Elation SixPar Z19 IP Users Manual

Page 1
|
|
SIX PAR Z19 IP™
user manual
SIX PAR Z19 IP
user manual
Page 2
©2016 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
www.elationlighting.com
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this manual.
DMX
Channel Modes
7 / 9 / 10 / 14 Initial release.
Notes
Date
09/25/16
Document
Version
1 102
Software
Version
2 SIX PAR Z19 IP™ User Manual
Page 3
CONTENTS
General Information
4
Warranty
7
Safety Instructions and Guidelines
8
Overview
10
Installation
11
System Menu
14
DMX Channel Functions And Values
17
Cleaning and Maintenance
20
Technical Specifications
21
Optional Accessories
23
www.elationlighting.com
3 SIX PAR Z19 IP™ User Manual
Page 4
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable IP65 rated lighting fixtures on the market today! This fixture has been
designed to perform reliably for years when the guidelines in this booklet are
followed. Please read and understand the instructions in this manual carefully
and thoroughly before attempting to operate this unit. These instructions contain
important information regarding safety during use and maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as "IP" (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP65 rated lighting fixture is one, which has been designed and tested to protect against the ingress of dust (6) and high-pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOT suitable for marine and/or coastal environment installations. Installing this fixture in a marine and/or coastal environment may cause corrosion and/or excessive wear to the interior and/or exterior components of the fixture. Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and/or repairs.
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A
NON-CONDUCTIVE DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER INGRESS/CONDENSATION AND/OR CORROSION.
OPTIONAL CORROSION- RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture. Please consult your Elation Professional sales representative for details.
4 SIX PAR Z19 IP™ User Manual
Page 5
www.elationlighting.com
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
(1) powerCON TRUE1 Cable
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
5 SIX PAR Z19 IP™ User Manual
Page 6
www.elationlighting.com
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of
paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
6 SIX PAR Z19 IP™ User Manual
Page 7
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional® product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional® concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional® factory unless prior written authorization was issued to purchaser by Elation Professional®; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual. D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional® will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional®. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect. E. Elation Professional® reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional® in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
7 SIX PAR Z19 IP™ User Manual
Page 8
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
This fixture is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow all instructions and guidelines
in this manual. The manufacturer of this device is not responsible for injury and/or
damages resulting from the misuse of this fixture due to the disregard of the
information printed in this manual. Only qualified and/or certified personnel should
perform installation of this fixture and only the original rigging parts (omega brackets)
included with this fixture should be used for installation. Any modifications to the
fixture and/or the mounting hardware included will void the original manufactures
warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED
WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL
SHORT CIRCUIT.
8 SIX PAR Z19 IP™ User Manual
Page 9
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped and/or
damaged. If the power cord is damaged, replace it immediately with a new one
of similar power rating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and
never blocked. Allow approx. 6” (15cm) between fixture and other devices or a
wall for proper cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug
end, never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
Consistent operational breaks will ensure the fixture will function properly for
many years to come.
Use the original packaging and materials to transport the fixture in for service.
9 SIX PAR Z19 IP™ User Manual
Page 10
OVERVIEW
www.elationlighting.com
SAFETY CABLE RIGGING POINT
10 SIX PAR Z19 IP™ User Manual
Page 11
INSTALLATION
Keep fixture at least 5.0 ft (1.5m) away from any
A qualified electrician should be used for all
www.elationlighting.com
FLAMMABLE MATERIAL WARNING
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
CAUTIONS
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A
DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT
WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 5° to 113°F. (-15° to 45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
11 SIX PAR Z19 IP™ User Manual
Page 12
www.elationlighting.com
CLAMP INSTALLATION
The fixture provides an integrated mounting dual bracket / yoke. When mounting
this fixture to truss be sure to secure an appropriately rated clamp to the mounting
bracket / yoke using a M10 screw fitted through the center hole. Be sure to attach
an appropriate Safety Cable (not included) to the fixture using the safety cable
rigging point integrated into the back of the fixture.
RIGGING
Overhead rigging requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the fixture. If you lack these qualifications,
do not attempt the installation yourself. Improper installation can result in bodily
injury. Fixture is fully operational in the specific mounting positions illustrated below.
SAFETY CABLE
ALWAYS USE A SAFETY CABLE
WHENEVER INSTALLING THIS FIXTURE
IN A SUSPENDED ENVIRONMENT TO
ENSURE THE FIXTURE WILL NOT DROP
IF THE CLAMP FAILS.
