Electrolux WT44BL208 Service Manual

Electrolux
CAUTION:
U
U
EFS - Dishwashing Systems Platform Electrolux Professional
RACK-TYPE DISHWASHERS
SERVICE MANUAL
MODULAR AND COMPACT
EDITION: 05.2007
Valid for firmware from 1.56 to 1.62
DOC. N. 5956.573.02 Page 1 / 80
All the safety regulations and procedures to be followed by the Specialised Technician/Technical Assist­ance performing electrical, mechanical or electronic maintenance operations are contained in the instruc­tion manual supplied with the machine: refer to this document before operating. This applies for anyone carrying out operations using these documents. The specialised technician must wear personal protec­tion equipment suitable for the work being performed (e.g. gloves, safety glasses and shoes, suitable clothing, etc.) and use appropriate tools, equipment and auxiliary means.
Electrolux
EFS - Dishwashing Systems Platform Electrolux Professional
INDEX
A FUNCTION KEYS............................................................................................. Page4
A1 DISPLAY OF AUXILIARY VALUES ................................................................................. Page4
A1.1 MODULAR MACHINES....................................................................................... Page4
A1.2 COMPACT MACHINES ....................................................................................... Page5
A2 ACCESSING THE USER MENU AND SERVICE MENU ................................................ Page6
A3 USER MENU (ONLY FOR MODULAR RACK TYPE) ..................................................... Page7
A3.1 EXIT .................................................................................................................... Page7
A3.2 DATA SETTING ................................................................................................... Page7
A4 SERVICE MENU ............................................................................................................. Page8
A4.1 PARAMETERS .................................................................................................... Page8
A4.1.1 USER SETTINGS (ONLY FOR MODULAR RACK TYPE)................ Page8
A4.1.2 GENERIC FUNC............................................................................... Page9
A4.1.3 RINSE MODULE............................................................................... Page15
A4.1.4 WASH MODULE ............................................................................... Page16
A4.1.5 PREWASH MODULE........................................................................ Page18
A4.1.6 DT MODULE ..................................................................................... Page19
A4.1.7 HACCP.............................................................................................. Page20
A4.1.8 RATING PLATE (ONLY FOR MODULAR RACK TYPE) ................... Page20
A4.2 DATALOG (ONLY FOR MODULAR RACK TYPE)............................................... Page22
A4.3 INFO.................................................................................................................... Page25
A4.4 STATISTICS (ONLY FOR MODULAR RACK TYPE)........................................... Page26
A4.5 RINSE CONTROL ( JUST FOR ATMOSPHERIC RACK TYPE )........................ Page27
A4.6 KEY MANAGEMENT ( JUST FOR MODULAR RACK TYPE ) ........................... Page28
A4.7 SENSOR ADJUSTMENT .................................................................................... Page28
B PROGRAMMING SHEETS............................................................................... Page30
B1 CONFIGURATION PARAMETERS ................................................................................. Page 30
B1.1 MODULAR RACK TYPE ..................................................................................... Page 30
B1.2 COMPACT RACK TYPE...................................................................................... Page 41
B1.3 COMPACT RACK TYPE USA ............................................................................. Page 53
B2 SPECIFIC FUNCTIONS .................................................................................................. Page 54
B2.1 SETTING UNIT OF MEASURE IN FAHRENHEIT .............................................. Page54
B2.2 LANGUAGE SETTING ........................................................................................ Page54
B2.3 “MAX. MOTOR CURR.” PARAMETER ( GCU ) SETTING .................................. Page54
C INVERTER PARAMETERS .............................................................................. Page55
C1 INVERTER PROGRAMMING.......................................................................................... Page 55
C1.1 DISPLAY FUNCTIONS........................................................................................ Page 55
C1.2 INVERTER PARAMETER LISTS ........................................................................ Page 55
D WARNING MESSAGES AND TROUBLESHOOTINGPage............................. 59
E POWER BOARDS CONNECTORS LAYOUTPage .......................................... 63
DOC. N. 5956.573.02 Page 2 / 80
Electrolux
EFS - Dishwashing Systems Platform Electrolux Professional
INDEX OF FIGURES AND TABLES
Figure 1 Menu access keysPage ........................................................................................................ 4
Figure 2 Accessing current, temperatures and levels display modePage........................................... 4
Figure 3 Accessing the USER MENUPage......................................................................................... 6
Figure 4 Accessing the SERVICE MENUPage................................................................................... 6
Figure 5 Parameter and function access menu chart for Modular Rack TypePage ............................ 6
Figure 6 Parameter and function access menu chart for Compact Rack TypePage........................... 6
Figure 7 Scheme for “Heat two comm.” parameter and “Heating manage” parameter (only for
Modular Rack Type)Page 13
Figura 8 Scheme for “H2C” parameter and “b_t” parameter (only for Compact Rack Type)Page ...... 13
Table 1 Machine codes list and relative programming sheetsPage................................................... 30
N.B. The vertical lines on the left of the text indicate additions with respect to the previous edition.
DOC. N. 5956.573.02 Page 3 / 80
Electrolux
U
U
U
EFS - Dishwashing Systems Platform Electrolux Professional
A FUNCTION KEYS
BUTTONS USED
A
A1 DISPLAY OF AUXILIARY VALUES
From the normal machine operation mode it is possible to see several screens not accessible to the user. These screens give various machine values, and are accessed by pressing at the same time the combinations of buttons displayed. (Figure 4).
B
Figure 1 Menu access keys
C
D
E
Figure 2 Accessing current, temperatures and levels display mode
A1.1 MODULAR MACHINES
Press the Speed1 - “E” (Figure 1) - and Increase buttons - “A” (Figure 1) - at the same time for a few seconds to access the screen displaying the levels of the various tanks and airgap.
Prewash 200 mmH2O
Wash 195 mmH2O
Airgap 60 mmH2O
DUO 55 mmH2O
DOC. N. 5956.573.02 Page 4 / 80
Press the Increase button - “A” (Figure 1) - to access the screen giving the current absorbed by the gear motor.
Electrolux
Adt tmp
68
1
DT temperature (significant only for machines with DT)
tAn LE
198
4
Wash tank level
sCp LE
204
5
Prewash tank level (significant only for machines with prewash)
Mot Cur
34
6
Gear motor current
EFS - Dishwashing Systems Platform Electrolux Professional
Mot. Curr. 35 decA
To return to the standard display, wait 30 seconds or press the Confirm button - “C” (Figure 1) -.
A1.2 COMPACT MACHINES
Press the Speed1 button - “E” (Figure 1) - and Accessory Functions button - ”D” (Figure 1) - at the same time for a few seconds to access the first screen; press the Increase button - “A” (Figure 1) - to access the subse­quent screens. The following screens are displayed ( in order) :
b_U tmp
138
Temperature of first boiler
2
(significant only for USA machines with 2 boilers)
AIG LE
60
Air Gap level
3
(significant only for atmospheric machines)
To return to the standard display, wait 30 seconds or press the Confirm button - “C” (Figure 1) -.
DOC. N. 5956.573.02 Page 5 / 80
Electrolux
U
U
U
U
U
USER MENU SERVICE MENU
EXIT
USER
SETTINGS
GENERIC FUNC.
