delivered correctly, otherwise contact Elenos s.r.l.
In this case, the package must contain at least the following:
• n°1 piece of equipment from the ET30000-5, ET25000-5, ET20000-5, ET15000-5, ET10000-5, ET5000, ET3500, ET2500 series;
• n°1 “Identification and Quick Start” manual, which we recommend keeping with the product;
It may also contain:
• n°1 “User” manual;
• n°1 CD containing all the documentation relative to Elenos s.r.l. manuals;
• n°1 PC connection cable.
Cables, spare parts and other accessories may be requested from Elenos S.r.l. or Elenos retailers.
14 General information
Page 15

2 Product description

2.1 Combiner/Splitter unit

3
1 12
4
6 7 7
8 8 8 8
5
9 9 9 9
7 7
Product description
15
Page 16
1 FAN - cooling fans. There are two, 12-28Vdc, 306M3/h max. 2 GRILL - ventilation grille. 3 RF OUT - RF output connector 3”+1/8 4 PWS - 3W3 connector for the fan power supply. 5 AUX1 - unused connector. 6 SPLITTER IN - N connector for RF splitter input. 7 LOAD - four 7/16 connectors for unbalanced load outputs. 8 SPLITTER OUT - four N connectors for RF splitter outputs. 9 POWER IN - four 7/8 connectors for RF amplifier inputs.
16 Product description
Page 17

2.2 Control unit (ET30000-5, ET25000-5, ET20000-5)

8
2 3
14
15
16 17
18 19
20
2321 22
1
9 10 11
4 5 6 7
12
11
13
27 27262524
Product description
17
Page 18
1 GRILL - ventilation grille. 2 DISPLAY - display showing the operating parameters and selected functions using the
encoder. 3 ENCODER - multifunction knob allowing navigation through the function menus and modification of the operating parameters. 4 KEY SELECTOR - it can be set to LOCAL (controllable through the front panel) or REMO­TE (controllable via PC) mode, by turning the key supplied with the equipment. 5 WARNING LIGHTS - LED list:
• FAULT (red) _ this warning light is on when the equipment is considered to be in “FAILURE”;
• ON AIR (green) _ this warning light is on when the apparatus is broadcasting;
• ST-BY (yellow) _ this warning light is on when the apparatus is not broadcasting;
• LOCAL (blue) _ this warning light is on during local programming;
• MAINS (green) _ this warning light is on when power is supplied.
6 INTERFACE - B9 F connector for connection with telemetry according to the EIA485 standard, or to a PC. 7 RF MONITOR - BNC connector for connection with external measurement tools, al­lowing to the RF signal to be taken at a low level (0dBm at scale bottom). This monitor is not calibrated, therefore it is not guaranteed that the output level stays constant as frequency changes. It CANNOT be used for measuring the output power, or for measu-
ring the harmonic components.
9 PROGRAMMING LEVER – Located on the right hand side of the panel facing the ma­chine. It can be moved by means of a flat screwdriver upwards (in running mode) and downwards (in program mode).
9 VDE - VDE socket for the equipment power supply. 10 EXCITER DUMMY LOAD - N connector for internal unbalanced load input. 11 RF IN - two N connectors for modulator RF inputs. 12 RF OUT - N connector for RF splitter output. 13 DUMMY LOAD - N connector for reserve exciter load. 14 PROFILES - DB25 F connector. Normally unused. It is used for the selection of profiles
stored (in the case of apparatus as a reserve).
15 TC/TS - DB25 F connector for remote control and remote telesignalling. 16 MASTER - DB25 F connector for interface with amplifiers and modulators. 17 SLAVE - unused connector. 18 INTERLOCK - unused connector. 19 IEEE485 - DB9 F connector for connection with telemetry according to the EIA485
standard.
20 AUX 1 - DB9 F connector for environment temperature probe. 21 FWD- BCN connector for forward power input. 22 REF - BNC connector for reflected power input. 23 MONITOR - BNC connector for low level signal input in antenna. 24 DUMMY LOAD - DB9 F connector for unbalanced load connection. 25 PWS DUMMY LOAD - 3W3 connector for the unbalanced load fan power supply. 26 PWS COMBINER - 3W3 connector for combiner fan power supply. 27 FAN - cooling fans. There are two, 12-28Vdc, 306M3/h max.
18 Product description
Page 19
13 25 12 24 11 23 10 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1

2.2.1 External connectors pin-out

2.2.1.1 Interface connector
Connector Pin Meaning Notes
With a cable to CN3
1 TX_1 Filtered output 485
on E3K 7A044 board
2 /TX_1 Filtered output 485
Differential signal “positive”
Differential signal “negative”
5 9 4 8 3 7 2 6 1
3 RX_1 Filtered input 485
Differential signal “positive”
4 / RX_1 Filtered input 485
Differential signal
“negative” 5 Common ground 6 Common ground 7 Common ground 8 Common ground 9 Common ground
2.2.1.2 Profiles connector
Connector Pin Meaning Notes
CN1 on E10K5A070 board
1 TC_CH1 F_TC_CH0 2 TC_CH3 F_TC_CH2 3 TC_CH5 F_TC_CH4 4 - No connected 5 Common ground 6 TS_E_M_CH6 Common ground if JP4
is in shot circuit 7 - No connected 8 TS_E_M_CH3 Common ground if JP2
is in shot circuit 9 Common ground 10 Common ground 11 TS_CH5 F_TS_CH4 12 TS_CH F_TS_CH2 13 TS_CH1 F_TS_CH0 14 TC_CH2 F_TC_CH1 15 TC_CH4 F_TC_CH3 16 TC_CH6 F_TC_CH5 17 - No connected 18 Common ground 19 TS_E_M_CH5 Common ground if JP3
is in shot circuit 20 TS_E_M_CH4 Common ground if JP1
is in shot circuit 21 Common ground 22 Common ground 23 TS_CH6 F_TS_CH5 24 TS_CH4 F_TS_CH3 25 TS_CH2 F_TS_CH1
Product description
19
Page 20
13 25 12 24 11 23 10 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1
2.2.1.3 TC/TS connector
Connector Pin Meaning Notes
CN1 on E3K NA041board
1 Enable (interlock) Command to state
2 TX ON Command pulse
500ms
3 TX OFF Command pulse
500ms
V
4 Reflected power Output in voltage
5 Common ground Connected to the
6 RX- Com2 EIA485/422
7 - Not connected
8 TX- Com2 EIA485/422
Pin grounded = active command
Pin grounded = active command
Pin grounded = active command
See full scale values
frame
V
open collector
open collector
open collector
9 Common ground Connected to the
frame
10 IPA (Current amplifier) Output in voltage
NOT USED
11 Fault main Power supply FAULT
status The pin must be pow­ered externally. “Open” Status --> Fault active
12 TX ON Signaling output
The pin must be pow­ered externally. “Closed to ground” status --> TX ON
13 Warning/Bad audio Signaling output
The pin must be pow­ered externally. “Closed to ground” status --> Active Warning The operation is af­fected by settings of the machine
14 Reset alarm Command pulse
Pin grounded = active command
15 - Reserved for Elenos
16 - Reserved for Elenos
V
17 Forward power Output in voltage
See full scale values
18 Common ground Connected to the
frame
19 RX+ Com2 EIA485/422
20 TX+ Com2 EIA485/422
21 Common ground Connected to the
frame
20
V
Product description
22 VPA (Voltage ampli-
fier)
Output in voltage NOT USED
Page 21
23 Bad audio Signaling output
open collector
The pin must be pow-
ered externally.
“Closed to ground”
status --> Active
alarm
open collector
24 /FLT (reversed polar-
ity)
Signaling output
The pin must be pow-
ered externally.
“Open” Status --> Ac-
tive alarm
The operation can be
affected by the set-
tings of the machine 25 Remote Signaling output
open collector
The pin must be pow-
ered externally.
“Closed to ground”
status --> Remote
signal active
2.2.1.4 Full scale values
The nominal full scale corresponds to +4 V, with over stroke of up to more than +4.5 (max +5 V).
ET30000-5
Parameters Full scale Scale factor Resolution
Forward power 30000W 7500W * V Full scale/204 Reflected power 3000W 750W * V
ET25000-5
Parameters Full scale Scale factor Resolution
Forward power 25000W 6250W * V Full scale/204 Reflected power 2500W 625W * V
ET20000-5
Parameters Full scale Scale factor Resolution
Forward power 20000W 5000W * V Full scale/204 Reflected power 2000W 500W * V
ET15000-5
Parameters Full scale Scale factor Resolution
Forward power 15000W 3750W * V Full scale/204 Reflected power 1500W 375W * V
ET10000-5
Parameters Full scale Scale factor Resolution
Forward power 10000W 2500W * V Full scale/204 Reflected power 1000W 250W * V
Product description
21
Page 22
13 25 12 24 11 23 10 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1
2.2.1.5 Master connector
Connector Pin Meaning Notes
CN2 on E3K NA041 board
1 TS_INTLCK Interlock 2 TS_FLTAUDIO_TX1 Fault audio exciter1 3 - Free 4 TC_TX2_STATUS Status exciter2 5 TC_TX1_STATUS Status exciter1 6 TX0­7 - Not connected 8 RX0­9 - Free 10 TS_FLTAUDIO_TX2 Fault audio exciter2 11 TS_COAX_TX1 Interlock exciter1 12 TS_TX2_OFF Turn off exciter2 13 TS_TX1_OFF Turn off exciter1 14 TS_ALM_RST Alarm reset 15 TS_MOD_ON Turn on modulation 16 TC_TX2_FAULT Fault exciter2 17 TC_TX1_FAULT Fault exciter1 18 Common ground 19 TX0+ 20 RX0+ 21 Common ground 22 - Not connected 23 TS_COAX_TX2 Interlock exciter2 24 TS_TX2_ON Turn on exciter2 25 TS_TX1_ON Turn on exciter1
2.2.1.6 EIA485 connector
5 9 4 8 3 7 2 6 1
22
Connector Pin Meaning Notes
CN8 on E3K NA041 board
1 TX1+ Telemetry 2 TX1­3 RX1+ 4 RX1­5 Common ground 6 Common ground 7 Common ground 8 Common ground 9 Common ground
Product description
Page 23
2.2.1.7 Aux1 connector
Connector Pin Meaning Notes
With a cable to J9 on E20K0A912 board
1 +12V 2 Common ground 3 TEMP 4 Common ground 5 Not connected 6 Not connected 7 Not connected 8 Not connected 9 Not connected
2.2.1.8 Dummy Load connector
Connector Pin Meaning Notes
With a cable to CN5 on E3K FA044 board
1 Common ground 2 +12V 3 TEMP1 4 TEMP2 5 TEMP3 6 TEMP4 7 TEMP5 8 TEMP6 9 INTERLOCK
5 9 4 8 3 7 2 6 1
5 9 4 8 3 7 2 6 1
Product description
23
Page 24

2.3 Control unit (ET15000-5, ET10000-5)

888 9
1
2 3
4 5 6 7
24
Product description
Page 25
18
17
16
15
14
13 13 13
19 11 20
9 12
8 8 8
13 14 13
1
Product description
25
Page 26
1 GRILL - ventilation grille. 2 DISPLAY - display showing the operating parameters and selected functions using the
encoder. 3 ENCODER - multifunction knob allowing navigation through the function menus and modification of the operating parameters. 4 KEY SELECTOR - it can be set to LOCAL (controllable through the front panel) or REMO­TE (controllable via PC) mode, by turning the key supplied with the equipment. 5 WARNING LIGHTS - LED list:
• FAULT (red) _ this warning light is on when the equipment is considered to be in “FAILURE”;
• ON AIR (green) _ this warning light is on when the apparatus is broadcasting;
• ST-BY (yellow) _ this warning light is on when the apparatus is not broadcasting;
• LOCAL (blue) _ this warning light is on during local programming;
• MAINS (green) _ this warning light is on when power is supplied.
6 INTERFACE - B9 F connector for connection with telemetry according to the EIA485 standard, or to a PC. 7 RF MONITOR - BNC connector for connection with external measurement tools, al­lowing to the RF signal to be taken at a low level (0dBm at scale bottom). This monitor is not calibrated, therefore it is not guaranteed that the output level stays constant as frequency changes. It CANNOT be used for measuring the output power, or for measu-
ring the harmonic components.
8 FAN - cooling fans. There are three on the front panel, 12-28Vdc, 441Mc/h max. There are three on the front panel on the rear panel (only on ET15000-5), 12-28Vdc, 306Mc/h max. 9 PROGRAMMING LEVER – Located on the right hand side of the panel facing the ma­chine. It can be moved by means of a flat screwdriver upwards (in running mode) and downwards (in program mode).
10 VDE - VDE socket for the equipment power supply. 11 SPLITTER OUT CONNECTORS - BNC connector for RF output from splitter. There are
two in ET10000-5, three in ET15000-5.
12 EXCITER IN CONNECTORS - N connector for RF input from exciter. There are two. 13 AMPLIFIER IN - 7/8” connector for RF input from amplifiers. 14 RF OUT - 3” 1/8 connector (on ET15000-5), 1” 5/8 (on ET10000-5). 15 PROFILES (see paragraph 2.2.1.2) - DB25 F connector. Normally unused. It is used for
the selection of profiles stored (in the case of apparatus as a reserve). 16 TC/TS (see paragraph 2.2.1.3/ 2.2.1.4) - DB25 F connector for remote control and remote telesignalling. 17 MASTER (see paragraph 2.2.1.5) - DB25 F connector for interface with amplifiers and modulators.
18 SLAVE - unused connector. 19 INTERLOCK - unused connector. 20 IEEE485 (see paragraph 2.2.1.6) - DB9 F connector for connection with telemetry
according to the EIA485 standard.
26 Product description
Page 27

2.4 Dummy load

2 2 2
1
2 2 23
4
5 5 5 5
Product description
27
Page 28
1 GRILL - ventilation grille. 2 FAN - cooling fans. There are six, 12-28Vdc, 441M3/h max. 3 DUMMY LOAD - DB9 M connector for control unit connection. 4 PWS DUMMY LOAD - 3W3 connector for power supply. 5 RF IN - four 7/16 connectors for RF combiner inputs.

