Electronics AC User Manual

AC Controller
MagnaValve® Motor Current Controller
Features
• Digital display
• High-low alarm contacts
• Accepts remote command setpoint
• Provides analog recorder output
• Easy panel mounting (1/2 DIN)
• 120 Vac
Description
The AC Controller provides automatic operation (a closed-loop system) for the MagnaValve®. The feedback from the controller allows the MagnaValve to regulate steel shot in shot peening and blast cleaning applications where accurate and repeatable ow rates are desired. The controller may operate as a stand-alone control or work with a customer’s programmable controller via standard analog 0-10 Vdc interface. Alarm contacts will notify of a high or low motor current outside of an adjustable bandwidth.
A clear and comprehensive installation manual simplies installation for the AC Controller and the product is supported by the Electronics Inc. application engineering sta.
Desired
Motor Current
AC
Control Signal
Controller
Regulated Media Flow
Motor
Current
Ammeter
The Closed Loop System
with the AC Controller and a MagnaValve
Available for download at www.electronics-inc.com
• VLP-1000 MagnaValve Data Sheet • 100 MagnaValve Data Sheet
• LP-2000 MagnaValve Data Sheet • AC Instruction Manual
Media
Hopper
MagnaValve
Wheel
Media Accelerated
Electronics Inc.
56790 Magnetic Drive
Mishawaka, Indiana 46545 USA
(574)256-5001
www.electronics-inc.com
Specication is subject to change without notice
MagnaValve is a registered trademark of Electronics Inc.
Rev 2/13
AC Controller
MagnaValve® Motor Current Controller
Specifications
Power
115 Vac, 50/60 Hertz, 50 VA
Inputs 0-5 Amps (From Wheel Motor) Remote Command Setpoint (0 -10Vdc) Enable (115Vac) Alarm Reset (115 Vac)
Outputs
Valve Power 50Vdc PWM at 8 Hertz Recorder Analog Output (0 -10Vdc) Alarm Relay Contacts (115Vac @ 1Amp) Max. Excitation Output Voltage ±12Vdc (100mA) Reference Output Voltage +10Vdc (10mA)
Dimensions
Specifications
Weight 5 lb / 2.27 Kg Display Range 0 -1999 Decimal Points 1999, 199.9, 19.9 Alarm Band 0 -50% of full scale Alarm Delay 0 -10 seconds Reset Delay 0 -10 seconds Auto-Zero ±20% of full scale Temperature Range 0 - 50˚C (32 - 122˚ F)
The AC Controller comes with a 0.05 Ohm current shunt for customer’s 0-5 Amp input signal. It is placed on screw terminals #16 and #18 for customer connection to wheel motor current transformer output leads.
2.84''
(72 mm)
5.67''
(144 mm)
Shown with front panel removed
Panel Cutout Dimensions:
2.64’’ W x 5.35’’ H (67 mm x 136 mm)
Standard DIN opening
9.0''
(229 mm)
Electronics Inc.
56790 Magnetic Drive
Mishawaka, Indiana 46545 USA
(574)256-5001
www.electronics-inc.com
Specication is subject to change without notice
MagnaValve is a registered trademark of Electronics Inc.
Rev 2/13
Loading...