Elation Professional TVL2000II User manual

Page 1
TVL2000
TVL2000 General Information
Unpacking: Thank you for purchasing the TVL2000 by Elation Pro-
fessionals®. Every TVL2000 has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the
carton appears to be damaged, carefully inspect your xture for any
damage and be sure all equipment necessary to operate the unit has arrived intact. In the event damage has been found or parts are miss­ing, please contact our toll free customer support number for further instructions. Please do not return this unit to your dealer without con-
tacting customer support rst.
Introduction: The TVL2000 DMX intelligent LED fixture. The TVL2000
has 3 DMX Modes; Two 2 Channel DMX Modes, and a 3 Channel Mode. The fixture two operating modes; manual mode or DMX con­trolled. The TVL2000 can only be run as stand alone unit. This fixture is suitable for theaters, studios, retail stores, and other similar locations.
For best results use fog or special effects smoke to enhance the light projections.
Customer Support: Elation Professionals® provides a toll free cus-
tomer support line, to provide help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any com­ments or suggestions. Service Hours are Monday through Friday 8:00
a.m. to 4:30 p.m. Pacic Standard Time.
Voice: (323) 582-3322
Fax: (323) 832-9142
E-mail: support@elationlighting.com To purchase parts online visit http://parts.elationlighting.com
Rev. 1/13
User Instructions
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 2
Page 2
TVL2000 General Instructions
TVL2000 Safety Precautions
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
TVL2000 Features
• 3 DMX Channel Modes; Two 2 Channel Modes & 3 Channel Mode
• 2 Operating Modes - Manual Mode & DMX Control
• Digital Display for Address and Function Setting
• Power Cord Daisy Chain
TVL2000 Warranty Registration
The TVL2000 carries a 2 year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase and war­ranty. You may also register your product online at www.elationlight­ing.com. All returned service items whether under warranty or not,
must be freight pre-paid and accompany a return authorization (R.A.)
number. If the unit is under warranty you must provide a copy of your proof of purchase invoice. Please contact Elation® customer support
for a R.A. number.
TVL2000 Handling Precautions
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war­ranty. In the unlikely event your unit may require service please contact Elation Professionals®.
During operation the housing may become hot. Avoid touching the unit with bare hands while in use.
Elation Professionals® will not accept any liability for any resulting dam- ages caused by the non-observance of this manual or any unauthor-
ized modication to this unit.
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
• To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt-
age for your unit.
• Do not attempt to operate this unit if the power cord has been
frayed or broken.
• Do not attempt to remove or break off the ground prong from
the electrical cord. This prong is used to reduce the risk of electrical
shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user
serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out-
doors voids all warranties.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep-
tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 15 for cleaning details.
• Heat -This fixture should be situated away from heat sources such
as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. Objects have fallen, or liquid has been spilled into the appliance. B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits a
marked change in performance.
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 4©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 3
Page 3
TVL2000 Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
and PIN 3 (DMX +) of the last fixture.
TVL2000 Set Up
Power Supply: The Elation Professionals® TVL2000 contains an
electronic ballast, which will auto sense the voltage when it is plugged into the power source. With the electronic ballast you do not need to
worry about wall voltage, this unit can be plugged in anywhere. Also
be sure to only use the included I.E.C. power cable supplied with the unit.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix­ture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a sin­gle controller, as long as all xtures and the controller are DMX com­pliant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): The TVL2000 3 DMX channel modes. The DMX address
is set electronically using the controls on the side of the unit. Your unit and your DMX controller require a approved DMX-
512 110 Ohm Data cable for data input and data output. We recommend Accu-Cable DMX cables.
If you are making your own cables, be sure to use
standard 110-120 Ohm shielded cable (This cable
may be purchased at almost all professional sound and lighting stores). Your cables should be made with a male and female XLR connector on either
end of the cable. Also remember that DMX cable
must be daisy chained and cannot be split.
Figure 1
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
Figure 4
XLR Male Socket
1 Ground
DMX512 OUT
3-PIN XLR
2 Cold
3 Hot
1
3
2
XLR Female Socket
2 Cold
DMX +
DMX -
1 Ground
3 Hot
Figure 3
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-)
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 6©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 5
Page 4
TVL2000 Set Up TVL2000 Control Panel
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin XLR
connectors for DATA transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting stan­dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Pin 4 - Do Not Use
Pin 5 - Do Not Use
TVL2000 Installation
The unit should be mounted using a mounting clamp (not provided),
afxing it to the mounting bracket that is provided with the unit. Always ensure that the unit is rmly xed to avoid vibration and slip­ping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable that can hold 12 times the weight of the unit when installing the xture.
The equipment must be installed by a professional, and it must be
installed in a place where it is out of the reach of people’s grasp.