RINSE
MODULE
WASH
MODULE
PREWASH
MODULEDTMODULE
DATA SETTING
PARAMETERS DATALOG INFO STATISTICS RINSE CONTROL KEY MANAGEM. SENS. ADJUST.
HACCP RATING
PLATE
FAC
(SERVICE MENU)
PAr
(PARAMETERS)
rfC
(RINSE CONTROL)
SAd
(SENSOR ADJUST.)
Inf
(INFO)
GFu
(GENERIC
FUNC.)
RiN
(RINSE
MODULE)
tub
(WASH
MODULE)
pRE
(PREWASH
MODULE)
Dt
(DT MODULE)
HAC
(HACCP)
EFS - Dishwashing Systems Platform Electrolux Professional
A2 ACCESSING THE USER MENU AND SERVICE MENU
From normal machine operation mode all the parameters and information can be accessed for programming the electronic boards by pressing the combinations of keys displayed in (Figure 3) and in (Figure 4).
Figure 3 Accessing the USER MENU Figure 4 Accessing the SERVICE MENU
From the USER MENU and SERVICE MENU it is possible to access the following parameter families and infor­mation see (Figure 5) and (Figure 6) using the increase (“A” - (Figure 1)) and decrease (“B” - (Figure 1)) keys to select the object, the confirm key (“C” - (Figure 1)) to access the selected object and the accessory functions key (“D” - (Figure 1)) to exit the object.
Figure 5 Parameter and function access menu chart for Modular Rack Type
DOC. N. 5956.573.02 Page 6 / 80
Figure 6 Parameter and function access menu chart for Compact Rack Type
Electrolux
CAUTION:
USER MENU
1 - EXIT 2 - DATA SETTING
1 2 3
DATE & TIME
09 NOV 05
14 : 25
SET DATE
09 NOV 05
09 NOV 05
12
MAY
SET TIME
15 : 25 : 32
14 : 25 : 32
EFS - Dishwashing Systems Platform Electrolux Professional
A3 USER MENU (ONLY FOR MODULAR RACK TYPE)
Press the accessory functions keys (“D” - (Figure 1)) and the increase key (“A” - (Figure 1)) at the same time for several seconds to access the USER MENU.
The current date and time used in recording events (see par. A4.2 DATALOG (ONLY FOR MODULAR RACK TYPE)) and statistics (see A4.4 STATISTICS (ONLY FOR MODULAR RACK TYPE)) can be set inside the USER MENU.
At first machine start-up make sure the date and time are correctly set.
The various USER MENU items can be selected by using the increase (“A” - (Figure 1)) and decrease (“B” - (Figure 1)) keys.
A3.1 EXIT
Press the confirm key (“C” - (Figure 1)) when the selection arrow indicates the item EXIT to return to normal machine operation.
A3.2 DATA SETTING
Press the confirm key (“C” - (Figure 1)) when the selection arrow indicates the item DATA SETTING and the display will show the set date and time:
Press the accessory functions key (“D” - (Figure 1)) to display the USER MENU again. To modify the set date, select the date with the increase (“A” - (Figure 1)) and decrease (“B” - (Figure 1)) keys and press the confirm key (“C” - (Figure 1)). The display shows the current date at the bottom and the date being set at the top.
Use the increase, decrease and confirm keys to modify the date.
To modify the set time, select the time with the increase and decrease keys and press the confirm key. The display shows the current time at the bottom and the time being set at the top.
DOC. N. 5956.573.02 Page 7 / 80
Use the increase, decrease and confirm keys to modify the time.
Electrolux
CAUTION:
SERVICE MENU
1 - PARAMETERS 2 - DATALOG
1 2 3
USER SETTINGS
USER SETTINGS
Language
ENGLISH
EFS - Dishwashing Systems Platform Electrolux Professional
A4 SERVICE MENU
Press the accessory functions key (“D” - (Figure 1)) and the decrease key (“B” - (Figure 1)) at the same time for several seconds to access the SERVICE MENU.
MODULAR RACK TYPE
COMPACT RACK TYPE
Inside the SERVICE MENU it is possible to:
display and edit all the machine parameters;
access the DATALOG, i.e. a file of events that occurred during machine operation (only for modular rack type);
display information of a general nature, such as the machine software versions;
consult a file of statistics relevant to the various machine load activation times and starts (only for modular rack type).
adjust the rinse flowrate cock ( just for atmospheric rack type).
Save the parameters, datalog content and content of the statistics in a removable backup memory (for modular RT's only).
Set the pressure sensors that detect the levels of the airgap, Duo rinse tank, wash tank and prewash tank.
After entering the SERVICE MENU switch the machine off and then on again to return to normal operation.
The various SERVICE MENU items can be selected by using the increase (“A” - (Figure 1)) and decrease (“B” - (Figure 1)) keys.
A4.1 PARAMETERS
Press the confirm key (“C” - (Figure 1)) when the arrow indicates the PARAMETERS item and the display will show the first family of parameters.
A4.1.1 USER SETTINGS (ONLY FOR MODULAR RACK TYPE)
The USER SETTINGS family contains parameters for setting the user interface.
Use the increase and decrease keys to select the other parameter families. Press the accessory functions key (“D” - (Figure 1)) to display the SERVICE MENU again. Press the confirm key (“C” - (Figure 1)) to access the first parameter of the USER SETTINGS family.
DOC. N. 5956.573.02 Page 8 / 80
Press the accessory functions key (“D” - (Figure 1)) to display the USER SETTINGS family again.
Electrolux
USER SETTINGS
Language
ENGLISH
GENERIC FUNC.
EFS - Dishwashing Systems Platform Electrolux Professional
Use the increase and decrease keys to select the other parameters of the USER SETTINGS family. Press the confirm key to edit the selected parameter; the selection arrow moves from the parameter name to
the parameter value.
Use the increase and decrease keys to modify the parameter value. Press the confirm key to save the new set value. Press the accessory functions key to exit without saving the new setting.
The USER SETTINGS family parameters are described below:
Parameter
name
Language 00
Contrast 01
Family
Nr.
Parameter
Nr.
Parameter description Unit of
measure
Allows setting of required language - - - English
Allows setting of screen contrast - 0 5 3
Min Max Factory
setting
A4.1.2 GENERIC FUNC.
The GENERIC FUNC. family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The GENERIC FUNC. family contains parameters that identify several general machine characteristics.
MODULAR RACK TYPE
COMPACT RACK TYPE
The GENERIC FUNC. family parameters are described below:
DOC. N. 5956.573.02 Page 9 / 80
Electrolux
EFS - Dishwashing Systems Platform Electrolux Professional
Modular
parameter
Appl. type
Appl.
direct.
Speed nr.
1
Wash t ime
sp 1
Speed nr.
2
Wash t ime
sp 2
Compact
paramet
er
APt
Ad
SP1
rd1
SP2
rd2
Family
Parame
Nr.
ter Nr.
