Congratulations, you have just purchased one of the most innovative and
reliable lighting fixtures on the market today! This fixture has been designed to
perform reliably for years when the guidelines in this booklet are followed. Please
read and understand the instructions in this manual carefully and thoroughly
before attempting to operate this unit. These instructions contain important
information regarding safety during use and maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor
environments and has been designed with an enclosure that effectively protects
the ingress (entry) of external foreign objects such as dust and water. The
International Protection (IP) rating system is commonly expressed as "IP" (Ingress
Protection) followed by two numbers (i.e. IP65) where the numbers define the
degree of protection. The first digit (Foreign Bodies Protection) indicates the
extent of protection against particles entering the fixture and the second digit
(Water Protection) indicates the extent of protection against water entering the
fixture. An IP65 rated lighting fixture is one, which has been designed and tested
to protect against the ingress of dust (6) and high-pressure water jets from any
direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOTsuitable for marine
and/or coastal environment installations. Installing this fixture in a marine and/or
coastal environment may cause corrosion and/or excessive wear to the interior
and/or exterior components of the fixture. Damages and/or performance
issues resulting from installation in a marine and/or coastal environment will void
the manufactures warranty and will NOTbe subject to any warranty claims
and/or repairs.
Ensure ALL connections and end caps are properly sealed with a
non-conductive dielectric grease (available at most electrical suppliers) to
prevent water ingress/condensation and/or corrosion.
OPTIONAL CORROSION- RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture.
Please consult your Elation Professional sales representative for details.
4 SIXBAR 1000 IP™ User Manual
www.elationlighting.com
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
powerCON TRUE1 Power Cable 6 ft. (1.8m)
Glare Shield
(3) Glare Shield Holding Screws
(2) Lens Filters
Manual & Warranty Card
CUSTOMER SUPPORT
Elation Professional®provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
5 SIXBAR 1000 IP™ User Manual
www.elationlighting.com
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of
paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
6 SIXBAR 1000 IP™ User Manual
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to
be free of manufacturing defects in material and workmanship for a period of two years (730 days),
and Elation Professional® product rechargeable batteries to be free of manufacturing defects in
material and workmanship for a period of six months (180 days), from the original date of purchase.
This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at
the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any accessories are
shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or
damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Elation Professional® concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Elation Professional® factory unless prior written authorization was issued to purchaser by Elation
Professional®; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of Elation Professional® under
this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and PAR 200e identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole
remedy shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
7 SIXBAR 1000 IP™ User Manual
is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow the guidelines in this
evice will not accept responsibility for
damages resulting from the misuse of this fixture due to the disregard of the
. It’s essential this device be
perform all electrical
SAFETY INSTRUCTIONS
This fixture
manual. The manufacturer of this d
www.elationlighting.com
information printed in this manual.
This device falls under PROTECTION CLASS 1
grounded properly. Only qualified personnel should
connections.
UNPLUG POWER BEFORE SERVICING FIXTURE!
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
For proper operation, follow the Installation guidelines described in this manual. Only qualified
and certified personnel should perform installation of this fixture and only the original rigging parts
(brackets) included with this fixture should be used for installation. Any modifications will void the
original manufactures warranty and increase the risk of damage and/or personal injury.
Never look directly into the light source of this fixture to prevent risk of injury to your retina, which
may induce blindness. Those suffering from EPILEPSY should avoid looking directly into the light
source of this unit at all times.
The fan and air inlets must remain clean and never blocked. Allow approx. 6” (15cm) between
this fixture and other devices or a wall for proper cooling.
Always disconnect from main power source before performing any type of service and/or
cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by
tugging the wire portion of the cord.
Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If
the power cord is damaged, replace it immediately with a new one of similar power rating.
8 SIXBAR 1000 IP™ User Manual
www.elationlighting.com
GENERAL GUIDELINES
NEVER OPEN THIS FIXTURE WHILE IN USE!
Ensure ALL connections and end caps are properly sealed with a dielectric
grease (available at most electrical suppliers) to prevent water corrosion and/or
electrical short circuit.
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while
operating, to prevent any fire hazard.
The fixture must be installed in a location with adequate ventilation, at least 1.5
feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.
