Electric Built-In Range
EW30ES65GS
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
•
10200 David Taylor Drive •Charlotte, NC 28262 •1-877-4electrolux (1-877-435-3287)
•
electroluxappliances.com
CANADA
•
5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352
•
electroluxappliances.ca
EW30ES65G 03/14 © 2014 Electrolux Home Products, Inc.
30" Electric Built-In Range Specifications
•
Product Weight – 238 Lbs.
•
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz,
fused on both sides of line with ground. (If local code permits, range may
be connected by hard-wiring or by means of power supply cord kit.)
•
Connected Load (kW Rating) @ 240/208 Volts = 15.4/ 11.6 kW
•
Amps @ 240/208 Volts = 64.2/ 55.8 Amps
•
Recommended Circuit Breaker – 50 Amps
•
Always consult local and national electric codes.
•
Make sure wall coverings around range can withstand heat generated
by range.
•
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
•
Countertop MUST be level in all directions and adjustable range
height at least 1/16" greater than tallest cabinet height, to ensure metal
rangetop flange will fit properly on countertop edge.
•
When installing optional Backguard Kit, cutout depth of 21-3/4"
minimum / 22-1/8" maximum needs increased to 24".
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
•
Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than 1/4"
flame-retardant millboard covered with not less than No. 28 MGS sheet
steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. Allow
30" minimum clearance when cabinet is unprotected.
•
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
•
When installing range into existing cutout depth greater than 22-1/8",
optional 2" Rear Filler Kit available.
Countertop Preparation
For detailed preparation instructions, refer to installation guide on the web.
•
Flat square-finish (flat) countertop requires no preparation since rangetop
flange lays directly on countertop edge.
•
Formed front-edged countertops require front molded edge to be shaved
flat 3/4" from each front corner of opening.
•
Tile countertops may need cut back 3/4" from each front corner of
opening and/or rounded edge flattened.
•
For existing cutout width greater than 30-1/16" reduce the 3/4" overlap
dimension or for cutout width of 29", replace actual side trim panels with
smaller side trim panels, available with optional Side Trim Kit (refer to
detailed kit installation instructions).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
•
Grill / Griddle – (PN # 318251611).
•
2" Rear Filler Kit: S – (PN # 903113-901S).
•
Side Panel Kit: S – (PN # 903102-901S).
•
Backguard Kit: S – (PN # 903111-901S).
•
Side Trim Kit: S – (PN # 903110-901S).