Please complete the RMA form (ITA http://www.elenos.com/it/elenos-rma/ or ENG http://www.elenos.
com/elenos-rma/) and provide the equipment serial number (indicated on the nameplate).
Elenos s.r.l. declares that the equipment described in this document is compliant with the 1999/05/EC
Directive.
0051
For details please refer to the “EC Marking” section.
All rights reserved. No part of this manual can be reproduced in any form without prior written authorization from Elenos
S.r.l.
With intended purpose: VHF FM broadcast transmitters and amplifiers
And manufactured by: ELENOS s.r.l.
To which this declaration relates is in conformity with the essential requirements and other relevant requirements of the R&TTE
Directive (1999/5/CE).
The product is in conformity with the following standards and/or other normative documents:
Health and safety requirements pursuant to Article 3.1.a
Standards applied: EN60215:1989+A1:1992+A2:1994
Protection requirements concerning electromagnetic compatibility pursuant to Article 3.1.b
Standards applied: EN 301 489-1 V1.6.1 ; EN 301 489-11 V1.3.1
Measures for the efficient use of the radio frequency spectrum pursuant to Article 3.2
Standards applied: EN 302 018-2 V1.2.1
Supplementary information :
Notified body involved: IMQ S.p.a.
Technical file held by : Elenos s.r.l
Place and Date: Ferrara September 05, 2013
Responsible person : Leonardo Busi (Amministratore unico)
Tel. +39 0532 829965
e-mail: [email protected]
4.5 Operating faults (symptoms, causes and remedies) .................................................... 127
Contents
11
Page 12
12Contents
Page 13
1 General information
1.1 Intended use
The equipment referred to in this manual is solid state transmitters with adjustable
output power from 0W to a maximum rated value (see Section “Series models”), to be
used in the whole FM band between 87.5 and 108 MHz, in 10 kHz steps.
The design of such equipment is based on SCALABILITY: it envisages the reuse on
different scale levels of resources used on a basic model (the E5000 amplifier), so as to
obtain higher transmission powers.
The same technology, same user interfaces and same components within each module
mean more economical spare part and repair management, more economical ope-rator training and experience which can be easily shared with others.
The available options are as follows: STEREO, AES/EBU (both with integrated MPX), according to the relative modulator version.
The distinctive characteristics of Elenos products remain constant: ECOSAVING, ICEFET,
VSWR PEAK HOLD, monitoring possibility, protection against corrosion, etc..
The LIFEXTENDER functionality can be added.
1.2 Transport
The equipment must only be transported in its original packaging. However, although it
has been designed to prevent the machine being damaged,
even in the event of incorrect manoeuvres, it is recommended to respect the “HIGH/
LOW” direction and not to subject it to impact.
Ensure that the transport and lifting equipment are suitable for supporting the load.
1.3 Unpacking
The personnel in charge of handling the load must use protective gloves and accidentprevention footwear.
Before lifting or moving the equipment or any of its parts, check that the operating area
has been cleared, also considering a safe area in order to prevent damage to people
and/or properties that could be within the manoeuvring radius.
1.4 Storage
Should it be necessary to store the equipment for any reason, it is necessary that:
• in the storage area, the temperature is between -20° and +55°C, with humidity of
no more than 90% at 55°C;
• the equipment is disconnected from energy sources;
• the equipment is clean and there are no dust deposits;
• the equipment is covered with a waterproof sheet.
General information
13
Page 14
1.5 Decommissioning and disposal
For all the aspects regarding the disposal of the product, please refer to the specific
European Directives.
Please note that the equipment DOES NOT CONTAIN POLLUTANT OILS.
1.6 Checking the product purchased
Before installing the equipment, it is important to check that it was not damaged during transport or storage. Check that all standard components and accessories ordered
have been delivered correctly, otherwise contact Elenos s.r.l.
In this case, the package must contain at least the following:
• n°1 piece of equipment from the ET30000-5, ET25000-5, ET20000-5, ET15000-5,
ET10000-5, ET5000, ET3500, ET2500 series;
• n°1 “Identification and Quick Start” manual, which we recommend keeping with
the product;
It may also contain:
• n°1 “User” manual;
• n°1 CD containing all the documentation relative to Elenos s.r.l. manuals;
• n°1 PC connection cable.
Cables, spare parts and other accessories may be requested from Elenos S.r.l. or Elenos
retailers.
14General information
Page 15
2 Product description
2.1 Combiner/Splitter unit
3
112
4
677
8888
5
9999
77
Product description
15
Page 16
1 FAN - cooling fans. There are two, 12-28Vdc, 306M3/h max.
2 GRILL - ventilation grille.
3 RF OUT - RF output connector 3”+1/8
4 PWS - 3W3 connector for the fan power supply.
5 AUX1 - unused connector.
6 SPLITTER IN - N connector for RF splitter input.
7 LOAD - four 7/16 connectors for unbalanced load outputs.
8 SPLITTER OUT - four N connectors for RF splitter outputs.
9 POWER IN - four 7/8 connectors for RF amplifier inputs.
16Product description
Page 17
2.2 Control unit (ET30000-5, ET25000-5,
ET20000-5)
8
23
14
15
16
17
1819
20
2321
22
1
91011
4 567
12
11
13
2727262524
Product description
17
Page 18
1 GRILL - ventilation grille.
2 DISPLAY - display showing the operating parameters and selected functions using the
encoder.
3 ENCODER - multifunction knob allowing navigation through the function menus and
modification of the operating parameters.
4 KEY SELECTOR - it can be set to LOCAL (controllable through the front panel) or REMOTE (controllable via PC) mode, by turning the key supplied with the equipment.
5 WARNING LIGHTS - LED list:
• FAULT (red) _ this warning light is on when the equipment is considered to be in
“FAILURE”;
• ON AIR (green) _ this warning light is on when the apparatus is broadcasting;
• ST-BY (yellow) _ this warning light is on when the apparatus is not broadcasting;
• LOCAL (blue) _ this warning light is on during local programming;
• MAINS (green) _ this warning light is on when power is supplied.
6 INTERFACE - B9 F connector for connection with telemetry according to the EIA485
standard, or to a PC.
7 RF MONITOR - BNC connector for connection with external measurement tools, allowing to the RF signal to be taken at a low level (0dBm at scale bottom). This monitor
is not calibrated, therefore it is not guaranteed that the output level stays constant as
frequency changes. It CANNOT be used for measuring the output power, or for measu-
ring the harmonic components.
9 PROGRAMMING LEVER – Located on the right hand side of the panel facing the machine. It can be moved by means of a flat screwdriver upwards (in running mode) and
downwards (in program mode).
9 VDE - VDE socket for the equipment power supply.
10 EXCITER DUMMY LOAD - N connector for internal unbalanced load input.
11 RF IN - two N connectors for modulator RF inputs.
12 RF OUT - N connector for RF splitter output.
13 DUMMY LOAD - N connector for reserve exciter load.
14 PROFILES - DB25 F connector. Normally unused. It is used for the selection of profiles
stored (in the case of apparatus as a reserve).
15 TC/TS - DB25 F connector for remote control and remote telesignalling.
16 MASTER - DB25 F connector for interface with amplifiers and modulators.
17 SLAVE - unused connector.
18 INTERLOCK - unused connector.
19 IEEE485 - DB9 F connector for connection with telemetry according to the EIA485
standard.