1 Display: Shows the various menus and the selected functions
2 Indicator LED:
DMX On DMX input present
MASTER On Master Mode
SLAVE On Slave Mode
COLOR TEMP. On Max. power consumption of CW/WW
3 Button:
MENU To select the programming functions
DOWN To go backward in the selected functions
UP To go forward in the selected functions
ENTER To confirm the selected functions
4 Color Temperature Adjustment: Adjust the color temperature from 3200k to 6500k, 25K
5 Dimmer Adjust knob: Adjust the intensity of the unit.
6 DMX output: For DMX512 link, use 3/5-pin XLR plug cable to link the next unit.
7 DMX input: For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal
8 Mains output: Connect to supply main power for the next unit.
as a step. When the value is between 4825K and 4875K the green LED indicator will light . It means the power consumption of CW/WW color the maximum.
has
reached
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 7 ©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 8
Page 5
TVL2000 System Menu
TVL2000 System Menu
System Menu.
menu. This next section will detail the functions of each command in
the system menu. Please read the next section thoroughly!
To access the main menu press the MENU button. Tap the UP or DOWN buttons until you reach function you wish to change. When you reach the function you wish to change press the ENTER button. When a function is selected use the UP or DOWN buttons to change the func-
tion settings. Once your changes are made press the ENTER button, and then press and hold the MENU button for at least three seconds to conrm and lock the change into the system memory. If the MENU button is not pressed and held within eight seconds the xture will automatically conrm and lock the change into the system memory. To exit without making any changes press the MENU button.
The TVL2000 comes with an easy to navigate system
ADDR - DMX Address Setting.
1. First set the unit to your desired DMX Channel mode.
2. To set your address, tap either the MENU, UP, or DOWN buttons until “ADDR” is displayed, press ENTER. “1” will now be displayed and ashing.
3. Press the UP or DOWN buttons to nd your desired address. When you have found your desired DMX address press ENTER,
and connect your DMX Controller.
CHND - This will let you switch between the 3 DMX Chan-
nel Modes.
1. Press the MENU button until “CHND” is displayed, press ENTER. Either “MOD 1” (2 Channel Mode), “MOD 2” (2 Channel Mode), or “MOD 3” (3 Channel Mode) will be displayed
2. Press the UP or DOWN buttons to choose your desired DMX mode and press ENTER to conm and exit.
MANU - In this mode you can manually adjust the LED
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 10©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 9
Page 6
TVL2000 System Menu
TVL2000 System Menu
intensity to create your desired color temperature.
1. Press the MENU button until “MANU” is displayed, press ENTER. “LED1”, “LED2” or “DINN” will be displayed. LED 1 is
warm white, LED 2 is cool white, and DIMM is the master dimmer for this mode.
2. Use the UP or DOWN buttons to scroll to the color you would like adjust rst, and press ENTER.
3. Use the UP or DOWN buttons to adjust the intensity of the chosen color, and press ENTER after the adjustment.
4. Continue to make adjustments to the two colors until your desired color is reached. Once your desired color is reached do
not leave this mode.
5. To leave this mode, press the MENU button. Once you leave
this mode, all settings will be reset.
BLND - Blackout or Stand by mode.
1. Press the MENU button until “BLND” is displayed, press ENTER. Either Yes or No will be displayed.
2. To activate Blackout press the UP or DOWN buttons until Yes is displayed, press ENTER to conm and exit. The xture will now be in Blackout mode. To deactivate Blackout mode, select No and press Enter.
3. Press ENTER to conrm.
DISP - This function will reverse the display 180º.
1. Press the MENU button until “DISP” is displayed, press ENTER.
2. Press the UP button to select “DISP” to activate this function, or “DSIP” to deactivate this function.
3. Press ENTER to conrm.
TEST - This function will run a self test program.
1. Tap the MENU button until “TEST” is displayed, press ENTER.
2. The xture will now run a self test program. To stop the self test press either the MENU or ENTER button.
FHRS - With this function you can display the running time
of the unit.
1. Press the MENU button until “FHRS” is displayed, press ENTER.
2. The display shows the running time of the unit. Press MENU to exit.
LED - With this function you can have the LED display
turn off after 20 seconds.
1. Press the MENU button until “LED” is displayed, press ENTER.
2. The display will show either “ON” or “OFF”. Press the UP or DOWN buttons to select “ON” to keep the LED display On at all times, or “OFF” so that the LED display turns off after 20 sec-
onds.
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 11
VER - Use this function to display the Software version of
the unit.
1. Press the MENU button until “VER” is displayed, press ENTER.
2. The display will show the software version.
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 12
Page 7
TVL2000 Universal DMX Control
DMX 512 c onf iguration
TVL2000 DMX Modes
Universal DMX Control: This function allows you to use a Elation®
universal DMX-512 controller to create unique programs tailored to your individual needs.
1. The TVL2000 has three DMX channel modes. To set the chan- nel mode see page 10. See page 14 for the DMX modes & traits.
2. To control your fixture in DMX mode, follow the set-up procedures
on pages 5-7 as well as the set-up specifications that are included with your DMX controller.
3. Use the controller’s faders to control the various DMX fixture traits.
4. This will allow you to create your own programs.
5. Follow the instructions on page 10 to set the DMX address.
6. For longer cable runs (more than a 100 feet) use a terminator on the last fixture.
7. For help operating in DMX mode consult the manual included with your DMX controller.
Manual Mode: This mode allows the user to adjust the color intensity
to create their own desired color temperature.
1. Press the MENU button until MANU” is displayed, and press
ENTER.