1 0 Machine type for modular rack type:
1 1 Rack pulling direction (meaningful parameter only
1 2 Indicates gear motor operation frequency at speed
1 3 Time between insertion of rack and start of rinse
1 4 Indicates gear motor operation frequency at speed2.Hz 15 100 51 (**)
1 5 Time between insertion of rack and start of rinse
Parameter description Unit
Ws Ri : 2 modules rinse and wash. Pw Ws Ri : 3 modules rinse, wash and prewash. Pw Ws Ri Dt: 4 modules rinse, wash, prewash and DT. Ws Ri Dt: 3 modules rinse, wash and DT.
Machine type for compact rack type: 4: Compact pressurized plumbing circuit 5: Compact atmospheric plumbing circuit 6: Compact pressurized plumbing circuit with dt 7: Compact atmospheric plumbing circuit with dt 8: Compact pressurized plumbing circuit with prewash 9: Compact atmospheric plumbing circuit with prewash 10: Compact pressurized plumbing circuit with prewash and dt 11: Compact atmospheric plumbing circuit with prewash and dt 12: Compact Usa 13: Compact Usa with DT 14: Compact Usa with prewash 15: Compact Usa with prewash and DT
for Modular Rack Type): LEFT: left rack insertion. RIGHT: right rack insertion.
1.
phase when speed 1 is set.
phase when speed 2 is set.
of
meas
ure
- - - Ri Ws
-- -
-LEFT
Hz 15 100 27 (**)
sec 0 250 110
sec 0 250 58
Min Max Factory
RIGHT
setting [for
WTM165 (*)]
RIGHT
(*) For the other equipment families, see par. B1.1 MODULAR RACK TYPE
(**) (***)
(**)
(***)
(***)
Modular machine type WTM140 WTM180 WTM165 WTM200 WTM250 WTM300
Racks/h Speed nr. 1 80 110 90 130 160 180
Speed nr. 1 25 35 27 40 53 60
Racks/h Speed nr. 2 140 180 165 200 250 300
Speed nr. 2 45 59 51 63 83 100
Compact machine type RTC90 /
Racks/h Speed nr. 1 90 80 120 180 100 100
Speed nr. 1 27 25 35 57 31 31
Racks/h Speed nr. 2 90 140 180 220 200 200
Speed nr. 2 27 44 57 69 63 63
CTC90 /
WTC90
RTC140 / CTC140 /
WTC140
RTC180 / CTC180 /
WTC180
RTC220 /
CTC220 /
WTC220
To comply with Standard DIN 10510 it is advisable to use speed nr. 1
WT44 WT66
DOC. N. 5956.573.02 Page 10 / 80
Electrolux
EFS - Dishwashing Systems Platform Electrolux Professional
Modular
parameter
Clean
duration
Drain
enable
Compact
parameter
dCd
drE
Family
Parame
Nr.
1 11 Duration of wash phase during self-clean cycle. sec 0 100 15
1 16 Enabling of drain and self-clean cycles:
Parameter description Unit ter Nr.
0: All the drain and self-clean cycles are disabled.
1: Enables the drain cycle of all tanks in the
equipment.
5: Enables the drain cycle of all tanks in the equipment
and only the drain cycle for the wash tank.
7: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank and
only the drain cycle for the prewash tank.
13: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank and
only the drain cycle for the DUO rinse tank.
15: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank, only
the drain cycle for the prewash tank and only the drain
cycle for the DUO rinse tank.
21: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank and
the drain cycle for the air gap.
23: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank, only
the drain cycle for the prewash tank and the drain cycle
for the air gap.
29: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank, only
the drain cycle for the DUO rinse tank and the drain
cycle for the air gap.
31: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank, only
the drain cycle for the prewash tank, only the drain
cycle for the DUO rinse tank and the drain cycle for the
air gap.
33: Enables the drain cycle of all tanks in the
equipment and the self-clean cycle.
37: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank
and the self-clean cycle.
39: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank,
only the drain cycle for the prewash tank and the
self-clean cycle.
45: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank, only
the drain cycle for the DUO rinse tank and the self-
clean cycle.
47: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank, only
the drain cycle for the prewash tank, only the drain
cycle for the DUO rinse tank and the self-clean cycle.
49: Enables the drain cycle of all tanks in the
equipment and the self-clean cycle and the drain cycle
for the air gap.
53: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank
and the self-clean cycle and the drain cycle for the
air gap.
55: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank,
only the drain cycle for the prewash tank, the self-
clean cycle and the drain cycle for the air gap.
61: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank,
only the drain cycle for the DUO rinse tank, the
self-clean cycle and the drain cycle for the air gap.
63: Enables the drain cycle of all tanks in the
equipment, only the drain cycle for the wash tank,
only the drain cycle for the prewash tank, only the
drain cycle for the DUO rinse tank, the self-clean
cycle and the drain cycle for the air gap.
Min Max Factory
of
meas
ure
- 0 63 61
setting [for
WTM165 (*)]
DOC. N. 5956.573.02 Page 11 / 80
Electrolux
CAUTION:
CAUTION:
CAUTION:
EFS - Dishwashing Systems Platform Electrolux Professional
.
Modular
parameter
Heat two
comm.
Heating manage
Compact
parameter
H2C
B_t
Family
Parame
Nr.
1 18 Modular Rack Type:
1 19 Machine heating power management.
Parameter description Unit ter Nr.
Wash tank heating element management mode; if set
on “Yes” the two heating elements are managed by two
separate controls, otherwise they are managed by a
single control (See Figure 7 Scheme for “Heat two
comm.” parameter and “Heating manage”
parameter (only for Modular Rack Type)).
Compact Rack Type:
Wash tank heating element management mode; if set
on “1” the two heating elements are managed by two
separate controls, otherwise they are managed by a
single control (See Figura 8 Scheme for “H2C”
parameter and “b_t” parameter (only for Compact
Rack Type)).
Maximum power: the wash tank heating elements
and the boiler heating elements can operate at the
same time.
Check the electrical system and safety
devices ahead of the equipment before
setting “Max. power” mode
Medium power: when the boiler heating elements are
on, only one of the two wash tank heating elements
can operate; during the warmup, the tank is heated
first and then the boiler, whereas the boiler has priority
during normal operation.
Minimum power: the wash tank heating elements
cannot operate when the boiler heating elements are
on; during the warmup, the tank is heated first and
then the boiler, whereas the boiler has priority during
normal operation (See Figure 7 Scheme for “Heat
two comm.” parameter and “Heating manage”
parameter (only for Modular Rack Type) and
Figura 8 Scheme for “H2C” parameter and “b_t”
parameter (only for Compact Rack Type)).
Modular Rack Type:
“HIGH” = Maximum power
“MEDIUM” = Medium power
“LOW” = Minimum power
Min Max Factory
of
meas
ure
-NoYes Yes
-01 0
-LOWHIGHMEDIUM
setting [for
WTM165 (*)]
THIS CONFIGURATION CAN ONLY
WORK ON ELECTRICALLY ARRANGED
MACHINES AND THE “Heat two comm.”
PARAMETER MUST BE SET ON “Yes”.
The machines electrically arranged to operate in
“MEDIUM” mode are the WTM165 and the WTM200
models.
Compact Rack Type:
“0” = Maximum power
“2” = Medium power
“1” = Minimum power
-01 0
THIS CONFIGURATION “2” CAN NOT
BE IMPLEMENTED IN THE ACTUAL
VERSIONS OF COMPACT RACK TYPE.
