Technical Bulletin no:
Date: Issuer: Factory:

Subject

Model
Problem
Reason
Action in Factory
D02-D04
CGX2004-17 (page 1 of 2), 2nd
04 May 2005 R. Sartor (DWS Customer Support) DW Vallenoncello - Italy

Peristaltic Dispensers after Long Storage

Undercounter and Hood Type with peristaltic rinse aid dispenser (atmospheric boiler only) and/or peristaltic detergent dispenser.
The motor does not turn (or poor wash/rinse results) just after the machine installation or the replacement of a dispenser.
The required torque is too high in case of local plastic deformation of the peristaltic hose. This plastic deformation always happens when the rollers holder is in the “12 o’clock” position and dispensers have been in storage for more than 15 days.
ASAP a dispenser motor with higher torque will be introduced. In the meanwhile we have introduced following sheet in every machine with a peristaltic dispenser:
ELECTROLUX PROFESSIONAL SPA MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30 33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30 33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
++39 0434 380643 riccardo.sartor@electrolux.it
Action in Field
chemical spare part code material colour dispenser markets
Rinse Aid
Detergent 049419
Follow instructions above every time the motor does not start turning. If the peristaltic hose is such squeezed that is deformed permanently, please,
remember that hoses have been available as spare part since year 1999 as follow:
peristaltic hose
049418
Sekobrill
Santoprene
semi-transparent
white
049625 World-wide 0L0506 North America 049624 World-wide 0L0507 North America