Elation Therma Tour 800 User guide

Page 1
THERMA TOUR 800
US SKU#: TST801 UPC#: 810008261552
User Manual
Page 2
©2022 MAGMATIC EFFECTS all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. MAGMATIC EFFECTS logo and identifying product names and numbers herein are trademarks of MAGMATIC EFFECTS. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-MAGMATIC brands and product names are trademarks or registered trademarks of their respec­tive companies.
MAGMATIC EFFECTS and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
MAGMATIC EFFECTS | 6122 S. Eastern Ave. | Los Angeles, CA. 90040 323-582-3322 | 323-832-9142 fax | www.elationlighting.com | sales@magmaticeffects.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
Elation Professional Mexico | AC Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 +52 (728) 282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document may be available online. Please check www.elationlighting.com for the latest revision/update of this manual before beginning installation and/or programming.
Date
09/30/20 1.0 1.0 1 / 3 Channels Initial Release
Document
Version
Software
Version
DMX Channel Mode Notes
12/15/20 2.0 1.0 1 / 3 Channels
06/06/22 3.0 1.0 1 / 3 Channels Updated System Menu
Updated Dimensional Drawings & Specifica­tions
2
Page 3
CONTENTS
General Information 4
Limited Warranty (USA Only) 5
Warranty Returns (USA Only) 6
Safety Guidelines 7
Overview 9
Set Up 10
Control Panel 11
System Menu 12
Preset Mode 16
DMX Traits 17
Trouble Shooting | Cleaning & Maintenance 18
Specifications 19
Dimensional Drawings 20
3
Page 4
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use information. This product
is intended to be used by professionally trained personnel only and is not suitable for private use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Care­fully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and operate the device have arrived intact. In the event that damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS
Twist-locking power cable (x1) Haze outlet cap (x1)
CUSTOMER SUPPORT
Contact MAGMATIC customer service for any product related service and support needs. Also visit forums.elationlighting.com with questions, comments, or suggestions.
ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 323-582-3322 | Fax 323-832-9142 | sales@magmaticeffects.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET Voice: +31 45 546 85 63 | Fax: +31 45 546 85 96 | support@elationlighting.eu
REPLACEMENT PARTS: Please visit parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAM­AGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
NEVER POINT OR AIM A FOG MACHINE TOWARDS PEOPLE OR THEIR CLOTHING. THIS UNIT EMITS HOT VAPOR AND SHOULD BE USED WITH THE SAME CARE THAT YOU WOULD OBSERVE WHEN USING AN ELECTRIC KETTLE OR IRON.
4
Page 5
LIMITED WARRANTY (USA ONLY)
A. Magmatic Effects hereby warrants, to the original purchaser, Magmatic products to be free of man-
ufacturing defects in material and workmanship for a period of two years (730 days) from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including pos­sessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Magmatic Effects factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Magmatic Effects will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging mate­rial. No accessories should be shipped with the product. If any accessories are shipped with the prod­uct, Magmatic Effects shall have no liability what so ever for loss and/or or damage to any such acces­sories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the prod­uct is modified in any manner which Magmatic Effects concludes, after inspection, affects the reli­ability of the product; if the product has been repaired or serviced by anyone other than the Magmatic Effects factory unless prior written authorization was issued to purchaser by Magmatic Effects; if the product is damaged because not properly maintained as set forth in the product instructions, guide­lines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or peri­odic check-up. During the periods as specified above, Magmatic Effects will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Magmatic Effects under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Magmatic Effects. All products covered by this warranty were manufactured after January 1, 1990, and bear identifying marks to that effect.
E. Magmatic Effects reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manu­factured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied war­ranties made by Magmatic Effects in connection with this product, including warranties of merchant­ability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Magmatic Effects be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Magmatic Effects products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
5
Page 6
WARRANTY RETURNS (USA ONLY)
To obtain warranty service, a Return Material Authorization (RMA) number must first be obtained from MAGMATIC. It is the Customer’s responsibility to provide product proof of purchase and serial num­ber by acceptable evidence such as an invoice copy or an approved MAGMATIC Extended Warranty Certificate (“EWC”) and any relevant maintenance records at the time warranty service is sought. Failure to provide acceptable evidence of product proof of purchase or EWC and any relevant mainte­nance records may be cause for denial of warranty service.
