Thank you for purchasing this Electrocompaniet ECT 3 remote control.
The ECT 3 can be used for most remote controlled Electrocompaniet
products, either infrared (IR) or 2 way radio communication (RF)
products from 1976 until present day.
1.2 Package contents
- ECT 3 remote control
- Manual
- USB cable
- Inspection card
1.3 Important References
In this manual we have used some simple rules to make it easier to
understand the meaning of the text.
SELECT:
We use capital letters for all references to buttons on the ECT 3
Balance:
Italic lower-case letters is used to describe text on the ECT 3 screen.
Balance:
Bold Italic lower-case letters is used as reference to another chapter in
this manual.
3
General use
1.4 Before you start using the system
Step 1
We recommend to charge the battery before using the ECT 3 for the
first time. The procedure is described in the chapter: "charging the
batteries"(page 6) However, you don't need a full charge to use the ECT 3
Step 2
When you are finished with step 1 you are ready for the first setup of
your ECT 3.
When starting up the remote control for the first time, the main ECT 3
page will be the only accessible page / unit.
The picture underneath shows the meaning of the different symbols:
Connection indicator
Beep ON or OFF
Volume priority
presents the unit for
main volume
Software version
EC 4.8 V 2.05
Battery level
4
1.5 ECT 3 Illustration
General use
MENU
activate menus and
submenus for the
selected unit
EXIT
exit any kind of
menu or submeny
FUNCTION
activate extended
remote features on
the selected device
VOLUME +
Main volume
control
VOLUME -
Main volume
control
OK
Confirm your
selection.
WHEEL
SELECTOR
Wheel selector and 4
directional navigator.
Wheel used to select
input source, change
volume and to navigate in menus.
DEVICE
Select the device to
control
5
General use
1.6 Charging the Batteries
The remote controller can be charged through a standard USB cable,
included in the package with the ECT 3. Please connect this cable on the
rear side of EC4.8 / EC4.9 or use any USB port (PC, usb charger, etc).
If the EC4.8 / EC4.9 is turned off, please turn on the system to start the
charging. You can supervise the charging process by inspecting the
main screen on the ECT 3.
ECT 3
Buzzer On Batt.
Vol: EC4.8 49%
V 2.02
Battery Level
Batt.
49%
Rear view of EC4.8
6
General use
1.7 Using the ECT 3
The wheel is used on 2 different ways:
You can either scroll through the menu and use OK button to confirm
or you can activate or change values inside the menu by pressing the
arrow left/right or up/down
Wheel mode.
When icon at the
display
ECT 3 V 2.05
Buzzer o Batt
Vol: ECI 4/5 77%
Setup ECT 3
Volume Priority
Beep on/off
Power Mode
Connect
Acceleration Sensor
Deep Sleep
Joystick mode.
When icon at
:
the display
Press MENU button and ECT 3 menu
page will appear.
1. Create a list of devices you want to
manage
By using the wheel you can scroll
through a list of Electrocompaniet products. Choose all products you like to
control by the ECT3 and activate or
deactivate them by pressing OK.
An “x” will indicate the products
chosen.
Press EXIT for the previous page.
2.Volume priority: All activated products
with volume control are listed here (preamp, integrated amps, D/A converters).
If you have selected more then one product with volume control in the product
list you are able to put one of them
on volume priority. This means the
volume + and – buttons on your
remote control will always control
this unit regardless of the chosen
page or menu. In most cases you
will only find one product in this list
and this unit will automatically have
the volume priority.
:
7
1.7 Using the ECT 3
3.Beep ON/OFF
Activate or deactivate the inbuilt buzzer by pressing on arrow left or
right on the control wheel. Press EXIT for previous page.
4.Power Mode – press arrow up or down for changing between:
Power down: adjust the release time for automatic standby for the
ECT 3 between 3 and 30 minutes
Press arrow left and right for changing the value.
Display Off – adjust the release time for automatic display off
between 20 and 180 seconds. Press arrow left and right for changing the value.
5. Connect
Press OK for activates a connection between the ECT3 and a RF controlled
Electrocompaniet unit. See chapter 1.8 for detailed description.
6. Acceleration sensor
Change the sensitivity of the touch control wheel by pressing arrow left or right.
7. Deep sleep
Press OK for activating deep sleep.
Attention: The reset button or a USB connection must be used for waking
up the ECT3 from deep sleep.This function is meant for transportation and
air shipments only.
8.Product Dimming
Press arrow left and right for changing the
display light intensity of supported units, RF
units only.
ATT: This feature will not change the
display light on your ECT3.
Press EXIT or OK for the previous page.
STANDBY mode
Press EXIT for more then 2 seconds for activating STANBY for all supported RF-controlled Electrocompaniet products.
8
General use
1.8 Connecting the remote control
If you are only using units with infrared links it is not necessary to connect the ECT
3 to the specific unit, all you have to do is to select them in the Product List.
For units with a RF connection you have to establish a link between the devices and
the ECT 3. The following products from Electrocompaniet has a RF connection: EC
4.8, EC 4.9 and EMP 1 M and S.
The remote controller uses
a two way communication
system. To know what product to control, the remote
controller has to learn a
unique serial number stored
in each product. With
this number the ECT 3
knows which units to
control.
Press and hold
button 1 while holding this button
turn on the device , until "searching
for remote" will display on unit.
Press MENU button
Go to - SETUP ECT 3 --> CONNECT
Press OK
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.