Electronics 180-AC User Manual

*MODEL180MagnaValve*
SHOTPEENINGCONTROLTECHNOLOGY
Preliminary
*On-OffValve *Nomovingparts *Noaircylinders *Steelshot/grit *FailSafepermanent
Magnetconstruction
Thevalveconstructionincludesapermanentmagnetfornormallyclosed operationandanelectromagnettoactivateshotflow.Byapplyingpowertothe electromagnet,afullflowconditionmaybeachieved.Whenpowerisoff,the valvewillholdshotduetothepermanentmagnet.
ELECTRONICSINCORPORATED
*Normallyclosed *200lbs./min. *110Vacor *24Vdc
Model180DCCPN#999327 Model180ACCPN#999328
180_ac_dcDATA.CDR02/02/2004
*MODEL180MagnaValve*
Preliminary
SPECIFICATIONS
VALVE
Input:80-125VAC@2Aor
23-25Vdc@2A Output:200lbs./min. Media:Steelshot Mode:Normallyclosed Temp.Range:32-167°F
0-75° C
LED:Redforflow
5”
Note:TheMagnaValveisdesignedto operateinaverticalpositionandmust bemountedwithin5degreesofvertical.
Model180DCCPN#999327 Model180ACCPN#999328
56790MagneticDrive,Mishawaka,In.USA46545Phone(574)256-5001FAX1-574-256-5222
Loading...