PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
CONTROL SETTING (2500++ V4 CONTROLS)
Variable Speed Compressor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 32 to 40% 100%
Freezer Temperature
Refrigerator Temperature
Low Side Pressure
(cut-in)
Low Side Pressure
(cut-out)
High Side Pressure
-6° to 6°F
-21° to -14°C
33° to 46°F
0.5° to 8°C
5 to 12 psig
34 to 83 kPa
-2 to 2 psig
-14 to 14 kPa
85 to 95 psig
586 to 655 kPa
-6° to 6°F
-21° to -14°C
33° to 46°F
0.5° to 8°C
N/A
-2 to 2 psig
-14 to 14 kPa
120 to 135 psig
827 to 931 kPa
Wattage 40 to 55 60 to 70
Amps (running) 0.5 to 1.1 0.7 to 0.9
Base Voltage 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
23’ SD, 28’ SD, 23’ CD
Thermostat Heater
Cut-in Cut-out Watts Ohms
25°F
(-4°C)
47°F
(8°C)
500 26
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM Amps
3.1
(Energy Star, some models)
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F (9°C), Closes at 15°F (-9°C)
Heater Voltage 85 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Green / Yellow Ground
2 Yellow / Blue Water Valve
3 Black / Orange Line
4 Light Blue Neutral
SERVICE DATA SHEET - 242173700
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualied repair personnel
only. Untrained persons should not attempt to make repairs due to the possibility
of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be
returned to their original position and properly secured.
CAUTION
All electrical parts and wiring must be shielded from torch ame. DO
NOT allow torch to touch insulation; it will char at 200°F and ash
ignite (burn) at 500°F. Excessive heat will distort the plastic liner.
NOTE
This product comes equipped with an Adaptive Defrost Control (ADC). To activate
manual defrost, simultaneously press and hold the Fresh Food up (+) and Fresh
Food down (-) keys for 5 seconds. A “d” in the freezer temperature window
and “F” in the refrigerator temperature window will display when the heater
is activated. To deactivate manual defrost, simultaneously press and hold the
Fresh Food up (+) and Fresh Food down (-) keys for 5 seconds. A “d” and “F”
will be displayed until the defrost cycle is complete.
IMPORTANT
PLEASE RETURN THIS SHEET TO ITS ORIGINAL
LOCATION.
ICE MAKER INFORMATION
Test Cycling: Remove cover by inserting screwdriver in notch at bottom
and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker
should function to complete the cycle.
Water Fill Volume: The water ll adjust-
ment screw will change the ll time. One full
turn is equal to 20cc (.68 oz.). The correct
ll is 102 to 130cc (3.4 to 4.3 oz.). When a
water valve is replaced, the ll volume must
be checked.
NO
NC
NEUTRAL
YEL
RED
ICE MAKER
P-2
P-4
YEL / BLUE
WATER VALVE
LT. BLUE
LINE
BLK / ORG
P-3
GRN / YEL
P-1
BLK
ICE MAKER
GRN / YEL
MOLD
THERMAL
CUT-OUT
BRN
BLK
MOUNTING
PLATE
POWER
MOTOR
RED
MOLD HEATER
165 WATTS
ICE MAKER
HOLD
SWITCH
C
BLK
ICE MAKER
NO
NC
WATER FILL
RED
YEL
THERMOSTAT
BLU
NO
NC
C
SWITCH
C
SHUTOFF
SWITCH
LT. BLUE