20 AUX 1 - DB9 F connector for environment temperature probe.
21 FWD- BCN connector for forward power input.
22 REF - BNC connector for reflected power input.
23 MONITOR - BNC connector for low level signal input in antenna.
24 DUMMY LOAD - DB9 F connector for unbalanced load connection.
25 PWS DUMMY LOAD - 3W3 connector for the unbalanced load fan power supply.
26 PWS COMBINER - 3W3 connector for combiner fan power supply.
27 FAN - cooling fans. There are two, 12-28Vdc, 306M3/h max.
1 GRILL - ventilation grille.
2 DISPLAY - display showing the operating parameters and selected functions using the
encoder.
3 ENCODER - multifunction knob allowing navigation through the function menus and
modification of the operating parameters.
4 KEY SELECTOR - it can be set to LOCAL (controllable through the front panel) or REMOTE (controllable via PC) mode, by turning the key supplied with the equipment.
5 WARNING LIGHTS - LED list:
• FAULT (red) _ this warning light is on when the equipment is considered to be in
“FAILURE”;
• ON AIR (green) _ this warning light is on when the apparatus is broadcasting;
• ST-BY (yellow) _ this warning light is on when the apparatus is not broadcasting;
• LOCAL (blue) _ this warning light is on during local programming;
• MAINS (green) _ this warning light is on when power is supplied.
6 INTERFACE - B9 F connector for connection with telemetry according to the EIA485
standard, or to a PC.
7 RF MONITOR - BNC connector for connection with external measurement tools, allowing to the RF signal to be taken at a low level (0dBm at scale bottom). This monitor
is not calibrated, therefore it is not guaranteed that the output level stays constant as
frequency changes. It CANNOT be used for measuring the output power, or for measu-
ring the harmonic components.
8 FAN - cooling fans. There are three on the front panel, 12-28Vdc, 441Mc/h max.
There are three on the front panel on the rear panel (only on ET15000-5), 12-28Vdc,
306Mc/h max.
9 PROGRAMMING LEVER – Located on the right hand side of the panel facing the machine. It can be moved by means of a flat screwdriver upwards (in running mode) and
downwards (in program mode).
10 VDE - VDE socket for the equipment power supply.
11 SPLITTER OUT CONNECTORS - BNC connector for RF output from splitter. There are
two in ET10000-5, three in ET15000-5.
12 EXCITER IN CONNECTORS - N connector for RF input from exciter. There are two.
13 AMPLIFIER IN - 7/8” connector for RF input from amplifiers.
14 RF OUT - 3” 1/8 connector (on ET15000-5), 1” 5/8 (on ET10000-5).
15 PROFILES (see paragraph 2.2.1.2)- DB25 F connector. Normally unused. It is used for
the selection of profiles stored (in the case of apparatus as a reserve).
16 TC/TS (see paragraph 2.2.1.3/ 2.2.1.4) - DB25 F connector for remote control and
remote telesignalling.
17 MASTER (see paragraph 2.2.1.5) - DB25 F connector for interface with amplifiers and
modulators.
18 SLAVE - unused connector.
19 INTERLOCK - unused connector.
20 IEEE485 (see paragraph 2.2.1.6) - DB9 F connector for connection with telemetry
according to the EIA485 standard.
26Product description
Page 27
2.4 Dummy load
222
1
2223
4
5555
Product description
27
Page 28
1 GRILL - ventilation grille.
2 FAN - cooling fans. There are six, 12-28Vdc, 441M3/h max.
3 DUMMY LOAD - DB9 M connector for control unit connection.
4 PWS DUMMY LOAD - 3W3 connector for power supply.
5 RF IN - four 7/16 connectors for RF combiner inputs.
1 GRILL - ventilation grille.
2 DISPLAY - display showing the operating parameters and selected functions using the
encoder.
3 ENCODER - multifunction knob allowing navigation through the function menus and
modification of the operating parameters.
4 KEY SELECTOR - it can be set to LOCAL (controllable through the front panel) or REMOTE (controllable via PC) mode, by turning the key supplied with the equipment.
5 WARNING LIGHTS - LED list:
• MAINS (green) _ this warning light is on when power is supplied;
• ON AIR (green) _ this warning light is on when the apparatus is broadcasting;
• ST-BY (yellow) _ this warning light is on when the apparatus is not broadcasting;
• EXCITER OK (yellow) _ this warning light is on fixed in conditions of correct driving;
• FAULT (red) _ this warning light is on when the equipment is considered to be in
“failure”;
• LOCAL (light blue) _ this warning light is on during local programming.
6 BUTTONS/CONTROLS – Button list :
• LIFEXTENDER _ This button displays the state of the LifExtender optional function
(active/inactive, days of activity, critical days of activity);
• OFF _ this button allows the equipment to be put on Stand-by;
• ON_ this button allows the equipment to be put On Air;
• ESC _ this button moves the user back previous level in the menu.
7 EIA485/TELEMETRY – DB9 F connector for connection with telemetry according to the
EIA485 standard, or with a PC.
8 RF MONITOR – BNC connector for connection with external measurement tools, allowing to collect the RF signal at low level (0dBm at scale bottom).
This monitor is not calibrated, therefore it is not guaranteed that the output level stays
constant as the frequency changes.
It CANNOT be used for measuring the output power, nor for measuring the harmonic
components.
9 PROGRAMMING LEVER – Located on the right hand side of the panel facing the machine. It can be moved by means of a flat screwdriver upwards (in program mode) and
downwards (in running mode). For the detailed loading procedure of the software, ask
the manufacturer for the technical bulletin No.125.
10 POWER SUPPLY TERMINAL BOARD – Terminal board with 6 contacts connecting the
three internal power supplies. For details of the connection mode, please refer to section “Quick instructions for commissioning”.
11 EARTHING SCREW – Eyelet for earthing the equipment, located behind the flange of
the output coaxial connector.
12 RF IN - N type.
13 RF OUT - 7/8” type.
14 TC/TS – DB25 F connector for remote control and remote telesignalling.
15 PROFILES – DB25 F connector to be used as reserve equipment in an N+1 system.
16 TCP/IP, RESERVED – Connector for remote connection functions.
17 EIA485 – DB9 F connector for connection with telemetry according to the EIA485
standard.
18 FAN - cooling fans. There are six, 120x120x38 mm, 12-28Vdc, 306Mc/h max.
30Product description
Page 31
2.5.1 External connectors pin-out
2.5.1.1 EIA485/TELEMETRY connector
ConnectorPinMeaningNotes
CN3 on TG5K2A881
board
1Com1 TX+EIA485/422
2Com1 TX-EIA485/422
3Com1 RX+EIA485/422
4Com1 RX-EIA485/422
5Common groundConnected to the
Cooling systemForced air-cooling . From 600 to 1200 m3/h
Air temperature increase17 °C
Acoustic noise< 65 phon
ENVIRONMENT
Temperature range (operating)-5 ÷ +45 °C, 23 ÷ 113 °F
Temperature range (non operating)-20 ÷ +55 °C, -4 ÷ 131 °F
Humidity range (operating)95% @ 40 °C, 104 °F
Humidity range (non operating)90% @ 55 °C, 131 °F
Altitude range (operating)<3000 meters / <9840 Feet
Altitude range (non operating)<15000 meters / < 49200 Feet
TELECONTROL & TELEMETRY
Remote controlYes
Remote control, dry contactsYes
SNMP optionYes (external)
@ transmitter room, 2 m distance of the
front of transmitter
Product description
51
Page 52
2.9 Protections
The equipment has an integrated protection system both for the hardware and the
software.