DO NOT attempt installation and/or operation without knowledge how to do so.
DO NOT permit operation by persons who are not qualified to operate this type
of fixture. Most damages are the result of operations by nonprofessionals.
Consistent operational breaks may ensure the fixture will function properly for
many years to come.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
Always install the fixture with an appropriate safety cable. When installing the
fixture in a suspended environment, always use mounting hardware that is no less
than M10 x 25 mm, also be sure the hardware is insert in the pre-arranged screw
holes in the bracket of the fixture.
Use the original packaging and materials to transport the fixture in for service.
DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power
and allow approximately 15 minutes for the fixture to cool down before replacing
or serving.
9 SIXBAR 1000 IP™ User Manual
FIXTURE OVERVIEW
SAFETY CABLE
www.elationlighting.com
1. Glare Shield Holding Screws (x3)
2. IP Rated Power and DMX INPUTS
3. IP Rated Power and DMX OUTPUTS
4. LCD Menu Control Display, and MENU, UP, DOWN, ENTER Buttons
5. Frost Filter Lens Release Button
10 SIXBAR 1000 IP™ User Manual
RIGGING POINT
Keep fixture at least 5.0 ft (1.5m) away from any
A qualified electrician should be used for all
FIXTURE INSTALLATION
www.elationlighting.com
FLAMMABLE MATERIAL WARNING
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 5° to 113°F. (-15° to 45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
Ensure ALL connections and end caps are properly sealed with a dielectric
grease (available at most electrical suppliers) to prevent water corrosion and/or
electrical short circuit.
POWER LINKING
Max number of units that can be power linked is 6 units @110V and 14 units @240V.
CLAMP MOUNTING
The fixture provides an integrated mounting dual bracket / yoke. Make sure to
secure an appropriately rated clamp to the mounting bracket using M10 screws
when mounting this fixture to truss.
11 SIXBAR 1000 IP™ User Manual
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the device. If you lack these qualifications,
do not attempt the installation yourself. Improper installation can result in bodily
injury. Fixture is fully operational in the specific mounting positions as illustrated
below.
www.elationlighting.com
SAFETY CABLES
ALWAYS USE A SAFETY CABLE (NOT INCLUDED) WHENEVER INSTALLING THIS FIXTURE IN A
SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS.
12 SIXBAR 1000 IP™ User Manual
Update
ELATION
1000IP
www.elationlighting.com
FIXTURE MENU
ON-BOARD SYSTEM MENU
The fixture comes with an easy to navigate system menu. The next section will detail
the functions of each command in the system menu.
LCD MENU CONTROL PANEL
The control panel (see image below) located on back of the fixture allows you to
access the main menu and make all necessary adjustments to the fixture. During
normal operation, pressing MODE button once will access the fixture’s main menu.
Once in the main menu you can navigate through the different functions and
access the sub-menus with the UP and DOWN buttons. Once you reach a field that
requires adjusting, press the ENTER button to activate that field and use the UP and
DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm
your setting. You may exit the main menu at any time without making any
adjustments by pressing the MODE button.
INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:
Specifications are subject to change without any prior written notice.
MENU
OPTIONS / VALUES (Default Settings BOLD)
DESCRIPTION
DMX MODE
CH:xx
01.STATIC
15.FLOW1
www.elationlighting.com
LCD CONTROL PANEL LOCKOUT
When AutoLock menu is set to ON, the LCD display backlight will turn OFF after 30
seconds and the Control Panel will lock and the display will show LOCKED*****.
Press and hold the MODE button for 5 seconds to unlock.
When AutoLock menu is set to ON1, the LCD display backlight will turn OFF after 30
seconds and the Control Panel will lock and the display will show LOCKED*****.
To unlock the Control Panel follow these steps:
1. When locked, the display will show: LOCKED*****
2. Press UP, then the display will change to: LOCKED**** (one * disappears)
3. Press DOWN, then the display will change to: LOCKED*** (two * disappear)
4. Press UP, then the display will change to: LOCKED** (three * disappear)
5. Press DOWN, then the display will change to: LOCKED* (4 * disappear)
6. Press ENTER, then the display will change to LOCKED and then become unlocked.
ADDR:xxx
SLAVE
M O D E
AUTO RUN
FQN:xx
-
DimCurve
Flip
NO DMX
Manual
Macros
ADDR:001 - 512
CH:06, 07, 11, 13, 36, 72, 75, 79
Set unit to Slave Mode.
