Electrolux E30GC74GPS2, E36GC75GSS2, E36GC75GSS3, E36GC76GPS2, E36GC76GPS3 Installation Guide

iNSTALLATiON AND SERVICE MUST BE PERFORMED BY
A QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
-- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
For Standard Installation: i
Gas Cooktop Dimensions
Gas Cooktop Cutout Dimensions
2"(5,1cm) Dia.
Opening to route power
cable, Sealopening
routing power cable.
G
i i
:i:<:!iii:: ii
3" (7.6cm)
* 30" (76.2cm) min. for
unprotected cabinet and 24" (61cm) min. for cabinet
30"(76.2cm)
Min.*
with protected bottom surface.
C
4" X 4" (10.2cm x 10.2cm) ......
opening to route gas
supply. Seal opening after
routing gas line
F
H
i
Figure 1
**Note: D & E are critical to the proper installation of the cooktop. D reflects the
finished dimension. Due to the variation in countertop materials, it is recommended to
first undercut this dimension, and then adjust
it upon installation of the cooktop.
7V4
lcm)
36 (91.4) 357/8(91.1) 25 (63.5) 73/4(19.7) 35/5//6(91.3) 353/16(89.4) 351/8(89.2) 22 (55.9) 1//8(2.9) Max. 71/2(19.1)
30 (76.2) 297/8(75.9) 25 (63.5) 73/4(19.7) 29W16(76) 293/16(74.1) 29//8(74) 22 (55.9) 11/8(2.9) Max. 71/2(19.1)
All dimensions are stated in inches and (cm). NOTE: Wiring diagrams for this cooktop are enclosed in this booklet
318201493 (1002) Rev.A
English - pages 1-8
Espaflol - p_iginas 9-16
Francais- pages 17-23
Wiring Diagram page- 24
For Installation with the optional Stainless Steel Backsplash.
Gas Cooktop Dimensions
2"(5.1 cm)
9" (22.9cm) Optional
StainlessSteel Backsplash
* 30" (76.2cm) min. for
unprotected cabinet and 24" (61cm) min. for cabinet
with protected bottom surface.
30"(76.2cm)
Min.*
***Note: Applies only in case of countertop backwall.
4" X 4" (10.2cm x 10.2cm)
opening to route gas supply.
Seal opening after routing
gas line
2"(5.1cm) Dia.
Opening to route power
cable. Seal opening
routing power cable.
H
Gas Cooktop Cutout Dimensions
Do not slide unit into cabinet cutout, countertop materials, it is recommended to Protruding screws on the bottom of unit first undercut this dimension, and then adjust
may damage the bottom front finish. Figure 2 it upon installation of the cooktop.
F
**Note: D & E are critical to the proper installation of the cooktop. D reflects the
finished dimension. Due to the variation in
C
i
7¼" (18,4cm)
36(91.4) 357/8(91.1) 25(63.5) 73/4(19.7) 35/s//6(91.3)353//6(89.4)35//8(89.2) 22(55.9) 11/8(2.9)Max. 71/_(19.1) 351s/16(91.3) 30(76.2) 297/8(75.9) 25 (63.5) 73/4(19.7) 291s/16(76) 293/16(74.1) 291/8(74) 22 (55.9) 11/8(2.9) Max. 71/_(19.1) 29/s/16(76)
All dimensions are stated in inches and (cm).
important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing the cooktop.
2. Remove all packing material before connecting the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Note: For operation at 2000 ft. elevations above see level, appliance rating shall be reduced by 4 percent
for each additional 1000 ft.
Important Note to the Consumer Keep these instructions with your Use and Care Guide for
future reference.
Depth Adjustment Filler Kit This cooktop isdesigned to replace existing unit. If the
depth of your countertop opening is bigger than 71/4" (18.4cm) and lessthan 81/2'` (21.6cm) you can order a free filler kit by calling Service Center at 1-877-4ELECTROLUX (1-877-435-3287).