2.4.1 External connectors pin-out

2.4.1.1 Dummy Load connector
5 9 4 8 3 7 2 6 1
Connector Pin Meaning Notes
CN1 on XNK CA452 board
1 Common ground 2 +12V 3 TEMP1 4 TEMP2 5 TEMP3 6 TEMP4 7 TEMP5 8 TEMP6 9 INTERLOCK
28
Product description
Page 29
2.5 Amplifiers
81818 918 9
1
2 3
45 6 7
17
14 15 16
12 1110 13
1818 18
Product description
29
Page 30
1 GRILL - ventilation grille. 2 DISPLAY - display showing the operating parameters and selected functions using the
encoder. 3 ENCODER - multifunction knob allowing navigation through the function menus and modification of the operating parameters. 4 KEY SELECTOR - it can be set to LOCAL (controllable through the front panel) or REMO­TE (controllable via PC) mode, by turning the key supplied with the equipment. 5 WARNING LIGHTS - LED list:
• MAINS (green) _ this warning light is on when power is supplied;
• ON AIR (green) _ this warning light is on when the apparatus is broadcasting;
• ST-BY (yellow) _ this warning light is on when the apparatus is not broadcasting;
• EXCITER OK (yellow) _ this warning light is on fixed in conditions of correct driving;
• FAULT (red) _ this warning light is on when the equipment is considered to be in “failure”;
• LOCAL (light blue) _ this warning light is on during local programming.
6 BUTTONS/CONTROLS – Button list :
• LIFEXTENDER _ This button displays the state of the LifExtender optional function (active/inactive, days of activity, critical days of activity);
• OFF _ this button allows the equipment to be put on Stand-by;
• ON_ this button allows the equipment to be put On Air;
• ESC _ this button moves the user back previous level in the menu.
7 EIA485/TELEMETRY – DB9 F connector for connection with telemetry according to the EIA485 standard, or with a PC. 8 RF MONITOR – BNC connector for connection with external measurement tools, al­lowing to collect the RF signal at low level (0dBm at scale bottom). This monitor is not calibrated, therefore it is not guaranteed that the output level stays constant as the frequency changes.
It CANNOT be used for measuring the output power, nor for measuring the harmonic components.
9 PROGRAMMING LEVER – Located on the right hand side of the panel facing the ma­chine. It can be moved by means of a flat screwdriver upwards (in program mode) and downwards (in running mode). For the detailed loading procedure of the software, ask the manufacturer for the technical bulletin No.125. 10 POWER SUPPLY TERMINAL BOARD – Terminal board with 6 contacts connecting the three internal power supplies. For details of the connection mode, please refer to sec­tion “Quick instructions for commissioning”. 11 EARTHING SCREW – Eyelet for earthing the equipment, located behind the flange of the output coaxial connector.
12 RF IN - N type. 13 RF OUT - 7/8” type. 14 TC/TS – DB25 F connector for remote control and remote telesignalling. 15 PROFILES – DB25 F connector to be used as reserve equipment in an N+1 system. 16 TCP/IP, RESERVED – Connector for remote connection functions. 17 EIA485 – DB9 F connector for connection with telemetry according to the EIA485
standard.
18 FAN - cooling fans. There are six, 120x120x38 mm, 12-28Vdc, 306Mc/h max.
30 Product description
Page 31

2.5.1 External connectors pin-out

2.5.1.1 EIA485/TELEMETRY connector
Connector Pin Meaning Notes
CN3 on TG5K2A881 board
1 Com1 TX+ EIA485/422 2 Com1 TX- EIA485/422 3 Com1 RX+ EIA485/422 4 Com1 RX- EIA485/422 5 Common ground Connected to the
6 Common ground Connected to the
7 Common ground Connected to the
8 Common ground Connected to the
9 Common ground Connected to the
5 9 4 8 3 7 2 6 1
frame
frame
frame
frame
frame
Product description
31
Page 32
13 25 12 24 11 23 10 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1
2.5.1.2 TC/TS connector
Connector Pin Meaning Notes
CN1 on TG2U1A899 board
1 Enable (interlock) Command to state
2 TX ON Command pulse
500ms
3 TX OFF Command pulse
500ms
V
4 Reflected power Output in voltage
5 Common ground Connected to the
6 RX- Com2 EIA485/422
7 - Not connected
8 TX- Com2 EIA485/422
Pin grounded = active command
Pin grounded = active command
Pin grounded = active command
See full scale values
frame
V
open collector
open collector
open collector
9 Common ground Connected to the
frame
10 IPA (Current amplifier) Output in voltage
See full scale values
11 Fault main Power supply FAULT
status The pin must be po­wered externally. “Open” Status → Fault active
12 TX ON Signaling output
The pin must be po­wered externally. “Closed to ground” status → TX ON
13 Warning/Bad audio Signaling output
The pin must be po­wered externally. “Closed to ground” status → Active Warning
The operation is affected by settings of the machine
14 Reset alarm Command pulse
Pin grounded = active command
15 UPS target Command to state
16 - Reserved for Elenos
V
17 Forward power Output in voltage
See full scale values
18 Common ground Connected to the
frame
19 RX+ Com2 EIA485/422
20 TX+ Com2 EIA485/422
32
V
Product description
21 Common ground Connected to the
frame
22 VPA (Voltage ampli-
fier)
Output in voltage See full scale values
Page 33
open
13 25 12 24 11 23 10 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1
collector
23 Bad audio Signaling output
The pin must be po­wered externally. “Closed to ground” status → Active alarm
open collector
24 /FLT (reversed pola-
rity)
Signaling output The pin must be po­wered externally. “Open” Status → Acti- ve alarm
The operation can be affected by the set­tings of the machine
25 Remote Signaling output
open collector
The pin must be po­wered externally. “Closed to ground” status → Remote signal active
2.5.1.3 PROFILES connector
Connector Pin Meaning Notes
CN1 on TG2U2A899 board
1 Channel 1 Command pulse 2 Channel 3 Command pulse 3 Channel 5 Command pulse 4 Riserve Command pulse 5 Common ground Connected to the
frame
6 Common ground Connected to the
frame 7 - Not connected 8 Common ground Connected to the
frame 9 Common ground Connected to the
frame 10 Common ground Connected to the
frame 11 Channel 5 status Signaling output 12 Channel 3 status Signaling output 13 Channel 1 status Signaling output 14 Channel 2 Command pulse 15 Channel 4 Command pulse 16 Channel 6 Command pulse 17 - Not connected 18 Common ground Connected to the
frame 19 Common ground Connected to the
frame 20 Common ground Connected to the
frame 21 Common ground Connected to the
frame 22 Common ground Connected to the
frame 23 Channel 6 status Signaling output 24 Channel 4 status Signaling output 25 Channel 2 status Signaling output
Product description
33
Page 34
SH1 SH2
2.5.1.4 TCP/IP, RESERVED connector
1 2 3 4 5 6 7 8
Connector Pin Meaning Notes
CN3 on TG2U2A899 board
1 ETHERNET interface 2
10Base-T or 100Base-
TX 3 4 5 6 7 8
CN2 on TG2U2A899 board
1 Reserved 2 3 4 5 6 7 8
2.5.1.5 EIA485 connector
5 9 4 8 3 7 2 6 1
Connector Pin Meaning Notes
CN2 on board TG2U1A899
1 Com1 TX+ EIA485/422 2 Com1 TX- EIA485/422 3 Com1 RX+ EIA485/422 4 Com1 RX- EIA485/422 5 Common ground Connected to the
6 Common ground Connected to the
7 Common ground Connected to the
8 Common ground Connected to the
9 Common ground Connected to the
frame
frame
frame
frame
frame
34
Product description
Page 35

2.6 Exciters

For further information, please consult the specific manual for the exciters.

2.7 System connections

For further information, please consult the “Composition” paragraph in the Quick Start manual.
35Product description
Page 36