FQN:01-99
01-15
Standard, Stage, TV, Architec, Theatre Set desired Dimming Curve.
ON, OFF
Hold, Blackout, Program Define how fixture reacts when NO DMX signal present.
Select the desired starting LED and chase direction from one of the following modes below
via UP/DOWN buttons and then press ENTER to confirm. (Default = STANDARD)
Actual colors may vary and subject to change without notice.
MACRO #
COLOR MACRO
DMX VALUES
GREEN + WHITE + UV
GREEN + AMBER + UV
BLUE + WHITE + AMBER
BLUE + WHITE + UV
BLUE + AMBER + UV
RED + GREEN + AMBER + UV
RED + BLUE + WHITE + UV
RED + BLUE + AMBER + UV
RED + WHITE + AMBER + UV
RED + GREEN + BLUE +AMBER + UV
RED + GREEN + WHITE + AMBER + UV
RED + BLUE + WHITE + AMBER + UV
www.elationlighting.com
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
GREEN + BLUE + AMBER
GREEN + BLUE + UV
GREEN + WHITE + AMBER
WHITE + AMBER + UV
RED + GREEN + BLUE + WHITE
RED + GREEN + BLUE + WHITE
RED + GREEN + BLUE + UV
RED + GREEN + WHITE + AMBER
RED + GREEN + WHITE + UV
RED + BLUE + WHITE + AMBER
GREEN + BLUE + WHITE + AMBER
GREEN + BLUE + WHITE + UV
GREEN + BLUE + AMBER + UV
GREEN + WHITE + AMBER + UV
BLUE + WHITE + AMBER + UV
RED + GREEN + BLUE + WHITE + AMBER
RED + GREEN + BLUE + WHITE + UV
GREEN + BLUE + WHITE + AMBER + UV
RED + GREEN + BLUE + WHITE + AMBER+ UV
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Specifications are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH 7CH 11CH 13CH 36CH 72CH 75CH 79CH
9 10 76
10 11 77
11 12 78
13 75 79
www.elationlighting.com
VALUE
PROGRAM MACROS
0-10 NO Function
11-26 Program 01 - DREAM
27-43 Program 02 - METEOR
44-60 Program 03 - FADE
61-76 Program 04 - CHANGE
77-93 Program 05 - FLOW 1
94-110 Program 06 - FLOW 2
111-126 Program 07 - FLOW 3
127-143 Program 08 - FLOW 4
144-160 Program 09 - FLOW 5
161-176 Program 10 - FLOW 6
177-193 Program 11 - FLOW 7
194-210 Program 12 - FLOW 8
211-226 Program 13 - FLOW 9
227-255 NO Function
PROGRAM SPEED
0-255 Program Speed SLOW to FAST
PROGRAM FADE
0-255 Program Fade FAST to SLOW
0-20 STANDARD
21-40 STAGE
41-60 TV
61-80 ARCHITECTURAL
81-100 THEATRE
101-255 Default to Unit Setting
DIMMING CURVE MODES
FUNCTION
28 SIXBAR 1000 IP™ User Manual
www.elationlighting.com
CLEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three
months, to make sure the circuit contacts are in good condition and prevent
overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws
may fall out during normal operation resulting in damage or injury as larger parts
could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
29 SIXBAR 1000 IP™ User Manual
www.elationlighting.com
TECHNICAL SPECIFICATIONS
SOURCE
(12) 12W 6-in-1 RGBAW+UV LEDs
100,000 Hour Average LED Life*
*May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
EFFECTS
Pixel Control
Strobe and Chase Effects
Selectable Dimming Curves
COLOR
RGBAW+UV
CONTROL / CONNECTIONS
(8) DMX Channel Modes (6 / 7 / 11 / 13 / 36 / 72 / 75 / 79)
RDM (Remote Device Management)
4 Touch Button Control Panel and LCD Menu Display
5pin IP DMX In/Out