Burner configuration includes two versatile
Min-2-Max
from 18,000 to 450 BTUs. Thanks to the double
ring configuration, you can simmer sauces or
bring water to a boil. You decide the level of heat
output by a simple turn of the knob.
Four Sealed Burners
Versatile sealed burner configuration provides
the utmost in cooking flexibility. Includes: two
18,000-450 BTU Min-2-Max
14,000 BTU Power Burner
Precision Burner
™
sealed burners delivering anywhere
™
burners, one
™
™
.
and one 5,000 BTU
Designed for the well-lived home.
30" GAS SLIDE-IN COOKTOP
Configuration
FEATURES
Formed Stainless Steel Platform
Large Professional Skirted Knobs with Bezel
Min-2-Max™Dual-Ring Sealed Burner (BTU)
Sealed Power Burner™(BTU)
Sealed Precision Burner™(BTU)
Linear Flow Burner Valves
Electronic Ignition with Auto Re-Ignition
Continuous Grates
Depth
Gas Inlet/ Power Supply Location
Voltage Rating
Connected Load (kW Rating) @120 Volts
Electrical Cable
Approved for Single Oven Combination Installation**
Approved for Downdraft Vent Combination Installation**
Product Weight
Shipping Weight (Approx.)
* When replacing an existing cooktop with countertop cutout deeper than 7-1/4"
and less than 8-1/2", order free Depth Adjustment Filler Kit.
‡ For use on adequately wired 120V, dedicated circuit having 2-wire service with
a separate ground wire. Appliance must be grounded for safe operation.
** Not approved to be used over any Electrolux ICON™Single Wall Oven. Approved to be
used in combination with an Electrolux ICON™Downdraft Vent. (Proper combination
installation will require cooktop power cord to be relocated.)
NOTE: Always consult local and/ or national electric and gas codes. Refer to Product
Installation Guide for detailed installation instructions on the web at electroluxicon.com.
Included
Included
Included
Optional
Optional
Optional
7-3/4"
29-7/8"
25"
Right Rear
120V/ 60Hz /15A
0.001
Included
No
Yes
95 Lbs.
100 Lbs.
Sealed Cooktop Spill-Basin
Cleanup is convenient with a black porcelaincoated area beneath the burners to catch spills.
Professional-Style Controls
Large professional-feel, front-mounted control
knobs provide easy and accurate settings. 270
degree rotation offers superior flame control.
Optional black knobs available.
electroluxicon.com
Page 2
Gas Slide-In Cooktop
7
1
/4"
3
/8"
E30GC74GPS
13"
max.
cabinet
depth
Optional 9" stainless
steel backsplash
(attaches to wall)
1" min. recommended distance between
rear edge of cutout and nearest combustible
surface above countertop
2"
Side inset 5/8"
29 7/8"
29 15/16"**
30" min.
25"
71/2"
73/4"
30" min. for
unprotected cabinet
24" min. with
protected bottom
18"
min.
**Applies only in case
of countertop backwall
7" min. to nearest
combustible wall
(either side of unit)
surface
221/8"
3"
2" dia.
opening to route
power cable
21/2"
2"
Support
platform
1
29
/8"
29 3/16"*
29
15
/16"*
*Both cutout dimensions are
24"
1" countertop
11/8"
max.
4" x 4" opening to
route gas supply
is recommended to undercut finished dimension
critical to proper cooktop installation.
Due to variations in countertop materials it
15
/16" and adjust upon installation of cooktop.
29
overhang
30" Gas Slide-In Cooktop Specifications
•
Product Weight – 95 Lbs.
•
Voltage Rating –120V / 60Hz/15 Amp
•
Connected Load (kW Rating) @120 Volts = 0.001kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
•
Amps @120 Volts = 0.008 Amps
•
Always consult local and/or national electric and gas codes.
•
Cooktop ships with 3/4" factory regulator.
•
Lp conversion kit supplied.
•
Plan installation to have electrical connection, gas shutoff valve, and
pressure regulator accessible from front of cabinet. Locate 120V
grounded outlet in a 4"W x 5"H area on rear wall, 16" above floor,
aligned center with cooktop.
•
Cabinet and/or countertop must completely enclose recessed portion
of cooktop. Respect cutout dimensions and clearances and ensure
that all contact surfaces are solid and level.