DOC. N. 5956.573.02 Page 12 / 80
Electrolux
SINGLE
CONTACTOR
HARDWARE MACHINE
CONFIGURATION
0
1
b_tH2C
(Maximum Power)
(Minimum Power)
EFS - Dishwashing Systems Platform Electrolux Professional
HARDWARE MACHINE
CONFIGURATION
SINGLE
CONTACTOR
HIGH
LOW
HIGH
Figure 7 Scheme for “Heat two comm.” parameter and “Heating manage” parameter (only for Modular
Modular
parameter
Boiler
load tank
Sanit.
enable
Heat
pump
Fahrenhei
t vis.
Figura 8 Scheme for “
Compact
parameter
btF
SnE
HP
CF
Family
Nr.
1 20 Modular Rack Type:
1 22 Enables sanitization cycle (N.B.: heating element
1 23 Enables heat pump management.
1 25 Unit of measure used in displaying temperatures; if
H2C
” parameter and “
Para
meter
Parameter description Unit of
Nr.
Wash tank filling mode: the tank is filled by means of a dedicated solenoid valve.
Standard Compact Rack Type: Wash tank filling mode: the tank is filled by means of the rinse arms.
Usa Compact Rack Type: Wash tank filling mode: the tank is filled by means of a dedicated solenoid valve.
must be installed in prewash module).
Modular Rack Type: “No” sanitization cycle disable “Yes” sanitization cycle enable.
Compact Rack Type: “0” sanitization cycle disable “1” sanitization cycle enable.
The heat pump contains 1050 g of R134a refrigerant liquid in its hydraulic circuit.
Modular Rack Type: “No” heat pump management disable “Yes” heat pump management enable.
Compact Rack Type: “0” heat pump management disable “1” heat pump management enable.
set on “Yes” the temperature is displayed in degrees Fahrenheit, otherwise in degrees Celsius.
Modular Rack Type: “No” the temperature is displayed in degrees Celsius “Yes” the temperature is displayed in degrees Fahrenheit.
Compact Rack Type: “0” the temperature is displayed in degrees Celsius “1” the temperature is displayed in degrees Fahrenheit.
DOUBLE
CONTACTOR
MEDIUM
LOW
Heat two comm. Heating manage
Rack Type)
b_t
” parameter (only for Compact Rack Type)
measure
-NoYesNo
-01 1
-01 0
-NoYesNo
-01 0
-NoYesNo
-01 0
-NoYesNo
-01 0
Min Max Factory
setting
[for
WTM165
(*)]
DOC. N. 5956.573.02 Page 13 / 80
Electrolux
CAUTION:
Speed n°1 (Hz) Capacity speed n°1 (racks/hour) Delay speed n° 1 (sec) Speed n°2 (Hz) Capacity speed n°2 (racks/hour) Delay speed n° 2(sec) WTM140 25 80 22 45 140 12 WTM165 27 90 20
51 165 11 WTM180 35 110 15 58 180 9 WTM200 40 130 13 63 200 9 WTM250 53 160 10 83 250 6 WTM300 60 180 9 100 300 5
EFS - Dishwashing Systems Platform Electrolux Professional
Buzzer
enabled.
Demo mode
Rinse
autostart.
Max.
motor
***
curr.
b_E
dMo
r_A
GCU ***
1 26 Enables machine buzzer.
Modular Rack Type: “No” machine buzzer disable “Yes” machine buzzer enable.
Compact Rack Type:
- The buzzer is always enabled.
1 27 Demo mode.
Modular Rack Type:
- “No demo” normal operation.
- “Demo mec” the users are not activated and the inputs are not read, but communication between the USER card and POWER cards is maintained .
- “Demo user” the users are not activated, the inputs are not read, the USER card doesn’t communicate with the POWER cards.
Compact Rack Type:
- “0” normal dishwasher operation.
- “1” the users are not activated and the inputs are not read, but communication between the USER card and POWER cards is maintained .
- “2” not available on these models.
1 28 Indicates the type of command for the start of the
1 29 Indicates the maximum current supplied from the
rinse phase. It can be set to “Mechanical” (1) only if the special mechanical lever is present in the rinse
**
zone.
inverter to the gear motor. If the supplied current is higher than this value,the message “CROCKERY STUCK” appears on modular Rack Type and the message “
INSIDE
” on compact Rack Type.
SEE ITEM
-NoYesYes
-01 0
---No demo
--- 0
Sof
Mec hani
cal/
1
-
Software/
0
35
(110Vac
gearmotor
)
0
(230Vac
gearmotor
)
twa re/0
dec Amp.-0-40
Set
default
par.
spd
130
It allows all the parameters to be set to their default value. The set parameters are those of a WTM165 without DT. The parameter set to “Yes” (1) automatically returns to “No” (0).
-No/ 0Ye s / 1
No/
0
(*) For the other equipment families, see par. Table 1 Machine codes list and relative programming sheets.
** The table given below indicates the delay between transit of the rack on the autorinse lever and stopping of the rinse phase. E.g. in a WTM165 working at high speed (165 racks/h) the rinse pump keeps operating for 11 seconds after the last rack has released the autorinse lever.
*** Procedure for correctly setting the “Max. motor curr.” parameter:
1. Wait until the machine, complete with tables, is ready for a wash cycle.
2. Start a wash cycle and read the current absorbed by the gear motor ( refer to par. A1 “DISPLAY OF AUXILIARY VALUES”).
3. Add 2 to the read value (e.g. if “Motor current” = 34 ---> 34+2=36 decA).
4. Set the “Max. motor curr.” parameter with the value thus obtained.
The Rack Type leaves the factory with the “Max motor curr.” parameter already set to the optimum value. Reset it only when replacing a PCB or the gear motor.
DOC. N. 5956.573.02 Page 14 / 80
Electrolux
RINSE MODULE
EFS - Dishwashing Systems Platform Electrolux Professional
A4.1.3 RINSE MODULE
The RINSE MODULE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The RINSE MODULE family contains the parameters that identify the rinse module characteristics.
MODULAR RACK TYPE
The RINSE MODULE / rin family parameters are described below:
Modular
parameter
Max. lev. airgap(*)
Max hist.
airgap(*)
Work h is t.
airgap(*)
Max. lev.
duo (**)
Dm max duo lev.
(**)
Max hist.
duo (**)
Work l ev.
duo (**)
Boil. temp.
start
Boiler
temper.
Hist. boil
temp.
First boil.
temp.
First boil.
hist.
Duo
temper.
Hist. duo
temp.
Drain del.
airgap
Drain delay
duo
Compact
parameter
ASL(*)
ASH(*)
AnL(*)
dSL(**)
(meaningless
for compact
famil y)
dSd(**)
(meaningless
for compact
famil y)
dSH(**)
(meaningless
for compact
famil y)
dnL(**)
(meaningless
for compact
famil y)
btS
bot
btH
Fbt
FbH
dut
dtH
Add
ddd
Family
Paramet
Nr.
2 0 Max water level in air gap. mmH2O 30 100 90
2 1 Hysteresis level relative to max level in the air gap. mmH2O 0 80 30
2 2 Water level in the air gap enabling rinse pump
2 4 Indicates the maximum level in the Duo rinse tank.
