Electrolux E30GC74GPS User Manual

Page 1
Gas Slide-In Cooktop
E30GC74GPS
Min-2-Max™Burners
Burner configuration includes two versatile Min-2-Max from 18,000 to 450 BTUs. Thanks to the double ring configuration, you can simmer sauces or bring water to a boil. You decide the level of heat output by a simple turn of the knob.
Four Sealed Burners
Versatile sealed burner configuration provides the utmost in cooking flexibility. Includes: two 18,000-450 BTU Min-2-Max 14,000 BTU Power Burner Precision Burner
sealed burners delivering anywhere
burners, one
.
and one 5,000 BTU
Designed for the well-lived home.
30" GAS SLIDE-IN COOKTOP
Configuration
FEATURES
Formed Stainless Steel Platform Large Professional Skirted Knobs with Bezel Min-2-Max™Dual-Ring Sealed Burner (BTU) Sealed Power Burner™(BTU) Sealed Precision Burner™(BTU) Linear Flow Burner Valves Electronic Ignition with Auto Re-Ignition Continuous Grates
ACCESSORIES
Griddle Wok Ring Simmer Plate 9" Stainless Steel Backsplash – 903048-9100 Black Knobs Kit – 903049-9110 Depth Adjustment Filler Kit * – 903051-9100
SPECIFICATIONS
Overall Exterior Dimensions –
Height Width
Depth Gas Inlet/ Power Supply Location Voltage Rating Connected Load (kW Rating) @120 Volts Electrical Cable Approved for Single Oven Combination Installation** Approved for Downdraft Vent Combination Installation** Product Weight Shipping Weight (Approx.)
* When replacing an existing cooktop with countertop cutout deeper than 7-1/4"
and less than 8-1/2", order free Depth Adjustment Filler Kit.
For use on adequately wired 120V, dedicated circuit having 2-wire service with
a separate ground wire. Appliance must be grounded for safe operation. ** Not approved to be used over any Electrolux ICON™Single Wall Oven. Approved to be
used in combination with an Electrolux ICON™Downdraft Vent. (Proper combination
installation will require cooktop power cord to be relocated.) NOTE: Always consult local and/ or national electric and gas codes. Refer to Product
Installation Guide for detailed installation instructions on the web at electroluxicon.com.
Specifications subject to change.
4 Sealed Burners
Yes 4 2 (18,000 – 450) 1 (14,000) 1 (5,000) 4 Yes 3
Included Included Included Optional Optional Optional
7-3/4" 29-7/8" 25" Right Rear 120V/ 60Hz /15A
0.001 Included No Yes 95 Lbs. 100 Lbs.
Sealed Cooktop Spill-Basin
Cleanup is convenient with a black porcelain­coated area beneath the burners to catch spills.
Professional-Style Controls
Large professional-feel, front-mounted control knobs provide easy and accurate settings. 270 degree rotation offers superior flame control. Optional black knobs available.
electroluxicon.com
Page 2
Gas Slide-In Cooktop
7
1
/4"
3
/8"
E30GC74GPS
13"
max.
cabinet
depth
Optional 9" stainless steel backsplash (attaches to wall)
1" min. recommended distance between rear edge of cutout and nearest combustible surface above countertop
2"
Side inset 5/8"
29 7/8"
29 15/16"**
30" min.
25"
71/2"
73/4"
30" min. for
unprotected cabinet
24" min. with
protected bottom
18" min.
**Applies only in case of countertop backwall
7" min. to nearest combustible wall (either side of unit)
surface
221/8"
3"
2" dia. opening to route power cable
21/2"
2"
Support
platform
1
29
/8"
29 3/16"*
29
15
/16"*
*Both cutout dimensions are
24"
1" countertop
11/8" max.
4" x 4" opening to route gas supply
is recommended to undercut finished dimension
critical to proper cooktop installation.
Due to variations in countertop materials it
15
/16" and adjust upon installation of cooktop.
29
overhang
30" Gas Slide-In Cooktop Specifications
Product Weight – 95 Lbs.
Voltage Rating –120V / 60Hz/15 Amp
Connected Load (kW Rating) @120 Volts = 0.001kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)
Amps @120 Volts = 0.008 Amps
Always consult local and/or national electric and gas codes.
Cooktop ships with 3/4" factory regulator.
Lp conversion kit supplied.
Plan installation to have electrical connection, gas shutoff valve, and pressure regulator accessible from front of cabinet. Locate 120V grounded outlet in a 4"W x 5"H area on rear wall, 16" above floor, aligned center with cooktop.
Cabinet and/or countertop must completely enclose recessed portion of cooktop. Respect cutout dimensions and clearances and ensure that all contact surfaces are solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No.28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
USA
250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287)
CANADA
E30GC74GPS 05/08 © 2008 Electrolux Home Products, Inc. Printed in the U.S.A.
5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352
electroluxicon.ca
Allow 1" minimum clearance between rear edge of cooktop and nearest combustible surface above countertop. If required clearance can not be maintained, then optional stainless steel backsplash or noncombustible backsplash material must be used – otherwise installation will require custom cabinet and countertop dimensions.
Allow 7" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit.
It is recommended that drawers not be used beneath cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood that projects horizontally a recommended minimum of 7" beyond bottom of cabinets.
Gas Slide-In Cooktop model E30GC74GPS is NOT approved to be used over any Electrolux ICON™ Single Wall Oven.