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
•
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No.28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
•
USA
250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287)
5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352
•
electroluxicon.ca
•
Allow 1" minimum clearance between rear edge of cooktop and nearest
combustible surface above countertop. If required clearance can not be
maintained, then optional stainless steel backsplash or noncombustible
backsplash material must be used – otherwise installation will require
custom cabinet and countertop dimensions.
•
Allow 7" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
•
It is recommended that drawers not be used beneath cooktop.
•
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 7" beyond bottom
of cabinets.
•
Gas Slide-In Cooktop model E30GC74GPS is NOT approved to be used
over any Electrolux ICON™ Single Wall Oven.
•
Gas Slide-In Cooktop model E30GC74GPS (without optional backsplash)
is approved to be used in combination with an Electrolux ICON
™
Downdraft Vent. (Refer to Slide-In Cooktop/Downdraft Vent CountertopPreparation Specifications page and on web.) Proper combination
installation will require cooktop power cord to be relocated to underside
of unit. (For details, refer to 30" & 36" Gas Slide-In Cooktop Power Cord
Relocation Instructions on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
•
When replacing an existing cooktop with countertop cutout deeper
than 7-1/4" and less than 8-1/2", order free Depth Adjustment Filler Kit –
(903051-9100).
•
9" Stainless Steel Backsplash – (903048-9100).
•
Black Knobs Kit – (903049-9110).
•
electroluxicon.com
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
For detailed Slide-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.
•
Position cooktop/vent cutout so all required minimum clearances
are met.
•
Minimum flat countertop area must meet or exceed combined overall
width and depth as shown.
•
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
•
Always consult local and/or national electric codes. Check local building
codes for installation requirements, as they may vary per locale.
•
Proper combination installation will require 30" & 36" Gas Slide-In
Cooktop power cord to be relocated to underside of unit. (For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions on web.)
Downdraft Vent Specifications
•
For detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.
•
Voltage Rating –120V / 60Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
•
Amps @120 Volts = 8.0 Amps
•
Vent unit outside of building only.
•
Vent must be installed in vertical orientation only.
•
1,600 CFM remote exhaust blower (part number 5304444802) included
with vent – shipped in separate box.
•
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
•
When multiple elbows are necessary, ensure a minimum of 24" of straight
duct between any two elbows.
•
Thermal breaks such as short section of nonmetallic duct, should be
used in areas of extreme cold.
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
•
Cold weather installations should have additional backdraft damper
installed.
•
Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.
•
Downdraft Vents can NOT be used in combination with any cooktop
backsplash.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
•
USA
250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287)
5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352
•
electroluxicon.ca
•
electroluxicon.com
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Page 4
30" & 36" Gas Slide-In Cooktop
Power Cord Relocation Instructions
123
465
789
To install an Electrolux ICON™ Gas Slide-In Cooktop in combination with an
Electrolux ICON™ Downdraft Vent, cooktop power cord MUST be relocated to underside of unit.
Gas Slide-In Cooktops requiring this procedure are: E30GC74GPS, E36GC75DSS, E36GC75ESS,
E36GC75GSS, E36GC76EPS and E36GC76GPS.
Please have qualified electrician perform following rewiring procedure in accordance with local and
national electric codes.
Tools & Materials:
Phillips-Head Screwdriver, Hammer, Awl or Punch, Drill with 3/4" drill bit,
2-Plastic Inserts (73209-2470), Silicone Caulk and Aluminum Tape.
Procedure:
1. Remove electrical access panel from rear
of cooktop.
2. Disconnect power cord and ground wires,
then remove from cooktop.
3. Locate area for new hole to be drilled, 1/2"
in from back edge on underside of cooktop,
then mark hole location using an awl or punch.
4. Use 3/4" drill bit to drill new hole completely
through.
5. Route power cord wires through hole.
6. Place plastic inserts in upper and lower
drilled holes to protect cord.
7. Knot power cord to secure into place.
8. Reconnect power cord and ground wires.
9. Fill remaining hole surrounding power cord
with silicone caulk.
10. Cover both sides of original hole with two
layers of aluminum tape.
11. Screw electrical access panel back in place.
10
11
•
USA
250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287)