2. Follow the instructions on pages 10-11 to operate this mode.
3. You can also use the Color Adjust Knob and Dimmer Knob to
manually create your desired color temperature. Please see the Control Panel on page 8.
Ch1
0%
100%
100%
War m Whi te
0%
Mode 2
255
Coo l White
Ch2
Dimm er
100%
0% 0%
0
0
Mode
Mode 1
Ch1 Ch1Ch1 Ch1Ch1 Ch1Ch1 Ch1
CW CWCW CW
100%
255
Ch2 Ch2
Ch2 Ch2
0%
255
0
WW
100%
0%
Colo r Mi x
255
0
255
100%
000 0
255
Mode 3
WW
100%
0%
0
Ch3
Dimm er
255
0
0
100%
0%
TVL2000 Photometric Chart
TVL2000 Power Cord Daisy Chain
With this feature you can connect the xtures to one another
using the IEC input and output sockets. The quantity that can be
connected is 4 xtures maximum. After 4 xtures you will need to use a new power outlet. They must be the same xtures. DO NOT mix xtures.
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 13 ©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 14
Page 8
TVL2000 Fuse Replacement
TVL2000 Warranty
First unplug the power. Locate and remove the unit’s power cord. Once the cord has been removed located the fuse holder located
inside the power socket. Insert a flat-head screw driver into the power socket and gently pry out the fuse holder. Remove the bad fuse and replace with a new one. The fuse holder has a built-in socket for a spare fuse be sure not to confuse the spare fuse with active fuse.
TVL2000 Cleaning
Fixture Cleaning: Due to fog residue, smoke, and dust cleaning the
internal and external optical lenses and mirror should be carried out
periodically to optimize light output. Cleaning frequency depends on
the environment in which the fixture operates (I.e. smoke, fog residue,
dust, dew). In heavy club use we recommend cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics and mirror with glass cleaner and a soft
cloth every 20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.
TVL2000 Trouble Shooting
2-YEAR LIMITED WARRANTY
A. Elation® Architectural hereby warrants, to the original purchaser, Elation® Professionals® products to be free of manufacturing defects in material and workmanship for a period of two years (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States
of America, including possessions and territories. It is the owner’s responsibility
to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation® Professionals® factory. All shipping charges must be pre-paid. If the requested repairs or ser­vice (including parts replacement) are within the terms of this warranty, Ela­tion® Professionals® will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation® Professionals® shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the
product is modied in any manner which Elation® Professionals® concludes,
after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation® Professionals® factory unless prior written authorization was issued to purchaser by Elation® Profes­sionals®; if the product is damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include mainte­nance, cleaning or periodic check-up. During the period specied above, Ela­tion® Professionals® will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in mate­rial or workmanship. The sole responsibility of Elation® Professionals® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation® Professionals®. All products covered by this warranty were manufactured after January 1, 1990, and bear identifying marks to that effect.
Trouble Shooting: Listed below are a few common problems that you may encounter, with solutions.
No light output from the unit;
1. Be sure the external fuse has not blown. The fuse is located on
the rear panel of the unit.
2. Be sure the fuse holder is completely and properly seated.
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 15
E. Elation® Professionals® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation® Profession­als® in connection with this product, including warranties of merchantability or tness, are limited in duration to the warranty period set forth above. And no war­ranties, whether expressed or implied, including warranties of merchantability or
tness, shall apply to this product after said period has expired. The consumer’s and or Dealer’s sole remedy shall be such repair or replacement as is expressly
provided above; and under no circumstances shall Elation® Professionals® be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.
G. This warranty is the only written warranty applicable to Elation® Profession­als® Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 16
Page 9
TVL2000 Notes TVL2000 Notes
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 17 ©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 18
Page 10
TVL2000 Specifications
Model: TVL2000
Voltage: 100 - 240V~50/60Hz
LEDs: 900 LEDs (450 Cool White &
450 Warm White)
Power Consumption: 76W Fuse: 7A
Power Cord Daisy Chain: 4 Fixtures Max. Dimensions: 14.6”(L) x 13”(W) x 4.3”(H)
371mm x 328mm x 110mm
Weight: 13.6 Lbs. / 6.2 kgs. Colors: Cool White & Warm White
Duty Cycle: None DMX: 3 DMX Channel Modes: 2 Channel
Mode, 2 Channel Mode, & 3 Channel
Mode
Sound Active: Ye s Working Position: Any Safe, Secure Position Warranty: 2 Year (730 days)
Please Note: Specications and improvements in the design
of this unit and this manual are subject to change without any prior written notice.
Auto Sensing Voltage: This xture contains a electronic bal-
last, which will auto sense the voltage when it is plugged into the power source.
©Elation Professionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 19
©Elation Professionals®
A Division of the AmericanDJ® Group of Companies
World Headquarters:
6122 S. Eastern Ave. Los Angeles, CA 90040 USA
Tel: 323-582-3322 Fax: 323-832-9142
Web: www.elationlighting.com E-mail: info@elationlighting.com
American DJ Europe
Junostraat 2
6468 EW Kerkrade
Netherlands
service@americandj.eu / www.americandj.eu
Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99