2.8 Technical datasheet

Datasheet
FM TRANSMITTER HIGH POWER | ET30000
FM TRANSMITTER HIGH POWER | ET30000
COMPOSITION
Exciter (Indium series) n°1 Exciter Indium Series
Amplifier n°6 Amplifier E5000 Indium Series
Combiner n°1 6-way combiner IN 5000 - OUT 30000 with
Dummy load n°1 dummy load (4U)
Control unit n°1 control unit (4U).
RF output connector 3+1/8”
Circuit breaker box 6U (on rear panel)
GENERAL DATA
Output nominal maximum power 30000 W
Output power range 3000 ÷ 30000 W
Operating band 87.5 ÷ 108 MHz
Dimensions: Rack units min. 40U
Dimensions: W - H - D 56.5 - 228.2 - 107.8 cm (with fan)
Weight 460 kg
RF power stage technology ICEFET & ECOSAVING
Automatic power RF control Stabilized output power value on the set value
Overall output power RF stability +/- 0.1 dB
Cooling system Forced air-cooling
Air outlet On the top. Cooling flow 4000 m3/h (depending on
RS232/RS485 Yes. Connector DB9 female
Points of measure RF Sample - MPX Monitor
AUDIO PERFORMANCE
MPX input level +15/-10 dBu for 75 KHz standard deviation
MPX level adjustment Soft adjust 0.1 dB steps from front panel
MPX input impedance 5 KΩ selectable
L/R input level +15/-10 dBu for 75 KHz standard deviation
L/R level adjustment Soft adjust 0.1 dBu steps from front panel
L/R Input Impedance Selectable 10 K - 600 Ω, balanced
AES/EBU input resolution 24 bits
AES/EBU input sample rate 32,44.1,48,96 KHz Automatically selected
AES/EBU input level -20 dBFS - 0 dBFS
AES/EBU input impedance 110 Ω balanced
AES/EBU-Analog input automatic changeover Yes
PILOT Amplitude adjustment Soft adjust 0.05% steps from front panel
PILOT Phase adjustment Soft adjust 0.01 degree steps from front panel
PILOT tone frequency 19 KHz
PILOT tone deviation Soft adjust +/- 7.5 KHz
PILOT tone frequency stability +/- 1 Hz
THD+N (stereo/mono operation) < 0.05% with 75 KHz frequency deviation
Pre-emphasis 0/25/50/75 microseconds, selectable
Pre-emphasis tolerance +/- 0.1 dB
FM S/N (MPX operation) 82 dB
FM S/N CCIR (stereo/mono operation) > = 72 dB weighted
Asynchronous AM S/N unweighted > = 55 dB a 400 Hz, 75 us de-emphasis
Synchronous AM S/N > = 50 dB a 400 Hz, 75 us de-emphasis
Amplitude-frequency characteristic (stereo/mono operation)
n°2 Exciter Indium Series dual drive configuration
external CPU/control unit and load (4U)
From the frontal panel/from PC, a careful analysis of the functioning through detailed measurement of currents, voltages, temperatures and powers
environment)
< 0.05% with 100 KHz frequency deviation 30 Hz to 15 KHz
20 Hz to 23 KHz @ 53 KHz - detector RMS
> = 72 dB unweighted 400 Hz, 75 KHz frequency deviation, quasi-peak detector, 50 us de-emphasis
+/- 0.1 dB (without pre-emphasis) +/- 0.1 dB (with pre-emphasis) 20 Hz to 15 KHz, @ 400 Hz
single drive
configuration
36
Product description
Page 37
FM TRANSMITTER HIGH POWER | ET30000
Stereo Crosstalk (typical) 60 dB
Linear crosstalk >60 db 20 Hz to 15 KHz
Intermodulation distortion <0.05% Measured with two of tones 1 KHz & 1.3 KHz,
Class of emission F3
Stereo emission According to ITU-R reccomendation
EXCITER PERFORMANCE
PLL lock time <10 sec
Frequency deviation +/- 75 KHz 0.1 dB steps adjustable
Maximum frequency deviation +/- 150 KHz
Frequency stability 1 ppm
RF Frequency steps 10 KHz
Phase Response +/- 0.1 degree from linear phase;
INSTALLATION REQUIREMENTS
Power supply 380 V or 400 V,Threephase + neutral wire 50-60 Hz*
Power consumption (typical) 44 KW
Current consumption (typical @230VAC/Threephase)
Overall efficiency (typical from - 3 dB to Pman)
Power factor >0.95
Current consumption (typical @380VAC/Threephase)
ENVIRONMENT
Temperature range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating) 95% @ 40 °C, 104 °F
Humidity range (non operating) 90% @ 55 °C, 131 °F
Altitude range (operating) <3000 meters / <9840 Feet
Altitude range (non operating) <15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control Yes
Remote Control at clean contacts Yes
SNMP option Yes (external)
@ 400 Hz to 10 KHz
ratio 1:1 at 100% modulation
450 (pilot tone)
20 KHz to 100 KHz
210 V, Threephase (WYE without neutral)*
* to be specified when placing the order
110 A
68%
64 A
Product description
37
Page 38
Datasheet
FM TRANSMITTER HIGH POWER | ET25000
FM TRANSMITTER HIGH POWER | ET25000
COMPOSITION
Exciter (Indium series) n°1 Exciter Indium Series
Amplifier n°5 Amplifier E5000 Indium Series
Combiner n°1 5-way combiner IN 5000 - OUT 25000 with
Dummy load n°1 dummy load (4U)
Control unit n°1 control unit (4U).
RF output connector 3+1/8”
Circuit breaker box 6U (on rear panel)
GENERAL DATA
Output nominal maximum power 25000 W
Output power range 2500 ÷ 25000 W
Operating band 87.5 ÷ 108 MHz
Dimensions: Rack units min. 40U
Dimensions: W - H - D 56.5 - 228.2 - 107.8 cm (with fan)
Weight 400 kg
RF power stage technology ICEFET & ECOSAVING
Automatic power RF control Stabilized output power value on the set value
Overall output power RF stability +/- 0.1 dB
Cooling system Forced air-cooling
Air outlet On the top. Cooling flow 4000 m3/h (depending on
RS232/RS485 Yes. Connector DB9 female
Points of measure RF Sample - MPX Monitor
AUDIO PERFORMANCE
MPX input level +15/-10 dBu for 75 KHz standard deviation
MPX level adjustment Soft adjust 0.1 dB steps from front panel
MPX input impedance 5 KΩ selectable
L/R input level +15/-10 dBu for 75 KHz standard deviation
L/R level adjustment Soft adjust 0.1 dBu steps from front panel
L/R Input Impedance Selectable 10 K - 600 Ω, balanced
AES/EBU input resolution 24 bits
AES/EBU input sample rate 32,44.1,48,96 KHz Automatically selected
AES/EBU input level -20 dBFS - 0 dBFS
AES/EBU input impedance 110 Ω balanced
AES/EBU-Analog input automatic changeover Yes
PILOT Amplitude adjustment Soft adjust 0.05% steps from front panel
PILOT Phase adjustment Soft adjust 0.01 degree steps from front panel
PILOT tone frequency 19 KHz
PILOT tone deviation Soft adjust +/- 7.5 KHz
PILOT tone frequency stability +/- 1 Hz
THD+N (stereo/mono operation) < 0.05% with 75 KHz frequency deviation
Pre-emphasis 0/25/50/75 microseconds, selectable
Pre-emphasis tolerance +/- 0.1 dB
FM S/N (MPX operation) 82 dB
FM S/N CCIR (stereo/mono operation) > = 72 dB weighted
Asynchronous AM S/N unweighted > = 55 dB a 400 Hz, 75 us de-emphasis
Synchronous AM S/N > = 50 dB a 400 Hz, 75 us de-emphasis
Amplitude-frequency characteristic (stereo/mono operation)
n°2 Exciter Indium Series dual drive configuration
external CPU/control unit and load (4U)
From the frontal panel/from PC, a careful analysis of the functioning through detailed measurement of currents, voltages, temperatures and powers
environment)
< 0.05% with 100 KHz frequency deviation 30 Hz to 15 KHz
20 Hz to 23 KHz @ 53 KHz - detector RMS
> = 72 dB unweighted 400 Hz, 75 KHz frequency deviation, quasi-peak detector, 50 us de-emphasis
+/- 0.1 dB (without pre-emphasis) +/- 0.1 dB (with pre-emphasis) 20 Hz to 15 KHz, @ 400 Hz
single drive
configuration
38
Product description
Page 39
FM TRANSMITTER HIGH POWER | ET25000
Stereo Crosstalk (typical) 60 dB
Linear crosstalk >60 db 20 Hz to 15 KHz
Intermodulation distortion <0.05% Measured with two of tones 1 KHz & 1.3 KHz,
Class of emission F3
Stereo emission According to ITU-R reccomendation
EXCITER PERFORMANCE
PLL lock time <10 sec
Frequency deviation +/- 75 KHz 0.1 dB steps adjustable
Maximum frequency deviation +/- 150 KHz
Frequency stability 1 ppm
RF Frequency steps 10 KHz
Phase Response +/- 0.1 degree from linear phase;
INSTALLATION REQUIREMENTS
Power supply 380 V or 400 V, Threephase + neutral wire 50-60 Hz*
Power consumption 37 KW
Current consumption @230VAC/Threephase 92 A
Overall efficiency (typical from - 3 dB to Pman)
Power factor >0.95
Current consumption @380VAC/Threephase 53 A
ENVIRONMENT
Temperature range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating) 95% @ 40 °C, 104 °F
Humidity range (non operating) 90% @ 55 °C, 131 °F
Altitude range (operating) <3000 meters / <9840 Feet
Altitude range (non operating) <15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control Yes
Remote Control at clean contacts Yes
SNMP option Yes (external)
@ 400 Hz to 10 KHz
ratio 1:1 at 100% modulation
450 (pilot tone)
20 KHz to 100 KHz
210 V, Threephase (WYE without neutral)*
* to be specified when placing the order
68%
Product description
39
Page 40
Datasheet
FM TRANSMITTER HIGH POWER | ET20000
FM TRANSMITTER HIGH POWER | ET20000
COMPOSITION
Exciter (Indium series) n°1 Exciter Indium Series
Amplifier n°4 Amplifier E5000 Indium Series
Combiner n°1 4-way combiner IN 5000 - OUT 20000 with
Dummy load n°1 dummy load (4U)
Control unit n° 1 control unit (4U). From the frontal panel/
RF output connector 3+1/8”
Circuit breaker box 6U (on front or rear panel on demand)
GENERAL DATA
Output nominal maximum power 20000 W
Output power range 1500 ÷ 20000 W
Operating band 87.5 ÷ 108 MHz
Dimensions: Rack units min. 32U
Dimensions: W - H - D 56.5 - 192.5 - 107.8 cm (with fan)
Weight 370 kg
RF power stage technology ICEFET & ECOSAVING
Automatic power RF control Stabilized output power value on the set value
Overall output power RF stability +/- 0.1 dB
Cooling system Forced air-cooling
Air outlet On the top. Cooling flow 4000 m3/h (depending on
RS232/RS485 Yes. Connector DB9 female
Points of measure RF Sample - MPX Monitor
AUDIO PERFORMANCE
MPX input level +15/-10 dBu for 75 KHz standard deviation
MPX level adjustment Soft adjust 0.1 dB steps from front panel
MPX input impedance 5 KΩ selectable
L/R input level +15/-10 dBu for 75 KHz standard deviation
L/R level adjustment Soft adjust 0.1 dBu steps from front panel
L/R Input Impedance Selectable 10 K - 600 Ω, balanced
AES/EBU input resolution 24 bits
AES/EBU input sample rate 32,44.1,48,96 KHz Automatically selected
AES/EBU input level -20 dBFS - 0 dBFS
AES/EBU input impedance 110 Ω balanced
AES/EBU-Analog input automatic changeover Yes
PILOT Amplitude adjustment Soft adjust 0.05% steps from front panel
PILOT Phase adjustment Soft adjust 0.01 degree steps from front panel
PILOT tone frequency 19 KHz
PILOT tone deviation Soft adjust +/- 7.5 KHz
PILOT tone frequency stability +/- 1 Hz
THD+N (stereo/mono operation) < 0.05% with 75 KHz frequency deviation
Pre-emphasis 0/25/50/75 microseconds, selectable
Pre-emphasis tolerance +/- 0.1 dB
FM S/N (MPX operation) 82 dB
FM S/N CCIR (stereo/mono operation) > = 72 dB weighted
Asynchronous AM S/N unweighted > = 55 dB a 400 Hz, 75 us de-emphasis
Synchronous AM S/N > = 50 dB a 400 Hz, 75 us de-emphasis
Amplitude-frequency characteristic (stereo/mono operation)
n°2 Exciter Indium Series dual drive configuration
external CPU/control unit and load (4U)
from PC, a careful analysis of the functioning through detailed measurement of currents, voltages, temperatures and powers
environment)
< 0.05% with 100 KHz frequency deviation 30 Hz to 15 KHz
20 Hz to 23 KHz @ 53 KHz - detector RMS
> = 72 dB unweighted 400 Hz, 75 KHz frequency deviation, quasi-peak detector, 50 us de-emphasis
+/- 0.1 dB (without pre-emphasis) +/- 0.1 dB (with pre-emphasis) 20 Hz to 15 KHz, @ 400 Hz
single drive
configuration
40
Product description
Page 41
FM TRANSMITTER HIGH POWER | ET20000
Stereo Crosstalk (typical) 60 dB
Linear crosstalk >60 db 20 Hz to 15 KHz
Intermodulation distortion <0.05% Measured with two of tones 1 KHz & 1.3 KHz,
Class of emission F3
Stereo emission According to ITU-R reccomendation
EXCITER PERFORMANCE
PLL lock time <10 sec
Frequency deviation +/- 75 KHz 0.1 dB steps adjustable
Maximum frequency deviation +/- 150 KHz
Frequency stability 1 ppm
RF Frequency steps 10 KHz
Phase Response +/- 0.1 degree from linear phase;
INSTALLATION REQUIREMENTS
Power supply 380 V or 400 V, Threephase + neutral wire 50-60 Hz*
Power consumption 29 KW
Current consumption @230VAC/Threephase 73 A
Overall efficiency (typical from - 3 dB to Pman)
Power factor >0.95
Current consumption @380VAC/Threephase 43 A
ENVIRONMENT
Temperature range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating) 95% @ 40 °C, 104 °F
Humidity range (non operating) 90% @ 55 °C, 131 °F
Altitude range (operating) <3000 meters / <9840 Feet
Altitude range (non operating) <15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control Yes
Remote Control at clean contacts Yes
SNMP option Yes (external)
@ 400 Hz to 10 KHz
ratio 1:1 at 100% modulation
450 (pilot tone)
20 KHz to 100 KHz
210 V, Threephase (WYE without neutral)*
* to be specified when placing the order
68%
Product description
41
Page 42
Datasheet
FM TRANSMITTER HIGH POWER | ET15000
FM TRANSMITTER HIGH POWER | ET15000
COMPOSITION
Exciter (Indium series) n°1 Exciter Indium Series
Amplifier n°3 Amplifier E5000 Indium Series
Combiner/Control unit n°1 3-Way Combiner IN 5000 - OUT 15000 with an
RF output connector 3+1/8”
Circuit breaker box 4U (on front or rear panel on demand)
GENERAL DATA
Output nominal maximum power 15000 W
Output power range 1500 ÷ 15000 W
Operating band 87.5 ÷ 108 MHz
Dimensions: Rack units min. 32U
Dimensions: W - H - D 56.5 - 160.3 - 107.8 cm
Weight 320 kg
RF power stage technology ICEFET & ECOSAVING
Automatic power RF control Stabilized output power value on the set value
Overall output power RF stability +/- 0.1 dB
Cooling system Forced air-cooling
Air outlet On the top. Cooling flow 3250 /4500 m3/h
RS232/RS485 Yes. Connector DB9 female
Points of measure RF Sample - MPX Monitor
AUDIO PERFORMANCE
MPX input level +15/-10 dBu for 75 KHz standard deviation
MPX level adjustment Soft adjust 0.1 dB steps from front panel
MPX input impedance 5 KΩ selectable
L/R input level +15/-10 dBu for 75 KHz standard deviation
L/R level adjustment Soft adjust 0.1 dBu steps from front panel
L/R Input Impedance Selectable 10 K - 600 Ω, balanced
AES/EBU input resolution 24 bits
AES/EBU input sample rate 32,44.1,48,96 KHz Automatically selected
AES/EBU input level -20 dBFS - 0 dBFS
AES/EBU input impedance 110 Ω balanced
AES/EBU-Analog input automatic changeover Yes
PILOT Amplitude adjustment Soft adjust 0.05% steps from front panel
PILOT Phase adjustment Soft adjust 0.01 degree steps from front panel