12 SIX PAR Z19 IP™ User Manual
Page 13
POWER LINKING
Max number of SIX PAR Z19 IP™ units power linked together:
3 units @120V | 6 units @240V
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO SIX PAR Z19 IP™!
POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
ALWAYS CHECK MAX AMP OUT RATING PRINTED ON THE REAR CONNECTION PANEL!
www.elationlighting.com
13 SIX PAR Z19 IP™ User Manual
Page 14
www.elationlighting.com
SYSTEM MENU
The fixture includes an easy to navigate system menu control panel display where all
necessary setting adjustments are made. (See image below) During normal
operation, pressing the MODE button once will access the main menu. Once in the
main menu you can navigate through the different functions and access sub-menus
with the UP and DOWN buttons. Once you reach a field that requires adjusting, press
the ENTER button to activate that field and use the UP and DOWN buttons to adjust
the field. Pressing the ENTER button once more will confirm your setting. You may exit
the main menu at any time without making any adjustments by pressing the
MODE/ESC button.
LCD CONTROL PANEL LOCKOUT FEATURE
When the Key Lock menu (Function | LCD. Set | Key Lock) is set to ON (default setting); the LCD control panel display will turn OFF and become LOCKED after non-use. To UNLOCK, press the ENTER button followed by pressing and holding the MODE button until the LCD control panel display is UNLOCKED.
When the Key Lock menu is set to ON1 and is LOCKED, follow these steps to UNLOCK:
1. When locked, the display will show: LOCKED*****
2. Press UP, then the display will change to: LOCKED**** (one * disappears)
3. Press DOWN, then the display will change to: LOCKED*** (two * disappear)
4. Press UP, then the display will change to: LOCKED** (three * disappear)
5. Press DOWN, then the display will change to: LOCKED* (4 * disappear)
6. Press ENTER, then the display will change to LOCKED and then become unlocked.
14 SIX PAR Z19 IP™ User Manual
Page 15
ELATION© SIX PAR Z19 IP™
S Y S T E M M E N U
Features are subject to change without any prior written notice.
OPTIONS / VALUES
Set ADDR
Set ADDR
001 ~ 506
DMX Address Setting
UserMode
CH:07, CH:09, CH:10, CH:14
Set DMX Channel / User Mode
DimCurve
Set Dimmer Curve Mode
Hold / Blackout / Program
ZOOM
000 - 255
Zoom Control for Auto Run Programs
AUTO RUN
FQN:01-99
Set Number of Times Internal Program Repeats
CL:R, G, B, RG, GB, RB, RGB, BLAC
STR: 000-255
SPEED:01-99
STR: 000-255
SPEED:01-99
STR: 000-255
SPEED:01-99
STR: 000-255
Macros
00-63
Select Color Macro Value
Backligh
LCD Backlight Shut Off Time
Key Lock
ON / ON1, OFF
Control Front Panel Buttons Key Lock
DisFlash
/ OFF
Display flashes when NO DMX
DFSET
ON / OFF
Restore Factory Settings
TEMP
Fahren / Celsius
(3;>3@/BC@3'E7B163BE33<LL
Show Mode / Illumina Mode
Current
XXXX (Hours)
Fixture Run Time From Power ON
TotalTim
XXXX (Hours)
Fixture Total Run Time
Last Clea
XXXX (Hours)
Clear Fixture Last Run Time
TimerPIN
PIN= 066
Enter PIN to Access Clear Last. Menu
TempInfo
xxx°F
Temperature in Fixture Head
1U
V102
2U
V102
ErrorInf
Error Record 1 ~ Error Record 10
Display 10 Recent Error Messages
Reset. M
Reset of Zoom Motor
Calibrate
Password
Calibration of Zoom Motor
SLAVE
SLAVE
Slave Mode
ZOOM
000 - 255
Set Manual Zoom Value
Dimmer
000 - 255
Set Manual Master Dimmer Value
CW
000 - 255
Set Manual Cool White Value
WW
000 - 255
Set Manual Warm White Value
Strobe
000 - 255
Set Manual Strobe Value
ZOOM
ELATION
Six Par
www.elationlighting.com
INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:
Update Wait...
Reset...
