Elation RDMS6 User Instruction

User's Instruction
RDMS6
6 Way RDM Splitter
RDMOUT1-6
12
3
4
5
6
6Way RDMBoost
RDMS6
RDM THRU
ACIN
FUSE
RDM IN
Madein P.R.C.
ACIN:
Fuse:
100-240V~50/60Hz,1A Max.
F1A250V 5x20mm
RoHS
Signal
Power
LinkOut/
Terminate
RDM DMX
CAUTION!
DONOT OPEN
Riskof Electric Shock
Nepas ouvrir. Risque
dechoc electrique
Warning:Thisapparatus
mustbe earthed
1=Ground 2=Data- 3=Data+ 4,5=NC
Product Descriptions
Technical Specifications
POWER INPUT
RDM IN/THRU,RDM OUTPUT DIMENSIONS WEIGHT
.................................................................................................................................AC 100~240V
.......................................................................................................Via 5-pin terminal
............................................................................................................................264x133.3x120mm
.......................................................................................................................................................1.45Kg
POWER CONSUMPTION ..................................................................................................................................5W
This is a 6 way RMD splitter, features one RDM IN/THRU and 6 RDM OUTPUTs. This unit takes the incoming RDM/DMX signal and splits the signal into six separate OUTPUT channels. Each OUTPUT and the IN/THRU are completely electronically isolated from each other, all six OUTPUT ports have independent output driver to boost the RDM/DMX signal.
Operation Guide
Set the RDM/DMX switch as "DMX", the RDMS6 applies to DMX signal input only and the Input/Output Signal is mono-directional communication.
Set the RDM/DMX switch as "RDM", the RDMS6 applies to DMX or RDM signal input and the Input/Output Signal is bidirectional communication.
Data Cable (DMX Cable) Requirements:
The RDMS6 is controlled via DMX-512 protocol and your DMX controller requires a standard 3-pin terminal connector for data input and data output. Connect the RDMS6 and your fixtures together using standard 3­pin DMX cables.
DMX Signal Cable. 120 ohm impedance DMX signal cable be used for signal connection.MUST
The signal indicator will blink when RDMS6 detects any signal inputs.
24-004-3067-00
Rev1.0
While need one RDMS6 in system only for operation(thus the RDM Thru needn't connect to the next RDMS6), the user may move the end-switch to terminal end for connecting to end-resistor. Regarding the other status, the end-switch should be disconnected to put through the RDM In and RDM Thru.
1
2 3 4
5 6 7
8
9
1.RDM OUT 1~6: via 3-pin XLR connector.
2.RDM Thru: via 3-pin XLR connector.
3.RDM IN: via 3-pin XLR connector.
4.RDM/DMX switch: selects signal inputs.
5.Link Out/Terminate switch: selects Link Out or Terminate.
6.Power In: Inputs a power of 100~240V AC,50/60Hz.
7.Fuse:
8.Power Indicator: It will light when contacts to the suitable power source.
9.Signal Indicator: it will blink when RB-6 TS detects any signal inputs.
Function Descriptions
Loading...