PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS
Type A with Run/Start
Capacitor
Operating Time 8 to 15% 20 to 40%
Temperature 40°F to 65°F 40°F to 65°F
Low Side Pressure (cut-in)
Low Side Pressure (cut-out)
High Side Pressure
(last 1/3 cycle)
Wattage (last 1/3 cycle) 55 to 80 55 to 80
Amps (running) .45 to .85 .45 to .85
Base voltage 115 vac (127 vac max)
Watts RPM Amps
4.1 1280 0.06
1.08 2550 0.09
AT MID-POINT CONTROL SETTINGS
65° (18°C) Ambient 90° (32°C) Ambient
25 to 50 psig
172 to 345 kPa
0 to 10 psig
0 to 69 kPa
95 to 125 psig
655 to 862 kPa
CONDENSER FAN MOTOR
EVAPORATOR FAN MOTOR
25 to 50 psig
172 to 345 kPa
0 to 10 psig
0 to 69 kPa
130 to 175 psig
896 to 1207 kPa
SERVICE DATA SHEET
41013619
WINE COOLER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist
qualified repair personnel only. Untrained persons should not
attempt to make repairs due to the possibility of electrical
shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing,
they must be returned to their original position and properly
secured.
CAUTION
All electrical parts and wiring must be shielded from torch
ame. DO NOT allow torch to touch insulation; it will char
at 200°F and ash ignite (burn) at 500°F. Excessive heat
will distort the plastic liner.
NOTE
Your Electrolux wine cooler has been designed for either
free-standing or built-in installation. When built-in, your
wine cooler does not require additional air space for top,
sides or rear. In either case, the front grille must NOT be
obstructed.
To ease unit installation and removal, it is recommended
that the cabinet rough opening dimensions be increased by
at least ¼ inch over the dimensions given for the unit.
All units require zero clearance when installed flush with a
cabinet or wall. Electrolux stainless steel models require a
minimum 215⁄32 inch handle clearance when installed
against a wall or cabinet that extends beyond the front
edge of the unit.
To p
View
IMPORTANT: PLEASE RETURN THIS SHEET
TO IT'S ORIGINAL LOCATION.
Unit Dimensions
Width Height Depth
237⁄8 inch 333⁄4 to 343⁄4 inch 2611⁄32 inch
211⁄16"
237⁄8"
Front
View
311⁄32"
333⁄4"
Adjustable to
343⁄4"
4613⁄32"
215⁄32"
2611⁄32"
2323⁄32"
21½"
Side
View
COMPRESSOR
SERVICE
CORD
GROUND
RUN
CAPACITOR
GREEN
BLACK (SMOOTH)
BLACK (RIBBED)
WHITE
RED
LIGHTS
BLU
RED
WHITE WHITE
WHITE
RED
BLU
RED
BLU
B
CONDENSER
FAN
RED
BLUE
RED
WHITE
FAN LOW
BLACK BLACK
RED RED
SWITCHES
(RD ONLY)
EVAPORATOR
DEFROST SENSOR
WHITE WHITE
SWITCH
LOW
BLUE WIRE PIN 2
WHITE WIRE PIN 3
BLACK
BLACK
DOOR
SENSOR
SWITCH
UP
WHITE
WHITE
WHITE
WHITE
CABINET
TEMP SENSOR LOW
WHITE
COMM.
BLUE
RING SPRING
PROGRAMMING/
DATA ACQUISITION PORT
(MODELS WITH RS485 BOARDS ONLY)
TIP SPRING
USER