PILOT tone frequency 19 KHz
PILOT tone deviation Soft adjust +/- 7.5 KHz
PILOT tone frequency stability +/- 1 Hz
THD+N (stereo/mono operation) < 0.05% with 75 KHz frequency deviation
Pre-emphasis 0/25/50/75 microseconds, selectable
Pre-emphasis tolerance +/- 0.1 dB
FM S/N (MPX operation) 82 dB
FM S/N CCIR (stereo/mono operation) > = 72 dB weighted
Asynchronous AM S/N unweighted > = 55 dB a 400 Hz, 75 us de-emphasis
Synchronous AM S/N > = 50 dB a 400 Hz, 75 us de-emphasis
Amplitude-frequency characteristic (stereo/mono operation)
Stereo Crosstalk (typical) 60 dB
Linear crosstalk >60 db 20 Hz to 15 KHz
Intermodulation distortion <0.05% Measured with two of tones 1 KHz & 1.3 KHz,
n°2 Exciter Indium Series dual drive configuration
internal load composed by 3 group of 6 resistance of 800 W 50 Ω
(depending on environment)
< 0.05% with 100 KHz frequency deviation 30 Hz to 15 KHz
20 Hz to 23 KHz @ 53 KHz - detector RMS
> = 72 dB unweighted 400 Hz, 75 kHz frequency deviation, quasi-peak detector, 50 us de-emphasis
+/- 0.1 dB (without pre-emphasis) +/- 0.1 dB (with pre-emphasis) 20 Hz to 15 KHz, @ 400 Hz
@ 400 Hz to 10 KHz
ratio 1:1 at 100% modulation
single drive
configuration
42
Product description
Page 43
FM TRANSMITTER HIGH POWER | ET15000
Class of emission F3
Stereo emission According to ITU-R reccomendation
EXCITER PERFORMANCE
PLL lock time <10 sec
Frequency deviation +/- 75 KHz 0.1 dB steps adjustable
Maximum frequency deviation +/- 150 KHz
Frequency stability 1 ppm
RF Frequency steps 10 KHz
Phase Response +/- 0.1 degree from linear phase;
INSTALLATION REQUIREMENTS
Power supply 380 V or 400 V, Threephase + neutral wire 50-60 Hz*
Power consumption 22 KW
Current consumption @230VAC/Threephase 63 A
Overall efficiency (typical from - 3 dB to Pman)
Power factor >0.95
Current consumption @380VAC/Threephase 36 A
ENVIRONMENT
Temperature range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating) 95% @ 40 °C, 104 °F
Humidity range (non operating) 90% @ 55 °C, 131 °F
Altitude range (operating) <3000 meters / <9840 Feet
Altitude range (non operating) <15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control Yes
Remote Control at clean contacts Yes
SNMP option Yes (external)
450 (pilot tone)
20 KHz to 100 KHz
210 V, Threephase (WYE without neutral)*
* to be specified when placing the order
68%
Product description
43
Page 44
Datasheet
FM TRANSMITTER HIGH POWER | ET10000
FM TRANSMITTER HIGH POWER | ET10000
COMPOSITION
Exciter (Indium series) n°1 Exciter Indium Series
Amplifier n°2 Amplifier E5000 Indium Series
Combiner/Control unit n°1 2-way combiner IN 5000 - OUT 10000 with an
RF output connector 1+5/8”
Circuit breaker box 4U (on front or rear panel on demand)
GENERAL DATA
Output nominal maximum power 10000 W
Output power range 1500 ÷ 10000 W
Operating band 87.5 ÷ 108 MHz
Dimensions: Rack units min. 20U
Dimensions: W - H - D 56.5 - 105 - 107.8cm
Weight 270 kg
RF power stage technology ICEFET & ECOSAVING
Automatic power RF control Stabilized output power value on the set value
Overall output power RF stability +/- 0.1 dB
Cooling system Forced air-cooling
Air outlet On the top or on the rear. Cooling flow 2200 /2400
RS232/RS485 Yes. Connector DB9 Female
Points of measure RF Sample - MPX Monitor
AUDIO PERFORMANCE
MPX input level +15/-10 dBu for 75 KHz standard deviation
MPX level adjustment Soft adjust 0.1 dB steps from front panel
MPX input impedance 5 KΩ selectable
L/R input level +15/-10 dBu for 75 KHz standard deviation
L/R level adjustment Soft adjust 0.1 dBu steps from front panel
L/R Input Impedance Selectable 10 K - 600 Ω, balanced
AES/EBU input resolution 24 bits
AES/EBU input sample rate 32,44.1,48,96 KHz Automatically selected
AES/EBU input level -20 dBFS - 0 dBFS
AES/EBU input impedance 110 Ω balanced
AES/EBU-Analog input automatic changeover Yes
PILOT Amplitude adjustment Soft adjust 0.05% steps from front panel
PILOT Phase adjustment Soft adjust 0.01 degree steps from front panel
PILOT tone frequency 19 KHz
PILOT tone deviation Soft adjust +/- 7.5 KHz
PILOT tone frequency stability +/- 1 Hz
THD+N (stereo/mono operation) < 0.05% with 75 KHz frequency deviation
Pre-emphasis 0/25/50/75 microseconds, selectable
Pre-emphasis tolerance +/- 0.1 dB
FM S/N (MPX operation) 82 dB
FM S/N CCIR (stereo/mono operation) > = 72 dB weighted
Asynchronous AM S/N unweighted > = 55 dB a 400 Hz, 75 us de-emphasis
Synchronous AM S/N > = 50 dB a 400 Hz, 75 us de-emphasis
Amplitude-frequency characteristic (stereo/mono operation)
Stereo Crosstalk (typical) 60 dB
Linear crosstalk >60 db 20 Hz to 15 KHz
Intermodulation distortion <0.05% Measured with two of tones 1 KHz & 1.3 KHz,
n°2 Exciter Indium Series dual drive configuration
internal load composed by 1 group of 6 resistance of 800 W 50 Ω
m3/h (depending on environment)
< 0.05% with 100 KHz frequency deviation 30 Hz to 15 KHz
20 Hz to 23 KHz @ 53 KHz - detector RMS
> = 72 dB unweighted 400 Hz, 75 KHz frequency deviation, quasi-peak detector, 50 us de-emphasis
+/- 0.1 dB (without pre-emphasis) +/- 0.1 dB (with pre-emphasis) 20 Hz to 15 KHz, @ 400 Hz
@ 400 Hz to 10 KHz
ratio 1:1 at 100% modulation
single drive
configuration
44
Product description
Page 45
FM TRANSMITTER HIGH POWER | ET10000
Class of emission F3
Stereo emission According to ITU-R reccomendation
EXCITER PERFORMANCE
PLL lock time <10 sec
Frequency deviation +/- 75 KHz 0.1 dB steps adjustable
Maximum frequency deviation +/- 150 KHz
Frequency stability 1 ppm
RF Frequency steps 10 KHz
Phase Response +/- 0.1 degree from linear phase;
INSTALLATION REQUIREMENTS
Power supply 380 V or 400 V, Threephase + neutral wire 50-60 Hz*
Power consumption 15 KW
Current consumption @230VAC/Threephase 42 A
Overall efficiency (typical from - 3 dB to Pman)
Power factor >0.95
Current consumption @380VAC/Threephase 24 A
ENVIRONMENT
Temperature range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating) 95% @ 40 °C, 104 °F
Humidity range (non operating) 90% @ 55 °C, 131 °F
Altitude range (operating) <3000 meters / <9840 Feet
Altitude range (non operating) <15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control Yes
Remote Control at clean contacts Yes
SNMP option Yes (external)
450 (pilot tone)
20 KHz to 100 KHz
210 V, Threephase (WYE without neutral)*
* to be specified when placing the order
68%
Product description
45
Page 46
Datasheet
FM AMPLIFIER MEDIUM POWER | E5000
FM AMPLIFIER MEDIUM POWER | E5000
GENERAL DATA
Output Nominal Power 5000 W adjustable
Operating band 87.5 ÷ 108 MHz
RS232/RS485 Yes. Connector DB9 female
Points of measure RF Sample - MPX Monitor
Displayed Parameters More than 50 parameters displayed on a wide
Adjustments From the frontal panel through OLED/from PC
Number of L-DMOS in amplifier stage 7
RF power stage technology ICEFET & ECOSAVING
Dimensions: Rack units 4U
Dimensions: W - H - D 48.5 - 17.6 - 70 cm
Weight 35 Kg
Number of power supplies 3
Number of cooling fans 6
CONNECTORS
RF Output connector 7/8
RF Input connector N
RF PERFORMANCE
Output impedance 50 Ω
Automatic power RF control Stabilizes the output power value on the
Overall output power RF stability +/- 0,1 dB
VSWR 2:1 at full power. Automatic power
Harmonics < -75 dBc
Out of band emission (spurious) < -80 dBc
AUDIO AND EXCITER PERFORMANCE
Driving power 2W *
INSTALLATION REQUIREMENTS
Power supply 230/400 Threephase-Singlephase
Power consumption (typical) 7.1 KW
graphic 0-LED screen
set value
reduction beyond 1.7:1. Transmitter is protected fro open and short circuit.
Version 50-60 Hz VAC
46
* Elenos suggests to drive this amplifier with ETG20 Elenos Indium Series
Product description
Page 47
FM AMPLIFIER MEDIUM POWER | E5000
Overall efficiency (typical from -3dB to Pnom) > = 70%
Power factor > 0.95
Current Consumption @ 230VAC/single phase 31 Amp
Magneto-thermic capacity @ 230VAC/single phase 45 Amp
Conductor size @ 230VAC/single phase 10 sqrt.mm
Conductor size @ 230VAC/single phase 7 AWG
Current Consumption @ 230VAC/three phase 18.5 Amp
Magneto-thermic capacity @ 230VAC/three phase 32 Amp
Conductor size @ 230VAC/three phase 6 sqrt.mm
Conductor size @ 230VAC/three phase 9 AWG
Current Consumption @ 400VAC/three phase 10.5 Amp
Magneto-thermic capacity @ 400VAC/three phase 20 Amp
Conductor size @ 400VAC/three phase 4 sqrt.mm
Conductor size @ 400VAC/three phase 11 AWG
COOLING/NOISE/DATA
Cooling system Forced air-cooling . From 600 to 1200 m3/h
Air temperature increase 17 °C
Acoustic noise < 65 phon
ENVIRONMENT
Temperature range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating) 95% @ 40 °C, 104 °F
Humidity range (non operating) 90% @ 55 °C, 131 °F
Altitude range (operating) <3000 meters / <9840 Feet
Altitude range (non operating) <15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control Yes
Remote control, dry contacts Yes
SNMP option Yes (external)
@ transmitter room, 2 m distance of the front of transmitter
Product description
47
Page 48
Datasheet
FM AMPLIFIER MEDIUM POWER | E3500
FM AMPLIFIER MEDIUM POWER | E3500
GENERAL DATA
Output Nominal Power 3500 W adjustable
Operating band 87.5 ÷ 108 MHz
RS232/RS485 Yes. Connector DB9 femate
Points of measure RF Sample - MPX Monitor
Displayed Parameters More than 50 parameters displayed on a wide
Adjustments From the frontal panel through OLED/from PC
Number of L-DMOS in amplifier stage 5
RF power stage technology ICEFET & ECOSAVING
Dimensions: Rack units 4U
Dimensions: W - H - D 48.5 - 17.6 - 70 cm
Weight 35 Kg
Number of power supplies 3
Number of cooling fans 6
CONNECTORS
RF Output connector 7/8”
RF Intput connector N
RF PERFORMANCE
Output impedance 50 Ω
Automatic power RF control Stabilizes the output power value on the
Overall output power RF stability +/- 0,1 dB
VSWR 2:1 at full power. Automatic power
Harmonics < -75 dBc
Out of band emission (spurious) < -80 dBc
AUDIO AND EXCITER PERFORMANCE
Driving power 2W *
INSTALLATION REQUIREMENTS
Power supply 230/400 Threephase-Singlephase
Power consumption (typical) 4.9 KW
graphic OLED
set value
reduction beyond 1.7:1. Transmitter is protected fro open and short circuit.
Version 50-60 Hz VAC
48
* Elenos suggests to drive this amplifier with ETG20 Elenos Indium Series
Product description
Page 49
FM AMPLIFIER MEDIUM POWER | E3500
Overall efficiency (typical from -3 dB to Pnom) > = 70%
Power factor > 0.95
Current Consumption @ 230VAC/single phase 21.3 Amp
Magneto-thermic capacity @ 230VAC/single phase 32 Amp
Conductor size @ 230VAC/single phase 10 sqrt.mm
Conductor size @ 230VAC/single phase 7 AWG
Current Consumption @ 230VAC/three phase 12.5 Amp
Magneto-thermic capacity @ 230VAC/three phase 20 Amp
Conductor size @ 230VAC/three phase 6 sqrt.mm
Conductor size @ 230VAC/three phase 9 AWG
Current Consumption @ 400VAC/three phase 7.1 Amp
Magneto-thermic capacity @ 400VAC/three phase 16 Amp
Conductor size @ 400VAC/three phase 4 sqrt.mm
Conductor size @ 400VAC/three phase 11 AWG
COOLING/NOISE/DATA
Cooling system Forced air-cooling . From 600 to 1200 m3/h
Air temperature increase 17 °C
Acoustic noise < 65 phon
ENVIRONMENT
Temperature range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating) 95% @ 40 °C, 104 °F
Humidity range (non operating) 90% @ 55 °C, 131 °F
Altitude range (operating) <3000 meters / <9840 Feet
Altitude range (non operating) <15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control Yes
Remote control, dry contacts Yes
SNMP option Yes (external)
@ transmitter room, 2 m distance of the front of transmitter
Product description
49
Page 50
Datasheet
FM AMPLIFIER MEDIUM POWER | E2500
FM AMPLIFIER MEDIUM POWER | E2500
GENERAL DATA
Output Nominal Power 2500 W adjustable
Operating band 87.5 ÷ 108 MHz
RS232/RS485 Yes. Connector DB9 female
Points of measure RF Sample - MPX Monitor
Displayed Parameters More than 50 parameters displayed on a wide
Adjustments From the frontal panel through OLED/from PC
Number of L-DMOS in amplifier stage 4
RF power stage technology ICEFET & ECOSAVING
Dimensions: Rack units 4U
Dimensions: W - H - D 48.5 - 17.6 - 70 cm
Weight 35 Kg
Number of power supplies 3
Number of cooling fans 6
RF Output connector 7/8”
RF Input connector N
RF PERFORMANCE
Output impedance 50 Ω
Automatic power RF control Stabilizes the output power value on the
Overall output power RF stability +/- 0,1 dB
VSWR 2:1 at full power. Automatic power
Harmonics < -75 dBc
Out of band emission (spurious) < -80 dBc
AUDIO AND EXCITER PERFORMANCE
Driving power 2W *
INSTALLATION REQUIREMENTS
Power supply 230/400 Threephase-Singlephase
Power consumption (typical) 3.5 KW
graphic OLED
set value
reduction beyond 1.7:1. Transmitter is protected for open and short circuit.
Version 50-60 Hz VAC
50
* Elenos suggests to drive this amplifier with ETG20 Elenos Indium Series
Product description
Page 51
FM AMPLIFIER MEDIUM POWER | E2500
Overall efficiency (typical from -3 dB to Pnom) > = 70%
Power factor > 0.95
Current Consumption @ 230VAC/single phase 15 Amp
Magneto-thermic capacity @ 230VAC/single phase 32 Amp
Conductor size @ 230VAC/single phase 6 sqrt.mm
Conductor size @ 230VAC/single phase 9 AWG
Current Consumption @ 230VAC/three phase 9 Amp
Magneto-thermic capacity @ 230VAC/three phase 20 Amp
Conductor size @ 230VAC/three phase 4 sqrt.mm
Conductor size @ 230VAC/three phase 11 AWG
Current Consumption @ 400VAC/three phase 5 Amp
Magneto-thermic capacity @ 400VAC/three phase 10 Amp
Conductor size @ 400VAC/three phase 2.5 sqrt.mm
Conductor size @ 400VAC/three phase 13 AWG
COOLING/NOISE/DATA
Cooling system Forced air-cooling . From 600 to 1200 m3/h
Air temperature increase 17 °C
Acoustic noise < 65 phon
ENVIRONMENT
Temperature range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating) 95% @ 40 °C, 104 °F
Humidity range (non operating) 90% @ 55 °C, 131 °F
Altitude range (operating) <3000 meters / <9840 Feet
Altitude range (non operating) <15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote control Yes
Remote control, dry contacts Yes
SNMP option Yes (external)
@ transmitter room, 2 m distance of the front of transmitter
Product description
51
Page 52

