PROFESSIONAL LAUNDRY
Industrial Ironers
IC44819, IC44821, IC44825, IC44828, IC44832 R/LF
Features and benefits
• Easy-to-use electronic control panel, RABC
(Risk Analysis and Biocontamination Control –
EN 14065) compatible
• DIAMMS (Direct Ironer Advanced Moisture
Management System); Automatic speed adjustment
with moisture sensors to ensure a perfect result
• Spring loaded pressure roll ensures outstanding
ironing quality
• Return feed, can be installed close to a wall for
maximum space utilisation (basic and LF models)
• Labour saving automatic Length-Folding device
(LF model)
• Rear delivery (R model)
• Fully encased machine for maximum workplace
safety and energy saving
• Finger guard protection provides additional safety for
operators
• Durable ironing belts made of Nomex
withstand temperatures above 430°F
®
which can
Main specifications
Capacity*, max. water evaporation** gallon/h
Cylinder, diameter (gas/steam) mm
inch
length mm
inch
Ironing speed ft/min
Heating, steam (130 psi) lb/h
gas Btu/h (kW)
* 50% residual moisture content cotton 6.35 oz/ft2 and 100% cylinder use (ISO 9398-1).
** Steam/gas.
• Nickel-plated cylinder prevents rust and improves
lifetime
• Maintenance free ceramic gas burner minimizes
downtimes. 20% more efficient than regular blue flame
burners. A unique and patented burner by Electrolux
Main options
• Multi-layer cylinder DubixiumTM for increased
production gas heated machines
• CMIS (Certus Management Information System)
connection for traceability according to
European Standard EN14065
IC44819 IC44821 IC44825 IC44828 IC44832
15/9.3 16.6/9.8 19.8/12.2 21.4/13.5 24.6/15.6
479/457 479/4 57 479/457 479/4 57 479/457
29.5/18 29.5/18 29.5/18 29.5/18 29.5/18
1910 2120 2540 2750 3170
75 3/16 83 7/16 100 108 1/4 124 13/16
4.9-29.5 4.9-29.5 4.9-29.5 4.9-29.5 4.9-29.5
183 203 243 271 311
133100(39) 150100(44) 177400(52) 191100(56) 221800(65)
Certified in accordance with UL/ETL standards.
Electrical connections*
IC44819 IC44821 IC44825 IC44828 IC44832
Heating Voltage
Gas, 208-240V 3AC 60 Hz kW(A)
steam 400-415V 3AC 50/60 Hz kW(A)
2 (15) 2 (15) 2 (15) 2 (15) 2 (15)
2 (15) 2 (15) 2 (15) 2 (15) 2 (15)
Steam, gas and air connections
Steam inch
Rec. steam pressure psi
Condensate inch
Gas inch
Gas pressure,
natural gas (G20/G25) psi
propane (G31) psi
Air outlet ø mm/inch
Evacuated air
gas ft
el, steam ft
Pressure drop max. psi
Sound levels
Airborne sound level
dB(A)
3/4 3/4 3/4 3/4 3/4
130 130 130 130 130
3/8 3/8 3/8 3/8 3/8
3/4 3/4 3/4 3/4 3/4
0.29/0.36 0.29/0.36 0.29/0.36 0.29/0.36 0.29/0.36
0.54/0.73 0.54/0.73 0.54/0.73 0.54/0.73 0.54/0.73
160 / 6 5/16 160 / 6 5/16 160 / 6 5/16 160 / 6 5/16 160 / 6 5/16
3
/h
28252 29311 33549 34608 35668
3
/h
26133 26133 31077 32489 33902
0.03 0.03 0.03 0.03 0.03
65 65 65 65 65
Heat emission
% of installed power, max.
Shipping data, (LF models)**
net, kg
net, lbs
Shipping volume, m
basic & LF/R models
Dimensions in mm / inch
A Width
B Depth
C Height
D
E R model only
F R model only
G R model only
H
I Ironing width
K
L
3 3 3 3 3
700/840 750/890 860/980 940/1060 1040/1150
1543/1852 1654/1962 1896/2161 2072/2337 2293/2535
3
4.5/6.8 4.8/6.7 5.4/7.6 5.6/8.0 6.2/8.9
3
ft
159/240 170/237 191/269 198/283 219/314
2575 / 101 3/8 2785 / 109 5/8 3205 / 126 3/16 3415 / 134 7/16 3835 / 151
1070 / 42 1/8 1070 / 42 1/8 1070 / 42 1/8 1070 / 42 1/8 1070 / 42 1/8
1270 / 50 1270 / 50 1270 / 50 1270 / 50 1270 / 50
950 / 37 3/8 950 / 37 3/8 950 / 37 3/8 950 / 37 3/8 950 / 37 3/8
670 / 26 3/8 670 / 26 3/8 670 / 26 3/8 670 / 26 3/8 670 / 26 3/8
800 / 31 1/2 800 / 31 1/2 800 / 31 1/2 800 / 31 1/2 800 / 31 1/2
840 / 33 1/16 840 / 33 1/16 840 / 33 1/16 840 / 33 1/16 840 / 33 1/16
1050 / 41 5/16 1050 / 41 5/16 1050 / 41 5/16 1050 / 41 5/16 1050 / 41 5/16
1910 / 75 3/16 2120 / 83 7/16 2540 / 100 2750 / 108 1/4 3170 / 124 13/16
355 / 14 355 / 14 355 / 14 355 / 14 355 / 14
190 / 7 1/2 190 / 7 1/2 190 / 7 1/2 190 / 7 1/2 190 / 7 1/2
1 Control panel
2 Exhaust connection
3 Steam connection
4 Condensate connection
5 Electrical connection
6 Gas connection
* Other voltages available, see installation manual.
** Average data. Crated weight/shipping volume depends on configuration.