For 36" model: #903051-9010 For 30" model: #903051-9100
Optional Items Available:
A 9" (22.9cm) Stainless Steel Backsplash Kit
#903048-9010 for 36" model or #903048-9100 for 30" model.
A Black Knobs Kit #903049-9120 for 36" model or
#903049-9110 for 30" model.
Those kits can be order through the ServiceCenter at
1-877-4ELECTROLUX(1-877-435-3287). However all cost
related to those kits will be at customer charges.
This cooktop has been design certified by CSA International. As with any appliance using gas and generating heat, there are certain safety precautions you
should follow. You will find them in the Use and Care Guide, read it carefully.
* Be sure your cooktop is installed and grounded
properly by a qualified installer or service technician,
* This cooktop must be electrically grounded in
accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No, 70--latest edition in the United States, or in Canada, with the Canadian Electrical Code, CSA C22,1 Part 1,
* The burners can be lit manually during an
electrical power outage, To light a burner, hold a lit match to the burner head, then slowly turn the
Surface Control knob to LITE, Use caution when lighting burners manually,
* Do not store items of interest to children in
cabinets above the cooktop, Children could be seriously burned climbing on the cooktop to reach
items.
* To eliminate the need to reach over the surface
burners, cabinet storage space above the burners should be avoided.
o Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessiveflame is hazardous.
* Never use your cooktop for warming or heating
the room. Prolonged use of the cooktop without adequate ventilation can be hazardous.
* Do not store or use gasoline or other flammable
vapors and liquids near this or any other appliance, Explosions or fires could result.
IMPORTANT SAFETY INSTRUCTIONS
Installation of this cooktop must conform with local codes or, in the absence of local codes, with the National
Fuel Gas Code ANSI Z223.1/NFPA54--1atest edition in the United States, or in Canada, with the Canadian Fuel
Gas Code, CAN/CGA B149 and CAN/CGA B149.2.
* When installed in a manufactured (mobile) home
installation must conform with the Manufactured
Home Construction and Safety Standard, title 24 CFR,
part 3280 [Formerly the Federal Standard for Mobile
Home Construction and Safety, title 24, HUD (part
280)] or, when such standard is not applicable, the Standard for Manufactured Home Installation, ANSI/ NCSBCSA225.1 or with local codes where applicable.
The electrical power to the cooktop
must be shut off while gas line connections are being made, Failure to do so could result in serious injury or death,
3
13"(33cm)max.depth
forcabinetinstalledabove cooktop
30"(76.2cm)Min. ClearanceBetweenthe
TopoftheCooking PlatformandtheBottom
ofanUnprotectedWood orMetalCabinet "_.
24" (61cm) Min. w Bottom of Wood
or Metal Cabinet is Protected by Not
LessThan 1/8" Flame Retardant Millboard Covered With Not LessThan No. 28 MGS
Sheet Steel, 0.015" (0.4mm) Stainless Steel, 0.024" (0.6mm)
Aluminum or 0.020" (0.5mm) Copper
,eo
18" (45.7cm)
Min.
2" (5.1cm) min. distance between rear edge
of cutout and nearest combustible surface
above countertop
\
30" (76.2cm) min. clearance between
the top of the cooking platform and
the bottom of an unprotected wood or
metal cabinet.
24" (61,X_cm_ l
It is not recommended to use drawer underneath cooktop.
To eliminate the risk of burns
or fire from reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 7" (17.8cm) 36"(91.4cm) 36"(91.4cm)
beyond the bottom of the cabinets. 30"(76.2cm) 30"(76.2cm)
Figure 3 - CABINET DESIGN
9" (22.9 cm) 9" (22.9 cm)
5" (12.7 cm) 5" (12.7 cm)
Wall Outlet Location
_ 4 ,,_
(10.2cm)
Recommended area for 120V
grounded
outlet on rear _L_cENTRE 16" wall. _LINE (40.6cm)
OF UNIT
NOTE: If an : / outlet is not I
available, have one installed I
by a qualified i
technician. ____
Figure 4 OFUNIT
(12.7cm)
/
L
"_ CCENTR E
][,..LINE
The conversion must be performed by a qualified service technician in accordance with the kit instructions and
all local codes and requirements. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and property damage.
