Elation TVL PANEL User Manual [EN]

Page 1
ELATION
|
|
TVL PANEL DW™
user manual
TVL PANEL DW
user manual
Page 2
©2016 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
www.elationlighting.com
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this manual.
Date
11/21/16 1
Document
Version
Software
Version
CPU-A: 1.1 B1.0
CPU-B: 1.1 B1.0
2 / 3 / 4 / 5 / 6 / 7 Initial release.
DMX
Channel Modes
Notes
2 TVL PANEL DW™ User Manual
Page 3
CONTENTS
General Information
4
Warranty
6
Safety Instructions and Guidelines
7
Fixture Overview
9
Barn Door Installation
10
Fixture Installation
11
Fixture Menu
14
DMX Channel Functions And Values
16
Cleaning and Maintenance
17
Technical Specifications
18
Optional Accessories
21
www.elationlighting.com
3 TVL PANEL DW™ User Manual
Page 4
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable lighting fixtures on the market today! This fixture has been designed to
perform reliably for years when the guidelines in this booklet are followed. Please
read and understand the instructions in this manual carefully and thoroughly
before attempting to operate this unit. These instructions contain important
information regarding safety during use and maintenance.
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
Barn Door
Barn Door Safety Cable
Fixture Safety Cable
powerCON TRUE1 Cable
4 TVL PANEL DW™ User Manual
Page 5
www.elationlighting.com
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of
paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support at 323-582-3322.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
5 TVL PANEL DW™ User Manual
Page 6
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to
be free of manufacturing defects in material and workmanship for a period of two years (730 days),
and Elation Professional® product rechargeable batteries to be free of manufacturing defects in
material and workmanship for a period of six months (180 days), from the original date of purchase.
This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at
the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any accessories are
shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or
damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Elation Professional® concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Elation Professional® factory unless prior written authorization was issued to purchaser by Elation
Professional®; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of Elation Professional® under
this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole
remedy shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
6 TVL PANEL DW™ User Manual
Page 7
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
This fixture is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow all instructions and guidelines
in this manual. The manufacturer of this device is not responsible for injury and/or
damages resulting from the misuse of this fixture due to the disregard of the
information printed in this manual. Only qualified and/or certified personnel should
perform installation of this fixture and only the original rigging parts (omega brackets)
included with this fixture should be used for installation. Any modifications to the
fixture and/or the mounting hardware included will void the original manufactures
warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
7 TVL PANEL DW™ User Manual
Page 8
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped and/or
damaged. If the power cord is damaged, replace it immediately with a new one
of similar power rating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and
never blocked. Allow approx. 6” (15cm) between fixture and other devices or a
wall for proper cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug
end, never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
Consistent operational breaks will ensure the fixture will function properly for
many years to come.
Use the original packaging and materials to transport the fixture in for service.
LED LIFE
The average LED Life (hours) may vary depending on several factors including
but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns
(On-Off Cycling), Control and Dimming.
8 TVL PANEL DW™ User Manual
Page 9
FIXTURE OVERVIEW
www.elationlighting.com
1. etherCON (RJ45) IN
2. 5pin DMX IN/OUT
3. BATTERY Connection - NOT SUPPORTED AT THIS TIME
4. FUSE (T5A)
5. powerCON TRUE1 IN
6. DIMMER Dial (manual control)
7. COLOR TEMPERATURE DIAL (manual control)
8. MENU, UP, DOWN, ENTER Buttons
9. LCD Menu Function Display
9 TVL PANEL DW™ User Manual
Page 10
www.elationlighting.com
BARN DOOR INSTALLATION
1. Remove barn door from packaging.
2. Open barn door fully and position in front of the fixture.
3. Align each of the (4) moutning screws by pushing them into place.
4. Secure each screw by hand first turning clockwise.
5. Tighten each screw with a screwdriver. DO NOT OVER TIGHTEN SCREWS!
MAKE SURE BARN DOOR IS COMPLETELY SECURED TO FIXTURE BEFORE INSTALLING!
ATTACH INCLUDED BARN DOOR SAFETY CABLE TO FIXTURE BEFORE INSTALLING!
10 TVL PANEL DW™ User Manual
Page 11
Keep fixture at least 5.0 ft (1.5m) away from any
A qualified electrician should be used for all
FIXTURE INSTALLATION
www.elationlighting.com
FLAMMABLE MATERIAL WARNING
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Maximum ambient operating temperature for this fixture is 104°F. (40°C)
Do not use the fixture under or above this temperature.
