TVL3000WW/TVL3000CW
TVL3000WW/TVL3000CW General Information
Unpacking: Thank you for purchasing the TVL3000WW or
TVL3000CW by Elation Professionals®. Every TVL3000WW &
TVL3000CW has been thoroughly tested and has been shipped in
perfect operating condition. Carefully check the shipping carton for
damage that may have occurred during shipping. If the carton appears
to be damaged, carefully inspect your xture for any damage and be
sure all equipment necessary to operate the unit has arrived intact. In
the event damage has been found or parts are missing, please contact
our toll free customer support number for further instructions. Please
do not return this unit to your dealer without contacting customer sup-
port rst.
Introduction: The TVL3000WW & TVL3000CW are DMX intelligent
LED fixture’s. The TVL3000WW & TVL3000CW have 1 DMX channel,
which is a master dimmer. This fixture’s have two operating modes;
manual mode or DMX controlled. The TVL3000WW & TVL3000CW can
only be run as stand alone unit. The light projections can be enhanced
using fog or special effects smoke.
Customer Support: Elation Professionals® provides a toll free cus-
tomer support line, to provide help and to answer any question should
you encounter problems during your set up or initial operation. You
may also visit us on the web at www.elationlighting.com for any comments or suggestions. Service Hours are Monday through Friday 9:00
a.m. to 5:00 p.m. Pacic Standard Time.
Voice: (323) 582-3322
Fax: (323) 832-9142
E-mail: support@elationlighting.com
To purchase parts online visit http://parts.elationlighting.com
7/11
User Instructions
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
©Elation Professionals® - www.elationlighting.com - TVL3000WW/TVL3000CW Instruction Manual Page 2
TVL3000WW/TVL3000CW General Instructions
TVL3000WW/TVL3000CW Safety Precautions
To optimize the performance of this product, please read these
operating instructions carefully to familiarize yourself with the basic
operations of this unit. These instructions contain important safety
information regarding the use and maintenance of this unit. Please
keep this manual with the unit, for future reference.
TVL3000WW/TVL3000CW Features
• 1 DMX Channel: Dimmer
• 2 Operating Modes - Manual Mode & DMX Control
• Digital Display for Address and Function Setting
• TVL3000WW - Warm White Temperature: 2700~3300K
• TVL3000CW - Cool White Temperature: 5000~6000K
• 4 Beam Angles: 10˚/25˚/40˚/60˚
TVL3000WW/TVL3000CW Warranty Registration
The TVL3000WW & TVL3000CW carry a 2 year (730 days) limited
warranty. Please fill out the enclosed warranty card to validate your
purchase and warranty. You may also register your product online at
www.elationlighting.com. All returned service items whether under
warranty or not, must be freight pre-paid and accompany a return
authorization (R.A.) number. If the unit is under warranty you must
provide a copy of your proof of purchase invoice. Please contact
Elation® customer support for a R.A. number.
TVL3000WW/TVL3000CW Handling Precautions
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact
Elation Professionals®.
During operation the housing may become hot. Avoid touching the
unit with bare hands while in use.
Elation Professionals® will not accept any liability for any resulting dam-
ages caused by the non-observance of this manual or any unauthor-
ized modication to this unit.
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
• To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Do not attempt to operate this unit if the power cord has been
frayed or broken.
• Do not attempt to remove or break o the ground prong from
the electrical cord. This prong is used to reduce the risk of electrical
shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user
serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out-
doors voids all warranties.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to cords at plugs, convenience recep-
tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by
the manufacturer. See page 14 for cleaning details.
• Heat -This fixture should be situated away from heat sources such
as radiators, heat registers, stoves, or other appliances (including
amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. Objects have fallen, or liquid has been spilled into the appliance.
B. The appliance has been exposed to rain or water.
C. The appliance does not appear to operate normally or exhibits a
marked change in performance.
©Elation Professionals® - www.elationlighting.com - TVL3000WW/TVL3000CW Instruction Manual Page 4©Elation Professionals® - www.elationlighting.com - TVL3000WW/TVL3000CW Instruction Manual Page 3
TVL3000WW/TVL3000CW Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
and PIN 3 (DMX +) of the last fixture.
TVL3000WW/TVL3000CW Set Up
Power Supply: The Elation Professionals® TVL3000WW &
TVL3000CW contain an automatic voltage switch, which will auto
sense the voltage when it is plugged into the power source. With this
switch there is no need to worry about the correct power voltage, this
unit can be plugged in anywhere. Also be sure to only use the included
I.E.C. power cable supplied with the unit.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX
fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of
dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX com-
pliant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave
Operation): The TVL3000WW & TVL3000CW have 1 DMX channel.
The DMX address is set electronically using the controls on the rear of
the unit. Your unit and your DMX controller require
a approved DMX-512 110 Ohm Data cable for data
input and data output. We recommend Accu-Cable
DMX cables. If you are making your own cables, be
sure to use standard 110-120 Ohm shielded cable
(This cable may be purchased at almost all professional sound and lighting stores). Your cables
should be made with a male and female XLR con-
nector on either end of the cable. Also remember
that DMX cable must be daisy chained and cannot be split.
Figure 1
Notice: Be sure to follow gures two and three when making your
own cables. Do not use the ground post on the XLR connector. Do
not connect the cable’s shield conductor to the ground lug or allow
the shield conductor to come in contact with the XLR’s outer casing.
Grounding the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
Figure 4
XLR Male Socket
1 Ground
DMX512 OUT
3-PIN XLR
2 Cold
3 Hot
1
3
2
XLR Female Socket
2 Cold
DMX +
DMX -
1 Ground
3 Hot
Figure 3
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
©Elation Professionals® - www.elationlighting.com - TVL3000WW/TVL3000CW Instruction Manual Page 6©Elation Professionals® - www.elationlighting.com - TVL3000WW/TVL3000CW Instruction Manual Page 5