User Interface in UC, FL, HT and PW
D02-D03-D04-D05
CGX2007-24 (page 1 of 2)
Model
Undercounter LS5 / WT4 and LS6E / WT30E, Front Loading LU7 / WTU40, Hood Type LS10EA-14EA / WT65E and Pot&Pan Washer PW1M-2M / WT830M-850M / WT830EA-850EA.
Problem
Dead or not starting cycle.
Reason
Moisture or broken switch (push button)
Action in Factory
From serial number 74900001 (for UC) / 75000001 (for FL, HT and Automatic P&PW) we have introduced plastic box with embedded extensions for switches:
Painted UI Tall switch Plastic actuactor
Painted UI + plastic box Short switch Integrated plastic actuactor
ELECTROLUX PROFESSIONAL SPA MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30 33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30 33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
++39 0434 380636 ++39 0434 385646
riccardo.sartor@electrolux.it
Share more of our thinking at www.electrolux.com
Technical Bulletin (User Interface).doc

WHERE

PW1-2 / WT830-850
WT65
WT830EA-850EA
LS14EA
LS5 / WT4 &
LS6E / WT30E
(Until s/no. 52300099)
LS5 / WT4 &
LS6E / WT30E
(From s/no. 52400001)
LS9 / WT55 machines have not been involved in this change since their user interface will be soon out of production (LS14 / WT65 and LS9 / WT55 will have the same user interface).
OLD code
(RoHS compliant)
0L1240
0L1237
0L1242
0L1241
NEW code
(user interface + plastic box)
not available yet
0L1627
(UI 0L1566 + PB 0L1568)
not available
0L1626
(UI 0L1565 + PB 0L1567)
NEW code
(user interface only)
NEW code
(plastic box only)
Not available yet Not available yet
0L1566
(user interface only)
0L1568
(plastic box only)
not available not available
0L1565
(user interface only)
0L1567
(plastic box only)
LS5WS / WT4WS

LS9 / WT55

Action in Field
0L1235
not available
not available not available
For time being the new user interface 0L1627 does not fit in Front Loading Pot&Pan Washer machines because of interference with studs. A new frontal panel will be soon released.
New user interfaces with plastic box are interchangeable towards old user interfaces unless by taking away all plastic extensions 002670 and all brass spacers 088653 from machines with old user interface.
Be aware that new user interfaces cannot be used without the plastic box. Therefore new user interfaces without plastic box are NOT
interchangeable towards old user interfaces.
However you don’t need to replace user interface and plastic box in case of failure so also spare part codes for new user interface without plastic box are available (see table above).
Remove brass spacers to fit new
user interface with plastic box