2.9.1 Software protections
2.9.1.1 IPF (Intelligent Proportional Foldback)
Mechanism which is activated on the control unit and works on each individual machine.
The IPF is an intelligent system which reduces the equipment’s output power in the
event of strong load mismatch, thus preventing the machine from turning off.
The activation of this feature is shown on the display as alarm “026” for modulators and
“030” for amplifiers.
2.9.1.2 IPC (Intelligent Power Control)
It is provided on the amplifiers in the system.
When the equipment is working properly, the IPC keeps the amplifier output power
constant
(and subsequently, the transmitter output power) within +/-1% of the target set, irrespective of mains voltage, temperature and load variations.
The IPC also allows the RF section efficiency to be optimized by making the MOSFETs
constantly work at maximum efficiency, thus minimizing overall electrical consumption.
2.9.1.3 Safety Management (“Lifextender” option) ®
The Safety Management consists of algorithms which perform a real-time analysis of
the transmitter’s operating status and operates in order to maintain the output power
set, according to the type and severity of any errors (internal or environmental) that
may occur.
The Safety Management can control an output power reduction proportional to the
severity of the error that arises.
The algorithms act at different levels and in various sections of the equipment: Thermal
Management on the RF unit, Thermal Management on Dummy Load, Current Management on the power supply unit, Thermal Management on the power supply unit, Fault
management on the RF unit, Fault Management on the power supply unit, Cooling
Management on the fan unit.
Thermal Management on the RF unit (Lifextender) ®
It is provided on amplifiers and exciters.
If the temperature measured in the vicinity of the MOSFETs exceeds 72 °C, a first level
of derating intervenes slightly in order to reduce the temperature through an output
power reduction.
The power reduction is the lowest possible that allows a thermal balance to be reached
at a temperature of less than 72 °C.
The output power reduction never exceeds 40% with this first derating. In other words,
the output power is always 60% higher than that set by the user, and the “- 3 dB” warning with corresponding alarm does not intervene. This first derating level is effective in
virtually all cases.
The activation of this feature is shown on the display as alarm “010”.
Should the first level derating be insufficient (extremely rare), a second level intervenes, further reducing the power, thus obtaining a thermal balance status which is
compatible with the safe operation of the equipment even if it is below – 3 dB (with
subsequent “005” alarm).
52Product description
Page 53
If the second derating is ineffective (in case of external conditions which are not compatible with the safe operation of the equipment) the equipment switches off.
In this case, if the temperature decreases, the power is raised again proportionally.
If it decreases by 20°C the derating feature is exited and full power is restored. After 3
failed attempts, the control logic locks the equipment (alarm “011”).
Thermal Management on Dummy Load
If the temperature measured in the vicinity of the Dummy Load exceeds 90°C, a first level of derating intervenes slightly in order to reduce the temperature through an output
power reduction.
The power reduction is the lowest possible that allows a thermal balance to be reached
at a temperature of less than 90 °C.
The output power reduction never exceeds 40% with this first derating. In other words.
the output power is always 60% higher than that set by the user, and the “- 3 dB”
signaling does not intervene.
This first derating level is effective in virtually all cases.
If the first level derating is insufficient (extremely rare), a second level intervenes,
further reducing the power, thus obtaining a thermal balance status which is compatible
with the safe operation of the equipment even if it is below - 3dB (with subsequent
corresponding alarm).
If the second derating is ineffective (in case of external conditions which are not compatible with the safe operation of the equipment) the equipment switches off.
Thermal derating has a 10°C hysteresis before it attempts to restore the normal operating conditions of the equipment.
After 3 failed attempts, the control logic locks the equipment.
Current management on the power supply unit (Lifextender) ®
It is provided on amplifiers and exciters.
This is activated when the maximum current for continuous operation of the power
supply is exceeded.
This value is set below the deliverable current limit and constitutes the threshold which
can be exceeded only for short periods (maximum 1 minute at a time). If this situation arises, the “PSU current derating” function is activated (alarm “013” and/or “014”
relative to amplifiers and modulators) and the ALC management algorithm, envisaged
for normal operating conditions, is replaced by another one wherein the VDS control
and Bias is determined by the power set and, with even higher priority, by the current
delivered by the power supply.
The current derating condition is deactivated when the power delivered returns to the
value set by the user and if the maximum current delivered by the power supply is less
than or equal to the maximum value allowed for continuous operation.
Thermal management on the power supply unit (Lifextender) ®
It is provided on amplifiers and exciters.
The power supply management algorithm according to the temperature is the same as
that on the RF unit, and it is logically connected in “OR” to the latter.
The first Derating level (acting directly on the output power) is activated when the power supply temperature exceeds 75°C, while the second level is activated - if the first is
ineffective - if the temperature does not stabilize below this value.
In the latter case, the output power is brought below – 3 dB with the same procedure
as that described for the RF section.
The activation of this feature is shown on the display as alarm “015” and /or”016” relative to amplifiers and modulators.
53Product description
Page 54
Fault management on RF modules (Lifextender) ®
It is provided on amplifiers and exciters.
This manages the maximum deliverable power according to the number of RF amplifier
modules considered to be operating correctly.
If one or more MOSFETs are considered faulty (this happens when the absorbed current
is 10% below the average value), the RF output power is reduced to the expected value
when a fault occurs.
The failure case report and the relative maximum power achievable is described in a
complex table obtained through tests. It is designed to stop failure propagation and
prevent excessive stress on the MOSFETs that still work due to the ALC feature (which
would require them to deliver all the missing output power).
In order to prevent a ridiculously high number of alarm SMSs, no messages are sent
during this phase: the alarm SMS, if validated, is only sent after the adaptation procedure of the output power according to the table parameters and only if the -3dB condition
occurs on the output power.
The activation of this feature is shown on the display as alarms “008” and “009” relative to amplifiers and modulators.
Cooling Management on the fan unit (Lifextender) ®
According to the actual cooling requirements, the rotation speed of the fans is adjusted
from a minimum of 60% to a maximum of 120% approx. (these values may vary according to the models of fan used).
The cooling requirement is estimated based on the accurate temperature measurements which are performed in correspondence with the RF MOSFETs and the power
supply unit in the case of amplifiers and modulators and on the Dummy Load.
The Cooling Management aims to extend the effective lifetime of the fans, minimize
the quantity of dust that may be transported by the air flow and allow the safe operation of the equipment also under extreme temperature conditions.
Without the Lifextender the fans always work at 100%.
2.9.2 Hardware protections
The hardware protection system comprises:
• fast electronic and fuse protection of power supplies;
• fast electronic protection on the fan power supply;
• fast protection against excess reflected power (SWR/VSWR) following a strong load
mismatch. This protection is activated when the reflected power value exceeds 10%
of the forward power;
• protection against splitter and combiner overheating through fans with a thermostat;
• designed based on redundancy so as to eliminate the “SINGLE-POINT-FAILURE”, that
is any points which alone define an OFF-AIR situation;
• construction of metal parts in stainless steel and aluminium, treatment of the electronic boards with protective paint (tropicalization), closing off the most sensitive
components to air flow with special shields in order to provide protection against
corrosion.