2 5 Meaningful only during ““Drain and clean” cycle.
2 6 Indicates the hysteresis level relative to the
2 7 Indicates the water level in the the Duo tank
2 9 Boiler temperature set point at start of rinse
2 10 Boiler temperature set point. °C / °F 10/5099/
2 11 Hysteresis temperature relative to boiler
2 12 First boiler temperature set point.
2 13 Hysteresis temperature relative to first boiler
2 14 DUO rinse tank temperature set point. °C / °F 5/41 95/
2 15 Hysteresis temperature relative to DUO rinse tank
2 17 Time between reaching level “0” (air trap level) in
2 19 Time between reaching level “0” (air trap level) in
Nr.
Parameter description Unit of
er
operation.
The filling stops when the water level reaches this value.
Indicates the maximum level during “Drain and clean” cycle.
maximum level in the Duo tank. It is related to the “Max. lev. duo” and to the “Dm max duo lev.”.
enabling the Duo heating element and the Duo pump operations.
phase; the initial overtemperature determined by this parameter ensures that the introduction of cold water in the boiler does not lower the rinse water temperature at the start of rinsing.
temperature set point.
( Significant only for USA machines with 2 boilers).
temperature set point. ( Significant only for USA machines with 2 boilers).
temperature set point.
the air gap and stop of rinse pump.
the DUO rinse tank and closing of the drain solenoid valve; allows complete emptying of tank.
COMPACT RACK TYPE
Min Max Factory
measure
mmH2O 0 100 50
mmH2O 30 100 55
mmH2O 10 100 40
mmH2O 0 80 15
mmH2O 0 50 20
°C / °F 10/5099/
°C / °F 0/0 15/
°C / °F 0/32 99/
°C / °F 0/0 15/
°C / °F 0/0 50/
sec 0 200 32
sec 0 200 30
210
210
27
210
27
203
90
setting
92/198
86/187
0/0
59/138
0/0
70/158
5/9
DOC. N. 5956.573.02 Page 15 / 80
Electrolux
WASH MODULE
EFS - Dishwashing Systems Platform Electrolux Professional
Heat. tim.
enable
Duo heat.
unrel.
Airgap
area
(*) The difference between the max. water level and the hysteresis level must be higher than the work hysteresis airgap. Max. lev. airgap - Max. hist. airgap Work hist. airgap
ASL
-
(**) The difference between the max. water level and the hysteresis level must be higher than the working level: Max. lev. duo - Max. hist. duo > Work lev. duo (**) The difference between the max. water level during drain cycle and the hysteresis level must be higher than the working level: Dm max duo lev. - Max. hist. duo > Work lev. duo
ASH
>
HtE
dHU
AAG
AnL
2 20 Allows enabling/disabling of the boiler heating
2 21 Allows the Duo heating element operation to be
2 22 Defines the base area of the airgap. This value is
Time out alarm ( alarm 15). If the parameter is set to “No” (0), the alarm 15 does not appear even if the boiler never reaches the setpoint temperature.
freed from that of the other heating elements. If set to “Yes” (1) the Duo heating element can switch on even if the tank and boiler heating elements are on.
used in the “Rinse control” procedure.
-No/ 0Yes/ 1Yes/
-No/ 0Yes/
mmq 500 999 700
1
No/
1
0
A4.1.4 WASH MODULE
The WASH MODULE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The WASH MODULE family contains the parameters that identify the wash module characteristics.
MODULAR RACK TYPE
COMPACT RACK TYPE
The WASH MODULE / tub family parameters are described below:
Modular paramet
er
Wash
module
Stanby
level (**)
Run max
level (**)
Drain
max lev.
(**)
Max lev.
hister.
(**)
Worki ng level (**)
Tan k
temper.
Sanit.
temper.
Compact
parameter
tty
tSS(**)
tSr(**)
tSd(**)
tSH(**)
tnL(**)
tut
tSt
Family
Param
Nr.
3 0 Type of wash module
3 1 Indicates the maximum level in the wash tank.
3 2 The value for the maximum level is modified from
3 3 Meaninful only during “Drain and clean” cycle.
3 4 Indicates the hysteresis level relative to the
3 5 Indicates the water level in the wash tank
3 7 Tank temperature set point. °C / °F 5/41 90/194 66/151
3 8 Tank temperature set point during the
Parameter description Unit of
eter
Nr.
Modular Rack Type:
- “1165” module from 1165 mm
- “1490” module from 1490 mm.
Compact Rack Type:
- “2” Wash+Rinse module
The filling stops when the water level reaches this level.
“Standby level” to “Run max level” during washing phase in order to avoid water loss when the pumps stop.
Indicates the maximum level during “Drain and clean” cycle.
maximum level in the wash tank. It is related to the “Standby level” to the “Run max level” and to the “Drain max lev.”.
enabling the wash tank heating elements and the wash pumps operations.
sanitization phase (only on machines with sanitization).
measure
---1490
---2
mmH2O 60 400 205
mmH2O 60 400 170
mmH2O 60 400 190
mmH2O 0 80 30
mmH2O 60 400 90
°C / °F 10/50 90/194 75/167
Min Max Factory
setting
[for
WTM165
(*)]
DOC. N. 5956.573.02 Page 16 / 80
Electrolux
CAUTION:
CAUTION:
EFS - Dishwashing Systems Platform Electrolux Professional
Histesys
temp.
Max
Tem p.
CU
Hist.
Tem p.
CU
Tem p.
Thresh.
CU
Wash
san.
duration
Fan
delay
start
Fan
delay
stop
Drain delay
Autom.
drain
del.
Wate r to
drain
Condensi
ng unit
ttH
StC
HtC
ttC
Std
CGd
CSd
dtd
Atd
qtd
CUn
3 9 Hysteresis temperature relative to tank
3 10 Max permissible temperature for the water
temperature set point.
leaving the CU to enable heat pump operation. If the water leaving the CU exceeds this temperature, the machine continues to work normally but the heat pump (if present) stops.
°C / °F 0/0 50/90 2/4
°C / °F 1/34 90/194 50/122
Do not modify this parameter unless expressly required by the factory.
3 11 Max permissible temperature for the water
leaving the CU to enable heat pump operation: if the temperature of the water leaving the CU falls below “Max temp. CU - Hist. temp. CU”, the machine continues to work normally but the heat pump (if present) stops.
°C / °F 1/2 20/46 50/90
Do not modify this parameter unless expressly required by the factory.
3 12 Meaninful only for machines with heat pump.
3 13 Duration of wash tank cleaning phase during a
3 14 The time between start of wash and start of CU
3 15 The time between stop of wash phase and stop
3 17 Time between reaching level “0” (air trap level) in
3 18 Time between two automatic water changes. If
3 19 Quantity of water to be drained with each
3 20 CU presence. - No/0 Yes/1 Yes/1
Indicates the CU temperature when the washing tank heating elements stop. This function is enabled only if the heat pump is installed and allows maintaining the CU temperature compatible with the heat pump features.
sanitization cycle.
fan ( Parameter not significant for Compact Rack Type ).
of CU fan ( Parameter not significant for Compact Rack Type ).
the tank and closing of the drain solenoid valve; allows complete emptying of wash tank
this parameter is set at zero the function is disabled.
automatic emptying.
