Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
Subject
Model
Problem
Reason
Actions in
Factory
D03-D04-D05
CG2007-19 (page 1 of 2), 1st ed.
31 July 2007
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Contactor for Boiler Heater in UW, HT and PW
Front Loading (LU7 / WTU40), Hood Type medium capacity (LS9 / WT55),
Hood Type high capacity with 9 kW boiler power (WT65 / Ecotemp12) and
Manual Pot & Pan Washer (PW1M-2M / WT830M-850) ranges.
Stuck main board relays for boiler heater.
The current load has exceeded the maximum allowed current load (16 A).
This usually happens when the voltage supply for the machine is higher than
specified (e.g. three-phase 400 V +10% = 440 V or single-phase 230 V +10%
= 253V).
Since serial number 73100001 we have introduced a contactor between main
board and boiler heater. Therefore the electrical wiring harnesses change as
follow:
Model
OLD
el. wiring
NEW
el. wiring
Additional
contactor
LU7 / WTU40 0L0732 0L0732 (638678201)
LU7WS / WTU40WS 0L1444 0L1444 (638685201)
LS9 / WT55 638679001 0L1414
0L0467
WT65 with 9 kW boiler power 0L0466
PW1M-2M 0L0619 0L0619 (638668005)
WT830M-850M 0L0469 0L0469 (638672702)
Hood Type high capacity with 10.5 kW boiler power (LS14EA / WT65E) and Automatic Pot & Pan
Washer (WT830EA-850EA) have had the contactor for boiler heater since their production start.
(already in use for LS14 / WT65 with
10.5 kW boiler power)
0L0285 (50Hz)
0L0286 (60Hz)
0L0430 (Japan)
none
(see below)
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
++39 0434 380636
++39 0434 385646
riccardo.sartor@electrolux.it
Share more of our thinking at www.electrolux.com
There’s not an additional contactor in Pot & Pan Washer.
The boiler heater is connected to one of two contactors that is not longer
needed for the tank heater (the tank heater has internal thermo-fuse so it does
not need double contactor):
Actions in
Field
OLD NEW
Apart from Pot & Pan Washer, the additional contactor can be retrofitted only
with the new electrical wiring harness.
Share more of our thinking at www.electr olux.c om
2