Products returned for warranty service must be sent without any accessories (i.e., power, data, and safety cables, brackets, clamps, rigging hardware, frost filters, gel frames, barn doors, lenses, hoses, nozzles, rack mounting hardware, etc.), must be boxed using the original and/or suitable packag­ing materials (double-box and foam) that provides ample product protection for ground and/or air freight transit, and must be shipped freight pre-paid and insured to MAGMATIC in Los Angeles, CA or a MAGMATIC Authorized Service Center. The RMA number must be clearly written on the outside of the return box, and a brief description of the problem and the RMA number must be documented and included in the box.
Products returned for warranty service without an RMA number clearly marked on the outside of the package will be refused and returned to the shipper at the Customer’s expense. Products returned for warranty service, which are received damaged due to inadequate and/or improper packaging and/ or due to damage caused by the shipping carrier, may incur additional repair charges before warranty service begins and/or may void this warranty. If any product accessories (included and/or optional) are shipped with the product, MAGMATIC and/or the MAGMATIC Authorized Service Center shall have no liability what so ever for the loss and/or damage to any such accessories, nor the safe return thereof. If the requested warranty repairs or service (including parts replacement) are within the terms of this warranty, MAGMATIC will pay return ground transportation shipping charges to a single designated point within the United States.
6
Page 7
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Magmatic Effects is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the informa­tion printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufac­turer’s warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED.
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY
DO NOT PLUG THIS UNIT INTO A DIMMER PACK DO NOT REMOVE THE COVER UNDER ANY CONDITIONS KEEP UNIT IN AN UPRIGHT POSITION NEVER OPERATE THIS UNIT WITH THE COVER REMOVED UNPLUG FROM POWER DURING LONG PERIODS OF NON-USE ENSURE TANK IS EMPTY BEFORE STORAGE OR TRANSPORT DO NOT MOVE WHEN FILLED WITH FLUID DISCONNECT POWER BEFORE ADDING FLUID OR PERFORMING MAINTENANCE
FOR USE IN INDOOR / DRY LOCATIONS ONLY DO NOT EXPOSE DEVICE TO RAIN AND/OR MOISTURE PLACE UNIT IN A WELL VENTILATED AREA ALLOW 40” (100CM) ABOVE AND AROUND THE UNIT FOR PROPER VENTILATION.
7
Page 8
SAFETY GUIDELINES
- CAUTION: Fog machines may set off smoke alarms!
- Do not attempt installation and/or operation of this device without proper knowledge of how to do so.
- Do not point or direct fog output in an unsafe direction.
- Do not touch the front nozzle while the machine is in operation, or immediately after the device has been shut down, as the nozzle may get hot during operation.
- Do not shake device, and avoid brute force when installing and/or operating.
- Be sure to save the packing carton in the unlikely event the device may have to be returned for service.
- Do not spill water or other liquids into or on to the device. Be sure that all the fog fluid is kept inside the fluid reservoir.
- Be sure that the local power outlet matches the required voltage for the device.
- Do not remove components or disassemble the device. There are no user-serviceable parts inside.
- Never connect this device to a dimmer pack.
- Do not attempt to operate this device if it has been damaged in any way.
- Never use this device with the cover removed.
- To reduce risk of electrical shock or fire, do not expose this device to rain or moisture.
- Do not attempt to operate this device if the power cord has been frayed, crimped, and/or damaged. Replace any damaged power cords with new cords of the same power rating.
- Do not remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
- Always disconnect from main power before making any connection, performing cleaning or maintenance, or adding or draining water.
- Always drain fluid before moving the device.
- Always be sure to mount this device in an area that will allow proper ventilation.
- Always disconnect power cords during long periods of non-use.
- This unit is intended for indoor use only. Use of this product outdoors voids all warranties.
- Always mount this unit in a safe and stable matter.
- Please route your power cord out of the way of foot traffic. Power cords should be routed so they are not likely to be walked on, or pinched by items placed upon or against them.
- The device should be serviced by qualified service personnel when:
The power cords or plugs have become damaged.
Objects have fallen on and/or liquid has spilled into the device.
The device has been exposed to rain and/or moisture.
The device does not operate normally or exhibits a marked change in performance.