V1.02
Z19 IP
MAIN MENU SUB MENU
No DMX
1. STATC
2. CHANG6
3CHANG30
Function
4.FADE
Zoom 000-255 Select Color Macro Zoom Value
LCD.Set
(Default Settings in
BOLD)
Standard, Stage, TV, Architectur, Theatre
02~60m 05m
ON
DESCRIPTION
Function If NO DMX Detected
Internal Program #1 Select Color and Strobe Values
Internal Program #2 Select Color and Strobe Values
Internal Program #3 Select Color and Strobe Values
Internal Program #4 Select Color and Strobe Values
TimeInfo
Info
ModelInf SixPar Z19 IP Display Model Name
Software
ZoomRset
Manual
Manual
15 SIX PAR Z19 IP™ User Manual
XXX F° / C°
ZOOM
Password= 050
Software Versions
Page 16
Function - DimCurve
Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre).
www.elationlighting.com
16 SIX PAR Z19 IP™ User Manual
Page 17
ELATION© SIX PAR Z19 IP™
Red (0-Black - 255-100%)
Green (0-Black - 255-100%)
Blue (0-Black - 255-100%)
White (0-Black - 255-100%)
Amber (0-Black - 255-100%)
UV (0-Black - 255-100%)
ZOOM
www.elationlighting.com
DMX CHANNEL FUNCTIONS AND VALUES
DMX Channel Values / Functions (14 Total Channels)
Features are subject to change without any prior written notice.
DMX CHANNEL MODE
07CH 09CH 10CH 14CH
1 1 1 1 0-255
VALUE FUNCTION
RED LED - All LEDS
2 2 2 2 0-255
3 3 3 3 0-255
4 4 4 4 0-255
5 5 5 5 0-255
6 6 6 6 0-255
7 7 7 7 0-255
8 8 8 0-255
9 9 9 0-255
0-31 NO Function
32-95 Variable Strobe Effect SLOW to FAST
10 10
96-127 LEDs ON
128-159 Pulse Effect In Sequence SLOW to FAST
160-191 LEDs ON
192-223 Random Strobe Effect SLOW to FAST
224-255 LEDs ON
GREEN LED - All LEDs
BLUE LED - All LEDs
WHITE LED - All LEDs
AMBER LED - All LEDs
UV LED - All LEDs
Zoom 0% (5 Degrees) to 100% (45 Degrees)
MASTER DIMMER
0 to 100%
MASTER DIMMER FINE (16 bit)
0 to 100%
SHUTTER / STROBE
17 SIX PAR Z19 IP™ User Manual
Page 18
ELATION© SIX PAR Z19 IP™
DMX Channel Values / Functions (14 Total Channels)
Features are subject to change without any prior written notice.
DMX CHANNEL MODE
07CH 09CH 10CH 14CH
11
www.elationlighting.com
VALUE FUNCTION
COLOR MACROS
0-3 NO Function
4-7 Color Macro 01
8-11 Color Macro 02
12-15 Color Macro 03
16-19 Color Macro 04
20-23 Color Macro 05
24-27 Color Macro 06
28-31 Color Macro 07
32-35 Color Macro 08
36-39 Color Macro 09
40-43 Color Macro 10
44-47 Color Macro 11
48-51 Color Macro 12
52-55 Color Macro 13
56-59 Color Macro 14
60-63 Color Macro 15
64-67 Color Macro 16
68-71 Color Macro 17
72-75 Color Macro 18
76-79 Color Macro 19
80-83 Color Macro 20
84-87 Color Macro 21
88-91 Color Macro 22
92-95 Color Macro 23
96-99 Color Macro 24
100-103 Color Macro 25
104-107 Color Macro 26
108-111 Color Macro 27
112-115 Color Macro 28
116-119 Color Macro 29
120-123 Color Macro 30
124-127 Color Macro 31
128-131 Color Macro 32
18 SIX PAR Z19 IP™ User Manual
Page 19
ELATION© SIX PAR Z19 IP™
DMX Channel Values / Functions (14 Total Channels)
Features are subject to change without any prior written notice.