°C / °F 20 / 68 70 /
158
sec 0 250 60
sec 0 200 0
sec 0 200 20
sec 0 200 30
min 0 250 120
mmH2O 0 100 25 (***)
48 / 118
(*) For the other equipment families, see par. Table 1 Machine codes list and relative programming sheets.
(***)
(**) The difference between the max water level and the hysteresis level must be higher than the working level:
WASH TANKS 1165 1490
Tank capacity 100 l 150 l
Water to drain (in litres/mm) 0,32 l/mm 0,485 l/mm
Stanby level - Max lev. hister > Working level tSS - tSH > tnl
(**) The difference between the max water level during washing phase and the hysteresis level must be higher than the working level: Run max level - Max lev. hyster. > Working level
tSr - tSH > tnl
(**) The difference between the max water level during drain cycle and the hysteresis level must be higher than the working level: Drain max lev. - Max lev. hyster. > Working level
tSd - tSH > tnl
DOC. N. 5956.573.02 Page 17 / 80
Electrolux
PREWASH MODULE
EFS - Dishwashing Systems Platform Electrolux Professional
A4.1.5 PREWASH MODULE
The PREWASH MODULE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The PREWASH MODULE family contains the parameters that identify the prewash module characteristics.
MODULAR RACK TYPE
COMPACT RACK TYPE
The PREWASH MODULE / PrE family parameters are described below:
: (**) The difference between the max water level and the hysteresis level must be higher than the working level:
Modular paramet
er
Prewash
module
Stanby
level
Run level
Drain
max lev.
Max lev.
hister.
Working
level
Tan k
temper.
Sanit.
temper.
Histesys
temp.
Prew.
san.
durat.
Drain
delay
Autom.
drain
del.
Water to
drain
Max
temper.
prew.
Compact
parameter
Pty
SbL(**)
PSS(**)
PSd(**)
PSH(**)
PnL(**)
Prt
PSt
PtH
SPd
dPd
APd
qPd
dPt
Family
Nr.
Param
eter
4 0 Type of prewash module
4 1 Indicates the maximum level in the prewash tank. The
4 2 The value for the maximum level is modified from
4 3 Meaninful only during “Drain and clean” cycle.
4 4 Indicates the hysteresis level relative to the maximum
4 5 Indicates the water level in the prewash tank enabling
4 7 Tank temperature set point. °C / °F 5/4190/
4 8 Tank temperature set point during sanitization phase
4 9 Hysteresis temperature relative to tank temperature
4 10 Duration of wash tank cleaning phase during a
4 12 Time between reaching level “0” (air trap level) in the
4 13 Time between two automatic water changes. If this
4 14 Quantity of water to be drained with each automatic
4 15 Max permissible temperature in prewash tank. If the
Parameter description Unit of
Nr.
- “1165-600” module from 1165 mm or from 600 mm
- “1490” module from 1490 mm.
- “0” module from 1165 mm or from 600 mm
- “1” module from 1490 mm.
filling stops when the water level reaches this value.
“Stanby level” to “Run level” during prewashing phase in order to avoid water loss when the pumps stop.
Indicates the maximum level during “Drain and clean” cycle.
level in the prewash tank. It is related to the “Stanby level” , to the “Run level” and to the “Drain max lev.”.
the prewash tank heating elements and the prewash pumps operations.
(only on machines with sanitization - N.B.: heating element must be installed in prewash module).
set point.
sanitization cycle.
tank and closing of the drain solenoid valve; allows complete emptying of tank.
parameter is set at zero the function is disabled.
emptying.
tank temperature exceeds the set temperature, a quantity of water equal to the quantity set by means of the "Water to drain" parameter is drained. If this parameter is set at zero the function is disabled.
measur
e
- - - 1165-600
--- 0
mmH2O 60 400 220
mmH2O 60 400 180
mmH2O 60 400 190
mmH2O 0 80 30
mmH2O 60 400 90
°C / °F 10/5090/
°C / °F 1/2 50/90 5/9
sec 0 250 60
sec 0 200 30
min 0 250 50
mmH2O 0 50 10 (****)
°C / °F 0/3299/
Min Max Factory
194
194
210
setting
[for
WTM200
(*)]
10/50
75/167
40/104
Stanby level - Max lev. hister > Working level
DOC. N. 5956.573.02 Page 18 / 80
Electrolux
DT MODULE
EFS - Dishwashing Systems Platform Electrolux Professional
SbL - PSH > Pnl
(**) The difference between the max water level during washing phase and the hysteresis level must be higher than the working level: Run level - Max lev. hister > Working level
PSS - PSH > Pnl
(**) The difference between the max water level during drain cycle and the hysteresis level must be higher than the working level: Drain max level - Max lev. hister > Working level
PSd - PSH > Pnl
(*) For the other equipment families, see par. Table 1 Machine codes list and relative programming sheets.
(****)
PREWASH TANKS 600 1165 1490
Tank capacity 45 l 100 l 150 l
Water to drain (in litres/mm) 0,136 l/mm 0,32 l/mm 0,485 l/mm
A4.1.6 DT MODULE
The DT MODULE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The DT MODULE family contains the parameters that identify the drying zone (DT) characteristics.
MODULAR RACK TYPE
COMPACT RACK TYPE
The DT MODULE / dt family parameters are described below:
Modular paramet
er
Dt
temper.
Dt hist.
temp.
Dt fan
delay
Dt type.
Compact
parameter
dtt
dtH
Afd
d_t
Family
Paramet
Nr.
5 0 Drying tunnel temperature set point. °C / °F 10/5090/
5 1 Hysteresis temperature relative to the drying tunnel
5 3 Time between stop of DT heating element and stop
5 4 Indicates the type of DT installed. - Stan
er
Nr.
Parameter description Unit of
temperature set point.
of DT fan. This parameter ensures a correct cooling for the DT heating element.
measure
°C / °F 0/0 50/
sec 0 250 120
Min Max Factory
dard
/0
194
90
New
type/
1
setting
70/158
3/5
Standard/
0
DOC. N. 5956.573.02 Page 19 / 80
Electrolux
HACCP
RATING PLATE
RATING PLATE
P.N.C.
0000000000000
EFS - Dishwashing Systems Platform Electrolux Professional
A4.1.7 HACCP
The HACCP family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family.
The HACCP family contains the parameters that identify the HACCP connection characteristics.
MODULAR RACK TYPE
COMPACT RACK TYPE
The HACCP / HAC family parameters are described below:
Modular paramet
er
HACCP
address
IR
Address
HACCP
baud
rate
IR baud
rate
Compact
parameter
Adr
IrA
Hbr
Ibr
Family
Nr.
6 0 Specific address of equipment in an HACCP network. - 0 254 1
6 1 Specific address of equipment in an IrDa communication
62
6 3 Indicates the communication speed of the equipment in
Paramet
er
Nr.
Parameter description Unit
network.
