Electrolux EW30GC55PB1, EW30GC55PS1, EW30GC60PS1, EW30GC60PS2, EW30GC60PS3 Installation Guide

...
GAS COOKTOP INSTALLATION INSTRUCTIONS
H
A
B
E
30” Min. * (76.2 cm)
F
D
C
(For 30" & 36" Models)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
FOR YOUR SAFETY: — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Gas Cooktop Dimensions
Gas Cooktop Cutout Dimensions
Figure 1
PRODUCT DIMENSIONS
MODEL A. WIDTH B. DEPTH C. HEIGHT D. BOX WIDTH E. BOX DEPTH
30" Gas Cooktop 30 (76,2) 21 ¾ (55,2) 4 ¼ (10,8)
36" Gas Cooktop 36 (91,4) 21 ¾ (55,2) 4 ¼ (10,8)
MODEL MINIMUM MAXIMUM MINIMUM MAXIMUM BELOW COOKTOP
30" Gas Cooktop 36" Gas Cooktop
All dimensions are stated in inches and (cm).
Dimension H includes a 5" (12,7 cm) space underneath the cooktop for connection to gas supply line.
F. WIDTH G. DEPTH H. HEIGHT
27 ¼ (69,2) 28 ½ (72,4) 19 1/8 (48,6) 19 ¾ (50,2) 8 (20,3) 33 7/8 (86,1) 34 ¼ (87) 19 1/8 (48,6) 19 ¾ (50,2) 8 (20,3)
CUTOUT DIMENSIONS
NOTE: Wiring diagrams for this cooktop are enclosed in this booklet
Printed in China
27 (68,6) 19 (48,3)
33 ¼ (84,5) 19 (48,3)
A01705106 (1609) Rev. A English - pages 1-9
Español - páginas 10-18
Français - pages 19-27
Wiring Diagram 28
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
Important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing the cooktop.
2. Remove all packing material before connecting the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Note: For operation at 2000 ft. elevations above see level, appliance rating shall be reduced by 4 percent for each additional 1000 ft.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for future reference.
IMPORTANT SAFETY INSTRUCTIONS
Installation of this cooktop must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 in the United States, or in Canada, with the Canadian Fuel Gas Code, CAN/CGA B149 and CAN/CGA B149.2.
• When installed in a manufactured (mobile) home
installation must conform with the Manufactured Home Construction and Safety Standard, title 24 CFR, part 3280 [Formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD (part
280)] or, when such standard is not applicable, the Standard for Manufactured Home Installation, ANSI/ NCSBCS A225.1 or with local codes where applicable.
This cooktop has been design certified by CSA International. As with any appliance using gas and generating heat, there are certain safety precautions you should follow. You will find them in the Use and Care Guide, read it carefully.
• Air curtain or other overhead hoods, which operate by blowing a downward air flow on to a range, shall not be used in conjunction with gas ranges other than when the hood and range have been designed, tested and listen by an independent test laboratory for use in combination with each other.
Be sure your cooktop is installed and grounded properly by a qualified installer or service technician.
This cooktop must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No. 70—latest edition in the United States, or in Canada, with the Canadian Electrical Code, CSA C22.1 Part 1.
The burners can be lit manually during an electrical power outage. To light a burner, hold a lit match to the burner head, then slowly turn the Surface Control knob to LITE. Use caution when lighting burners manually.
Do not store items of interest to children in cabinets above the cooktop. Children could be
seriously burned climbing on the cooktop to reach items.
To eliminate the need to reach over the surface
burners, cabinet storage space above the burners should be avoided.
Adjust surface burner flame size so it does not extend beyond the edge of the cooking utensil.
Excessive flame is hazardous.
Never use your cooktop for warming or heating the room. Prolonged use of the cooktop without adequate ventilation can be hazardous.
Do not store or use gasoline or other flammable
vapors and liquids near this or any other appliance. Explosions or fires could result.
The electrical power to the cooktop must be shut off while gas line connections are being made. Failure to do so could result in serious injury or death.
2
13" (33 cm) Max. Depth For Cabinet Installed Above Cooktop.
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
A
18" Min.
(45,7 cm)
B Minimum Distance Between
Rear Edge of Cutout and Nearest Combustible Surface Above Countertop.
Clearance
30" (76,2 cm) Min. Clearance Between the Top of the Cooking Platform and Unprotected Wood or Metal Cabinet
C
24" (61 cm)
To eliminate the risk of burns or fire from reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12,7 cm) beyond the bottom of the cabinets.
C
Allow a minimum of 6½" (16,5 cm) below the countertop for drawer. Make sure there will be no interference with gas or electrical connection.
