* MSD MEDIA MONITOR ** MSD MEDIA MONITOR *
For Grit Blast Cleaning/Aircraft Paint Stripping
S:\COREL\DRAW\DATASHT\MSD1.CDR 12/17/2002
* Independently Adjustable
High and Low Alarms
* Bar Graph Display
* Excitation Output for Nozzle
Sensor
* 0-5Vdc Input Range
The Model MSD abrasive blast cleaning and aircraft paint stripping Media
Flow Monitor is designed for use in all types of ( ferrous and non-ferrous )
peening applications to display media flow rate. The high and low
independently adjustable alarm points can be used to signal unusual flow
conditions and is especially useful in indicating clogged feed valves or low
abrasive media supply.
CAUTION: This product has been designed to measure media density at the nozzle. For
proper control, system air pressure must also be monitored.
ELECTRONICS INCORPORATEDELECTRONICS INCORPORATED
SHOT PEENING TECHNOLOGY
* MODEL MSD MEDIA MONITOR ** MODEL MSD MEDIA MONITOR *
S:\COREL\DRAW\DATASHT\MSD1.CDR 7/29/99
135.9mm
67.1mm
PANEL
CUTOUT
144mm
72.1mm
228.6mm
MOUNTING INSTRUCTIONS
PANEL CUT-OUT IS 5.35“ X 2.64” ( 135mm X 67mm )
PANEL CUT-OUT
TOP RAIL
6-32 SET SCREWS
ALLEN HEAD
SCREWDRIVER
All adjustments available
All adjustments available
behind front panel access plate
behind
front panel access plate
Wiring ConnectionsWiring Connections
1. Power Neutral (120Vac)
1. Power Neutral (120Vac)
2. Power Hot (120Vac)
Power Hot (120Vac)
2.
3. Enable Input (120Vac)
3.
Enable Input (120Vac)
4. Earth Ground
4.
Earth Ground
5
5
High Alarm Relay Contact
. High Alarm Relay Contact
.
6.
High Alarm Relay Contact
6. High Alarm Relay Contact
7.
Low Alarm Relay Contact
7. Low Alarm Relay Contact
8.
8. Low Alarm Relay Contact
Low Alarm Relay Contact
9. Alarm Reset (120Vac)
9. Alarm
11. (+) 12Vdc Excitation Output
11.
12. (-) 12Vdc Excitation Output
12.
13. (+) 5vdc Reference
13.
14. 0-5 Vdc Input
14.
15. 0 Vdc
15.
16. Sensor Shield
16.
19. 0 Vdc
19.
20. Recorder Output (0-10Vdc)
20.
Reset (120Vac)
(+) 12Vdc Excitation Output
(-) 12Vdc Excitation Output
(+) 5vdc Reference
0-5 Vdc Input
0 Vdc
Sensor Shield
0 Vdc
Recorder Output (0-10Vdc)
NOTE:
NOTE:
Green screw for
Green screw for
earth-chassis ground
earth-chassis
used for shield termination.
used for shield termination.
WARNING: DO NOT REMOVE
FACE PLATE OR BEZEL
EA0501Z.CDR 2-6-98
Note: All views shown with front access plate removed
ground
BOTTOM RAIL
NOTE: CONNECTORS ARE
REMOVABLE FOR SERVICE
MOUNTING STEPS
1. REMOVE TOP AND BOTTOM SLIDE RAILS FROM UNIT
2. SLIDE CONTROLLER INTO PANEL FROM FRONT
3. SLIDE RAILS BACK INTO CONTROLLER AND TIGHTEN
USING SET SCREWS.
Specifications
Power: 120Vac, 50/60 Hertz, 50VA
Power: 120Vac, 50/60 Hertz, 50VA
Inputs:
Inputs:
Media
Media Sensor:
Enable:
Enable: 90 - 120Vac
Alarm
Alarm Reset: 90-120Vac
Outputs:
Outputs:
Recorder
Recorder output: 0-10Vdc Analog Voltage
Excitation
Excitation Voltage: +/- 12Vdc (100mA)
Weight:
Weight: 1.4 kg
Display:
Display: 20 Segment Bar Graph
Sensor:
90 - 120Vac
Reset: 90-120Vac
output: 0-10Vdc Analog Voltage
Contacts: Voltage free normally open contacts
Alarm
Alarm Contacts: Voltage free normally open contacts
at 120Vac @ 1Amp max
rated
rated at 120Vac @ 1Amp max
Voltage: +/- 12Vdc (100mA)
1.4 kg
20 Segment Bar Graph
- 5vdc Analog Voltage
0 - 5vdc Analog Voltage
0
830228.A
56790 Magnetic Drive Mishawaka, IN. USA 46545 (574) 256-500156790 Magnetic Drive Mishawaka, IN. USA 46545 (574) 256-5001