54Product description
Page 55
2.10 Options
The equipment in this series can be purchased with different options included:
Version with modulating
signal input
MPX
Inputs:
• MPX
• Aux 1
Outputs:
• MPX monitor
STEREO
Inputs:
• Left channel
• Right channel
• MPX
• Aux1
• Aux 2
Outputs:
• MPX monitor/19 kHz
AES/EBU
Inputs:
• Left channel
• Right channel
• MPX
• Aux 1
• Aux 2
• AES-EBU
Output:
• MPX monitor/19 kHz
Purchase information: please request the following codes
• circuit breaker box positioned front or back (according to the type of model);
• cooling fan;
• technical panel and output connector positioned on the roof or rear (according to
the type of model).
The LifExtender can be requested as an option using the previous codes. To be specified
in the order.
55Product description
Page 56
56Product description
Page 57
3 Use instructions
3.1 User interface
3.1.1 Control unit user interface
The controls and display views of the control unit (representing the combined system
interface as a whole) are described below.
Please note that in order to have complete visibility of all the available interfaces, the equipment must be set to LOCAL mode and it must be accessed with the specific
passwords.
Specifically in REMOTE mode you lose visibility of the menus 485 SPEED SET, COM.ID LC/
RT DISP MODE, TEMPERATURE UNIT, MAX REFLECTED POWER SWR FOLDBACK SETTING, NO
MAINS AARM SETTING, UPS SETTINGS, GSM/MODEM menu.
Turn the encoder to navigate through the menu items.
To enter the desired item or to access a sub menu press the encoder while on the “>”
icon.
To exit an item press the encoder while on the “<” icon.
If you change the value of a parameter, to maintain it, before turn off the machine wait at least 60seconds.
In the case of systems without control UNIT (ET5000, ET3500, ET2500) should be taken
as reference the interfaces of the amplifier and the modulator.
Warning: the screen pictures shown below and the values attributed to the parameters
are provided for illustrative purposes only. The parameters shown may vary slightly
according to the equipment and setup type of the audio board.
Use instructions
57
Page 58
POWER SETTING
INPUT PASSWORD
PROFILE
MAIN ALARM
TEMPERATURES
MAIN VIEW
DUAL DRIVE
DUAL DRIVE DRIVE
DUAL DRIVE HANDLER
TEMPERATURES DL
485 SPEED SET
MENU SYSTEM
MENU GSM/PSTN
EVENTS LIST
EVENTS HISTORY
VOLTAGES
SYSTEM INFO
SYSTEM TIME
CLOCK PWR TARGET
COM.ID LC/RT DISP MODE
TEMPERATURE UNIT
NO MAINS ALARM SETTING
PASSWORD SETTING
PASSWORD RECOVERY
UPS SETTINGS
MENU UARTS
EXIT
UART0 INFO
UART1 INFO
UART2 INFO
EXIT
MAX REFLECTED POWER
SWR FOLDBACK SETTING
-3dB ALARM SETTING
STRING ID/PAGER ID
PHONE N.1..5
EXIT
GSM FIELD STRENGTH
FREQUENCY SETTING
58
Use instructions
Page 59
3.1.1.1 Power setting
Indication on the forward and reflected power.
Setting the desired target power, activating the transmission and enabling the profile.
3.1.1.2 Frequency setting
Setting the desired frequency.
3.1.1.3 Input password
Some items are reserved and therefore can only be viewed and/or edited depending
on the user authorisations. Here you can enter the access password.
3.1.1.4 Profile
Enabling the profile and displaying the power values of each profile.
3.1.1.5 Main alarm
Indication on the latest alarm occurred or on the correct operating condition. The
forward power value is shown. Here the alarms can be reset.
Use instructions
59
Page 60
3.1.1.6 Temperatures
Indication of the dummy load temperature, environment temperature, reserve exciter
load temperature, fan speed.
The temperature indications depend on the presence of probes inside the equipment.
Therefore, for certain types of equipment, some of these values may not be available.
3.1.1.7 Main view
Displaying the following parameters: forward power, reflected power, efficiency, current
and voltage.
3.1.1.8 Events list
Alarm list. Those showing a letter “A” at the front are active. For further details, please
see the “Alarms/events list” paragraph.
3.1.1.9 Events history
Indication of the date and time of each alarm.
60Use instructions
Page 61
3.1.1.10 Dual drive
Setting the exchange between the exciters in manual/automatic mode, as well as the
maximum number of times for the exchange. Indication of which exciter is
on the antenna and which is on the load. By selecting “CHANGE” here, it is possible to
force the exchange.
3.1.1.11 Dual drive drive
Setting the exchange between the exciters in manual/automatic mode, as well as the
maximum number of times for the exchange. Indication as to whether the exciters are
“On Air” or not, and in alarm or not.
3.1.1.12 Dual drive handler
Setting the exchange between the exciters in manual/automatic mode, viewing the
relay position, assigning the exciters to the antenna or the load.
3.1.1.13 Temperatures DL
Indication of the maximum temperature detected on the dummy load, the envirnment
temperature, the individual temperatures detected on each load module.
The temperature indications depend on the presence of probes inside the equipment.
Thus, on certain types of equipment some of these values may not be available.
61Use instructions
Page 62
3.1.1.14 485 speed set
Setting the front and rear serial port 485 speed.
3.1.1.15 Voltages
Displaying the voltage values.
3.1.1.16 System info
Indication of the software version, the protocol version and the equipment activity time.
3.1.1.17 System time
Setting the day of the week, the date and the time.
62Use instructions
Page 63
3.1.1.18 Clock pwr target
As well as the standard power adjustment, it can also be set according to time slots in
order to save energy.
For the power delivered to be set according to individual time slots, the option which
makes it fixed for 24 hours must be deactivated.
To do so set “For All 24 Hours: FALSE”.
The list of the time slots into which the whole day is divided is then displayed. Each
time slot lasts one hour.
Go to the time slot for which you want to change the power, press the encoder to make
it editable, set the new target power by turning the encoder, then press again to confirm.
3.1.1.19 Com. ID LC/RT disp. mode
Setting the addresses and activating the display so that the menus are also visible in
REMOTE mode.
3.1.1.20 Temperature unit
Setting the temperature unit of measurement.
63Use instructions
Page 64
3.1.1.21 Max reflected power
The maximum reflected power permitted is 10% of the nominal power.
Here it is possible to set a lower value when required by the user.
Warning: in this case, correct operation of the foldback is not guaranteed.
3.1.1.22 SWR foldback setting
Foldback activation.
Algoritmo foldback
The Elenos devices feature two different and independent protections which are activated when there is excess reflected power.
The first is a hardware threshold which operates when the reflected power exceeds
10% of the maximum rated output power of the transmitter in a very short space of
time.
In these conditions the transmitter switches off.
The second is a software protection, called “foldback algorithm”.
It is activated when the reflected power increase is slower (for example, when there is
snow or ice on the antenna).
In these conditions, the transmitter gradually reduces its output power until the reflected power threshold is exceeded, while the output power is gradually restored
when the values go back to normal.
If normal operating conditions continue for more than 60 seconds, the algorithm is
inactive.
The activation of this second protection is left to the user (from the SWR foldback setting screen).