2.9 Protections

The equipment has an integrated protection system both for the hardware and the software.

2.9.1 Software protections

2.9.1.1 IPF (Intelligent Proportional Foldback)
Mechanism which is activated on the control unit and works on each individual machi­ne. The IPF is an intelligent system which reduces the equipment’s output power in the event of strong load mismatch, thus preventing the machine from turning off. The activation of this feature is shown on the display as alarm “026” for modulators and “030” for amplifiers.
2.9.1.2 IPC (Intelligent Power Control)
It is provided on the amplifiers in the system. When the equipment is working properly, the IPC keeps the amplifier output power constant (and subsequently, the transmitter output power) within +/-1% of the target set, irre­spective of mains voltage, temperature and load variations. The IPC also allows the RF section efficiency to be optimized by making the MOSFETs constantly work at maximum efficiency, thus minimizing overall electrical consumption.
2.9.1.3 Safety Management (“Lifextender” option) ® The Safety Management consists of algorithms which perform a real-time analysis of the transmitter’s operating status and operates in order to maintain the output power set, according to the type and severity of any errors (internal or environmental) that may occur. The Safety Management can control an output power reduction proportional to the severity of the error that arises. The algorithms act at different levels and in various sections of the equipment: Thermal Management on the RF unit, Thermal Management on Dummy Load, Current Manage­ment on the power supply unit, Thermal Management on the power supply unit, Fault management on the RF unit, Fault Management on the power supply unit, Cooling Management on the fan unit.
Thermal Management on the RF unit (Lifextender) ® It is provided on amplifiers and exciters. If the temperature measured in the vicinity of the MOSFETs exceeds 72 °C, a first level of derating intervenes slightly in order to reduce the temperature through an output power reduction. The power reduction is the lowest possible that allows a thermal balance to be reached at a temperature of less than 72 °C. The output power reduction never exceeds 40% with this first derating. In other words, the output power is always 60% higher than that set by the user, and the “- 3 dB” war­ning with corresponding alarm does not intervene. This first derating level is effective in virtually all cases. The activation of this feature is shown on the display as alarm “010”. Should the first level derating be insufficient (extremely rare), a second level inter­venes, further reducing the power, thus obtaining a thermal balance status which is compatible with the safe operation of the equipment even if it is below – 3 dB (with subsequent “005” alarm).
52 Product description
Page 53
If the second derating is ineffective (in case of external conditions which are not com­patible with the safe operation of the equipment) the equipment switches off. In this case, if the temperature decreases, the power is raised again proportionally. If it decreases by 20°C the derating feature is exited and full power is restored. After 3 failed attempts, the control logic locks the equipment (alarm “011”).
Thermal Management on Dummy Load If the temperature measured in the vicinity of the Dummy Load exceeds 90°C, a first le­vel of derating intervenes slightly in order to reduce the temperature through an output power reduction. The power reduction is the lowest possible that allows a thermal balance to be reached at a temperature of less than 90 °C. The output power reduction never exceeds 40% with this first derating. In other words. the output power is always 60% higher than that set by the user, and the “- 3 dB” signaling does not intervene. This first derating level is effective in virtually all cases. If the first level derating is insufficient (extremely rare), a second level intervenes, further reducing the power, thus obtaining a thermal balance status which is compatible with the safe operation of the equipment even if it is below - 3dB (with subsequent corresponding alarm). If the second derating is ineffective (in case of external conditions which are not com­patible with the safe operation of the equipment) the equipment switches off. Thermal derating has a 10°C hysteresis before it attempts to restore the normal opera­ting conditions of the equipment. After 3 failed attempts, the control logic locks the equipment.
Current management on the power supply unit (Lifextender) ® It is provided on amplifiers and exciters. This is activated when the maximum current for continuous operation of the power supply is exceeded. This value is set below the deliverable current limit and constitutes the threshold which can be exceeded only for short periods (maximum 1 minute at a time). If this situa­tion arises, the “PSU current derating” function is activated (alarm “013” and/or “014” relative to amplifiers and modulators) and the ALC management algorithm, envisaged for normal operating conditions, is replaced by another one wherein the VDS control and Bias is determined by the power set and, with even higher priority, by the current delivered by the power supply. The current derating condition is deactivated when the power delivered returns to the value set by the user and if the maximum current delivered by the power supply is less than or equal to the maximum value allowed for continuous operation.
Thermal management on the power supply unit (Lifextender) ® It is provided on amplifiers and exciters. The power supply management algorithm according to the temperature is the same as that on the RF unit, and it is logically connected in “OR” to the latter. The first Derating level (acting directly on the output power) is activated when the po­wer supply temperature exceeds 75°C, while the second level is activated - if the first is ineffective - if the temperature does not stabilize below this value. In the latter case, the output power is brought below – 3 dB with the same procedure as that described for the RF section. The activation of this feature is shown on the display as alarm “015” and /or”016” rela­tive to amplifiers and modulators.
53Product description
Page 54
Fault management on RF modules (Lifextender) ® It is provided on amplifiers and exciters. This manages the maximum deliverable power according to the number of RF amplifier modules considered to be operating correctly. If one or more MOSFETs are considered faulty (this happens when the absorbed current is 10% below the average value), the RF output power is reduced to the expected value when a fault occurs. The failure case report and the relative maximum power achievable is described in a complex table obtained through tests. It is designed to stop failure propagation and prevent excessive stress on the MOSFETs that still work due to the ALC feature (which would require them to deliver all the missing output power). In order to prevent a ridiculously high number of alarm SMSs, no messages are sent during this phase: the alarm SMS, if validated, is only sent after the adaptation procedu­re of the output power according to the table parameters and only if the -3dB condition occurs on the output power. The activation of this feature is shown on the display as alarms “008” and “009” relati­ve to amplifiers and modulators.
Cooling Management on the fan unit (Lifextender) ® According to the actual cooling requirements, the rotation speed of the fans is adjusted from a minimum of 60% to a maximum of 120% approx. (these values may vary accor­ding to the models of fan used). The cooling requirement is estimated based on the accurate temperature measure­ments which are performed in correspondence with the RF MOSFETs and the power supply unit in the case of amplifiers and modulators and on the Dummy Load. The Cooling Management aims to extend the effective lifetime of the fans, minimize the quantity of dust that may be transported by the air flow and allow the safe opera­tion of the equipment also under extreme temperature conditions. Without the Lifextender the fans always work at 100%.

2.9.2 Hardware protections

The hardware protection system comprises:
• fast electronic and fuse protection of power supplies;
• fast electronic protection on the fan power supply;
• fast protection against excess reflected power (SWR/VSWR) following a strong load mismatch. This protection is activated when the reflected power value exceeds 10% of the forward power;
• protection against splitter and combiner overheating through fans with a thermo­stat;
• designed based on redundancy so as to eliminate the “SINGLE-POINT-FAILURE”, that is any points which alone define an OFF-AIR situation;
• construction of metal parts in stainless steel and aluminium, treatment of the elec­tronic boards with protective paint (tropicalization), closing off the most sensitive components to air flow with special shields in order to provide protection against corrosion.
54 Product description
Page 55