Indicates the communication speed of the equipment in an HACCP network.
an IrDa communication network.
of
meas
ure
- 0 254 1
- 1200/0192
- 1200/0192
A4.1.8 RATING PLATE (ONLY FOR MODULAR RACK TYPE)
The RATING PLATE family contains the parameters that identify the machine rating data.
Min Max Facto
00/4
00/4
ry
settin
g
9600/
3
9600/
3
The RATING PLATE family parameters are selected and edited by using the keys in the same way as that described for the USER SETTINGS family except for the "STRING" parameters given in the following table.
After a “STRING” is displayed
the parameter can be edited by pressing the confirm key; the selection arrow moves from the parameter name to the parameter value.
DOC. N. 5956.573.02 Page 20 / 80
Electrolux
RATING PLATE
P.N.C.
0000000000000
RATING PLATE
P.N.C.
0000000000000
EFS - Dishwashing Systems Platform Electrolux Professional
Use the increase and decrease keys to move the cursor until it is under the digit to be modified. Press the con­firm key to modify the selected digit.
The digit flashes and the value of the digit selected can be modified by using the increase and decrease keys. Press the confirm key to save the new value. Press the accessory functions key to exit without saving.
When all the digits have been modified as required, press the accessory functions key to return to parameter selection mode.
The RATING PLATE family parameters are described below:
Parameter
name
P.N.C. 70
Serial number 71
Model 72
Constr. year 73
Prod. site 74
Inst. power 75
Voltage supply 76
Frequency 77
Max. current 78
MCA 79
MOP 710
Prot. degree 711
Inst. day 712
Inst. month 713
Inst. year 714
Family
Nr.
meter
Parameter description Unit of
Para
measu
Nr.
Product Number Code - - - - 534104 00 Yes
Serial number - - - - 54600001 Yes
Factory Model - - - - WTM165ERA
Year of construction - - - - 2007 Yes
Production site (6 = Washing) - 0 10 6 6 Yes
Installed power kW - - - 42.3 KW Yes
Power supply voltage F - - -
Frequency Hz 50 60 50 50 Hz No
Absorbed current A 6 32 6 65A No
MCA (Minimum supply Circuit Ampacity) [for USA versions only]
MOP (Maximum Overcurrent Protection) [for USA versions only]
Protection rating - IPX5 IPX5 Yes
Installation day (*****) - - - - 20 Yes
Installation month (*****) - - - - 06 Yes
Installation year (*****) - - - - 07 Yes
re
A - - - ----- Yes
A - - - ----- Yes
(*****) The installer must set the day, month and year of installation.
Min Max
Factory
setting
Example
+DT
AC 400 V 3P N
“STRING” parameter
Ye s
Ye s
DOC. N. 5956.573.02 Page 21 / 80
Electrolux
EVENT DATALOG
34 WASH OVERTEMP.
TYPE DD-MM-YY HH:HH VALUE
START 10-10-05 14:10 80 °C
WASH OVERTEMP.
STOP 10-10-05 14:15
EVENT DATALOG
34 WASH OVERTEMP.
TYPE DD-MM-YY HH:HH VALUE
START 10-10-05 14:10 80 °C
POWER OFF
STOP 10-10-05 14:15
EVENT DATALOG
34 WASH OVERTEMP.
TYPE DD-MM-YY HH:HH VALUE
START 10-10-05 14:10 80 °C
STOP ------------ --:-- -------
EFS - Dishwashing Systems Platform Electrolux Professional
A4.2 DATALOG (ONLY FOR MODULAR RACK TYPE)
Accessing the "DATALOG" mode allows a number of events that occurred in the machine to be displayed. In addition to the event, the screen also shows the time the event began and ended, as well as other informa­tion whose significance depends on the type of event recorded.
Every event is characterised by a START date and time and a STOP date and time. The event STOP can be recorded when its cause is no longer present (e.g. a temperature exceeding the per-
missible upper limit and then coming within the correct range),
or when the machine is switched off following shutdown by the user (POWER OFF) or no power (POWER FAIL). In the latter case, event STOP is described with the indication POWER OFF or POWER FAIL.
If accessing the display of an event that began after the last machine start and which has not ended because its cause is still present, closing of the event is not displayed.
DOC. N. 5956.573.02 Page 22 / 80
Electrolux
EFS - Dishwashing Systems Platform Electrolux Professional
List of events documented by the DATALOG:
Event
number
Event name Event description Event value (VALUE)
1 BOIL. TEMP. HIGH The boiler temperature has exceeded the temperature set point
2 DUO TEMP. HIGH The duo rinse temperature has exceeded the temperature set
3 WASH. TEMP. HIGH The wash tank temperature has exceeded the temperature set
4 PREW. TEMP. HIGH The prewash tank temperature has exceeded the temperature
5 DT TEMP. HIGH The dry tunnel temperature has exceeded the temperature set
6 BOIL. TEMP. LOW During the wash phase the boiler temperature has decreased
7 DUO TEMP. LOW During the wash phase the duo rinse temperature has decreased
8 WASH TEMP. LOW During the wash phase the wash tank temperature has
9 DT TEMP. LOW During the wash phase the dry tunnel temperature has
11 AIRG. FILL. TOUT Alarm number 11 has occurred:
12 AIRG. LEV. FAULT Alarm number 12 has occurred:
13 DUO FILL. TOUT Alarm number 13 has occurred:
14 DUO LEV. FAULT Alarm number 14 has occurred:
15 BOIL. HEAT. TOUT Alarm number 15 has occurred:
16 BOILER OVERTEMP. Alarm number 16 has occurred:
17 BOILER NTC SHORT Alarm number 17 has occurred:
18 BOILER NTC OPEN Alarm number 18 has occurred:
19 DUO HEAT. TOUT Alarm number 19 has occurred:
20 DUO OVERTEMP. Alarm number 20 has occurred:
21 DUO NTC SHORT Alarm number 21 has occurred:
22 DUO NTC OPEN Alarm number 22 has occurred:
23 RIN. PUMP THERM. Alarm number 23 has occurred:
24 DUO PUMP THERM. Alarm number 24 has occurred:
25 DRAIN DUO TOUT Alarm number 25 has occurred:
27 INVERTER ERROR Alarm number 27 has occurred:
30 DRAIN AIRG TOUT Alarm number 30 has occurred:
31 WASH FILL. TOUT Alarm number 31 has occurred:
32 WASH LEV. FAULT Alarm number 32 has occurred:
33 WASH HEAT. TOUT Alarm number 33 has occurred:
by 7 °C/13 °F.
point by 8 °C/14 °F.
point by 8 °C/14 °F.
set point by 35 °C/63 °F.
point by 15 °C/27 °F.
by more than 12 °C/25 °F with respect to the permissible min. value (– hysteresis temperature set point).
by more than 15 °C/27 °F with respect to the permissible min. value (–hysteresis temperature set point).
decreased by more than 15 °C/27 °F with respect to the permissible min. value (–hysteresis temperature set point).
decreased by more than 15 °C/27 °F with respect to the permissible min. value (–hysteresis temperature set point).
The Air Gap was not completely filled within the max. filling time.
The pressure sensor on the rinse module electronic board does not work correctly.
The Duo-rinse tank was not completely filled within the max. filling time.
The pressure sensor on the Duo-rinse tank does not work correctly.
