Electronics 590 User Manual

120 Vac Series MagnaValve
Magnetic Media Valve for Air Blast Machines
Model Flow Rate Range
578 3 - 30 lbs/min (1- 10 kg/min) 579 10 - 100 lbs/min (5 - 50 kg/min) 580 20 - 200 lbs/min (10 - 100 kg/min)
590 30 - 300 lbs/min (15 - 150 kg/min)
Features
• ±10% full-scale accuracy*
• No moving parts
• Meets SAE AMS 2430 and 2432 specications
The 120 Vac MagnaValve (left) and FC Controller (right)
work together to provide accurate and repeatable
Description
The MagnaValve™ is a normally closed magnetic valve that regulates the ow of steel shot and cut wire media in air blast machines. The MagnaValve’s built-in sensor measures ow rate and, together with the FC Controller (sold separately), provides accurate and repeatable ow rates. The MagnaValve can be factory calibrated for various media types and sizes.
ferrous media ow rates.
The MagnaValve’s maintenance-free construction includes a strong and stable rare earth permanent magnet for normally closed operation and an electromagnet for controlling shot ow rates. When no power is applied to the MagnaValve, the permanent magnet stops all ow. With power applied, the magnetic eld is neutralized and shot is allowed to ow through the valve. If the power is interrupted for any reason, the permanent magnet in the valve securely holds the shot. The valve is factory calibrated and results are supplied upon request.
The MagnaValves provides reliable, repetitive, and consistent media ow rates for shot peening and blast cleaning applications. The MagnaValve makes it easy to document ow rates and establish or repeat a good set-up. The valve meets the requirements of SAE AMS 2430, AMS 2432 and other aerospace and commercial specications.
Clear and comprehensive installation manuals simplify installation for the 120 Vac Series MagnaValves and the FC Controller. In addition, the products are supported by the Electronics Inc. application engineering sta.
Note: The power input signal to this family of MagnaValves is 50 Vdc using PWM, Pulse Width Modulation, provided by the FC Controller which operates from 120 Vac mains. Also see the 24Vdc MagnaValves for low voltage installations.
*Higher accuracy available upon request FC Controller datasheet in PDF is available for download at www.electronics-inc.com MagnaValve is a trademark of Electronics Inc.
Electronics Inc.
56790 Magnetic Drive
Mishawaka, Indiana 46545 USA
(574)256-5001
www.electronics-inc.com
120 VacMagnaValveRev2 06/11
Specication is subject to change without notice
120 Vac Series MagnaValve
Valve Specications
Power from FC Controller ±12 Vdc @ 100 mA maximum Media All ferrous media except Cast Stainless Steel Maximum Pressure 100 PSI Mode Normally Closed Temperature Range 32 - 122º F (0 -50º C) Servo Command Input PWM 50 Vdc* 0 - 10 24 Vdc
FC Controller (sold separately)
Flow Sensor Input from MagnaValve 0 - 5 Vdc into 100K Flow Enable Input 120 Vac Servo Command Output PWM 50 Vdc* Remote Setpoint Input 0 - 10 Vdc
Flow Sensor Output 0 - 5 Vdc 0 - 10 Vdc
* PWM - Pulse Width Modulation 8 Hertz frequency with 0-100% duty cycle, 50Vdc power signal
Top View Side View
“A”
Magnetic Media Valve for Air Blast Machines
4.9’’
(124 mm)
“B’’
“E’’
“F’’ “G’’
“D’’
“C”
Model Number Pipe Size “A” “B” “C” “D” “E” “F” “G”
578 1.25 “ NPT 7.3” (185 mm) 3.5” (88.9 mm) 4.5” (114.3 mm) 2.0” (50.8 mm) 3.1” (78.8 mm) 3.0” (76.2 mm) 6.0” (152.4 mm)
579 1.25 “ NPT 7.3” (185 mm) 3.5” (88.9 mm) 4.5” (114.3 mm) 4.0” (101 mm) 3.1” (78.8 mm) 3.0” (76.2 mm) 8.0” (203.2mm)
580 2.0 “ NPT 8.4” (214 mm) 4.0” (101.6 mm) 5.5” (139.7 mm) 3.5” (88.9 mm) 3.5” (88.9 mm) 3.5” (88.9 mm) 8.0” (203.2mm)
590 2.0 “ NPT 8.4” (214 mm) 4.0” (101.6 mm) 5.5” (139.7 mm) 3.5” (88.9 mm) 3.5” (88.9 mm) 3.5” (88.9 mm) 8.0” (203.2mm)
Electronics Inc.
56790 Magnetic Drive
Mishawaka, Indiana 46545 USA
(574)256-5001
www.electronics-inc.com
120 VacMagnaValveRev2 06/11
Specication is subject to change without notice