Important: Remove all packing material and literature from cooktop before connecting gas and electrical supply to cooktop.
Install Pressure Regulator Install the pressure regulator with the arrow on the regulator pointing up toward the unit in a position where you can reach the access cap.
Do not make the connection too tight.
The regulator is die cast. Overtightening may crack the regulator resulting in a gas leak and possible fire or explosion.
Manual GAS FLOW Pressure Shutoff Flare __ Flare Regulator
Valve Union Union
Provide an Adequate Gas Supply This cooktop is designed to operate on natural gas at 4" (10.2cm) of manifold pressure only.
A pressure regulator is connected in series with the manifold on the cooktop and must remain in series with the supply line.
For proper operation, the maximum inlet pressure to the regulator must be no more than 14" (35.6cm) of water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at least 1"(2.5cm) (or 2.5 kPa) greater than the regulator manifold pressure setting. The regulator is set for 4" (10.2cm) of manifold pressure, the inlet pressure must be
at least 5" (12.7cm). The gas supply line to the range should be 1/2" (1.3cm)
or 3/4" (1.9cm) pipe.
LP/Propane Gas Conversion This appliance can be used with Natural gas or LP/ Propane gas. It is shipped from the factory for use with natural gas.
A kit for converting to LPgas is supplied with your cooktop. The kit is marked "FOR LP/PROPANEGAS
CONVERSION".
Nipple Flexible
Off Connector
All connections must be wrench-tightened
Figure 5
Assemble the flexible connector from the gas supply pipe to the pressure regulator in the following order:
1. manual shutoff valve
2. 1/2" (1.3cm) nipple
3. 1/2" (1.3cm) flare union adapter
4. flexible connector
5. 1/2" (1.3cm) flare union adapter
6. 1/2" (1.3cm) nipple
7. pressure regulator
Use pipe-joint compound made for use with Natural and LP/Propane gas to seal all gas connections. If flexible connectors are used, be certain connectors are not
kinked.
Access
Cap
Thesupplylineshouldbeequippedwithanapproved shutoffvalve.Thisvalveshouldbelocatedinthesame
roomasthecooktopandshouldbeinalocationthat allowseaseofopeningandclosing.Donotblockaccess totheshutoffvalve.Thevalveisfor turningonor shuttingoffgastotheappliance.
Open position
Figure 6
Electrical Requirements
120 volt, 60 Hertz, properly grounded branch circuit protected by a 15 amp circuit breaker or time delay fuse. Do not use an extension cord with this cooktop.
Grounding Instructions IMPORTANT Pleaseread carefully.
For personal safety, this appliance must be properly grounded.
The power cord of this appliance isequipped with a 3-prong (grounding) plug which mates with a standard 3-prong grounding wall receptacle (see Figure 7) to minimize the possibility of electric shock hazard from the appliance.
The wall receptacle and circuit should be checked by a qualified electrician to make sure the receptacle is properly grounded.
Preferred Method
Once the regulator is in place, open the shutoff valve in the gas supply line. Wait a few minutes for gas to move through the gas line.
Check for leaks. After connecting the cooktop to the gas supply, check the system for leaks with a manometer. If a manometer is not available, turn on the gas supply and use a liquid leak detector (or soap and water) at all
joints and connections to check for leaks.
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame may result in a fire or explosion.
Tighten all connections if necessary to prevent gas leakage in the cooktop or supply line.
Check alignment of control knob valves after connecting the cooktop to the gas supply to be sure the cooktop manifold pipe has not moved. A misalignment could cause the valve stems to rub on the control panel, resulting in a gas leak at the valve.
Disconnect this cooktop and its individual shutoff valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa or 14" (35.6 cm) water column).
Isolate the cooktop from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig
(3.5 kPa or 14" (35.6 cm) water column).
Grounding type wall receptacle
g prong.
Power supply cord with 3-prong grounding plug.
Figure 7
Where a standard 2-prong wall receptacle is installed, it is the personal responsibility and obligation of the consumer to have it replaced by a properly grounded 3-prong wall receptacle.
