Electro-Voice N/D267, N/D267S Quick Start Manual

N/D267 N/D267S
N/DYM® Dynamic Cardioid Performance Microphones
• Cardioid polar pattern for superior feedback rejection and acoustic isolation
• Large diaphragm for extended frequency response
• Superior multistage shock mount for unmatched low handling noise
• Handles high SPL's without distortion
• “On/Off” switch (N/D267S)
Description
The Electro-Voice N/D267, part of a new generation of N/DYM signed for high-quality vocal use in live­sound and home-recording situations. The N/D267 is a member of a family of micro­phones that are manufactured with refine­ments that enhance sonic smoothness, im­prove gain-before-feedback, and provide more consistent performance with greater durability than earlier generations of N/DYM acoustic response is tuned to achieve an ex­tended frequency range with improved tran­sient response, presenting clear lead and background vocals without the need for ex­cessive equalization. Where exceptional vocal clarity is desired, the N/D267 is the microphone of choice.
As in all N/DYM features EV’s outstanding neodymium-iron­boron magnetic structure to provide greater sensitivity and an exceptional signal-to-noise ratio. In addition, the N/DYM ometry, combined with a lar ge reinforced dia­phragm design, produces a smooth, extended frequency response with a warm, open and transparent sound quality normally found only in studio-quality microphones.
®
microphones. The N/D267’s
®
microphones, is de-
®
microphones, the N/D267
®
magnet ge-
N/DYM AcoustiDYM™ shock-mount system. This unique vibration isolating system works as a multistage device. At low frequencies, a rear sound wave cancels the diaphragm motion while, at high frequencies, the specially
designed rubber shock mount isolates the transducer from motion. Combining AcoustiDYM™ with the elastomeric W arm­Grip™ handle and the windscreen bumper produces an advanced technology, vibration isolating system which dramatically reduces all forms of handling noise for the most de­manding situations.
The N/D267 employs a cardioid polar pat­tern, providing enhanced front-area sensitiv­ity and accoustic rejection directly behind the microphone, reducing feedback under live performance conditions. This is particu­larly useful with typical monitor speaker placement and high sound pressure level (SPL) requirements. Additionally, the N/D267’s polar patterns are unusually uni­form with frequency, ensuring superior gain­before-feedback in live applications and su­perior isolation when used in the studio.
The N/D267 pop filter’s unique design uti­lizes a specially processed Acoustifoam ter to minimize wind noise and vocal P-pops.
®
microphones feature EV's
TM
fil-
This design makes the pop filter an integral part of the microphone’s removable front grille assembly, allowing easy cleaning for continued top performance. The N/D267S has the added feature of an easily accessible “on/off” switch.
Operation
The N/D267’s low-frequency response var­ies with the distance of the sound source to the microphone. This is known as “proxim­ity effect.” Maximum bass response is pro­duced in close-up use with the microphone 1/4 inch from the sound source. Minimal bass response is experienced at distances greater than 24 inches. By working closer to the microphone, the human voice will sound more robust. W orking the microphone close-up will also reduce the potential for feedback from a P A sound system. This ben­efit is in addition to the feedback-reducing cardioid polar pattern. When close-talked, the substantial bass boost provides an in­crease in overall microphone output level. The mixer gain may be proportionately reduced, resulting in a reduction of the system’s sensitivity to feedback caused by sound entering the microphone from the loudspeakers.
N/D267 and N/D267S Cardioid Performance Vocal Microphones
The dynamic element of the N/D267 will provide reliable operation in extreme tem­perature, humidity and other adverse condi­tions that would render typical condenser mi­crophones useless. These N/D267 features will provide years of trouble-free operation.
Certified Performance
Every N/D267 is inspected by a quality control tester and subjected to a computer­controlled test system that verifies numer­ous performance parameters. After the perfor­mance meets or exceeds our rigorous stan­dards, the actual measured frequency re­sponse is plotted on a "Certificate of Per­formance" and included with the microphone. Certified performance may vary from pub­lished "A verage Response." This certificate guaranties that each N/D267 will perform to exacting standards of the 100% qual- ity assurance testing, established by EV's design engineers.
Limited Warranty
Electro-Voice products are guaranteed against malfunction due to defects in ma­terials or workmanship for a specified period, as noted in the individual product­line statement(s) below, or in the individual
N/D267 and N/D267S Cardioid Performance Vocal Microphones
product data sheet or owner’s manual, beginning with the date of original pur­chase. If such malfunction occurs during the specified period, the product will be
repaired or replaced (at our option) with­out charge. The product will be returned to the customer prepaid. Exclusions and Limitations: The Limited Warranty does not apply to: (a) exterior finish or appear­ance; (b) certain specific items described in the individual product-line statement(s) below, or in the individual product data sheet or owner’s manual; (c) malfunction resulting from use or operation of the prod­uct other than as specified in the product data sheet or owner’s manual; (d) mal­function resulting from misuse or abuse of the product; or (e) malfunction occurring at any time after repairs have been made to the product by anyone other than EVI Audio Service or any of its authorized service representatives. Obtaining Warranty Ser- vice: To obtain warranty service, a customer must deliver the product, pre­paid, to EVI Audio Service or any of its authorized service representatives together with proof of purchase of the product in the form of a bill of sale or receipted invoice. A list of authorized service repre­sentatives is available from EVI Audio Service at 600 Cecil Street, Buchanan, MI 49107 (800/685-2606 or FAX 616/695-4743). Incidental and Conse- quential Damages Excluded: Product repair or replacement and return to the customer are the only remedies provided to the cus­tomer. Electro-Voice shall not be liable for any incidental or consequential damages including, without limitation, injury to per-
sons or property or loss of use. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. Other Rights: This war- ranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Electro-Voice Wired Microphones are guaranteed against malfunction from any cause for two (2) years from the date of original purchase. In addition, the Limited Warranty for the acoustic system con­tained in these microphones shall apply for the life of the product, defined as a period of ten (10) years from the date that the manufacture of the specific micro­phone has been discontinued. Any and all active electronics incorporated in these microphones are guaranteed against mal­function due to defects in materials or workmanship for a period of three (3) years from the date of original purchase. The Limited Warranty does not extend to cables, cable connectors, or switches. Ad­ditional details are included in the Uniform Limited Warranty statement.
For technical assistance, contact Techni­cal Support at 800/234-6831 or 616/695-6831, M-F, 8:00 a.m. to 5:00 p.m. Eastern Standard time.
Specifications subject to change without notice.
2
Loading...
+ 2 hidden pages