 Maximum temperature of the external surface 185°F (85°C).
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
11 TVL PANEL DW™ User Manual
Page 12
www.elationlighting.com
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the device. If you lack these qualifications,
do not attempt the installation yourself. Improper installation can result in bodily
injury. Fixture is fully operational in the specific mounting positions as illustrated
below.
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE
TO THE BARN DOOR AND TO THE
FIXTURE WHENEVER INSTALLING THIS
IN A SUSPENDED ENVIRONMENT TO
ENSURE THE BARN DOOR AND/OR
THE FIXTURE WILL NOT DROP IF
THERE IS A HARDWARE FAILURE.
12 TVL PANEL DW™ User Manual
Page 13
CLAMP MOUNTING
The fixture includes an adjustable mounting yoke that attaches to both sides of the
fixture. When mounting this fixture to truss be sure to secure an appropriately rated
clamp to the mounting yoke using a M10 screw fitted through the center hole of the
mounting yoke. Be sure to attach a Safety Cable to the fixture using the safety cable
rigging point on the back of the fixture as illustrated below.
www.elationlighting.com
SECURING
Regardless of the rigging option you choose for your fixture, always be sure to secure
your fixture with a Safety Cable. The fixture provides a built-in rigging point for a
Safety Cable on the back of the fixture as illustrated below. Be sure to only use the
designated rigging point for the safety cable.
13 TVL PANEL DW™ User Manual
Page 14
www.elationlighting.com
FIXTURE MENU
ON-BOARD SYSTEM MENU
The fixture comes with an easy to navigate system menu. The next section will detail
the functions of each command in the system menu.
LCD MENU CONTROL PANEL
The control panel (see image below) located on back of the fixture allows you to
access the main menu and make all necessary adjustments to the fixture. During
normal operation, pressing MENU button once will access the fixture’s main menu.
Once in the main menu you can navigate through the different functions and
access the sub-menus with the UP and DOWN buttons. Once you reach a field that
requires adjusting, press the ENTER button to activate that field and use the UP and
DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm
your setting. You may exit the main menu at any time without making any
adjustments by pressing and holding the MENU button for 3 seconds.
The MENU display will lock when NO buttons are pressed for 30 seconds. When the
display locks, none of the control panel buttons will respond. To unlock the display,
press and hold the MENU button 5 seconds to access the menu options once again
The DIMMER and COLOR TEMPERATURE control dials are disabled by default.
To enable, press and hold the ENTER button down for 3 seconds.
14 TVL PANEL DW™ User Manual
Page 15
ELATION© TVL PANEL DW™
Supports Software Versions: CPU-A: V 1.1 | B: 1.1
Features subject to change without any prior written notice.
Factory
www.elationlighting.com
S Y S T E M M E N U
MAIN MENU
DMX Setting
Slave Mode
DMX Last
State
Dimmer Curve
White
Balance
Display Setting
Manual
Control
Fixture
Information
SUB MENU OPTIONS / VALUES
DMX Address 001 - 512 Set DMX Address Setting
Ethernet IP Setup
Art-Net Setup
Art-Net Port Setup
Channel Mode
Master, Slave Set Slave Mode
Master Slave, Blackout, Last Start
Standard, Stage, TV, Architec, Theatre Set Dimming Curve Mode
Contrast Ratio 15 (0 - 30) Adjust LCD Control Display Contrast Level
Backlight Auto Off No, Yes Set LCD Display Backlight Function
Invert Display No, Yes Flip LCD Control Display 180°
Fixture Time 0 (hours)
Firmware Version
2 Channel, 3 Channel, 4 Channel, 5 Channel, 6 Channel, 7 Channel
Warm White 50-100
Cool White 50-100
Warm White 0 - 255
Cool White 0 - 255
CPU-A V 1.1 B 1.0
CPU-B V 1.1 B 1.0
(Default Settings in BOLD)
IP Address | 000.000.000.000 Set Fixture IP Address
Subnet Mask | 000.000.000.000 Set Fixture Subnet Mask Address
Net | 0-255
Set Art-NET port Settings Subnet | 0-15
Universe | 0-15
Select DMX Channel Mode
Define How Fixture Reacts When NO DMX Signal Is Present
Adjust White Balance Setting
Control DMX Values Manually
Fixture Information
DESCRIPTION
Setting
No, Yes Reset to factory default settings
15 TVL PANEL DW™ User Manual
Page 16
ELATION© TVL PANEL DW™
DMX Channel Values / Functions (7 Total DMX Channels)
Supports Software Versions ≥: CPU-A: v1.1 B: v1.0 | CPU-B v1.1 B: v1.0
0-255
Cool White (0=Black - 255=100%)
0-255
Warm White (0=Black - 255=100%)
1-255
www.elationlighting.com
DMX CHANNEL FUNCTIONS AND VALUES
Features subject to change without any prior written notice.