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Disconnect electrical supply cord from
wall receptacle before servicing cooktop.
Cooktop Installation
1. Visually inspect the cooktop for damage.
2. If you are installing the optional Stainless Steel
backsplash, first fix it at the back of the cooktop using the screws supplied with the kit and follow the
instructions attached.
3. Set the cooktop into the countertop cutout.
NOTE: Do not use caulking compound; cooktop should be removable for service when needed.
Check Operation RefertotheUseandCareGuidepackagedwiththe cooktopforoperatinginstructionsandforcareand cleaningofyourcooktop.
Donottouchtheburners.Theymaybe
hotenoughtocauseburns. 1,BurnerBasesandBurnerCaps
Thisrangeisequippedwithsealedburnersasshown (Figure8).Allpiecesareattheirplace.Takenotewhere theyare.Removeallpackagingmateriallocated
underthe DualSurfaceburnerhead,Makesurethe burnerisproperlyalignedandleveled.
NOTE:Therearenoburneradjustmentsnecessaryon thisrange.
30" Model
Bur_er Cap
Burner Cap
Fixed Burner Ring
Fixed Burner Ring
and Burner Base
4. Adjust the "LOW" Setting of Regular Burner (see figure 8) on the Surface Burner Valves (Figure 9): a. Push in and turn control to LITEuntil burner ignites. b. Quickly turn knob to LOWEST POSITION. c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob and
decorative ring.
e. Insert athin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size can be increased or decreased by turning the
screw. Turn counterclockwise to increase flame size. Turn clockwise to decrease flame size. Adjust flame
until you can quickly turn knob from LITEto LOWEST POSITIONwithout extinguishing the flame. Flame
should be as small as possible without going out.
Note: Air mixture adjustment is not required on surface burners.
Dual Surface
Burner
Figure8
2. Turn on Electrical Power and Open Main Shutoff Gas Valve
3. Check the Igniters
Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power. Tocheck for proper lighting:
a.Push in and turn a surface burner knob to the LITE
position. All electronic surface ignitors will spark at the same time. However, only the burner you are turning on will ignite.
b.The surface burner should light once the flow of gas
reached the surface burner. Each burner should light within four (4) seconds in normal operation after air has been purged from supply lines. Visually check that
burner has lit.
c. Once the burner lights, the control knob should be
rotated out of the LITEposition. There are separate ignition devices for each burner. Try each knob separately until all burner valves have been
checked.
Regular Burner
Figure 9
7
5. Adjustthe "LOW"Settingof theDualBurner (seeFigure8)on theSurfaceBurnerValve(Figure
10): Note:Onthedualvalvethelowsettingof eachportion
(rearportionofbridgeburnerandthecenterportionof bridgeburner)shouldbeadjustedindividually. a. Pushinandturncontrolto LITEuntiltherearportion
ofthebridgeburnerignitesonly. b. Quicklyturnknobto LOWESTPOSITION. c. Ifburnergoesout,resetcontroltoOFF.
d. Removethesurfaceburnercontrolknob. e. Theinnerportionofthedualburnerflamesizecanbe
increasedordecreasedbyturningscrewA (seeFigure
19).UsescrewBto adjusttheflamesizeoftheouter portionofthedualburner.Turncounterclockwise
thescrewto increaseflamesize.Turnclockwisethe
screwto decreaseflamesize.Adjustflameuntilyou
canquicklyturnknobfromLITEtoLOWESTPOSITION
withoutextinguishingtheflame.Flameshouldbeas
smallaspossiblewithoutgoingout. Note:Airmixtureadjustmentisnotrequiredonsurface
burners.
When All Hookups are Complete
Make sure all controls are left in the OFFposition.
Before You Call for Service
Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide.
It may save you time and expense. The list includes common occurrences that are not the result of defective
workmanship or materials in this appliance. Refer to your Use and Care Guide for Electrolux Service
phone numbers, or call 1-877-4ELECTROLUX (1-877- 435-3287).
Figure 10