MODEL A. B. Min. distance between
rear edge and nearest
combustible surface
above 30" Cooktop 30" (76,2 cm) 2 ½" (6,4 cm) 9" (22,9 cm) 36" Cooktop 36" (91,4 cm) 2 ¾" (7 cm) 9" (22,9 cm)
C. Min. distance from
left side and min. clear-
ance from right side
Figure 2 – CABINET DESIGN
3
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
Typical Under Counter Installation of an Electric Built-in
Oven with a Cooktop Mounted Above
All mounting hardware must be used to secure the built-in oven to the cabinets. Refer to the built-in oven installation instructions.
Junction box must be located approx. 3" (7,6 cm) to the left of the built-in oven cutout.
208/240 Volt grounded junction box for built-in oven.
This cooktop may be installed over certain built-in electric oven models.
Side filler panels are necessary to isolate the unit from adjoining cabinets. Panel height should allow for installation of approved cooktop models. See "Typical Gas Cooktop Installation Over an Electric Built-in Oven Installed Under the Counter" on next page.
36"
(91,4 cm)
Min.
Cut an opening in wood base minimum 4" (10,2 cm) x 4" (10,2 cm) to route armored cable to junction box.
* If no cooktop is installed
directly over the oven unit, 5" (12,7 cm) maximum is allowed.
OVEN SIZE
30"
(76,2 cm)
27"
(68,6 cm)
Unit will overlap cutout (minimum) edges by 1" (2.5cm)
CUTOUT DIMENSIONS (INCHES (cm))
E F
Min.
27 ¼"
(69,2 cm)
27 ¼"
(69,2 cm)
Figure 3
4 1/2" (11,4 cm)
Max.*
Max.
28 ¼"
(71,8 cm)
28 ¼"
(71,8 cm)
Min.
28 ½"
(72,4 cm)
24 7/8"
(63,2 cm)
Use 3/4" (1,9 cm) plywood, installed on two runners, flush with toe plate. Base must be capable of supporting 150 pounds (68 kg) for 27" models and 200 pounds (90 kg) for 30" models.
Max.
29"
(73,7 cm)
25 ¼"
(64,1 cm)
G
23 ½"
(59,7 cm)
23 ½"
(59,7 cm)
4
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
Typical Gas Cooktop Installation Over an Electric Built-in
Oven Installed Under the Counter
18" (45,7 cm) Max.
GAS COOKTOP
Manifold Pipe
Flexible Connector
Wall Oven Cabinet
Cabinet sides or
filler panel
Cooktop
Flare Union
5
"
(12,7 cm)
"
(16,5 cm)
Min.
Flare
Union
120V/60Hz
Grounded
Outlet
Pressure Regulator
Manual Shutoff Valve
(To be accessible
for shut-off valve
operation)
Front view
4" (10,2 cm)
Right Side
of Cabinet
Wall Oven
Side view
Figure 4
5
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
Wall Outlet Location
To clamp down, insert an angle bracket into the slot on each side of the unit as shown. Run thumb screw up through the bracket, up against the bottom of the counter. Tighten until the unit draws down and is secure.
Provide an Adequate Gas Supply
This cooktop is designed to operate on natural gas at 4" of manifold pressure only.
A pressure regulator is connected in series with the manifold on the cooktop and must remain in series with the supply line.
For proper operation, the maximum inlet pressure to the regulator must be no more than 14" of water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at least 1" (or 2,5 kPa) greater than the regulator manifold pressure setting. The regulator is set for 4" of manifold pressure, the inlet pressure must be at least 5".
The gas supply line to the range should be 1/2" or 3/4" pipe.
Figure 5
Cooktop Installation
1. Visually inspect the cooktop for damage.
2. Set the cooktop into the countertop cutout. NOTE: Do not use caulking compound; cooktop should be removable for service when needed.
Granite countertop Installation Kit
A Granite Countertop Installation kit # 903103-9010 can be ordered through a Service Center or by phone at 1-877-
ELECTROLUX (1-877-435-3287).
Clamp Down Information
Once the cooktop is installed in the counter opening, you must clamp the unit down as shown.
Seal
Cooktop
Countertop
Angle Bracket
LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/ Propane gas. It is shipped from the factory for use with natural gas.
A kit for converting to LP gas is supplied with your cooktop. The kit is marked "FOR LP/PROPANE GAS CONVERSION".
The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion.
Failure to make the appropriate conversion can result in serious personal injury and property damage.
Important: Remove all packing material and literature
from cooktop before connecting gas and electrical supply to cooktop.
Figure 6
Thumb Screw
6
Loading...
+ 13 hidden pages