The required temperature was not reached in the boiler within the max. heating time.
The water temperature in the boiler is too high
The boiler temperature sensor is short circuited.
The boiler temperature sensor is open.
The required temperature was not reached in the Duo-rinse tank within the max. heating time.
The water temperature in the Duo-rinse tank is too high.
The Duo-rinse tank temperature sensor is short circuited.
The Duo-rinse tank temperature sensor is open.
MODULAR: The rinse pump thermal protector has tripped. COMPACT: The rinse pump thermal protector, the wash pump thermal protector or the CU thermal protector has tripped.
The Duo-rinse pump thermal protector has tripped.
The Duo-rinse tank was not completely emptied within the max. emptying time.
The motor control inverter has generated an error.
The Air gap was not completely emptied within the max. emptying time.
The wash tank was not completely filled within the max. filling time.
The pressure sensor on the wash tank does not work correctly.
The required temperature in the wash tank was not reached within the max. heating time.
Indicates the boiler temperature at the time of event recording.
Indicates the duo rinse temperature at the time of event recording.
Indicates the wash tank temperature at the time of event recording.
Indicates the prewash temperature at the time of event recording.
Indicates the dry tunnel temperature at the time of event recording.
Indicates the boiler temperature at the time of event recording.
Indicates the duo rinse temperature at the time of event recording.
Indicates the wash tank temperature at the time of event recording.
Indicates the dry tunnel temperature at the time of event recording.
Indicates the air gap level at the time of event recording.
Indicates the air gap level at the time of event recording.
Indicates the duo rinse level at the time of event recording.
Indicates the duo rinse level at the time of event recording.
Indicates the boiler temperature at the time of event recording.
Indicates the boiler temperature at the time of event recording.
Not significant
Not significant
Indicates the duo rinse temperature at the time of event recording.
Indicates the duo rinse temperature at the time of event recording.
Not significant
Not significant
Not significant
Not significant
Indicates the duo rinse level at the time of event recording.
Indicates the selected speed at the time of event recording.
Indicates the airgap level at the time of event recording.
Indicates the wash tank level at the time of event recording.
Indicates the wash tank level at the time of event recording.
Indicates the wash tank temperature at the time of event recording.
DOC. N. 5956.573.02 Page 23 / 80
Electrolux
EFS - Dishwashing Systems Platform Electrolux Professional
Event
number
Event name Event description Event value (VALUE)
34 WASH OVERTEMP. Alarm number 34 has occurred:
35 WASH NTC SHORT Alarm number 35 has occurred:
36 WASH NTC OPEN Alarm number 36 has occurred:
37 WASH PUMP1 THER. Alarm number 37 has occurred:
38 WASH PUMP2 THER. Alarm number 38 has occurred:
39 CU FAN THER. Alarm number 39 has occurred:
40 DRAIN WASH TOUT Alarm number 40 has occurred:
42 AIRGAP LEV. LOW The air gap tank water level has fallen by more than 10 mm with
43 DUO LEV. LOW The duo rinse tank water level has fallen by more than 10 mm
44 WASH LEV. LOW The wash tank water level has fallen by more than 20 mm with
45 PREWASH LEV. LOW The prewash tank water level has fallen by more than 20 mm with
46 POWER ON Records appliance activation. Not significant
47 FORCED WASH A wash start has been forced. Indicates the boiler temperature at the time
48 EMERGENCY
SWITCH
49 PARAMETER MODE Parameter mode has been accessed. Not significant
50 PARAMETER MODIF. A parameter has been modified. Indicates the modified family and parameter
51 PREW. FILL. TOUT Alarm number 51 has occurred:
52 PREW. LEV. FAULT Alarm number 52 has occurred:
53 PREW. HEAT. TOUT Alarm number 53 has occurred:
54 PREW. OVERTEMP. Alarm number 54 has occurred:
55 PREW. NTC SHORT Alarm number 55 has occurred:
56 PREW. NTC OPEN Alarm number 56 has occurred:
57 PREW. PUMP THER.
58 DRAIN PREW. TOUT Alarm number 58 has occurred:
60 CU NTC SHORT The warning number 60 has occurred:
61 CU NTC OPEN The warning number 61 has occurred:
62 HEAT PUMP FAULT The warning number 62 has occurred:
63 CU TEMP. HIGH The CU temperature has exceeded by 8°C/14°F degrees the
64 CU TEMP. LOW During the wash phase the CU temperature has decreased by
65 LEV. LOW WASH Washing has stopped due to a lowering of the levels Indicates the air gap level at the time of
66 RINSE FLOW CTRL A calibration cycle for the rinse flow shutter has been started. Whole part and fractional part of the flow
71 DT HEAT. TOUT Alarm number 71 has occurred:
72 DT OVERTEMP. Alarm number 72 has occurred:
The water temperature in the wash tank is too high.
The wash tank temperature sensor is short circuited.
The wash tank temperature sensor is open.
The upper wash pump thermal protector has tripped.
The lower wash pump thermal protector has tripped.
The CU (condensing unit) fan thermal protector has tripped.
The wash tank was not completely emptied within the max. emptying time.
respect to the permissible min. level (–hysteresis set point level).
with respect to the permissible min. level (–hysteresis set point level).
respect to the permissible min. level (–hysteresis set point level).
respect to the permissible min. level (–hysteresis set point level).
The emergency mushroom has been pressed. Not significant
The prewash tank was not completely filled within the max. filling time.
The pressure sensor on the prewash tank does not work correctly.
The required temperature in the prewash tank was not reached within the max. heating time.
The water temperature in the prewash tank is too high.
The prewash tank temperature sensor is short circuited.
The prewash tank temperature sensor is open.
Alarm number 57 has occurred: The prewash pump thermal protector has tripped.
The prewash tank was not completely emptied within the max. emptying time.
The CU temperature sensor is short circuited.
The CU temperature sensor is open.
Indicates that the heat pump has generated an error.
permissible max. value to ensure the correct operation of the heat pump.
more than 10 °C/18 °F with respect to the permissible min. value (–hysteresis temperature set point) to ensure the correct operation of the heat pump.
The required temperature in the drying tunnel was not reached within the max. heating time.
The temperature in the drying tunnel is too high.
Indicates the wash tank temperature at the time of event recording.
Not significant
Not significant
Not significant
Not significant
Not significant
Indicates the wash tank level at the time of event recording.
Indicates the air gap level at the time of event recording.
Indicates the duo rinse level at the time of event recording.
Indicates the wash tank level at the time of event recording.
Indicates the prewash tank level at the time of event recording.
of event recording.
number.
Indicates the prewash tank level at the time of event recording.
Indicates the prewash tank level at the time of event recording.
Indicates the prewash tank temperature at the time of event recording.
Indicates the prewash tank temperature at the time of event recording.
Not significant
Not significant
Not significant
Indicates the prewash tank level at the time of event recording.
Not significant
Not significant
Not significant
Indicates the CU temperature at the time of event recording.
Indicates the CU temperature at the time of event recording.
event recording.
measured.
Indicates the drying tunnel temperature at the time of event recording.
Indicates the drying tunnel temperature at the time of event recording.
DOC. N. 5956.573.02 Page 24 / 80