3.1.1.23 No mains alarm setting
Setting the alarm, sent through an SMS, in the event of power failure for a set period of
time.
64Use instructions
Page 65
3.1.1.24 Password setting
There are two levels of user privilege: USER and SYSTEM, which are both initially protected by the default password “0000”.
In this screen it is possible to define customized passwords by the user with “SYSTEM”
privileges.
Other parameters that can be set from this menu are the machine addresses (reference for communication with it).
3.1.1.25 Password recovery
If you lose your password, please contact Elenos.
Elenos must be given the “Unlock code” displayed on this screen.
Elenos will provide a password valid for 24 hours to be entered on the same screen
under the “Password Recovery” item.
The user must later define new passwords through the “Password Setting” screen.
3.1.1.26 UPS settings
Setting the target power to be used when the machine is working with an uninterruptible power source.
65Use instructions
Page 66
3.1.1.27 Uart 0,1,2 info
Control menu for checking the serials.
66Use instructions
Page 67
3.1.1.28 GSM field strength
Indicating if the equipment is enabled to broadcast and receive SMSs, if it is in calling
mode through the modem analog line.
The GSM coverage field is shown.
For further details, please see the “SMS list” paragraph.
3.1.1.29 -3dB alarm setting
Enabling the alarm -3dB to be sent by SMS.
This indicates that 2/3 of the power set has been exceeded.
3.1.1.30 String ID/Pager ID
Defining the workstation name and the codes to be viewed in the message strings.
3.1.1.31 Phone N.1 .. 5
Various SIM cards can “communicate” with the equipment (based on the customer
requirements).
The telephone numbers in international format and authorizations can be set in these
templates.
The number can be globally enabled for SMS transmission and reception (en), be enabled to send commands (cm), be enabled to request and receive the machine status
(st), be enabled to receive the echo any of commands sent by other numbers (gl) and
be enabled to receive SMSs in text or digital format (PC.)
67Use instructions
Page 68
TX CONTROL PANEL
3.1.2 Amplifier user interface
SYSTEM CONFIG
GSM AND MODEM SERVICE
SYSTEM CONFIG 1
PHONE N.1 TO 4/PHONE N.5 TO 8
COMMUNICATION PORT SET
EXIT
VIEW TX PARAMETERS 1
VIEW TX PARAMETERS 2
ALARMS LIST
EVENTS HISTORY
PASSWORD
PASSWORD SETTING
SYSTEM INFO
SYSTEM TIME
CLOCK PWR TARGET 1 OF 2
CLOCK PWR TARGET 2 OF 2
ENABLE ALARMS SMS
DISPLAY ALARMS BIT
UART 0 INFO/UART 1 INFO
68
PASSWORD RECOVERY
MENU SYSTEM
MENU DIAGNOSTIC
Use instructions
USER ALARMS DATA
USER ALARMS TIMERS
LIFEXTENDER
MENU GSM/MODEM
EXIT
SMS DIAGNOSTIC
EXIT
Page 69
3.1.2.1 TX control panel
Main screen which appears automatically when turning on in LOCAL mode. It is used to
set and check the main operating parameters (target power, forward power, reflected
power, interlock led, reduction power led).
3.1.2.2 View TX parameters 1
Display only screen.
The parameters which can be monitored are as follows: number of active profile,
efficiency, transmitter working hours, fan working hours, direct power target, effective
direct power value, reflected power, driving power, current, voltage, maximum temperature and fan speed.
3.1.2.3 View TX parameters 2
Display only screen.
The parameters which can be monitored are as follows: current and temperature of the
amplifier modules, current, voltage and temperature of the power supplies, voltages of
auxiliary power supply, sum of the power supply currents, sum of the module currents,
voltage, ambient temperature and efficiency.
69Use instructions
Page 70
3.1.2.4 Alarms list
Display only screen.
It is possible to monitor the list of most recent alarms.
The alarms indicated by the letter “A” are still active.
In order to understand the meaning of the alarms, please refer to paragraph “Alarms/
events list”.
3.1.2.5 Events history
Display only screen.
The log of all the events/alarms occurred (up to 99) can be monitored. These are indicated by code, description, date and time.
3.1.2.6 Password
The equipment is delivered with the default password “0000” that can be customized
by the user (for more details, please see paragraph “Password Setting”).
In this screen the access password must be entered.
3.1.2.7 Password setting
There are two levels of user privilege: USER and SYSTEM, which are both initially protected by the default password “0000”.
In this screen it is possible to define customized passwords by the user with “SYSTEM”
privileges.
70Use instructions
Page 71
Other parameters that can be set from this menu are the machine addresses (reference
for communication with it).
3.1.2.8 Password recovery
If you lose your password, please contact Elenos.
Elenos must be given the “Unlock code” in this screen.
Elenos will provide a password valid for 24 hours to be entered on the same screen
under the “Password Recovery” item.
The user must later define new passwords through the “Password Setting” screen.
3.1.2.9 System config
Setting and display screen.
The following parameters can be set by the user: temperature measurement unit
(Temp. U.), remote display operating mode (Show D.), equipment protection in case
of oscillations (PwOscChk), power target when working with a UPS (UPS T), minimum
number of sensors on which to perform the check on the functionality resulting in sending alarm (Min T.Sen), power reading calibration (FwdPwrCal), SWR foldback, polarization threshold (IPA Bias Tres.), reflected power nominal threshold (Refl.Pwr T.N., when
active it is 10% of direct power), reflected power customized threshold (Refl.Pwr T.Lev.,
when the nominal threshold is inactive, it is possible to set values below10%), final
polarization (PAbias), maximum settable power full scale (Max Target Pwr).
Power oscillation algorithm
In Elenos devices, if there is a power variation of “n” W (“n” being defined in specific
tables) at least 3 consecutive times within 15 seconds, the “035” alarm is activated and
the three block out mechanism is triggered (if this mechanism fails, the “003” alarm is
then activated).
71Use instructions
Page 72
3.1.2.10 System config 1
Setting and display screen.
The alarm signal, caused by wrong output power, snaps by default at -3dB of target
power and disappears when you reach the 2/3 of that.
The “Min Level Fwr Pwr Fault” additional parameter, set here, acts in an AND condition
with the standard algorithm: so, the alarm will snap when there is the first between the
two conditions “-3dB” and “Min Level Fwr Pwr Fault“, while will disappear when the
highest value between ”2/3 Ptarget“ and ”Min Level Fwr Pwr Fault+typical step related
to apparatus“ occurs.
For stand-alone devices meant to set Min Level Fwr Pwr Fault to a value greater than3dB, while using lower values may have meaning in N+1 systems.
By default Min Level Fwr Pwr Fault is set to the minimum value of power.
3.1.2.11 Communication port set
Setting and display screen.
The parameters which can be set by the user are the speed and the front and rear 485
door addresses.
3.1.2.12 System info
Setting and display screen.
The equipment software version, the protocol version, the equipment activity time and
the fan operating time are indicated.
It is possible to reset the latter by clicking “R”.
72Use instructions
Page 73
3.1.2.13 System time
Setting and display screen.
The following parameters can be set by the user: the day of the week, date and time.
3.1.2.14 Clock power target
Setting and display screen.
As well as the standard power adjustment, it can also be set according to time
slots in order to save energy.
In order to be able to set the power according to individual time slots, the field “Target
Power Mode” must be set to “CLOCKED”.