8
Page 9
OVERVIEW
1. Control Panel Lid
2. Haze Outlet/Filler Lid
3. Directional Blower
4. Haze Outlet w/ Cap
5. Tank Fill
6. Tank Level Gauge
7. Power In
8. Breaker
9. Power Switch
10. Cooling Vent
11. DMX In
12. DMX Out
13. Wired Remote Port
14. Touch Display Screen
9
Page 10
SET UP
1. Open the shipping carton and carefully remove the device from the shipping carton.
2. Be sure to remove ALL the packing material, paying particular attention to the area around the fog outlet vent.
3. Set the device on a flat dry surface. Open the filler/outlet lid and unscrew the tank fill cap.
4. Fill the tank only with approved ATMOSITY fluid (SKU# ARH and AAH only), and replace the reservoir cap. Never run the device on anything other than an approved, MAGMATIC branded fluid, as doing so can result in severe damage to your device.
5. Plug the device into a matching power supply and flip the power switch to the ON position.
6. After power is switched on, the device is immediately ready to emit haze. The device may be controlled manually or via DMX signal.
10
Page 11
CONTROL PANEL
This unit includes a system menu with an easy to navigate touch screen control panel where all neces­sary settings and adjustments are made. When first powering on the machine, the main menu will be displayed (see Main Menu Screen below).
Press the main menu icon you would like to access. Use the ENTER button to access sub-menus and use the UP and DOWN buttons to make adjustments. Press the ENTER button to confirm your adjust- ments. You may exit to the main menu at any time without making any adjustments by pressing the BACK/EXIT button.
After 10 seconds of non-operation, the system will return to the “Ready to Fog” status screen.
11
Page 12
SYSTEM MENU
DMX Addr 1 - 512 DMX address etting
DMX SET
DMX Mode
1-Ch
3-Ch
MagApp Name 0 - xxxxx
MagApp Passcode
MagApp ID
00000000 ­00009999
0 ~ 255.0 ~ 255.0 ~255.0 ~ 255
DMX Mode Setting
Displays name of phone when phone is connectedly to the device via MagApp
First four digits of password must be “0000”. Enter the last four digits using the keypad. When “0000” is entered for the last four digits, the device will lock.
MagApp-IP display format is a combi­nation of 4-digit 0-255 data
PERSONALITY
MagApp Set*
MapApp Port 0 - 65535
Complete
MagApp Reset
Failed, try again
MagApp > DMX & Magfly
On / Off
Network port (ten­tative)
MagApp module signal detected within 5s, reset is successful, returns to “MagApp Reset” screen after 2s
MagApp module signal not detected after 5s, reset has failed
Enable or disable MagApp data to be converted to DMX data, then sent out via DMX port and E-Fly. Note: Disable when not in use to avoid interference with other functions.
CONTINUED ON NEXT PAGE
12
Page 13
SYSTEM MENU
LCD Set Screen OFF
Never
10s
40s
1min
2min
5min
10min
20min
Set period of inac­tivity before screen turns off
PERSONALITY
(continued)
Magfly Set*
MagRF Learn*
Liquid LED On / Off
Last State Yes / No
Default Yes / No Default Interface
Fog (100%)
Magfly Channel 0 - 14
Magfly On / Off Magfly switch
Connected
Connection Failed (fails to connect within 20s)
Magfly Channel setting
MagRF module fre­quency matching
Liquid level indica­tor LED switch
Enable or disable device’s ability to stay at the last step
Return the device to default factory settings
MANUAL
TIMER
Wind (100%)
Interval 0 - 2500s
Duration 0 - 250s
CONTINUED ON NEXT PAGE
Use triangle icon to start or stop
Use triangle icon to start or stop
13
Page 14
SYSTEM MENU
Preset 1
Duration: 40 min Interval: 20 min Fog: 100% Fan: 100%
Preset 2
Duration: 30 min Interval: 15 min Fog: 100% Fan: 100%
Preset 3
Duration: 20 min Interval: 10 min Fog: 100%
PRESET
Fan: 100%
Preset 4
Duration: 10 min Interval: 5 min Fog: 100% Fan: 100%
Use triangle icon to start or stop
INFORMATION
Preset 5
Duration: 5 min Interval: 5 min Fog: 100% Fan: 100%
State Normal / Error
Slot 1 Null / Magfly / MapApp / MagRF
Slot 2 Null / Magfly / MapApp / MagRF
Last Control
MagRemote State Yes / No
LCD_auto / LCD_manual / DMX / MagApp / MagRF / MagRemote / Error
Shows whether device is operating normally
Shows what type of module is inserted in slot 1
Shows what type of module is inserted in slot 2
Current method of device control
Shows whether remote control is connected
CONTINUED ON NEXT PAGE
14
Page 15
SYSTEM MENU
Null
MagApp not con­nected to another device
INFORMATION
(continued)
MagApp Connect
Phone
Route
No
MagApp IP No / 0 ~ 255, 0 ~ 255, 0 ~ 255, 0 ~ 255
MagFly Ch. 0 - 14
DMX Addr 1 - 512
DMX Mode 1 / 3 Current DMX mode
Timer Output 100% Fixed output 100%
Timer Fan 100% Fixed blower 100%
Timer Int 0-2500s
Timer Dur 0-250s
MagApp connected to phone
MagApp connected to router
MagApp module not installed
Current IP set by the user
Current MagFly channel
Current DMX ad­dress
Current timer inter­val setting
Current timer dura­tion setting
LCD Ver Vx.x
Sftwr Ver Vx.x
Current LCD ver­sion
Current software version
* NOTE: When a module is not installed, navigating to a sub-menu related to that module’s function will result in an “Optional Module Not Installed” message displayed on the screen.
