Identification: 
Technical  
Bulletin no: 
Date: 
Issuer: 
Factory: 
Subject 
Model 
Problem 
Reason 
Actions in 
Field 
D06 
CGX2007-18 (page 1 of 1), 1st ed. 
06 July 2007  
R. Sartor (DWS Customer Support)  
DW Vallenoncello - Italy 
Max Motor Current in WTM & RTC/WTC
Modular Rack Type range (Electrolux WTM series) and Compact Rack Type 
range (Electrolux WTC series and Zanussi RTC series). 
The parameter Max Motor Curr. (in WTM) / GCU (in RTC/WTC) is not equal 
to 35 at the delivery while the service manual says it’s the factory setting 
(default): 
. 
The value 35 (= 3.5 A of current load) is an overall average of all models, from 
the smallest capacity (RTC90 / WTC90) to the biggest capacity (WTM300 with 
900 mm dryer). 
The parameter is set during the functional test in factory according to the 
actual value of motor current load (that may change also for the same model). 
The parameter Max Motor Curr. (in WTM) / GCU (in RTC/WTC) has to be 
checked during the commissioning even because it has to be increased in 
case of dishwashing driven handling systems. 
The service manual contains the procedure to set correctly the parameter 
Max. motor curr. / GCU: 
1. Wait until the machine, complete with tables, is ready for a wash cycle. 
2. Start a wash cycle and read the current absorbed by the gear motor (refer 
to paragraph A1 “DISPLAY OF AUXILIARY VALUES”). 
3. Add 2 to the read value (e.g. if “Motor current” = 34 ---> 34+2=36 dA). 
4. Set the “Max. motor curr.” parameter with the value thus obtained. 
ELECTROLUX PROFESSIONAL SPA 
MAILING ADDRESS  TELEPHONE  WEBSITE  VAT NO. 
VIA SEGALUZZA, 30 
33170 PORDENONE - ITALY 
OFFICE ADDRESS  TELEFAX  E-MAIL ADDRESS   
VIA SEGALUZZA, 30 
33170 PORDENONE - ITALY 
Share more of our thinking at www.electrolux.com 
++39 0434 380650  www.electrolux.com  00072220932 
++39 0434 380636 
++39 0434 385646 
riccardo.sartor@electrolux.it