N/D267
N/D267S
N/DYM® Dynamic
Cardioid Performance
Microphones
• Cardioid polar pattern for superior
feedback rejection and acoustic
isolation
• Large diaphragm for extended
frequency response
• Superior multistage shock mount
for unmatched low handling noise
• Handles high SPL's without
distortion
• “On/Off” switch (N/D267S)
Description
The Electro-Voice N/D267, part of a new
generation of N/DYM
signed for high-quality vocal use in livesound and home-recording situations. The
N/D267 is a member of a family of microphones that are manufactured with refinements that enhance sonic smoothness, improve gain-before-feedback, and provide
more consistent performance with greater
durability than earlier generations of
N/DYM
acoustic response is tuned to achieve an extended frequency range with improved transient response, presenting clear lead and
background vocals without the need for excessive equalization. Where exceptional
vocal clarity is desired, the N/D267 is the
microphone of choice.
As in all N/DYM
features EV’s outstanding neodymium-ironboron magnetic structure to provide greater
sensitivity and an exceptional signal-to-noise
ratio. In addition, the N/DYM
ometry, combined with a lar ge reinforced diaphragm design, produces a smooth, extended
frequency response with a warm, open and
transparent sound quality normally found only
in studio-quality microphones.
®
microphones. The N/D267’s
®
microphones, is de-
®
microphones, the N/D267
®
magnet ge-
N/DYM
AcoustiDYM™ shock-mount system. This
unique vibration isolating system works as a
multistage device. At low frequencies, a rear
sound wave cancels the diaphragm motion
while, at high frequencies, the specially
designed rubber shock mount isolates
the transducer from motion. Combining
AcoustiDYM™ with the elastomeric W armGrip™ handle and the windscreen bumper
produces an advanced technology, vibration
isolating system which dramatically reduces
all forms of handling noise for the most demanding situations.
The N/D267 employs a cardioid polar pattern, providing enhanced front-area sensitivity and accoustic rejection directly behind
the microphone, reducing feedback under
live performance conditions. This is particularly useful with typical monitor speaker
placement and high sound pressure level
(SPL) requirements. Additionally, the
N/D267’s polar patterns are unusually uniform with frequency, ensuring superior gainbefore-feedback in live applications and superior isolation when used in the studio.
The N/D267 pop filter’s unique design utilizes a specially processed Acoustifoam
ter to minimize wind noise and vocal P-pops.
®
microphones feature EV's
TM
fil-
This design makes the pop filter an integral
part of the microphone’s removable front
grille assembly, allowing easy cleaning for
continued top performance. The N/D267S
has the added feature of an easily accessible
“on/off” switch.
Operation
The N/D267’s low-frequency response varies with the distance of the sound source to
the microphone. This is known as “proximity effect.” Maximum bass response is produced in close-up use with the microphone
1/4 inch from the sound source. Minimal
bass response is experienced at distances
greater than 24 inches. By working closer
to the microphone, the human voice will
sound more robust. W orking the microphone
close-up will also reduce the potential for
feedback from a P A sound system. This benefit is in addition to the feedback-reducing
cardioid polar pattern. When close-talked,
the substantial bass boost provides an increase in overall microphone output level.
The mixer gain may be proportionately
reduced, resulting in a reduction of the
system’s sensitivity to feedback caused by
sound entering the microphone from the
loudspeakers.

N/D267 and N/D267S Cardioid Performance Vocal Microphones
The dynamic element of the N/D267 will
provide reliable operation in extreme temperature, humidity and other adverse conditions that would render typical condenser microphones useless. These N/D267 features
will provide years of trouble-free operation.
Certified Performance
Every N/D267 is inspected by a quality
control tester and subjected to a computercontrolled test system that verifies numerous performance parameters. After the performance meets or exceeds our rigorous standards, the actual measured frequency response is plotted on a "Certificate of Performance" and included with the microphone.
Certified performance may vary from published "A verage Response." This certificate
guaranties that each N/D267 will perform
to exacting standards of the 100% qual-
ity assurance testing, established by EV's
design engineers.
Limited Warranty
Electro-Voice products are guaranteed
against malfunction due to defects in materials or workmanship for a specified
period, as noted in the individual productline statement(s) below, or in the individual
N/D267 and N/D267S Cardioid Performance Vocal Microphones
product data sheet or owner’s manual,
beginning with the date of original purchase. If such malfunction occurs during
the specified period, the product will be
repaired or replaced (at our option) without charge. The product will be returned to
the customer prepaid. Exclusions and
Limitations: The Limited Warranty does
not apply to: (a) exterior finish or appearance; (b) certain specific items described
in the individual product-line statement(s)
below, or in the individual product data
sheet or owner’s manual; (c) malfunction
resulting from use or operation of the product other than as specified in the product
data sheet or owner’s manual; (d) malfunction resulting from misuse or abuse of
the product; or (e) malfunction occurring
at any time after repairs have been made to
the product by anyone other than EVI Audio
Service or any of its authorized service
representatives. Obtaining Warranty Ser-
vice: To obtain warranty service, a
customer must deliver the product, prepaid, to EVI Audio Service or any of its
authorized service representatives together
with proof of purchase of the product in
the form of a bill of sale or receipted
invoice. A list of authorized service representatives is available from EVI Audio
Service at 600 Cecil Street, Buchanan, MI
49107 (800/685-2606 or FAX
616/695-4743). Incidental and Conse-
quential Damages Excluded: Product repair
or replacement and return to the customer
are the only remedies provided to the customer. Electro-Voice shall not be liable for
any incidental or consequential damages
including, without limitation, injury to per-
sons or property or loss of use. Some states
do not allow the exclusion or limitation of
incidental or consequential damages so
the above limitation or exclusion may not
apply to you. Other Rights: This war-
ranty gives you specific legal rights, and
you may also have other rights which vary
from state to state.
Electro-Voice Wired Microphones are
guaranteed against malfunction from any
cause for two (2) years from the date of
original purchase. In addition, the Limited
Warranty for the acoustic system contained in these microphones shall apply
for the life of the product, defined as a
period of ten (10) years from the date that
the manufacture of the specific microphone has been discontinued. Any and all
active electronics incorporated in these
microphones are guaranteed against malfunction due to defects in materials or
workmanship for a period of three (3)
years from the date of original purchase.
The Limited Warranty does not extend to
cables, cable connectors, or switches. Additional details are included in the Uniform
Limited Warranty statement.
For technical assistance, contact Technical Support at 800/234-6831 or
616/695-6831, M-F, 8:00 a.m. to 5:00 p.m.
Eastern Standard time.
Specifications subject to change without
notice.
2