Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
Subject
Model
Problem
Reason
D02-D04
CGX2004-05 (page 1 of 1), 1st ed.
25 May 2004
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Boiler Heater in UC and in HT (North America models)
Undercounter double skin (LS6AH / WT30H) and Hood Type high capacity
(LS14H / WT65H) for North America.
Risk of terminal sealing breaks whereas the thermo-sensor (internal overheat
protection) is fitted.
North America models’ boiler heaters have stud-bolt terminals for eyelet
connectors where the terminals are liable to be turned. The thermo-sensor
sealing (that protects heating elements from outside humidity) can be broken
in case of too high torque.
92° ± 0.5°
Action in
Field
The allowed torque is 1.2 Nm = 0.885 lbf feet (maximum).
Alternatively, block the fixed nut (welded on boiler heater terminals) and
tighten the lock-nut:
The risk is non-existent for boiler heaters with faston and boiler heaters with
stud-bolt but without internal thermo-sensor.
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
++39 0434 380636 riccardo.sartor@electrolux.it