Then, the various times of day can be matched with four different power percentage
values (100%, 75%, 50% or 25% of the set power).
After defining the day of the week to be set (Target Power on day of) for each time of
day, press the cursor to enter the setting bar, rotate it to define the percentage (nothing
displayed corresponds to 25%, T1 corresponds to 50%, T2 corresponds to 75%, T3 corresponds to 100%) and press the cursor to confirm.
By setting the “Copy over next day” field to “T”, the previous day setting is copied to
the next day.
By setting the “Reset at default” field to “T”, the settings are reset to default, where
the power is low at night and full during the day.
73Use instructions
Page 74
3.1.2.15 Enable alarms SMS
Setting and display screen.
Besides the alarm management “by status”, it is possible to have
alarm management “by event”.
The alarms for which this management mode is enabled merge in a buffer.
If the value “0” is attributed to the relative alarm, it means that is deactivated, while
the value “1” means that is activated to be managed in “by event” mode.
This function is available only by means of connection on the Omron protocol.
In order to understand the meaning of the alarms, please refer to paragraph “Alarms/
events list”.
3.1.2.16 Display alarms bit
Setting and display screen.
Here is summarized the event configuration set in the menu “Enable Alarms SMS” (the
“Enable”) and those that are active are highlighted (“Status” field).
If the field “SMS / PSTN StatusReady” is “TRUE” means that an event is active, and has
been sent alarm or phone call.
To return the field “FALSE” you need to reset alarms.
74Use instructions
Page 75
3.1.2.17 User alarms data
Setting and display screen.
Some alarms can be set according to activation conditions.
The current value of the alarm condition parameter (ambient temperature, RF temperature, RF current, power supply temperature, power supply current, direct power,
reflected power) can be monitored.
By setting the “En.” parameter to “T/F” the respective alarm is enabled/disabled.
The following parameters can be set by the user: the parameter minimum and maximum values, and the type of condition to be met (upper, lower, inside, outside).
3.1.2.18 User alarms timers
Setting and display screen.
In some alarms, it is possible to set a time frame in which the condition must occur in
order to make the alarm effective (“Dlay”).
The trend of the meter for this time can be monitored as well as the possible enabling
of the alarm by means of a status flag (Alrm).
75Use instructions
Page 76
3.1.2.19 Lifextender
Setting and display screen.
The parameters relative to the Lifextender option can be monitored: equipment serial
number, equipment code (parameter to be notified to Elenos should the user require
the activation/deactivation of this function), activation/deactivation code (parameter
supplied by Elenos to be entered for the function activation/deactivation), function status, work days in good operating conditions, work days in critical operating conditions.
The algorithm considers the following parameters to define the critical days: RF temperature, power supply temperature, ambient temperature and reflected power with
respect to maximum operating power.
These parameters must exceed the threshold values for a certain amount of time.
In this way, the duration and intensity of the event is assessed: intense short events are
heavy; less intense but longer events are heavy too.
3.1.2.20 GSM and modem service
Setting and display screen.
The GSM signal field intensity can be monitored.
It is possible to enable the submission of an alarm by SMS and/or PSTN in case of no
mains power (No Mains SMS) for the period of time set (Delay).
It is possible to enable the submission of an alarm by SMS and/or PSTN if the power delivered is at least 3dB less than the target set (SMS FWD over 2/3).
The codes to be displayed in the different message strings can be defined (PagerId,
StatId, String Id).
76Use instructions
Page 77
3.1.2.21 Phone N.1 to 4 / N.5 to 8
Setting and display screen.
The equipment can “communicate” with up to 8 SIM cards.
The telephone numbers and authorizations can be defined in international format
The number can be globally enabled for SMS transmission and reception SMS (En.), be
enabled to send commands (Cmd), be enabled to request and receive the machine status (Sts), be enabled to receive the echo any of commands sent by other numbers (Glb)
and be enabled to receive SMSs in text or digital format (PC.).
3.1.2.22 Uart 0,1 info
Control menu for testing the serial ports.
3.1.2.23 SMS Diagnostic
To see the number of SMS sent and received successfully.
For more detail see paragraph “SMS List”.
77Use instructions
Page 78
3.1.3 Exciter user interface
For further information, please consult the specific manual for the exciter.
78Use instructions
Page 79
3.2 Alarms/events list
There is an “Alarm management” module.
In order to check the alarm conditions, physical and logical digital inputs are used.
The status of each input is sampled and the condition is then logically processed by a
combinational network so as to establish whether the alarm or signalling is active.
The minimum intervention time is 100ms.
This module is repeatedly performed with the same priority as ALC management, so
as to constantly monitor the alarm cause onset and therefore to intervene within the
required time frame.
A log stores the sequence of the last events generating alarms with the date and time
of activation.
3.2.1 Control unit alarms/events list
Alarm/eventDescription
“000 CORRECT WORKING”
“001 SYSTEM RESET”
“002 EEPROM CHKSUM ERROR”
“003 BLOCKED”
“004 STOP”
“005 -3dB CARRIER”
“006 HIGH REF PWR”
“007 RF THERMAL DERATING”
“008 RF OVER TEMPERATURE”
“009 EXTERNAL INTERLOCK”
“010 ON AIR”
“011 POWER UP”
“012 POWER DOWN”
“013 EXCITER EXCHANGE”
“014 EXCITER SYNC COAX”
“015 INCORRECT COAX WORK”
“016 ON LOCAL SLAVE AMPLIFIER”
This indicates correct equipment operation.
The “On air” event has higher priority.
This indicates that the alarm reset is in
progress. All stored and inactive alarms are
removed from the list.
This indicates that the stored data is not reliable any longer and the machine is reconfigured according to the default parameters.
This indicates that the machine is blocked
after making 5 restore attempts. the user
must reset in order to allow the equipment to
restart.
This indicates that the equipment is in standby mode and is ready to start without alarms.
This indicates that the equipment has been
delivering power at least 3dB less than the
target set, for at least a minute in start-up and
5 seconds of normal operation.
This indicates that the level of reflected
output power is too high, meaning that the
equipment will turn off in three block out.
This indicates a too hot temperature on amplifiers, which implies a reduction in maximum
power output.
This indicates a maximum operating temperature overcoming for RF amplifier stage,
resulting in shutdown of the machine in three
blocks out. This protection occurs in extreme
cases where the mechanism Derating was
not enough to return to normal temperature
values.
This indicates that interlock is active.
This indicates that the device is functioning
properly and is being transmitted.
This indicates that is being inserted in the
storage an alert regarding the restart of the
device.
This indicates that is being inserted in the
storage an alert regarding the shutdown of
the equipment.
This indicates that there was an exchange of
the exciter.
This indicates that an assessment of relay
position was made.
This indicates that there is a relay problem.
This indicates that one or more amplifiers are
This indicates that one or more amplifiers
have communication problem.
This indicates that exciter 1 is fault.
This indicates that exciter 2 is fault.
This indicates that UPS is active.
This indicates an interlock signals hardware
failure.
This indicates that both exciters are fault.
This indicates the machine operation in a
combined system.
This indicates a deviation from the conditions
to set by user in relation to environment temperature measured from the apparatus.
This indicates a deviation from the conditions
to set by user in relation to RF modules temperature.
This indicates a deviation from the conditions
to set by user in relation to forward power.
This indicates a deviation from the conditions
to set by user in relation to reflected power.