MESSAGE SMALL ICONS
Icons displayed after inserting MagFly module
Icons displayed after inserting MagApp module
Icon displayed after inserting MagRF module
Icon displayed after connecting wired remote
Left to right: weakest to strongest signal
Left to right: weakest to strongest signal
Icon appears if RF signal is present
Icon appears if remote wire is connected
15
Page 16
PRESET MODE
Preset Mode Duration Interval Fog Output Fan Intensity
1 40 min 20 min 100% 100%
2 30 min 15 min 100% 100%
3 20 min 10 min 100% 100%
4 10 min 5 min 100% 100%
5 5 min 5 min 100% 100%
PRESET SCREEN
16
Page 17
DMX TRAITS
CHANNEL
1-CH 3-CH
VALUES FUNCTION
Fog
1 1
000 - 005 Off
006 - 255 On
Duration
2
3
000 - 005 Off (0s)
006 - 255 On, 1s - 250s (steps of 1s)
Interval
000 - 005 Off (0s)
006 - 255 On, 10s - 2500s (steps of 10s)
17
Page 18
TROUBLE SHOOTING
If you experience low output, pump noise, or no output at all, disconnect the device and discontinue use immediately. Do not attempt to continue operation as this may damage the machine. Check the fluid level, the breaker, and the wall outlet to ensure it is sending power. If all the above factors do not appear to be causing the issue, and the unit still fails to operate correctly, it will require service. Please contact Magmatic Effects for assistance.
CLEANING & MAINTENANCE
When storing your device, be sure to store in a cool area. Cover the device so that dust does not build up on the device. It is highly advisable to run the machine at least once every 3-4 months when stor­ing for long periods of time. Long periods of inactivity can severely shorten the life of your device. Only run Magmatic’s Atmosity fluid (SKU# ARH or AAH) through your machine. Never run plain water, vinegar, or any other liquid solution through your device, as doing so will severely damage your device.
18
Page 19
SPECIFICATIONS
KEY FEATURES
800 Watt low power consumption Over 35 hours of run time Haze lasting up to 3 hours after machine is off Rugged mobile road case design Soundproof insulation for indoor use
DYNAMIC EFFECTS
Output: 5600 cu.ft / Min External Visual Fluid Level Detection
COMPATIBLE FLUID
Atmosity ARH (Oil based fluid)
CONSTRUCTION / PHYSICAL / PERFORMANCE
External Visual Fluid Level Detection Fluid Tank Capacity: 2.5L Fluid Consumption: 1.5ml / Min.
CONTROL
2 Card Inputs RDM (Remote DMX) Control Protocol: DMX DMX Channels: 1,3 DMX Modes: 2 On-Board Timing Control 5 Factory Presets 4-Pin Wired Remote Input Touch Screen Display Manual Hazing
CONNECTIONS
Data Connectors: 5-Pin XLR/Out, 4-Pin XLR Out Locking Power Connector
SIZE / WEIGHT
Length: 24.45 in. (621.13mm) Width: 15.34 in. (389.63mm) Height: 16.33 in. (414.75mm) Weight: 93 lbs. (42kg)
ELECTRICAL
Power Consumption: 820w Input Voltage: 120V, 230V, 240V, 50 & 60Hz Breaker Size: 15A (120V version) Breaker Size: 10A (230V version)
THERMAL
Maximum Temperature (Ambient): 104°F (40°C) Exterior Surface Temperature: 122°F (50°C)
APPROVALS / RATINGS
CE | cETLus (pending)