Gas Slide-In Cooktop model E30GC74GPS (without optional backsplash) is approved to be used in combination with an Electrolux ICON
Downdraft Vent. (Refer to Slide-In Cooktop/Downdraft Vent Countertop Preparation Specifications page and on web.) Proper combination installation will require cooktop power cord to be relocated to underside of unit. (For details, refer to 30" & 36" Gas Slide-In Cooktop Power Cord
Relocation Instructions on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
When replacing an existing cooktop with countertop cutout deeper than 7-1/4" and less than 8-1/2", order free Depth Adjustment Filler Kit – (903051-9100).
9" Stainless Steel Backsplash – (903048-9100).
Black Knobs Kit – (903049-9110).
electroluxicon.com
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Page 3
7
1
/4"
Slide-In Cooktop/Downdraft Vent Countertop Preparation
Countertop Preparation for 30" & 36" Slide-In Cooktop/Downdraft Vent Installation
For detailed cooktop and downdraft vent installation specifications, refer to model-specific product page and installation guide on web
E
13
2
/16"
C
D
1"countertop overhang
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktop A B C D E
E30GC74GPS* 29
*Proper combination installation will require cooktop power cord
to be relocated to underside of unit.
Gas Slide-In Cooktop Power Cord Relocation Instructions page.)
15
/16" 29 3/16" 22" 25 13/16" 27 1/2"
(For details, refer to 30" & 36"
Opening for
downdraft vent
1
7
/2"
B
A
E36DD75ESS/36" Cooktop Cutout Dimensions
36" Cooktops A B C D E
E36EC75DSS 35 E36EC75ESS 35 E36EC75HSS 35 E36GC75DSS* 35 E36GC75ESS* 35 15/16" 35 3/16" 22" 25 13/16" 33 3/4" E36GC75GSS* 35 E36GC76EPS* 35 E36GC76GPS* 35
15
/16" 35 3/16" 22" 25 13/16" 33 3/4"
15
/16" 35 3/16" 22" 25 13/16" 33 3/4"
15
/16" 35 3/16" 22" 25 13/16" 33 3/4"
15
/16" 35 3/16" 22" 25 13/16" 33 3/4"
15
/16" 35 3/16" 22" 25 13/16" 33 3/4"
15
/16" 35 3/16" 22" 25 13/16" 33 3/4"
15
/16" 35 3/16" 22" 25 13/16" 33 3/4"
Slide-In Cooktop/Downdraft Vent Countertop Preparation Specifications
For detailed Slide-In Cooktop installation, refer to model-specific product page and installation guide on web. Plan installation so that all required minimum clearances between cooktop, overhead cabinets and adjacent vertical walls are provided.
Position cooktop/vent cutout so all required minimum clearances are met.
Minimum flat countertop area must meet or exceed combined overall width and depth as shown.
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
Always consult local and/or national electric codes. Check local building codes for installation requirements, as they may vary per locale.
Proper combination installation will require 30" & 36" Gas Slide-In Cooktop power cord to be relocated to underside of unit. (For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation Instructions on web.)
Downdraft Vent Specifications
For detailed Downdraft Vent installations, refer to model-specific product page and installation guide on web.
Voltage Rating –120V / 60Hz/15 Amps
Connected Load (kW Rating) @120 Volts = 1.0kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)
Amps @120 Volts = 8.0 Amps
Vent unit outside of building only.
Vent must be installed in vertical orientation only.
1,600 CFM remote exhaust blower (part number 5304444802) included with vent – shipped in separate box.
Do not use flexible duct. Round duct instead of rectangular duct recommended, especially when elbows are required.
When multiple elbows are necessary, ensure a minimum of 24" of straight duct between any two elbows.
Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold.
For most efficient airflow exhaust, use a straight run or as few elbows as possible.
Cold weather installations should have additional backdraft damper installed.
Installing a Downdraft Vent in combination with any gas cooking surface will affect optimum burner efficiency.
Downdraft Vents can NOT be used in combination with any cooktop backsplash.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
USA
250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287)
CANADA
SIC_DDV_PREP 05/08 © 2008 Electrolux Home Products, Inc. Printed in the U.S.A.
5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352
electroluxicon.ca
electroluxicon.com
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Page 4
30" & 36" Gas Slide-In Cooktop Power Cord Relocation Instructions
1 2 3
4 65
7 8 9
To install an Electrolux ICON™ Gas Slide-In Cooktop in combination with an Electrolux ICON™ Downdraft Vent, cooktop power cord MUST be relocated to underside of unit.
Gas Slide-In Cooktops requiring this procedure are: E30GC74GPS, E36GC75DSS, E36GC75ESS, E36GC75GSS, E36GC76EPS and E36GC76GPS.
Please have qualified electrician perform following rewiring procedure in accordance with local and national electric codes.
Tools & Materials:
Phillips-Head Screwdriver, Hammer, Awl or Punch, Drill with 3/4" drill bit, 2-Plastic Inserts (73209-2470), Silicone Caulk and Aluminum Tape.
Procedure:
1. Remove electrical access panel from rear
of cooktop.
2. Disconnect power cord and ground wires,
then remove from cooktop.
3. Locate area for new hole to be drilled, 1/2"
in from back edge on underside of cooktop, then mark hole location using an awl or punch.
4. Use 3/4" drill bit to drill new hole completely
through.
5. Route power cord wires through hole.
6. Place plastic inserts in upper and lower
drilled holes to protect cord.
7. Knot power cord to secure into place.
8. Reconnect power cord and ground wires.
9. Fill remaining hole surrounding power cord
with silicone caulk.
10. Cover both sides of original hole with two
layers of aluminum tape.
11. Screw electrical access panel back in place.
10
11
USA
250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287)
CANADA
GC_PCRELO 03/08 © 2008 Electrolux Home Products, Inc. Printed in the U.S.A.
5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352
electroluxicon.ca
electroluxicon.com
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Loading...