This indicates the absence of the audio signal.
This indicates that amplifier n.1 have commu-
nication problem.
This indicates that amplifier n.2 have commu-
nication problem.
This indicates that amplifier n.3 have commu-
nication problem.
This indicates that amplifier n.4 have commu-
nication problem.
This indicates that amplifier n.5 have commu-
nication problem.
This indicates that amplifier n.6 have commu-
nication problem.
This indicates that exciter n.1 have communi-
cation problem/not used the correct driver.
This indicates that exciter n.2 have communi-
cation problem/not used the correct driver.
This indicates that the exciter is in LOCAL
mode.
This indicates that the machine is having a
power reduction since the reflected power
detected is too high.
80
3.2.2 Amplifier alarms/events list
Allarme/eventoDescrizione
“AMP_000 CORRECT WORKING”
“AMP_001 SYSTEM RESET”
“AMP_002 EEPROM CHKSUM ERROR”
“AMP_003 BLOCKED”
“AMP_004 STOP”
Use instructions
This indicates correct equipment operation.
The “On air” event has higher priority.
This indicates that the alarm reset is in
progress. All stored and inactive alarms are
removed from the list.
This indicates that the stored data is not reliable any longer and the machine is reconfigured according to the default parameters.
This indicates that the machine is blocked
after making 5 restore attempts. the user
must reset in order to allow the equipment to
restart.
This indicates that the equipment is in standby mode and is ready to start without alarms.
This indicates that the equipment has been
delivering power at least 3dB less than the
target set, for at least a minute in start-up and
5 seconds of normal operation.
This indicates that the level of reflected
output power is too high, meaning that the
equipment will turn off in three block out.
This indicates that the negative voltage reference is altered and prevents correct operation
of the protections. Stop in three block out.
This indicates a fault on one or more RF .
This indicates a fault on one or more RF mo-
dules,
which implies a reduction in the overall maximum deliverable power.
This indicates an excessive temperature on
the RF modules which implies a reduction in
the maximum output power.
This indicates that the maximum operating
temperature has been exceeded, thus causing
machine turn off in three block out. This protection intervenes in extreme cases in which
the Derating mechanism is not sufficient to
make the temperature values go back to
normal.
This indicates the malfunctioning of
the power supply(ies).
This indicates power supply overload which
causes a decrease in the power delivered.
This indicates that the machine switches off if
1 minute after derating the current still does
not decrease.
This indicates power supply overheating
which causes a decrease in the power delivered.
This indicates power supply overheating
which causes the equipment to switch off.
This indicates malfunctioning of the IEEE485
internal bus for communication between CPU,
PSU and SHUNT.
This indicates the presence of the active
interlock.
This indicates that the device is working properly and is transmitting.
This indicates that the equipment restart
signalling is being added to the log.
This indicates that the equipment switch off
signalling is being added to the log.
This indicates power supply overheating with
subsequent switching off of the machine. For
ELENOS equipment with more than one power
supply, the intervention of this protection
aims to allow operation at reduced power,
should a power supply be disconnected to
protect the hardware from excessive temperature.
This indicates a power drop with subsequent
switching off of the equipment. For ELENOS
equipment with more than one power supply,
the intervention of this protection aims to
allow operation at reduced power, should a
power supply be disconnected to protect the
hardware from a power decrease.
This indicates a problem on 50V with subsequent switching off of the machine. For ELENOS equipment with more than one
power supply, the intervention of this protection aims to allow operation at reduced
power, should a power supply
be disconnected to protect the hardware from
the absence of RF power.
This indicates the operation of the machine in
a combined system.
Use instructions
81
Page 82
“AMP_026 SWR FOLDBACK”
“AMP_030 OVER 2/3 CARRIER”
“AMP_031 PREAMPLIFIER NOT CONNECTED”
“AMP_032 OVER MODULATION”
“AMP_033 FAST INHIBIT”
“AMP_034 TEMPERATURE SENSOR ERROR”
“AMP_035 PWR FORWARD OSCILLATION”
“AMP_036 THREE BLOCK OUT”
“AMP_037 USER ENV TEMP OUT LIMIT”
“AMP_038 USER RF TEMP OUT LIMIT”
“AMP_039 USER PSU TEMP OUT LIMIT”
“AMP_040 USER RF CURRENT OUT LIMIT”
“AMP_041 USER PSU CURRENT OUT LIMIT”
“AMP_042 USER FRW PWR OUT LIMIT”
“AMP_043 USER RFL PWR OUT LIMIT”
“AMP_044 OUT PWR NOT VERIFIED”
“AMP_045 UPS ACTIVE”
“AMP_046 SHUNT COMM TIMEOUT”
“AMP_047 WARNING TEMPERATURE SENSOR”
“AMP_049 DRAIN VOLTAGE FEEDBACK ERROR”
“AMP_050 OVER FRW PWR ERROR”
“AMP_051 PILOT PWR GOOD”
“AMP_052 INCREASE PILOT PWR”
“AMP_053 DECREASE PILOT PWR”
“AMP_058 RTC FAULT”
This indicates that the machine is having a
power reduction since the reflected power
detected is too high.
This indicates that 2/3 of the power set has
been exceeded.
This indicates 100% reflected power. Not
implemented here.
This indicates over modulation.
This indicates that there are problems on the
hardware lines leading to RF delivery inhibition.
Where there are multiple RF temperature
probes, this indicates that one is faulty if it
measures a noticeably different value from
the other probes.
This indicates oscillations in the output power.
This indicates that restore procedure.
This indicates a variation with respect to
the conditions set by the user relating to
the ambient temperature measured by the
equipment.
This indicates a variation with respect to the
conditions set by the user relating to the RF
module temperature.
This indicates a variation with respect to the
conditions set by the user relating to the
power supply temperature.
This indicates a variation with respect to the
conditions set by the user relating to the RF
module currents.
This indicates a variation with respect to the
conditions set by the user relating to the
power supply current.
This indicates a variation with respect to the
conditions set by the user relating to the
direct power.
This indicates a variation with respect to the
conditions set by the user relating to the
reflected power.
This indicates that the output power cannot
be detected properly.
This indicates that the UPS is active, therefore
the equipment is using the target power set
for operation in this mode.
This indicates the communication timeout
on the polarizer. It stops the operation of the
apparatus.
This indicates a fault in the temperature
probes.
This indicates the lack of control of Vds for
causes such as power failures, wrong feeding,
etc..
This indicates the presence of overshoot in
power.
This indicates that the driving power is correct
and the driver enabled.
This indicates that the driving power is in the
range below, but close to the range of proper
operation, and the driver is enabled. It is necessary to a slight increase of the same.
This indicates that the driving power is in the
range top, but close to the range of proper
operation, and the driver is enabled. It is necessary to a slight decrease of the same.
This indicates that there were 3 consecutive
mismatches between date/time hardware
and firmware, or the date is formatted incorrectly.
82Use instructions
Page 83
“AMP_059 RTC USER UPDATED”
“AMP_060 RTC AUTOMATIC RECOVERY”
This indicates a date updates.
This indicates that there is a misalignment
of more than 5 seconds between the time /
date hardware and firmware.
3.2.3 Exciter alarms/events list
For further information, please consult the specific manual for the exciter.