2.10 Options

The equipment in this series can be purchased with different options included:
Version with modulating
signal input
MPX Inputs:
• MPX
• Aux 1 Outputs:
• MPX monitor
STEREO Inputs:
• Left channel
• Right channel
• MPX
• Aux1
• Aux 2 Outputs:
• MPX monitor/19 kHz
AES/EBU Inputs:
• Left channel
• Right channel
• MPX
• Aux 1
• Aux 2
• AES-EBU Output:
• MPX monitor/19 kHz
Purchase information: please request the following codes
00T-6LLVVX-10 (ET30000-5 D.D.) 00T-6LLV0X-10 (ET30000-5 S.D.) 00T-5LLVVX-10 (ET25000-5 D.D.) 00T-5LLV0X-10 (ET25000-5 S.D.) 00T-4LLVVX-10 (ET20000-5 D.D.) 00T-4LLV0X-10 (ET20000-5 S.D.) 00T-3LLVVX-10 (ET15000-5 D.D.) 00T-3LLV0X-10 (ET15000-5 S.D.) 00T-2LLVVX-10 (ET10000-5 D.D.) 00T-2LLV0X-10 (ET10000-5 S.D.) 00T-XLLAAX-10 (ET5000 D.D.) 00T-XLLA0X-10 (ET5000 S.D.) 00T-XILAAX-10 (ET3500 D.D.) 00T-XILA0X-10 (ET3500 S.D.) 00T-XHLAAX-10 (ET3500 D.D.) 00T-XHLA0X-10 (ET3500 S.D.)
00T-6LLVVA-10 (ET30000-5 D.D.) 00T-6LLV0A-10 (ET30000-5 S.D.) 00T-5LLVVA-10 (ET25000-5 D.D.) 00T-5LLV0A-10 (ET25000-5 S.D.) 00T-4LLVVA-10 (ET20000-5 D.D.) 00T-4LLV0A-10 (ET20000-5 S.D.) 00T-3LLVVA-10 (ET15000-5 D.D.) 00T-3LLV0A-10 (ET15000-5 S.D.) 00T-2LLVVA-10 (ET10000-5 D.D.) 00T-2LLV0A-10 (ET10000-5 S.D.) 00T-XLLAAA-10 (ET5000 D.D.) 00T-XLLA0A-10 (ET5000 S.D.) 00T-XILAAA-10 (ET3500 D.D.) 00T-XILA0A-10 (ET3500 S.D.) 00T-XHLAAA-10 (ET3500 D.D.) 00T-XHLA0A-10 (ET3500 S.D.)
00T-6LLVVD-10 (ET30000-5 D.D.) 00T-6LLV0D-10 (ET30000-5 S.D.) 00T-5LLVVD-10 (ET25000-5 D.D.) 00T-5LLV0D-10 (ET25000-5 S.D.) 00T-4LLVVD-10 (ET20000-5 D.D.) 00T-4LLV0D-10 (ET20000-5 S.D.) 00T-3LLVVD-10 (ET15000-5 D.D.) 00T-3LLV0D-10 (ET15000-5 S.D.) 00T-2LLVVD-10 (ET10000-5 D.D.) 00T-2LLV0D-10 (ET10000-5 S.D.) 00T-XLLAAD-10 (ET5000 D.D.) 00T-XLLA0D-10 (ET5000 S.D.) 00T-XILAAD-10 (ET3500 D.D.) 00T-XILA0D-10 (ET3500 S.D.) 00T-XHLAAD-10 (ET3500 D.D.) 00T-XHLA0D-10 (ET3500 S.D.)
The rack also may include:
• remote control unit (Echos3 or E.Box);
• surge arresters drawer;
• circuit breaker box positioned front or back (according to the type of model);
• cooling fan;
• technical panel and output connector positioned on the roof or rear (according to the type of model).
The LifExtender can be requested as an option using the previous codes. To be specified in the order.
55Product description
Page 56
56 Product description
Page 57

3 Use instructions

3.1 User interface

3.1.1 Control unit user interface

The controls and display views of the control unit (representing the combined system interface as a whole) are described below.
Please note that in order to have complete visibility of all the available interfaces, the equipment must be set to LOCAL mode and it must be accessed with the specific passwords. Specifically in REMOTE mode you lose visibility of the menus 485 SPEED SET, COM.ID LC/ RT DISP MODE, TEMPERATURE UNIT, MAX REFLECTED POWER SWR FOLDBACK SETTING, NO MAINS AARM SETTING, UPS SETTINGS, GSM/MODEM menu.
Turn the encoder to navigate through the menu items. To enter the desired item or to access a sub menu press the encoder while on the “>” icon. To exit an item press the encoder while on the “<” icon.
If you change the value of a parameter, to maintain it, before turn off the machi­ne wait at least 60seconds.
In the case of systems without control UNIT (ET5000, ET3500, ET2500) should be taken as reference the interfaces of the amplifier and the modulator.
Warning: the screen pictures shown below and the values attributed to the parameters are provided for illustrative purposes only. The parameters shown may vary slightly according to the equipment and setup type of the audio board.
Use instructions
57
Page 58
POWER SETTING
INPUT PASSWORD
PROFILE
MAIN ALARM
TEMPERATURES
MAIN VIEW
DUAL DRIVE
DUAL DRIVE DRIVE
DUAL DRIVE HANDLER
TEMPERATURES DL
485 SPEED SET
MENU SYSTEM
MENU GSM/PSTN
EVENTS LIST
EVENTS HISTORY
VOLTAGES
SYSTEM INFO
SYSTEM TIME
CLOCK PWR TARGET
COM.ID LC/RT DISP MODE
TEMPERATURE UNIT
NO MAINS ALARM SETTING
PASSWORD SETTING
PASSWORD RECOVERY
UPS SETTINGS
MENU UARTS
EXIT
UART0 INFO
UART1 INFO
UART2 INFO
EXIT
MAX REFLECTED POWER
SWR FOLDBACK SETTING
-3dB ALARM SETTING
STRING ID/PAGER ID
PHONE N.1..5
EXIT
GSM FIELD STRENGTH
FREQUENCY SETTING
58
Use instructions
Page 59
3.1.1.1 Power setting
Indication on the forward and reflected power. Setting the desired target power, activating the transmission and enabling the profile.
3.1.1.2 Frequency setting
Setting the desired frequency.
3.1.1.3 Input password
Some items are reserved and therefore can only be viewed and/or edited depending on the user authorisations. Here you can enter the access password.
3.1.1.4 Profile
Enabling the profile and displaying the power values of each profile.
3.1.1.5 Main alarm
Indication on the latest alarm occurred or on the correct operating condition. The forward power value is shown. Here the alarms can be reset.
Use instructions
59
Page 60
3.1.1.6 Temperatures
Indication of the dummy load temperature, environment temperature, reserve exciter load temperature, fan speed. The temperature indications depend on the presence of probes inside the equipment. Therefore, for certain types of equipment, some of these values may not be available.
3.1.1.7 Main view
Displaying the following parameters: forward power, reflected power, efficiency, current and voltage.
3.1.1.8 Events list
Alarm list. Those showing a letter “A” at the front are active. For further details, please see the “Alarms/events list” paragraph.
3.1.1.9 Events history
Indication of the date and time of each alarm.
60 Use instructions
Page 61
3.1.1.10 Dual drive
Setting the exchange between the exciters in manual/automatic mode, as well as the maximum number of times for the exchange. Indication of which exciter is on the antenna and which is on the load. By selecting “CHANGE” here, it is possible to force the exchange.
3.1.1.11 Dual drive drive
Setting the exchange between the exciters in manual/automatic mode, as well as the maximum number of times for the exchange. Indication as to whether the exciters are “On Air” or not, and in alarm or not.
3.1.1.12 Dual drive handler
Setting the exchange between the exciters in manual/automatic mode, viewing the relay position, assigning the exciters to the antenna or the load.
3.1.1.13 Temperatures DL
Indication of the maximum temperature detected on the dummy load, the envirnment temperature, the individual temperatures detected on each load module. The temperature indications depend on the presence of probes inside the equipment. Thus, on certain types of equipment some of these values may not be available.
61Use instructions
Page 62
3.1.1.14 485 speed set
Setting the front and rear serial port 485 speed.
3.1.1.15 Voltages
Displaying the voltage values.
3.1.1.16 System info
Indication of the software version, the protocol version and the equipment activity time.
3.1.1.17 System time
Setting the day of the week, the date and the time.
62 Use instructions
Page 63
3.1.1.18 Clock pwr target
As well as the standard power adjustment, it can also be set according to time slots in order to save energy. For the power delivered to be set according to individual time slots, the option which makes it fixed for 24 hours must be deactivated. To do so set “For All 24 Hours: FALSE”. The list of the time slots into which the whole day is divided is then displayed. Each time slot lasts one hour. Go to the time slot for which you want to change the power, press the encoder to make it editable, set the new target power by turning the encoder, then press again to con­firm.
3.1.1.19 Com. ID LC/RT disp. mode
Setting the addresses and activating the display so that the menus are also visible in REMOTE mode.
3.1.1.20 Temperature unit
Setting the temperature unit of measurement.
63Use instructions
Page 64
3.1.1.21 Max reflected power
The maximum reflected power permitted is 10% of the nominal power. Here it is possible to set a lower value when required by the user. Warning: in this case, correct operation of the foldback is not guaranteed.
3.1.1.22 SWR foldback setting
Foldback activation.
Algoritmo foldback
The Elenos devices feature two different and independent protections which are activa­ted when there is excess reflected power. The first is a hardware threshold which operates when the reflected power exceeds 10% of the maximum rated output power of the transmitter in a very short space of time. In these conditions the transmitter switches off. The second is a software protection, called “foldback algorithm”. It is activated when the reflected power increase is slower (for example, when there is snow or ice on the antenna). In these conditions, the transmitter gradually reduces its output power until the re­flected power threshold is exceeded, while the output power is gradually restored when the values go back to normal. If normal operating conditions continue for more than 60 seconds, the algorithm is inactive. The activation of this second protection is left to the user (from the SWR foldback set­ting screen).
3.1.1.23 No mains alarm setting
Setting the alarm, sent through an SMS, in the event of power failure for a set period of time.
64 Use instructions
Page 65
3.1.1.24 Password setting
There are two levels of user privilege: USER and SYSTEM, which are both initially pro­tected by the default password “0000”. In this screen it is possible to define customized passwords by the user with “SYSTEM” privileges.
Other parameters that can be set from this menu are the machine addresses (referen­ce for communication with it).
3.1.1.25 Password recovery
If you lose your password, please contact Elenos. Elenos must be given the “Unlock code” displayed on this screen. Elenos will provide a password valid for 24 hours to be entered on the same screen under the “Password Recovery” item. The user must later define new passwords through the “Password Setting” screen.
3.1.1.26 UPS settings
Setting the target power to be used when the machine is working with an uninterrupti­ble power source.
65Use instructions
Page 66
3.1.1.27 Uart 0,1,2 info
Control menu for checking the serials.
66 Use instructions
Page 67
3.1.1.28 GSM field strength
Indicating if the equipment is enabled to broadcast and receive SMSs, if it is in calling mode through the modem analog line. The GSM coverage field is shown. For further details, please see the “SMS list” paragraph.
3.1.1.29 -3dB alarm setting
Enabling the alarm -3dB to be sent by SMS. This indicates that 2/3 of the power set has been exceeded.
3.1.1.30 String ID/Pager ID
Defining the workstation name and the codes to be viewed in the message strings.
3.1.1.31 Phone N.1 .. 5
Various SIM cards can “communicate” with the equipment (based on the customer requirements). The telephone numbers in international format and authorizations can be set in these templates. The number can be globally enabled for SMS transmission and reception (en), be ena­bled to send commands (cm), be enabled to request and receive the machine status (st), be enabled to receive the echo any of commands sent by other numbers (gl) and be enabled to receive SMSs in text or digital format (PC.)
67Use instructions
Page 68
TX CONTROL PANEL
3.1.2 Amplifier user interface
SYSTEM CONFIG
GSM AND MODEM SERVICE
SYSTEM CONFIG 1
PHONE N.1 TO 4/PHONE N.5 TO 8
COMMUNICATION PORT SET
EXIT
VIEW TX PARAMETERS 1
VIEW TX PARAMETERS 2
ALARMS LIST
EVENTS HISTORY
PASSWORD
PASSWORD SETTING
SYSTEM INFO
SYSTEM TIME
CLOCK PWR TARGET 1 OF 2
CLOCK PWR TARGET 2 OF 2
ENABLE ALARMS SMS
DISPLAY ALARMS BIT
UART 0 INFO/UART 1 INFO
68
PASSWORD RECOVERY
MENU SYSTEM
MENU DIAGNOSTIC
Use instructions
USER ALARMS DATA
USER ALARMS TIMERS
LIFEXTENDER
MENU GSM/MODEM
EXIT
SMS DIAGNOSTIC
EXIT
Page 69
3.1.2.1 TX control panel
Main screen which appears automatically when turning on in LOCAL mode. It is used to set and check the main operating parameters (target power, forward power, reflected power, interlock led, reduction power led).
3.1.2.2 View TX parameters 1
Display only screen. The parameters which can be monitored are as follows: number of active profile, efficiency, transmitter working hours, fan working hours, direct power target, effective direct power value, reflected power, driving power, current, voltage, maximum tempe­rature and fan speed.
3.1.2.3 View TX parameters 2
Display only screen. The parameters which can be monitored are as follows: current and temperature of the amplifier modules, current, voltage and temperature of the power supplies, voltages of auxiliary power supply, sum of the power supply currents, sum of the module currents, voltage, ambient temperature and efficiency.
69Use instructions
Page 70
3.1.2.4 Alarms list
Display only screen. It is possible to monitor the list of most recent alarms. The alarms indicated by the letter “A” are still active. In order to understand the meaning of the alarms, please refer to paragraph “Alarms/ events list”.
3.1.2.5 Events history
Display only screen. The log of all the events/alarms occurred (up to 99) can be monitored. These are indi­cated by code, description, date and time.
3.1.2.6 Password
The equipment is delivered with the default password “0000” that can be customized by the user (for more details, please see paragraph “Password Setting”). In this screen the access password must be entered.
3.1.2.7 Password setting
There are two levels of user privilege: USER and SYSTEM, which are both initially pro­tected by the default password “0000”. In this screen it is possible to define customized passwords by the user with “SYSTEM” privileges.
70 Use instructions
Page 71
Other parameters that can be set from this menu are the machine addresses (reference for communication with it).
3.1.2.8 Password recovery
If you lose your password, please contact Elenos. Elenos must be given the “Unlock code” in this screen. Elenos will provide a password valid for 24 hours to be entered on the same screen under the “Password Recovery” item. The user must later define new passwords through the “Password Setting” screen.
3.1.2.9 System config
Setting and display screen. The following parameters can be set by the user: temperature measurement unit (Temp. U.), remote display operating mode (Show D.), equipment protection in case of oscillations (PwOscChk), power target when working with a UPS (UPS T), minimum number of sensors on which to perform the check on the functionality resulting in sen­ding alarm (Min T.Sen), power reading calibration (FwdPwrCal), SWR foldback, polariza­tion threshold (IPA Bias Tres.), reflected power nominal threshold (Refl.Pwr T.N., when active it is 10% of direct power), reflected power customized threshold (Refl.Pwr T.Lev., when the nominal threshold is inactive, it is possible to set values below10%), final polarization (PAbias), maximum settable power full scale (Max Target Pwr).
Power oscillation algorithm
In Elenos devices, if there is a power variation of “n” W (“n” being defined in specific tables) at least 3 consecutive times within 15 seconds, the “035” alarm is activated and the three block out mechanism is triggered (if this mechanism fails, the “003” alarm is then activated).
71Use instructions
Page 72
3.1.2.10 System config 1
Setting and display screen. The alarm signal, caused by wrong output power, snaps by default at -3dB of target power and disappears when you reach the 2/3 of that. The “Min Level Fwr Pwr Fault” additional parameter, set here, acts in an AND condition with the standard algorithm: so, the alarm will snap when there is the first between the two conditions “-3dB” and “Min Level Fwr Pwr Fault“, while will disappear when the highest value between ”2/3 Ptarget“ and ”Min Level Fwr Pwr Fault+typical step related to apparatus“ occurs. For stand-alone devices meant to set Min Level Fwr Pwr Fault to a value greater than­3dB, while using lower values may have meaning in N+1 systems. By default Min Level Fwr Pwr Fault is set to the minimum value of power.
3.1.2.11 Communication port set
Setting and display screen. The parameters which can be set by the user are the speed and the front and rear 485 door addresses.
3.1.2.12 System info
Setting and display screen. The equipment software version, the protocol version, the equipment activity time and the fan operating time are indicated. It is possible to reset the latter by clicking “R”.
72 Use instructions
Page 73
3.1.2.13 System time
Setting and display screen. The following parameters can be set by the user: the day of the week, date and time.
3.1.2.14 Clock power target
Setting and display screen.
As well as the standard power adjustment, it can also be set according to time slots in order to save energy.
In order to be able to set the power according to individual time slots, the field “Target Power Mode” must be set to “CLOCKED”. Then, the various times of day can be matched with four different power percentage values (100%, 75%, 50% or 25% of the set power). After defining the day of the week to be set (Target Power on day of) for each time of day, press the cursor to enter the setting bar, rotate it to define the percentage (nothing displayed corresponds to 25%, T1 corresponds to 50%, T2 corresponds to 75%, T3 corre­sponds to 100%) and press the cursor to confirm. By setting the “Copy over next day” field to “T”, the previous day setting is copied to the next day. By setting the “Reset at default” field to “T”, the settings are reset to default, where the power is low at night and full during the day.
73Use instructions
Page 74
3.1.2.15 Enable alarms SMS
Setting and display screen. Besides the alarm management “by status”, it is possible to have alarm management “by event”. The alarms for which this management mode is enabled merge in a buffer. If the value “0” is attributed to the relative alarm, it means that is deactivated, while the value “1” means that is activated to be managed in “by event” mode. This function is available only by means of connection on the Omron protocol. In order to understand the meaning of the alarms, please refer to paragraph “Alarms/ events list”.
3.1.2.16 Display alarms bit
Setting and display screen. Here is summarized the event configuration set in the menu “Enable Alarms SMS” (the “Enable”) and those that are active are highlighted (“Status” field). If the field “SMS / PSTN StatusReady” is “TRUE” means that an event is active, and has been sent alarm or phone call. To return the field “FALSE” you need to reset alarms.
74 Use instructions
Page 75
3.1.2.17 User alarms data
Setting and display screen. Some alarms can be set according to activation conditions. The current value of the alarm condition parameter (ambient temperature, RF tem­perature, RF current, power supply temperature, power supply current, direct power, reflected power) can be monitored. By setting the “En.” parameter to “T/F” the respective alarm is enabled/disabled. The following parameters can be set by the user: the parameter minimum and maxi­mum values, and the type of condition to be met (upper, lower, inside, outside).
3.1.2.18 User alarms timers
Setting and display screen. In some alarms, it is possible to set a time frame in which the condition must occur in order to make the alarm effective (“Dlay”). The trend of the meter for this time can be monitored as well as the possible enabling of the alarm by means of a status flag (Alrm).
75Use instructions
Page 76
3.1.2.19 Lifextender
Setting and display screen. The parameters relative to the Lifextender option can be monitored: equipment serial number, equipment code (parameter to be notified to Elenos should the user require the activation/deactivation of this function), activation/deactivation code (parameter supplied by Elenos to be entered for the function activation/deactivation), function sta­tus, work days in good operating conditions, work days in critical operating conditions. The algorithm considers the following parameters to define the critical days: RF tem­perature, power supply temperature, ambient temperature and reflected power with respect to maximum operating power. These parameters must exceed the threshold values for a certain amount of time. In this way, the duration and intensity of the event is assessed: intense short events are heavy; less intense but longer events are heavy too.
3.1.2.20 GSM and modem service
Setting and display screen. The GSM signal field intensity can be monitored. It is possible to enable the submission of an alarm by SMS and/or PSTN in case of no mains power (No Mains SMS) for the period of time set (Delay). It is possible to enable the submission of an alarm by SMS and/or PSTN if the power de­livered is at least 3dB less than the target set (SMS FWD over 2/3). The codes to be displayed in the different message strings can be defined (PagerId, StatId, String Id).
76 Use instructions
Page 77
3.1.2.21 Phone N.1 to 4 / N.5 to 8
Setting and display screen. The equipment can “communicate” with up to 8 SIM cards. The telephone numbers and authorizations can be defined in international format The number can be globally enabled for SMS transmission and reception SMS (En.), be enabled to send commands (Cmd), be enabled to request and receive the machine sta­tus (Sts), be enabled to receive the echo any of commands sent by other numbers (Glb) and be enabled to receive SMSs in text or digital format (PC.).
3.1.2.22 Uart 0,1 info
Control menu for testing the serial ports.
3.1.2.23 SMS Diagnostic
To see the number of SMS sent and received successfully. For more detail see paragraph “SMS List”.
77Use instructions
Page 78