132-135
Color Macro 33
136-139
Color Macro 34
140-143
Color Macro 35
144-147
Color Macro 36
148-151
Color Macro 37
152-155
Color Macro 38
156-159
Color Macro 39
160-163
Color Macro 40
164-167
Color Macro 41
168-171
Color Macro 42
172-175
Color Macro 43
176-179
Color Macro 44
180-183
Color Macro 45
184-187
Color Macro 46
188-191
Color Macro 47
192-195
Color Macro 48
196-199
Color Macro 49
200-203
Color Macro 50
204-207
Color Macro 51
208-211
Color Macro 52
212-215
Color Macro 53
216-219
Color Macro 54
220-223
Color Macro 55
224-227
Color Macro 56
228-231
Color Macro 57
232-235
Color Macro 58
236-239
Color Macro 59
240-243
Color Macro 60
244-247
Color Macro 61
248-251
Color Macro 62
252-255
Color Macro 63
DMX CHANNEL MODE
07CH 09CH 10CH 14CH
www.elationlighting.com
VALUE FUNCTION
COLOR MACROS - continued
11
0-20 NO Function
12
13 0-255
14
21-40 CHANGE - 30 Color Change Macro
41-60 CHANGE - 6 Color Change Macro
61-80 FADE - Color Fade Macro
81-255 NO Function
0-20 STANDARD
21-40 STAGE
41-60 TV
61-80 ARCHITECTURAL
81-100 THEATRE
101-255 Default to Unit Setting
PROGRAM MACROS
PROGRAM SPEED
Program Speed SLOW to FAST
DIMMING CURVE MODES
19 SIX PAR Z19 IP™ User Manual
Page 20
www.elationlighting.com
CLEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three months,
to make sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws may
fall out during normal operation resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
20 SIX PAR Z19 IP™ User Manual
Page 21
www.elationlighting.com
TECHNICAL SPECIFICATIONS
SOURCE
(19) 15W 6-in-1 RGBAW+UV LEDs 100,000 Hour Average Lamp Life*
*May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
COLOR
RGBAW + UV
EFFECTS
5° - 45° Beam Motorized Zoom RGBWA + UV Color Mixing Color and Chase Program Macros Electronic Strobe and Variable Dim Curves
CONTROL / CONNECTIONS
4 DMX Channel Modes (14 Total Channels) 4 Touch Button Control Panel and LCD Menu Display RDM (Remote Device Management) 180° Reversible LCD Menu Display 8 / 16 Bit Resolution Adjustable Movement IP rated 5pin DMX and powerCON TRUE1 In/Out
SIZE / WEIGHT
Length: 14.3" (363mm) Width: 12.0" (305mm) Vertical Height: 15.6" (396mm) Weight: 27.0 lbs. (12.2 kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz 282W Max Power Consumption 5F to 113°F (-15°C to 45°C) UV Wavelength: 395nm
APPROVALS / RATINGS
CE | RoHs | IP65
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
21 SIX PAR Z19 IP™ User Manual
Page 22
PHOTOMETRIC DATA
3 m
9.8 ft
4 m
13.1 ft
5 m
16.4 ft
5° Beam
lux
fc
lux
fc
lux
fc
1,859
173
1,211
113
853
79
GREEN
LEDs
BLUE LEDs
915
85
557
52
383
36
WHITE LEDs
6,221
578
3,876
360
2,750
255
AMBER
UV LEDS
121
11
80 7 44
4
FULL ON
13,240
1,230
8,371
778
5,859
544
3 m
9.8 ft
4 m
13.1 ft
5 m
16.4 ft
45° Beam
55° Field
lux
fc
lux
fc
lux
fc
132
12
78 7 49
5
GREEN
LEDs
BLUE LEDs
68 6 41 4 29
3
WHITE LEDs
431
40
246
23
152
14
AMBER
LEDs
UV LEDs
13 1 10 1 8
1
FULL ON
831
77
486
45
309
29
MIN ZOOM - 5° Beam Diameter
www.elationlighting.com
Diameter
15° Field
Diameter
RED LEDs
LEDS
Diameter
Diameter
0.26 0.9
1 3.3
6,220 578
1,351 126
MAX ZOOM - 45° Beam Diameter
2.49 8.2
3.12 10.2
0.35 1.1
1.3 4.3
3,918 364
824 77
3.31 10.9
4.16 13.6
0.43 1.4
1.6 5.2
2,755 256
687 64
4.14 13.6
5.2 17.1
RED LEDs
371 34
80 7
219 20
48 4
153 14
35 3
22 SIX PAR Z19 IP™ User Manual
Page 23
DIMENSIONAL DRAWINGS
www.elationlighting.com
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
OPTIONAL ACCESSORIES
ORDER CODE ITEM
NARROW CLAMP PRO 2” Wrap Around Clamp
NEU088 3 ft. (1m) PowerCON TRUE1 Power Link Cable
Additional Cable Lengths Available
23 SIX PAR Z19 IP™ User Manual
Page 24