INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
FOR YOUR SAFETY:
— Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
NOTE: Wiring diagrams for this cooktop are enclosed in this booklet
Printed in China
27 (68,6)19 (48,3)
33 ¼ (84,5)19 (48,3)
A01705106 (1609) Rev. A English - pages 1-9
Español - páginas 10-18
Français - pages 19-27
Wiring Diagram 28
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
Important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the cooktop.
2. Remove all packing material before connecting the
electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Note: For operation at 2000 ft. elevations above see
level, appliance rating shall be reduced by 4 percent
for each additional 1000 ft.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for
future reference.
IMPORTANT SAFETY
INSTRUCTIONS
Installation of this cooktop must conform with local
codes or, in the absence of local codes, with the National
Fuel Gas Code ANSI Z223.1/NFPA 54 in the United
States, or in Canada, with the Canadian Fuel Gas Code,
CAN/CGA B149 and CAN/CGA B149.2.
• When installed in a manufactured (mobile) home
installation must conform with the Manufactured
Home Construction and Safety Standard, title 24 CFR,
part 3280 [Formerly the Federal Standard for Mobile
Home Construction and Safety, title 24, HUD (part
280)] or, when such standard is not applicable, the
Standard for Manufactured Home Installation, ANSI/
NCSBCS A225.1 or with local codes where applicable.
This cooktop has been design certified by CSA
International. As with any appliance using gas and
generating heat, there are certain safety precautions you
should follow. You will find them in the Use and Care
Guide, read it carefully.
• Air curtain or other overhead hoods, which operate
by blowing a downward air flow on to a range, shall
not be used in conjunction with gas ranges other
than when the hood and range have been designed,
tested and listen by an independent test laboratory
for use in combination with each other.
• Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
• This cooktop must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA
No. 70—latest edition in the United States, or in
Canada, with the Canadian Electrical Code, CSA
C22.1 Part 1.
• The burners can be lit manually during an
electrical power outage. To light a burner, hold a
lit match to the burner head, then slowly turn the
Surface Control knob to LITE. Use caution when
lighting burners manually.
• Do not store items of interest to children in
cabinets above the cooktop. Children could be
seriously burned climbing on the cooktop to reach
items.
• To eliminate the need to reach over the surface
burners, cabinet storage space above the burners
should be avoided.
• Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessive flame is hazardous.
• Never use your cooktop for warming or heating the room. Prolonged use of the cooktop without
adequate ventilation can be hazardous.
• Do not store or use gasoline or other flammable
vapors and liquids near this or any other
appliance. Explosions or fires could result.
The electrical power to the cooktop
must be shut off while gas line connections are
being made. Failure to do so could result in serious
injury or death.
2
13" (33 cm)
Max. Depth
For Cabinet
Installed Above
Cooktop.
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
A
18" Min.
(45,7 cm)
B Minimum Distance Between
Rear Edge of Cutout and Nearest
Combustible Surface Above
Countertop.
Clearance
30" (76,2 cm)
Min. Clearance
Between
the Top of
the Cooking
Platform and
Unprotected
Wood or Metal
Cabinet
C
24" (61 cm)
To eliminate
the risk of burns or fire from
reaching over heated surfaces,
cabinet storage space located
above the cooktop should be
avoided. If cabinet storage is
provided, risk can be reduced
by installing a range hood
that projects horizontally a
minimum of 5" (12,7 cm)
beyond the bottom of the
cabinets.
C
Allow a minimum of 6½" (16,5 cm) below
the countertop for drawer. Make sure
there will be no interference with gas or
electrical connection.
Typical Under Counter Installation of an Electric Built-in
Oven with a Cooktop Mounted Above
All mounting hardware must be
used to secure the built-in oven to
the cabinets. Refer to the built-in
oven installation instructions.
Junction box must
be located approx.
3" (7,6 cm) to the
left of the built-in
oven cutout.
208/240 Volt
grounded junction
box for built-in oven.
This cooktop may be
installed over certain
built-in electric oven
models.
Side filler panels are necessary to isolate
the unit from adjoining cabinets. Panel
height should allow for installation of
approved cooktop models. See "Typical
Gas Cooktop Installation Over an
Electric Built-in Oven Installed Under the
Counter" on next page.
36"
(91,4 cm)
Min.
Cut an opening in wood base minimum 4"
(10,2 cm) x 4" (10,2 cm) to route armored
cable to junction box.
* If no cooktop is installed
directly over the oven unit,
5" (12,7 cm) maximum is
allowed.
OVEN SIZE
30"
(76,2 cm)
27"
(68,6 cm)
Unit will
overlap
cutout
(minimum)
edges by
1" (2.5cm)
CUTOUT DIMENSIONS (INCHES (cm))
EF
Min.
27 ¼"
(69,2 cm)
27 ¼"
(69,2 cm)
Figure 3
4 1/2" (11,4 cm)
Max.*
Max.
28 ¼"
(71,8 cm)
28 ¼"
(71,8 cm)
Min.
28 ½"
(72,4 cm)
24 7/8"
(63,2 cm)
Use 3/4" (1,9 cm)
plywood, installed on
two runners, flush with
toe plate. Base must be
capable of supporting
150 pounds (68 kg) for
27" models and 200
pounds (90 kg) for 30"
models.
Max.
29"
(73,7 cm)
25 ¼"
(64,1 cm)
G
23 ½"
(59,7 cm)
23 ½"
(59,7 cm)
4
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
Typical Gas Cooktop Installation Over an Electric Built-in
Oven Installed Under the Counter
18" (45,7 cm) Max.
GAS COOKTOP
Manifold Pipe
Flexible Connector
Wall Oven Cabinet
Cabinet sides or
filler panel
Cooktop
Flare
Union
5
"
(12,7 cm)
6½
"
(16,5 cm)
Min.
Flare
Union
120V/60Hz
Grounded
Outlet
Pressure
Regulator
Manual Shutoff Valve
(To be accessible
for shut-off valve
operation)
Front view
4" (10,2 cm)
Right Side
of Cabinet
Wall Oven
Side view
Figure 4
5
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
Wall Outlet Location
To clamp down, insert an angle bracket into the slot
on each side of the unit as shown. Run thumb screw
up through the bracket, up against the bottom of the
counter. Tighten until the unit draws down and is secure.
Provide an Adequate Gas Supply
This cooktop is designed to operate on natural gas at 4"
of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
For proper operation, the maximum inlet pressure
to the regulator must be no more than 14" of water
column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least 1" (or 2,5 kPa) greater than the regulator manifold
pressure setting. The regulator is set for 4" of manifold
pressure, the inlet pressure must be at least 5".
The gas supply line to the range should be 1/2" or 3/4"
pipe.
Figure 5
Cooktop Installation
1. Visually inspect the cooktop for damage.
2. Set the cooktop into the countertop cutout.
NOTE: Do not use caulking compound; cooktop should
be removable for service when needed.
Granite countertop Installation Kit
A Granite Countertop Installation kit # 903103-9010 can
be ordered through a Service Center or by phone at 1-877-
ELECTROLUX (1-877-435-3287).
Clamp Down Information
Once the cooktop is installed in the counter opening,
you must clamp the unit down as shown.
Seal
Cooktop
Countertop
Angle
Bracket
LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LP gas is supplied with your
cooktop. The kit is marked "FOR LP/PROPANE GAS
CONVERSION".
The conversion must be performed by a qualified service
technician in accordance with the kit instructions and
all local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Important: Remove all packing material and literature
from cooktop before connecting gas and electrical
supply to cooktop.
Figure 6
Thumb
Screw
6
Loading...
+ 13 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.