3.1.3 Exciter user interface

For further information, please consult the specific manual for the exciter.
78 Use instructions
Page 79

3.2 Alarms/events list

There is an “Alarm management” module. In order to check the alarm conditions, physical and logical digital inputs are used. The status of each input is sampled and the condition is then logically processed by a combinational network so as to establish whether the alarm or signalling is active. The minimum intervention time is 100ms. This module is repeatedly performed with the same priority as ALC management, so as to constantly monitor the alarm cause onset and therefore to intervene within the required time frame. A log stores the sequence of the last events generating alarms with the date and time of activation.

3.2.1 Control unit alarms/events list

Alarm/event Description
“000 CORRECT WORKING”
“001 SYSTEM RESET”
“002 EEPROM CHKSUM ERROR”
“003 BLOCKED”
“004 STOP”
“005 -3dB CARRIER”
“006 HIGH REF PWR”
“007 RF THERMAL DERATING”
“008 RF OVER TEMPERATURE”
“009 EXTERNAL INTERLOCK” “010 ON AIR”
“011 POWER UP”
“012 POWER DOWN”
“013 EXCITER EXCHANGE”
“014 EXCITER SYNC COAX”
“015 INCORRECT COAX WORK” “016 ON LOCAL SLAVE AMPLIFIER”
This indicates correct equipment operation. The “On air” event has higher priority.
This indicates that the alarm reset is in progress. All stored and inactive alarms are removed from the list.
This indicates that the stored data is not relia­ble any longer and the machine is reconfigu­red according to the default parameters.
This indicates that the machine is blocked after making 5 restore attempts. the user must reset in order to allow the equipment to restart.
This indicates that the equipment is in stand­by mode and is ready to start without alarms.
This indicates that the equipment has been delivering power at least 3dB less than the target set, for at least a minute in start-up and 5 seconds of normal operation.
This indicates that the level of reflected output power is too high, meaning that the equipment will turn off in three block out.
This indicates a too hot temperature on ampli­fiers, which implies a reduction in maximum power output.
This indicates a maximum operating tem­perature overcoming for RF amplifier stage, resulting in shutdown of the machine in three blocks out. This protection occurs in extreme cases where the mechanism Derating was not enough to return to normal temperature values.
This indicates that interlock is active. This indicates that the device is functioning
properly and is being transmitted. This indicates that is being inserted in the
storage an alert regarding the restart of the device.
This indicates that is being inserted in the storage an alert regarding the shutdown of the equipment.
This indicates that there was an exchange of the exciter.
This indicates that an assessment of relay position was made.
This indicates that there is a relay problem. This indicates that one or more amplifiers are
in LOCAL mode.
79Use instructions
Page 80
“017 TIMEOUT SLAVE AMPLIFIER”
“018 EXCITER 1 FAULT” “019 EXCITER 2 FAULT” “020 UPS ACTIVE” “021 SW INTERLOCK INCORRECT WORK”
“022 EXCITERS FAULT” “023 WORKING MODE COMBINED”
“024 USER ENV TEMP OUT LIMIT”
“025 USER RF TEMP OUT LIMIT”
“026 USER FRW PWR OUT LIMIT”
“027 USER RFL PWR OUT LIMIT”
“028 NO AUDIO” “029 TIMEOUT SLAVE AMPLIFIER 1”
“030 TIMEOUT SLAVE AMPLIFIER 2”
“031 TIMEOUT SLAVE AMPLIFIER 3”
“032 TIMEOUT SLAVE AMPLIFIER 4”
“033 TIMEOUT SLAVE AMPLIFIER 5”
“034 TIMEOUT SLAVE AMPLIFIER 6”
“035 ETG 1 TIMEOUT/TYPE INCORRECT”
“036 ETG 2 TIMEOUT/TYPE INCORRECT”
“038 ON LOCAL ETG”
“040 SWR FOLDBACK”
This indicates that one or more amplifiers have communication problem.
This indicates that exciter 1 is fault. This indicates that exciter 2 is fault. This indicates that UPS is active. This indicates an interlock signals hardware
failure. This indicates that both exciters are fault. This indicates the machine operation in a
combined system. This indicates a deviation from the conditions
to set by user in relation to environment tem­perature measured from the apparatus.
This indicates a deviation from the conditions to set by user in relation to RF modules tem­perature.
This indicates a deviation from the conditions to set by user in relation to forward power.
This indicates a deviation from the conditions to set by user in relation to reflected power.
This indicates the absence of the audio signal. This indicates that amplifier n.1 have commu-
nication problem. This indicates that amplifier n.2 have commu-
nication problem. This indicates that amplifier n.3 have commu-
nication problem. This indicates that amplifier n.4 have commu-
nication problem. This indicates that amplifier n.5 have commu-
nication problem. This indicates that amplifier n.6 have commu-
nication problem. This indicates that exciter n.1 have communi-
cation problem/not used the correct driver. This indicates that exciter n.2 have communi-
cation problem/not used the correct driver. This indicates that the exciter is in LOCAL
mode. This indicates that the machine is having a
power reduction since the reflected power detected is too high.
80
3.2.2 Amplifier alarms/events list
Allarme/evento Descrizione
“AMP_000 CORRECT WORKING”
“AMP_001 SYSTEM RESET”
“AMP_002 EEPROM CHKSUM ERROR”
“AMP_003 BLOCKED”
“AMP_004 STOP”
Use instructions
This indicates correct equipment operation. The “On air” event has higher priority.
This indicates that the alarm reset is in progress. All stored and inactive alarms are removed from the list.
This indicates that the stored data is not relia­ble any longer and the machine is reconfigu­red according to the default parameters.
This indicates that the machine is blocked after making 5 restore attempts. the user must reset in order to allow the equipment to restart.
This indicates that the equipment is in stand­by mode and is ready to start without alarms.
Page 81
“AMP_005 -3dB CARRIER”
“AMP_006 HIGH REF PWR”
“AMP_007 MIN 12V”
“AMP_008 RF AMP. FAULT” “AMP_009 RF AMP. FAULT DERATING”
“AMP_010 RF THERMAL DERATING”
“AMP_011 RF OVER TEMPERATURE”
“AMP_012 PSU FAULT”
“AMP_013 PSU CURRENT DERATING”
“AMP_014 PSU OVER CURRENT”
“AMP_015 PSU THERMAL DERATING”
“AMP_016 PSU OVER TEMPERATURE”
“AMP_017 PSU COMM TIMEOUT”
“AMP_018 EXTERNAL INTERLOCK”
“AMP_019 ON AIR”
“AMP_020 POWER UP”
“AMP_021 POWER DOWN”
“AMP_022 PSU THERMAL FAULT”
“AMP_023 PSU LOW POWER”
“AMP_024 PSU RF OFF”
“AMP_025 WORKING MODE COMBINED”
This indicates that the equipment has been delivering power at least 3dB less than the target set, for at least a minute in start-up and 5 seconds of normal operation.
This indicates that the level of reflected output power is too high, meaning that the equipment will turn off in three block out.
This indicates that the negative voltage refe­rence is altered and prevents correct operation of the protections. Stop in three block out.
This indicates a fault on one or more RF . This indicates a fault on one or more RF mo-
dules, which implies a reduction in the overall maxi­mum deliverable power.
This indicates an excessive temperature on the RF modules which implies a reduction in the maximum output power.
This indicates that the maximum operating temperature has been exceeded, thus causing machine turn off in three block out. This pro­tection intervenes in extreme cases in which the Derating mechanism is not sufficient to make the temperature values go back to normal.
This indicates the malfunctioning of the power supply(ies).
This indicates power supply overload which causes a decrease in the power delivered.
This indicates that the machine switches off if 1 minute after derating the current still does not decrease.
This indicates power supply overheating which causes a decrease in the power delive­red.
This indicates power supply overheating which causes the equipment to switch off.
This indicates malfunctioning of the IEEE485 internal bus for communication between CPU, PSU and SHUNT.
This indicates the presence of the active interlock.
This indicates that the device is working pro­perly and is transmitting.
This indicates that the equipment restart signalling is being added to the log.
This indicates that the equipment switch off signalling is being added to the log.
This indicates power supply overheating with subsequent switching off of the machine. For ELENOS equipment with more than one power supply, the intervention of this protection aims to allow operation at reduced power, should a power supply be disconnected to protect the hardware from excessive tempe­rature.
This indicates a power drop with subsequent switching off of the equipment. For ELENOS equipment with more than one power supply, the intervention of this protection aims to allow operation at reduced power, should a power supply be disconnected to protect the hardware from a power decrease.
This indicates a problem on 50V with subse­quent switching off of the machine. For ELE­NOS equipment with more than one power supply, the intervention of this pro­tection aims to allow operation at reduced power, should a power supply be disconnected to protect the hardware from the absence of RF power.
This indicates the operation of the machine in a combined system.
Use instructions
81
Page 82
“AMP_026 SWR FOLDBACK”
“AMP_030 OVER 2/3 CARRIER”
“AMP_031 PREAMPLIFIER NOT CONNECTED”
“AMP_032 OVER MODULATION” “AMP_033 FAST INHIBIT”
“AMP_034 TEMPERATURE SENSOR ERROR”
“AMP_035 PWR FORWARD OSCILLATION” “AMP_036 THREE BLOCK OUT” “AMP_037 USER ENV TEMP OUT LIMIT”
“AMP_038 USER RF TEMP OUT LIMIT”
“AMP_039 USER PSU TEMP OUT LIMIT”
“AMP_040 USER RF CURRENT OUT LIMIT”
“AMP_041 USER PSU CURRENT OUT LIMIT”
“AMP_042 USER FRW PWR OUT LIMIT”
“AMP_043 USER RFL PWR OUT LIMIT”
“AMP_044 OUT PWR NOT VERIFIED”
“AMP_045 UPS ACTIVE”
“AMP_046 SHUNT COMM TIMEOUT”
“AMP_047 WARNING TEMPERATURE SEN­SOR”
“AMP_049 DRAIN VOLTAGE FEEDBACK ER­ROR”
“AMP_050 OVER FRW PWR ERROR”
“AMP_051 PILOT PWR GOOD”
“AMP_052 INCREASE PILOT PWR”
“AMP_053 DECREASE PILOT PWR”
“AMP_058 RTC FAULT”
This indicates that the machine is having a power reduction since the reflected power detected is too high.
This indicates that 2/3 of the power set has been exceeded.
This indicates 100% reflected power. Not implemented here.
This indicates over modulation. This indicates that there are problems on the
hardware lines leading to RF delivery inhibi­tion.
Where there are multiple RF temperature probes, this indicates that one is faulty if it measures a noticeably different value from the other probes.
This indicates oscillations in the output power. This indicates that restore procedure. This indicates a variation with respect to
the conditions set by the user relating to the ambient temperature measured by the equipment.
This indicates a variation with respect to the conditions set by the user relating to the RF module temperature.
This indicates a variation with respect to the conditions set by the user relating to the power supply temperature.
This indicates a variation with respect to the conditions set by the user relating to the RF module currents.
This indicates a variation with respect to the conditions set by the user relating to the power supply current.
This indicates a variation with respect to the conditions set by the user relating to the direct power.
This indicates a variation with respect to the conditions set by the user relating to the reflected power.
This indicates that the output power cannot be detected properly.
This indicates that the UPS is active, therefore the equipment is using the target power set for operation in this mode.
This indicates the communication timeout on the polarizer. It stops the operation of the apparatus.
This indicates a fault in the temperature probes.
This indicates the lack of control of Vds for causes such as power failures, wrong feeding, etc..
This indicates the presence of overshoot in power.
This indicates that the driving power is correct and the driver enabled.
This indicates that the driving power is in the range below, but close to the range of proper operation, and the driver is enabled. It is ne­cessary to a slight increase of the same.
This indicates that the driving power is in the range top, but close to the range of proper operation, and the driver is enabled. It is ne­cessary to a slight decrease of the same.
This indicates that there were 3 consecutive mismatches between date/time hardware and firmware, or the date is formatted incor­rectly.
82 Use instructions
Page 83
“AMP_059 RTC USER UPDATED” “AMP_060 RTC AUTOMATIC RECOVERY”
This indicates a date updates. This indicates that there is a misalignment
of more than 5 seconds between the time / date hardware and firmware.