83Use instructions
Page 84
3.3 SMS list
3.3.1 SMS commands (submit)
It is possible to submit SMSs in order to perform the following commands:
CommandSMS text
Power setting to xxxxx
Stand-by setting
Stand-by setting
On Air setting
Status demand
Reset demand
Exciter 1 On air
Exciter 2 On air
The number that sends this SMS will be
disabled upon receipt alarm/status
The “n” number will be disabled upon
receipt alarm/status
The “n” number will be enabled upon
receipt alarm/status
PWR xxxxx
STBY
OFF
ON
STS
RES
EXC1
EXC2
SMSNO
SMSNO n
SMSYES n
3.3.2 Status/alarm SMS (reception)
It is possible to receive status or alarm SMSs, for example composed in this way:
Exxxx ID xx
SMS String
+39xxxxxxxxxx
STBY
No mains xx m
xxx Messaggio di segnalazione
FWD yyyyy W
REFL yyyyy W
UMB PWR yyyyy W
TEMPMAX yyyyy F/C DUMMY LOAD
TEMPENV yyyyy F/C
Exc. x
Exxxx ID xx
SMS String
+39xxxxxxxxxx
-3dB Alarm
No mains xx m
xxx Messaggio di segnalazione
FWD yyyyy W
REFL yyyyy W
UMB PWR yyyyy W
TEMPMAX yyyyy F/C DUMMY LOAD
TEMPENV yyyyy F/C
Exc. x
Exxxx ID xx
SMS String
+39xxxxxxxxxx
Status
No mains xx m
xxx Messaggio di segnalazione
FWD yyyyy W
REFL yyyyy W
UMB PWR yyyyy W
TEMPMAX yyyyy F/C DUMMY LOAD
TEMPENV yyyyy F/C
Exc. x
84Use instructions
Page 85
Exxxx ID xx
SMS String
+39xxxxxxxxxx
Command
No mains xx m
xxx Messaggio di segnalazione
FWD yyyyy W
REFL yyyyy W
UMB PWR yyyyy W
TEMPMAX yyyyy F/C DUMMY LOAD
TEMPENV yyyyy F/C
Exc. x
Exxxx ID xx
SMS String
+39xxxxxxxxxx
RedPwr
No mains xx m
xxx Messaggio di segnalazione
FWD yyyyy W
REFL yyyyy W
UMB PWR yyyyy W
TEMPMAX yyyyy F/C DUMMY LOAD
TEMPENV yyyyy F/C
Exc. x
Exxxx ID xx
SMS String
+39xxxxxxxxxx
Exc.Exchange
No mains xx m
xxx Messaggio di segnalazione
FWD yyyyy W
REFL yyyyy W
UMB PWR yyyyy W
TEMPMAX yyyyy F/C DUMMY LOAD
TEMPENV yyyyy F/C
Exc. x
Where :
Exxxx ID xx is the description of the apparatus with indication of the ID number
SMS String is a customizable string of 10 characters
+39xxxxxxxxxx is the telephone number of origin of the last command
STBY indicates that the machine is in Standby (Off)
-3dB Alarm indicates that the machine is working below the-3dB
Status is the response to an SMS status command
Command is the confirmation to a command
RedPwr indicates that the machine is working in power limitation due to the UPS
Exc.Exchange indicates that there was an exchange between the exciters (Dual Drivers)
No mains xx m indicates that the machine has been off for the indicated time (in minutes)
xxx Messaggio di segnalazione indicates a cause of arrest or a major signaling
FWD yyyyy W indicates the forward power
REFL yyyyy W indicates the reflected power
UMB PWR yyyyy W indicates the power imbalance
TEMPMAX yyyyy F/C DUMMY LOAD indicates the temperature of the load
TEMPENV yyyyy F/C indicates the environment temperature
Exc. x indicates the exciters state (EXC.1, EXC.2, EXC.FAULT)
Please note: The functionality of the SMS reception is interrupted for an hour, if they are sent by
the system more than 5 messages over 5 min.
85Use instructions
Page 86
3.4 Externally connectable optional equipment
The equipment can be connected externally to the following units:
• PC
• Telemetry
• Exchange and/or Audio matrix
• Elenos E.BOX. module
3.4.1 Connection to PC
This connection is useful to analyse the equipment operating parameters in detail, for
example during the performance assessment stage or during repairs.
To PC connection an interface must be inserted into the “Interface” connector, DB9,
on the front panel of amplifiers and combiner; and add an other cable (ELENOS code
CAB0068-0) to insert to PC.
This may be supplied with the product.
The connection can also be made when the machine is operating.
The Windows Hyperterminal programme can be used to display, or another equivalent
available programme.
For the detailed procedure for using an ASCII terminal, please request technical bulletin
No. 127 from the manufacturer.
CAB0068-0
86
Use instructions
Page 87
3.4.1.1 Control unit hyperterminal interface
The Hyperterminal pages have a very similar structure to the display view, hence they
will not be further described herein.
Since there is more available space, there could be additional parameters.
Main Menu
Main Menù
Main RF Data (M)
Use instructions
87
Page 88
Main Menù
Profiles (O)
Main Menù
Temperatures (T)
88
Main Menù
Password (K)
Use instructions
Page 89
Main Menù
Events/Status (S)
Main Menù
Events History (H)
Use instructions
Main Menù
Clock Power Set (C)
89
Page 90
Main Menù
SMS Phone Set (P)
Main Menù
System Settings (X)
Main Menù
Password Reset (Z)
90
Use instructions
Page 91
Main Menù
Dual Drive (D)
Main Menù
RF Mode Menù (E)
Use instructions
Main Menù
RF Mode Menù (E)
Amplifiers Status (S)
91
Page 92
Main Menù
RF Mode Menù (E)
Amplifiers Data (W)
Main Menù
RF Mode Menù (E)
Amplifiers Data 2 (V)
Main Menù
RF Mode Menù (E)
Exciters Data (T)
92
Use instructions
Page 93
Main Menù
RF Mode Menù (E)
Amplifier 1...6 Data
(A,C,E,G,I,K)
Main Menù
RF Mode Menù (E)
Amplifier 1...6 Modules
(B,D,F,H,J,L)
Use instructions
Main Menù
RF Mode Menù (E)
Exciter 1...2 data (M,N)
93
Page 94
Main Menù
Status (W)
Main Menù
User Warning (F)
Main Menù
Enable Alarms (V)
94
Use instructions
Page 95
3.4.1.2 Amplifier hyperterminal interface
Main Menu
Main Menù
Main RF Data (M)
Use instructions
95
Page 96
Main Menù
Status/Alarms (S)
Main Menù
Events History (H)
96
Main Menù
Password (K)
Use instructions
Page 97
Main Menù
Password (K)
Password (K)
Main Menù
Password (K)
Password reset (R)
Use instructions
Main Menù
Password (K)
Password settings (P)
97
Page 98
Main Menù
System (Y)
Main Menù
System (Y)
System settings (X)
Main Menù
System (Y)
Clock power set (C)
98
Use instructions
Page 99
Main Menù
System (Y)
SMS phone set (P)
Main Menù
System (Y)
User warning (F)
Use instructions
Main Menù
System (Y)
En. 0-31 alrm SMS (V)
99
Page 100
Main Menù
System (Y)
En. 32-63 alrm SMS (B)
Main Menù
System (Y)
Lifextender (L)
100
Main Menù
Debug (D)
Use instructions