MODE / CHANNEL
2 3 4 5 6 7
1 1 1 1
VALUE FUNCTION
WARM WHITE LEDS
2 2 2 2
1 1 3
3 4
2 3 2 3 4 5
3 4 5 6
4 5 6 7
0
0-31 LEDs OFF
32-63 LEDs ON
64-95 Strobe Effect SLOW to FAST
96-127 LEDs ON
128-159 Pulse Effect SLOW to FAST
160-191 LEDs ON
192-223 Random Strobe SLOW to FAST
224-255 LED ON
0-255 Intensity 0 to 100%
0-255 Dimmer Intensity FINE Adjustment
0-20 STANDARD
21-40 STAGE
41-60 TV
61-80 ARCHITECTURAL
81-100 THRATRE
101-255 DEFAULT to UNIT CURVE SETTING
COOL WHITE LEDS
COLOR TEMPERATURE - LINEAR VARIABLE WHITE
OFF
3,200K - 5,600K (0=3,200K - 255=5,600K)
SHUTTER / STROBE
MASTER DIMMER INTENSITY
MASTER DIMMER INTENSITY FINE
DIMMER CURVES
16 TVL PANEL DW™ User Manual
Page 17
www.elationlighting.com
CLEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed check by an approved electrical engineer every three months, to
make sure the circuit contacts are in good condition and prevent overheating.
Ensure all screws and fasteners are securely tightened at all times. Lose
screws may fall out during normal operation resulting in damage or injury as
larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
17 TVL PANEL DW™ User Manual
Page 18
www.elationlighting.com
TECHNICAL SPECIFICATIONS
SOURCE 480 Cool White + 480 Warm White LEDs
20,000 Hour Average Lamp Life*
*May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
EFFECTS
Selectable 16-Bit Dimming Curves and Electronic Strobe Linear Variable White Color Temp Presets (3,200K - 5,600K)
COLOR Cool White / Warm White
CONTROL / CONNECTIONS
(6) DMX Channel Modes (7 Total Channels) 4 Button Control Panel 2 Rotary Control Dials (Dimmer and Color Temperature) 180° Reversible LCD Menu Display 5pin DMX In/Out RJ45 etherCON In (Art-NET) powerCON TRUE1In
SIZE / WEIGHT
Length: 26.3 (668mm) Width: 5.0” (127.5mm) Vertical Height: 19.3” (491.4mm) Weight: 22.0 lbs. (10.0 kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz 199W Max Power Consumption Max Ambient Temperature 104°F (40°C)
APPROVALS / RATINGS
CE | RoHs | IP20
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
18 TVL PANEL DW™ User Manual
Page 19
PHOTOMETRIC DATA
2 m
6.6 ft
3 m
9.8 ft
4 m
13.1 ft
5 m
16.4 ft
COOL
WHITE
www.elationlighting.com
130° Beam
Diameter
8.8 28.9
lux fc
1,650 153
13.20 43.3
lux fc
700 65
17.6 57.7
lux fc
412 38
22 72.2
lux fc
240 22
19 TVL PANEL DW™ User Manual
Page 20
DIMENSIONAL DRAWINGS
www.elationlighting.com
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
20 TVL PANEL DW™ User Manual
Page 21
www.elationlighting.com
OPTIONAL ACCESSORIES
ORDER CODE ITEM
NARROW CLAMP Heavy Duty Wrap Around Clamp
SCABLE60 24” (610mm) 60 lbs. (27 kg) Rated Safety Cable
AC5PDMX5PRO 5 ft. (1.5m) 5pin PRO DMX Cable
CAT005 5' (1.5m) CAT6 etherCON Cable
Additional Cable Lengths Available
21 TVL PANEL DW™ User Manual
Page 22
Loading...