3.2.3 Exciter alarms/events list

For further information, please consult the specific manual for the exciter.
83Use instructions
Page 84

3.3 SMS list

3.3.1 SMS commands (submit)

It is possible to submit SMSs in order to perform the following commands:
Command SMS text
Power setting to xxxxx Stand-by setting Stand-by setting On Air setting Status demand Reset demand Exciter 1 On air Exciter 2 On air The number that sends this SMS will be
disabled upon receipt alarm/status The “n” number will be disabled upon
receipt alarm/status The “n” number will be enabled upon
receipt alarm/status
PWR xxxxx STBY OFF ON STS RES EXC1 EXC2 SMSNO
SMSNO n
SMSYES n

3.3.2 Status/alarm SMS (reception)

It is possible to receive status or alarm SMSs, for example composed in this way:
Exxxx ID xx SMS String +39xxxxxxxxxx STBY No mains xx m xxx Messaggio di segnalazione FWD yyyyy W REFL yyyyy W UMB PWR yyyyy W TEMPMAX yyyyy F/C DUMMY LOAD TEMPENV yyyyy F/C Exc. x
Exxxx ID xx SMS String +39xxxxxxxxxx
-3dB Alarm No mains xx m xxx Messaggio di segnalazione FWD yyyyy W REFL yyyyy W UMB PWR yyyyy W TEMPMAX yyyyy F/C DUMMY LOAD TEMPENV yyyyy F/C Exc. x
Exxxx ID xx SMS String +39xxxxxxxxxx Status No mains xx m xxx Messaggio di segnalazione FWD yyyyy W REFL yyyyy W UMB PWR yyyyy W TEMPMAX yyyyy F/C DUMMY LOAD TEMPENV yyyyy F/C Exc. x
84 Use instructions
Page 85
Exxxx ID xx SMS String +39xxxxxxxxxx Command No mains xx m xxx Messaggio di segnalazione FWD yyyyy W REFL yyyyy W UMB PWR yyyyy W TEMPMAX yyyyy F/C DUMMY LOAD TEMPENV yyyyy F/C Exc. x
Exxxx ID xx SMS String +39xxxxxxxxxx RedPwr No mains xx m xxx Messaggio di segnalazione FWD yyyyy W REFL yyyyy W UMB PWR yyyyy W TEMPMAX yyyyy F/C DUMMY LOAD TEMPENV yyyyy F/C Exc. x
Exxxx ID xx SMS String +39xxxxxxxxxx Exc.Exchange No mains xx m xxx Messaggio di segnalazione FWD yyyyy W REFL yyyyy W UMB PWR yyyyy W TEMPMAX yyyyy F/C DUMMY LOAD TEMPENV yyyyy F/C Exc. x
Where :
Exxxx ID xx is the description of the apparatus with indication of the ID number SMS String is a customizable string of 10 characters +39xxxxxxxxxx is the telephone number of origin of the last command STBY indicates that the machine is in Standby (Off)
-3dB Alarm indicates that the machine is working below the-3dB
Status is the response to an SMS status command Command is the confirmation to a command RedPwr indicates that the machine is working in power limitation due to the UPS Exc.Exchange indicates that there was an exchange between the exciters (Dual Drivers) No mains xx m indicates that the machine has been off for the indicated time (in minutes) xxx Messaggio di segnalazione indicates a cause of arrest or a major signaling FWD yyyyy W indicates the forward power REFL yyyyy W indicates the reflected power UMB PWR yyyyy W indicates the power imbalance TEMPMAX yyyyy F/C DUMMY LOAD indicates the temperature of the load TEMPENV yyyyy F/C indicates the environment temperature Exc. x indicates the exciters state (EXC.1, EXC.2, EXC.FAULT)
Please note: The functionality of the SMS reception is interrupted for an hour, if they are sent by the system more than 5 messages over 5 min.
85Use instructions
Page 86

3.4 Externally connectable optional equipment

The equipment can be connected externally to the following units:
• PC
• Telemetry
• Exchange and/or Audio matrix
• Elenos E.BOX. module

3.4.1 Connection to PC

This connection is useful to analyse the equipment operating parameters in detail, for example during the performance assessment stage or during repairs.
To PC connection an interface must be inserted into the “Interface” connector, DB9, on the front panel of amplifiers and combiner; and add an other cable (ELENOS code CAB0068-0) to insert to PC.
This may be supplied with the product.
The connection can also be made when the machine is operating.
The Windows Hyperterminal programme can be used to display, or another equivalent available programme. For the detailed procedure for using an ASCII terminal, please request technical bulletin No. 127 from the manufacturer.
CAB0068-0
86
Use instructions
Page 87
3.4.1.1 Control unit hyperterminal interface
The Hyperterminal pages have a very similar structure to the display view, hence they will not be further described herein. Since there is more available space, there could be additional parameters.
Main Menu
Main Menù
Main RF Data (M)
Use instructions
87
Page 88
Main Menù
Profiles (O)
Main Menù
Temperatures (T)
88
Main Menù
Password (K)
Use instructions
Page 89
Main Menù
Events/Status (S)
Main Menù
Events History (H)
Use instructions
Main Menù
Clock Power Set (C)
89
Page 90
Main Menù
SMS Phone Set (P)
Main Menù
System Settings (X)
Main Menù
Password Reset (Z)
90
Use instructions
Page 91
Main Menù
Dual Drive (D)
Main Menù
RF Mode Menù (E)
Use instructions
Main Menù
RF Mode Menù (E)
Amplifiers Status (S)
91
Page 92
Main Menù
RF Mode Menù (E)
Amplifiers Data (W)
Main Menù
RF Mode Menù (E)
Amplifiers Data 2 (V)
Main Menù
RF Mode Menù (E)
Exciters Data (T)
92
Use instructions
Page 93
Main Menù
RF Mode Menù (E)
Amplifier 1...6 Data
(A,C,E,G,I,K)
Main Menù
RF Mode Menù (E)
Amplifier 1...6 Modules
(B,D,F,H,J,L)
Use instructions
Main Menù
RF Mode Menù (E)
Exciter 1...2 data (M,N)
93
Page 94
Main Menù
Status (W)
Main Menù
User Warning (F)
Main Menù
Enable Alarms (V)
94
Use instructions
Page 95
3.4.1.2 Amplifier hyperterminal interface
Main Menu
Main Menù
Main RF Data (M)
Use instructions
95
Page 96
Main Menù
Status/Alarms (S)
Main Menù
Events History (H)
96
Main Menù
Password (K)
Use instructions
Page 97
Main Menù
Password (K)
Password (K)
Main Menù
Password (K)
Password reset (R)
Use instructions
Main Menù
Password (K)
Password settings (P)
97
Page 98
Main Menù
System (Y)
Main Menù
System (Y)
System settings (X)
Main Menù
System (Y)
Clock power set (C)
98
Use instructions
Page 99
Main Menù
System (Y)
SMS phone set (P)
Main Menù
System (Y)
User warning (F)
Use instructions
Main Menù
System (Y)
En. 0-31 alrm SMS (V)
99
Page 100
Main Menù
System (Y)
En. 32-63 alrm SMS (B)
Main Menù
System (Y)
Lifextender (L)
100
Main Menù
Debug (D)
Use instructions